• Title/Summary/Keyword: Nuclear safety

Search Result 4,085, Processing Time 0.032 seconds

Development of ZnS(Ag)/plastic dual scintillator sheet for simultaneous alpha- and beta-ray counting (알파 및 베타선 동시측정용 ZnS(Ag)/플라스틱 이중섬광체 검출센서 개발)

  • Seo, Bum-Kyoung;Woo, Zu-Hee;Kim, Gye-Hong;Lee, Kune-Woo;Lee, Dong-Gyu;jung, Chong-Hun
    • Analytical Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.117-122
    • /
    • 2008
  • Dual scintillator for simultaneous alpha- and beta-ray counting used by detection materials of a surface contamination monitor was developed. In this study, preparation method was not a heat melting method but a solvent method, by which the counting material was manufactured by dissolving the polymer materials with solvent. It was simplified the preparation process. Plastic scintillator for beta-ray counting was prepared by solidifying the casting solution mixed with organic scintillator, polymer, and solvent. ZnS(Ag) scintillator layer was prepared by screen printing the paste solution mixed with ZnS(Ag), paste, and solvent onto the plastic layer. The good counting ability for alpha- and beta-ray using the ZnS(Ag)/plastic dual scintillator prepared and possibility for the counting material of surface contamination monitor was confirmed.

Evaluation of Occupational, Facility and Environmental Radiological Data From the Centralized Radioactive Waste Management Facility in Accra, Ghana

  • Gustav Gbeddy;Yaw Adjei-Kyereme;Eric T. Glover;Eric Akortia;Paul Essel;Abdallah M.A. Dawood;Evans Ameho;Emmanuel Aberikae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.3
    • /
    • pp.371-381
    • /
    • 2023
  • Evaluating the effectiveness of the radiation protection measures deployed at the Centralized Radioactive Waste Management Facility in Ghana is pivotal to guaranteeing the safety of personnel, public and the environment, thus the need for this study. RadiagemTM 2000 was used in measuring the dose rate of the facility whilst the personal radiation exposure of the personnel from 2011 to 2022 was measured from the thermoluminescent dosimeter badges using Harshaw 6600 Plus Automated TLD Reader. The decay store containing scrap metals from dismantled disused sealed radioactive sources (DSRS), and low-level wastes measured the highest dose rate of 1.06 ± 0.92 µSv·h-1. The range of the mean annual average personnel dose equivalent is 0.41-2.07 mSv. The annual effective doses are below the ICRP limit of 20 mSv. From the multivariate principal component analysis biplot, all the personal dose equivalent formed a cluster, and the cluster is mostly influenced by the radiological data from the outer wall surface of the facility where no DSRS are stored. The personal dose equivalents are not primarily due to the radiation exposures of staff during operations with DSRS at the facility but can be attributed to environmental radiation, thus the current radiation protection measures at the Facility can be deemed as effective.

Effect of Sofosbuvir on rats' ovaries and the possible protective role of vitamin E: biochemical and immunohistochemical study

  • Neven A. Ebrahim;Hussein Abdelaziz Abdalla;Neimat Abd Elhakam Yassin;Aya Elsayed Maghrabia;Amira Ibrahim Morsy
    • Anatomy and Cell Biology
    • /
    • v.56 no.4
    • /
    • pp.526-537
    • /
    • 2023
  • Hepatitis C virus (HCV) infection is a major health problem worldwide and its eradication is mandatory. Direct acting HCV polymerase inhibitors, such as Sofosbuvir (SOF), is an effective regimen. However, it has some side effects like mutagenesis, carcinogenesis, and the impairment of testicular function. It is important to evaluate the safety of SOF on the ovary, as there are no studies yet. Increasing the production of Reactive Oxygen Species (ROS), causes oxidative stress, which affects ovulation process, female reproduction, and fertility. Accumulation of SOF in the cells was demonstrated to promote ROS generation. Vitamin E (Vit E) is an antioxidant agent that has an essential role in the female reproductive system, its deficiency can cause infertility. We explored the effect of SOF treatment alone and co-treated with Vit E on ovarian ROS level and ovarian morphology experimentally using biochemical and immunohistochemical studies. Significant changes in oxidative stress markers; nitric oxide and malondialdehyde lipid peroxidation, antioxidant enzymes; catalase, super oxide dismutase, and reduced glutathione, proliferating markers; proliferation cell nuclear antigen and Ki-67 antigen and caspase 3 apoptotic marker were demonstrated. It was shown that where SOF induced oxidative stress, it also aggravated ovarian dysfunction. The essential role of Vit E as an antioxidant agent in protecting the ovarian tissue from the effect of oxidative stress markers and preserving its function was also displayed. This could be guidance to add Vit E supplements to SOF regimens to limit its injurious effect on ovarian function.

