• Title/Summary/Keyword: Nuclear energy

Search Result 7,695, Processing Time 0.034 seconds

Electric Quadrupole Interaction in Copper-Iron-Chromium Oxide (구리-철-크롬 산화물에서의 전기사중극자 상호작용)

  • Shu, Seung-Wook;Choi, Eun-Jung
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.3
    • /
    • pp.89-93
    • /
    • 2008
  • Ferrimagnetic Copper-Iron-Chromium Oxide $CuFe_{0.9}Cr_{1.1}O_4$ has been investigated over a temperature range from liquid nitrogen temperature upto $N{\acute{e}}el$ temperature using the Mossbauer technique. Its $N{\acute{e}}el$ temperature is found to be 355 K. Above the $N{\acute{e}}el$ temperature the quadrupole splitting is found to be 0.50 mm/s. On the other hand, all the electric quadrupole shift values are zero below the $N{\acute{e}}el$ temperature within experimental error. These seemingly contradictory phenomena have been explained by the model that the magnetic hyperfine field is randomly oriented with respect to the principal axes of the electric-field-gradient tensor.

Greenpeace's Dirty War on Clean Energy : South Korean Version (세계의 창 - 클린 에너지에 대한 그린피스의 비열한 공격 - 한국의 사례)

  • Shellenberger, Michael
    • Nuclear industry
    • /
    • v.37 no.8
    • /
    • pp.24-33
    • /
    • 2017
  • 영화 '판도라'에 투입된 정도의 돈은 막대한 예산을 갖고 있는 국제 그린피스나 매년 전 세계 TV 광고에만 수천만 달러를 쏟아 붓는 천연가스 이익단체들의 예산에 비하면 조족지혈의 수준이다. 국제 그린피스의 연간 예산이 대략 4억 달러, EDF가 1억4천만 달러, 천연자원보호협회(NRDC)와 시에라클럽이 1억 달러가 넘고, 이들 단체가 예금이나 주식에 투자한 돈만 해도 수억 달러나 된다. 시에라클럽이나 NRDC, EDF는 블로그에 원자력을 화석연료로 대체하는 것에 반대하는 글을 올리면서 다른 한편으로는 뉴욕에 있는 Indian Point, 캘리포니아에 있는 Diablo Canyon, 그리고 오하이오에 있는 여러 원전들을 천연가스로 대체해야 한다고 주장하는 기만책을 쓰고 있다. 자연과의 조화를 위해서라도 신재생에너지를 사용해야 한다는 그들 주장의 베일 뒤에는 더 큰 어두운 그림자가 깔려 있다. 가난한 나라는 계속해서 가난하도록 해야 '과잉 인구'와 '과소비'를 막을 수 있다는 반인륜적인 멜더스(Malthusian) 이론과 그들이 주장하는 반핵의 오랜 역사는 서로 그 맥을 같이하고 있기 때문이다. 탈원전이 추진되면 전기요금도 올라가고 실업률도 증가한다는 사실, 그리고 환경 오염도 더 심해지고 그로 인해 조기 사망자 수도 증가한다는 사실을 보여주는 데 반드시 어려운 경제 모델이나 환경 모델이 필요한 것은 아니다. 원자력을 천연가스로 대체하면 그에 따른 비용 상승이 연간 최소 110억 달러나 된다. 물론 신재생에너지로 대체하게 되면 그 상승폭은 더욱 커지게 된다. 그리고 한 경제 분석 전문기관의 연구에 따르면 전기요금이 상승되면 한국의 경제는 저성장에서 벗어나지 못하게 된다. 결국 지금 우리에게 가장 필요한 것은 원자력 휴머니즘, 즉 원자력 에너지가 갖고 있는 훌륭한 도덕적인 목적을 다시 한 번 상기하면서, 우리 인류가 가지고 있는 가장 중요한 환경 기술을 반인륜적인 집단으로부터 구해내기 위한 풀뿌리 시민사회의 가열찬 노력이라고 할 수 있다. 우리와 같은 원자력 휴머니스트들에게는 그린피스나 기타 여러 반인륜적 집단들이 갖고 있는 풍부한 자원이 없다. 그러나 우리에게는 그런 종류의 자원이 필요한 것이 아니다. 우리에게는 그것보다 훨씬 더 중요한 진실이라는 자원이 있다는 사실을 결코 잊어서는 안될 것이다.