Methodologies for Survey and Retrofit of Small Dams Pierced by Diversion Tunnel (복통을 갖는 저수지의 결함 조사 및 보수보강 방안)

  • Jang, Bong Seok;Im, Eun Sang;Oh, Byung Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.2
    • /
    • pp.75-82
    • /
    • 2008
  • There are almost 18,000 dams including about 1,200 large dams in Korea. The large dams are well operated and maintained by KWATER(Korea Water Resource Corporation), KRC(Korea Rural Community & Agriculture Corporation) and KHNP(Korea Hydro & Nuclear Power Co., Ltd.). Several research reports concern with the safety of these large dams are presented but there is no paper concerned with small dams which has diversion tunnel through the dam body. The purpose of this study is to show the common defects of small dams according to various cases of degradation of dams and the repair and retrofit methods which applied to the damaged dams. And this study performed resistivity survey to evaluate the effect of retrofitting dam. Also, this study tries to present the solution which concerned with these common defects in maintenance and design steps.

Characterization of Particulates Containing Naturally Occurring Radioactive Materials in Phosphate Processing Facility (인광석 취급 산업체에서 발생하는 천연방사성물질 함유 입자의 특성 평가)

  • Lim, HaYan;Choi, Won Chul;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.7-13
    • /
    • 2014
  • Phosphate rock, phosphogypsum, and products in phosphate processing facility contain naturally occurring radioactive materials (NORM). Therefore, they may give rise to enhanced radiation dose to workers due to inhalation of airborne particulates. Internal dose due to particle inhalation varies depending on particle properties. The objective of the present study was to characterize particle properties at the largest phosphate processing facility in Korea. A cascade impactor was employed to sample airborne particulates at various processing areas in the plant. The collected samples were used for characterization of particle size distribution, particle concentration in the air, and shape analysis. Aerodynamic diameters of airborne particulates ranged 0.03-100 ${\mu}m$ with the highest concentration at the particle size range of 4.7-5.8 ${\mu}m$ (geometric mean = 5.22 ${\mu}m$) or 5.8-9.0 ${\mu}m$ (geometric mean = 7.22 ${\mu}m$). Particle concentrations in the air varied widely by sampling area up to more than two orders of magnitude. The large variation resulted from the variability of mechanical operations and building ventilations. The airborne particulates appeared as spheroids or rough spherical fragments across all sampling areas and sampled size intervals. Average mass densities of phosphate rocks, phosphogypsums, and fertilizers were 3.1-3.4, 2.1-2.6, and 1.7 $gcm^{-3}$, respectively. Radioactivity concentration of uranium series in phosphate rocks varied with country of origin, ranging 94-866 $Bqkg^{-1}$. Among the uranium series, uranium was mostly concentrated on products, including phosphoric acid or fertilizers whereas radium was concentrated on byproducts or phosphogypsum. No significant radioactivity of $^{226}Ra$ and $^{228}Ra$ were found in fertilizer. However, $^{40}K$ concentration in fertilizer was up to 5,000 Bq $g^{-1}$. The database established in this study can be used for the accurate risk assessment of workers due to inhalation of airborne particles containing NORM. In addition, the findings can be used as a basic data for development of safety standard and guide and for practical radiation safety management at the facility.

A study for detection of melt flow zone about polyethylene butt fusion joints (폴리에틸렌 배관 버트융착부 열용융거리 측정에 대한 연구)

  • Kil, Seonghee;Kim, Younggu;Jo, NYoungdo;Lee, Yeonjae
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2016
  • Polyethylene pipes has useful benefits which are anti-corrosive and flexible material, so it is used to gas pipes but also class 3 water pipes of nuclear power plant, process pipes of petrochemical plant and chemical plant. So the usage of polyethylene pipes is widely increased. But it has been limited for the usage of polyethylene, because it can not be directly detected to fusion joints by using non destructive evaluation. Polyethylene pipes are connected by two methods, one is butt fusion and the other is electrofusion. Butt fusion is widely used to connecting the pipes. It is proposed to method for determining the reliability of joints in this study that is detection of the melt flow zone at fusion joints. In this study, middle density polyethylene is used, outside diameter of the test specimen is 225mm and thickness is 20.5mm. Speed of ultrasonic of this test specimen is 2,200m/s. Test specimens were fabricated by varying the heating time which means from 0% to 130% applying time through heating plate to polyethylene for detecting melt flow zone. Also 4 additional test specimens were made, one was made that not scrapping attached surface of pipes but applying 100% of the proper heating time and the others were made to include of soil, gravel and vinly tape paper at fusion joints, that were also applied 100% of proper heating time. Ultrasonic testing to measure the melt flow zone of 20 test specimens was conducted by using 3.5MHz and 5.0MHz ultrasonic probes and melt flow zone measuring was conducted to three times at different point to one specimen. To differentiate the melt flow zone signal, post image processing was equally conducted to all test results and image levels, contrast, sharpen, threshold were adopted to all teat results and the test results were displayed gray scale. From the results, for the shorter heating times the reflection area of multiple echo have been increased, so the data was obtained from the position where it can be eliminated as much as possible. At 80% of proper heating time(168 sec.), the signal of melt flow zone was obtained clearly, so measuring could be conducted. From 7% of proper heating time(15 sec.) to shorter heating times. we could not obtain the signal because test specimen was not fused. From the result, we can verify that measuring of melt flow zone by using phased array ultrasonic imaging method is possible. And we can verify to complete and incomplete butt fusion by measuring the melt flow zone.

Analysis on the source characteristics of three earthquakes nearby the Gyeongju area of the South Korea in 1999 (1999년 경주 인근에서 3차례 발생한 지진들의 지진원 특성 분석)

  • Choi, Ho-Seon;Shim, Taek-Mo
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.509-515
    • /
    • 2009
  • Three earthquakes with local magnitude ($M_L$) greater than 3.0 occurred on April 24, June 2 and September 12 in 1999 nearby the Gyeongju area. Redetermined epicenters were located within the radius of 1 km. We carried out waveform inversion analysis to estimate focal mechanism of June 2 event, and P and S wave polarity and their amplitude ratio analysis to estimate focal mechanisms of April 24 and September 12 events. June 2 and September 12 events had similar fault plane solutions each other. The fault plane solution of April 24 event included those of other 2 events, but its distribution range was relatively broad. Focal mechanisms of those events had a strike slip faulting with a small normal component. P-axes of those events were ENE-WSW which were similar to previous studies on the P-axis of the Korean Peninsula. Considering distances between epicenters, similarities of seismic waves and sameness of polarities of seismic data recorded at common seismic stations, these events might occurred at the same fault. The seismic moment of June 2 event was estimated to be $3.9\;{\times}\;10^{14}\;N{\cdot}m$ and this value corresponded to the moment magnitude ($M_W$) 3.7. The moment magnitude estimated by spectral analysis was 3.8, which was similar to that estimated by waveform inversion analysis. The average stress drop was estimated to be 7.5 MPa. Moment magnitudes of April 24 and September 12 events were estimated to be 3.2 and 3.4 by comparing the spectrum of those events recorded at common single seismic station.

Antimicrobial Activity of Lactobacillus reuteri Against Major Food-Borne Pathogens (Lactobacillus reuteri의 주요 식품 위해 미생물에 대한 항균 효과)

  • Kwon, Nam-Hoon;Kim, So-Hyun;Bae, W.K.;Kim, J.Y.;Lim, J.Y.;Noh, K.M.;Kim, J.M.;Ahn, J.S.;Hur, J.;Park, Y.H.
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.4
    • /
    • pp.264-273
    • /
    • 2001
  • Antimicrobial activities of ave different probiotics (Lactobacillus reuteri, L. acidophillus, L. bulgaricus, L. casei and Bifidobacterium longum) against 8 bacterial pathogens were determined on the Mueller Hinton Agar containing supernatant of probiotics obtained from 3 different growth conditions (MRS without glycerol, MRS with 0.5 M glycerol or 0.25 M glycerol solution). Though antimicrobial activity of L. reuteri in the first two conditions was not better than the others', the activity was significantly higher than that of others in 0.25 M glycerol solution. This prominent effect might be attributable to reuterin, produced by L. reuteri using glycerol. We could detect the presence of reuterin in the supernatant of 0.25 M glycerol solution with 500 MHz Nuclear Magnetic Resonance (NMR). The result of minimum bactericidal concentration (dilution fold) has revealed that reuterin showed pan-bactericidal effects against 8 major food-borne pathogens. To examine any changes of antimicrobial activities of the probiotics, the probiotics were treated with different pH conditions, pepsin or trypsin digestion. Antimicrobial activity of reuterin was not entirely affected by any of these treatments, while the activities of the other probiotics were significantly decreased.