  • PDF

Radioprotective Effect of Extracts from Plants Indigenous to Korea

  • Kang Kyoung-Ah;Zhang Rui;Chae Sung-Wook;Piao Mei Jing;Shin Tae-Kyun;Lee Nam-Ho;Park Jae-Woo;Hyun Jin-Won
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.115-122
    • /
    • 2006
  • We have screened the cytoprotective effect on $\gamma$-ray radiation induced oxidative stress from eighteen Korean plant extracts. Querus salicina, Clerodendron trichotomum, Lamium amplexicaule, Lozoste lancifolia and Malus baccata were found to scavenge 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical and intracellular reactive oxygen species (ROS). As a result, extracts of these plants reduced cell death of Chinese hamster lung fibroblast (V79-4) cells induced by $H_2O_2$ treatment. In addition, these extracts protected cell death of V79-4 cells damaged by $\gamma$-ray radiation. In addition, these extracts scavenged ROS generated by radiation. Taken together, the results suggest that Quercus salicina, Clerodendron trichotomum, Lamium amplexicaule, Lozoste lancifolia and Malus baccata protect V79-4 cells against oxidative damage by radiation through scavenging ROS.

Formation of Ultra fine Particle by the Polonium-218 Ions under Different Humidity Conditions (다른 습도조건하에서 Po-218 이온들의 극소입자형성에 관한 연구)

  • Yoon, Suk-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.1
    • /
    • pp.1-10
    • /
    • 1992
  • A number of investigators have reported the formation of the radiolytic ultrafine particles produced by the interaction of ionizing radiation with water vapor. Previous studies have suggested that a very high localized concentration of the OH radical produced by the radiolysis of water can react with trace gas like organic vapors and produce lower vapor pressure compounds that can then nucleate. In order to determine water vapor dependence of the active, positively charged, first radon daughter(Po-218), an experiment was conducted using a well-controlled radon chamber. The activity size distribution of the radon daughter in the range of 0.5-100nm was measured using the parallel graded wire screens system. Measurements were taken for different relative humidity. The resultant activity size distributions were analyzed. The addition of water vapor to the radon carrier gases resulted in the formation of ultrafine particles by OH radicals formed by radon radiolysis. It may be due to the neutralization of charged Po-218 ion with water vapor through the radio lysis.

  • PDF

Development of a Femur Neck Bone Mineral Density Measuring Device for Accurate Examination

  • Han, Man-Seok;Seo, Sun-youl;Kim, Yong-Kyun;Jeon, Min-Cheol;Lee, Hyun-kuk;Yoo, Se-Jong
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.298-302
    • /
    • 2016
  • In bone density examinations, a change in the measured BMD occurs owing to the differences between the measured areas. To address this problem, we aimed to develop a new auxiliary device that could be rotated by $15^{\circ}$ by fixing the ankle to the distal femur neck. Dual energy X-ray absorptiometry (DXA) of BMD examinations were performed once a year, but 10 patients were examined over three sessions to analyze the area for measuring the femur neck BMD. The goal of this test was to determine the device's reliability, and the results were expressed in terms of the standard deviation of measurements. After performing bone density measurements using the new auxiliary device on 10 normal patients, with three measurements for each patient, the obtained standard deviation was 0.03. The standard deviation of the measured BMD was 0.19 when using the currently existing auxiliary device, while the standard deviation of the measured BMD was 0.03 when using the new auxiliary device. By using the new auxiliary device, the standard deviation could be reduced by ~80%. Accurate rotation of the femur neck was possible in all examinations, and the standard deviation of BMD measurements could be reduced by up to 80% compared with the measurements performed using the currently existing auxiliary device. We hope that this advantageous new design can be used as a standard auxiliary device for measuring the femur neck BMD.

Reliability Assessment for Corroded Pipelines by Separable Monte Carlo Method (Separable Monte Carlo 방법을 적용한 부식배관 신뢰도평가)

  • Lee, Jin-Han;Jo, Young-Do;Kim, Lae Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.81-86
    • /
    • 2015
  • A deterministic stress-based methodology has traditionally been applied in pipeline design. Meanwhile, reliability based design and assessment (RBDA) methodology has been extensively applied in offshore or nuclear structures. Lately, the release of ISO standard on reliability based limit state methods for pipelines ISO16708 indicates that the RBDA methodology is one of the newest directions of natural gas pipeline design method. This paper presents a case study of the RBDA procedure for predicting the time-dependent failure probability of pipelines with corrosion defects, where separable Monte Carlo (SMC) method is applied in the reliability estimation for corroded pipeline instead of traditional, crude Monte Carlo(CMC) Method. The result shows the SMC method take advantage of improving accuracy in reliability calculation.