  • PDF

External Auditing on Absorbed Dose Using a Solid Water Phantom for Domestic Radiotherapy Facilities (고체팬텀을 이용한 국내 방사선 치료시설의 흡수선량에 대한 조사)

  • Choi, Chang-Heon;Kim, Jung-In;Park, Jong-Min;Park, Yang-Kyun;Cho, Kun-Woo;Cho, Woon-Kap;Lim, Chun-Il;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.50-56
    • /
    • 2010
  • Purpose: We report the results of an external audit on the absorbed dose of radiotherapy beams independently performed by third parties. For this effort, we developed a method to measure the absorbed dose to water in an easy and convenient setup of solid water phantom. Materials and Methods: In 2008, 12 radiotherapy centers voluntarily participated in the external auditing program and 47 beams of X-ray and electron were independently calibrated by the third party’s American Association of Physicists in Medicine (AAPM) task group (TG)-51 protocol. Even though the AAPM TG-51 protocol recommended the use of water, water as a phantom has a few disadvantages, especially in a busy clinic. Instead, we used solid water phantom due to its reproducibility and convenience in terms of setup and transport. Dose conversion factors between solid water and water were determined for photon and electron beams of various energies by using a scaling method and experimental measurements. Results: Most of the beams (74%) were within ${\pm}2%$ of the deviation from the third party's protocol. However, two of 20 X-ray beams and three of 27 electron beams were out of the tolerance (${\pm}3%$), including two beams with a >10% deviation. X-ray beams of higher than 6 MV had no conversion factors, while a 6 MV absorbed dose to a solid water phantom was 0.4% less than the dose to water. The electron dose conversion factors between the solid water phantom and water were determined: The higher the electron energy, the less is the conversion factor. The total uncertainty of the TG-51 protocol measurement using a solid water phantom was determined to be ${\pm}1.5%$. Conclusion: The developed method was successfully applied for the external auditing program, which could be evolved into a credential program of multi-institutional clinical trials. This dosimetry saved time for measuring doses as well as decreased the uncertainty of measurement possibly resulting from the reference setup in water.

Relation of Self-Efficacy and Cognition of Irradiated Food among High School Students (고등학생의 방사선조사식품에 대한 인식과 자기효능감과의 관련성)

  • Han, Eun Ok;Choi, Yoon Seok
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.106-118
    • /
    • 2013
  • In this paper, we analyzed the Cognition of irradiated food and its relation with self-efficacy. The most important variables described behaviors based on health choices compared with the choice to choose irradiated food items. According to the survey, 33.1% of respondents said that the reason why irradiated food is considered to be a health risk is because "radiation is dangerous". 27.9% of respondents answered that "eating irradiated food is like eating a radioactive substance", 21.1% said radiated food is comparable to a "genetic variation in food" while 10.1% said "food goes bad during the irradiation process". On this basis, it is reasonable to conclude that respondents have a misunderstanding of irradiated food without reference to the general theory of irradiated knowledge. In this respect, it would be helpful to provide education showing that irradiated food is not related to eating harmful or genetically modified food to help high school students create informed opinions of irradiated food. In terms of relevance with health-specific self-efficacy, experience of acquiring information about irradiated food was marked at r=0.148 (p<0.01), experience of purchasing irradiated food was marked at r=0.077 (p<0.05), experience of eating irradiated food was marked at r=0.113 (p<0.01) while knowledge of irradiated food, attitude towards irradiated food and behavior was marked at r=0.103 (p<0.01), r=0.076 (p<0.05) and r=0.105 (p<0.01) respectively. This shows that self-efficacy is high when one has experience of acquiring information about irradiated food, purchasing or eating irradiated food resulting in a high level of knowledge, attitude and behavior. Education which serves to improve the level of self-efficacy needs to be provided along with an educational program which will increase the public's understanding of irradiated food. It is expected that if this education which increases the level of self-efficacy is provided together with correct information of irradiated food, behavior to choose and eat irradiated food will also improve.