A Study on Characteristics of A Diode Radiation Sensor for Portal Image of Therapy Radiation (치료방사선 Portal Image를 위한 다이오드 방사선 센서의 특성에 관한 연구)

  • Lee, Dong-Hun;Kwon, Jang-Woo;Hong, Seung-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.11-20
    • /
    • 1996
  • In this paper, the characteristics of therapy radiation diode sensors have been studied by using therapy radiation from the MM22 microtron accelerator. The linearity, reproducibility and error ratio were measured for feasibility as a radiation detector. Energy dependence, sensitivity change after a amount of irradiation and output value according to a number of diodes were also measured for same purpose. We have formed pulse shaping of diode signal with nuclear instruments for portal image reconstruction. The percent depth dose ratio according to field size and depth was compared with that of the detector of a ion chamber. Using thirteen silicon diodes, we can directly read diode outputs on a computer monitor after A/D conversion with 16 channels analog to digital conversion board with 12 bit resolution. The possibility for portal image with diodes has been suggested from output comparison between output value with a human phantom and that without a human phantom.

  • PDF

Determination of trace actinide (Am, Pu, Th, U) using alpha spectrometry and neutron activation analysis (알파분광법과 중성자방사화분석법에 의한 극미량의 악티늄계원소 (Am, Pu, Th, U)분석연구)

  • Yoon, Yoon Yeol;Lee, Kil Yong;Cho, Soo Young;Kim, Yongjai;Lee, Myong Ho
    • Analytical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.302-307
    • /
    • 2004
  • Determination of actinides in the environmental sample requires separation of each element. This procedure is tedious and time consuming. And also, the detection limits of some nuclides using alpha spectrometry are rather higher. To overcome the lower detection limit and complicated separation procedure, a simple analytical technique for the determination of actinide isotopes in the environmental samples was developed and applied to IAEA and NIST reference sediment samples. For the separation of actinides from matrix, anion exchange resin and TRU-spec extraction chromatography resin were used and chemical yields were obtained using natural uranium, thorium, $^{242}Pu$ and $^{243}Am$ tracers. For overcoming the higher detection limits of U and Th in alpha spectrometry, neutron activation analysis was applied. Using combined method, the detection limit was increased about 10 times. The activity values of each isotope were consistent with the reference values reported by IAEA and NIST.

Fabrication of Miniature Radiation Sensor Using Plastic Optical Fiber for Medical Usage (플라스틱 광섬유를 이용한 초소형 의료용 방사선 센서 제작)

  • Hwang, Young-Muk;Cho, Dong-Hyun;Cho, Hyo-Sung;Kim, Sin;Lee, Bong-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.9-12
    • /
    • 2005
  • In this study, film type radiation sensor tips are fabricated for remote sensing of X or g-ray with inorganic scintillators and plastic optical fiber. The visible range of light from the inorganic scintillator that is generated by X and g-ray is guided by the plastic optical fiber and is measured by optical detector and power-meter. It is expected that the fiber-optic radiation sensor which is possible to be developed based on this study is used for remote, fast and exact sensing of X or g-ray because of its characteristics such as very small size, light weight and no interference to electromagnetic fields.

  • PDF

Study on Measurements in Thyroid Uptake Rate Test (갑상선섭취율검사시(甲狀腺攝取率檢査時) 측정조건(測定條件)에 관(關)한 조사연구(調査硏究))

  • Kyong, Kwang-Hyon;Kim, Hwa-Gon
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.55-62
    • /
    • 1981
  • This study was conducted, during the period of 20-30th, July in 1981, to survey measurement methods in thyroid uptake rate test in Seoul city. The results were summarized as follows: 1. For the great part of nuclear medcine department, a mount of radioiodine($^{131}I$) administrated to the patients was $50-100{\mu}Ci$ in thyroid uptake rate test. 2. Distribution of scintillation, counter with crystal size of $1\frac{1}{2}inch$ was 43%, 3inch(22%), 2.5inch(14%) and $2\frac{1}{2}inch$ was 7% in RAI uptake rate test. 3. When RAI uptake rate test was performed, distribution of collimator in use was flat field type collimator(78%) in general and cylindrical type collimator was 22%. 4. High voltage applied to the P-M tube was $900{\sim}1000V$(50%) and most units provided $3{\sim}15%$ of the window range for the $^{131}I$ peak $\gamma-ray$ energy. 5. Distribution on the use of neck phantom for measurements standard solution was 57% and distribution of b filter in use for room background counts and extrathyroidal tissue was 43% and 50%. 6. The distance between the counter and the source was 25cm(58%) in measuring radioactivity of standard solution, thyroid tissue and background radioactivity count. 7. The early uptake measurements(2, 4, 6 hours) are done after administration of the radioiodine dose and also 24-hour and 48-hour uptake measurements are done in routine test.

  • PDF