• Title/Summary/Keyword: Nuclear Vessel

Search Result 757, Processing Time 0.023 seconds

Dehydriding Performance in a Depleted Uranium Bed (감손 우라늄 베드 수소 탈장 성능)

  • KOO, DAESEO;KIM, YEANJIN;YUN, SEI-HUN;CHUNG, HONGSUK
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.1
    • /
    • pp.22-28
    • /
    • 2016
  • It is necessary to store and supply hydrogen isotopes for Tokamak operation. A storage and delivery system (SDS) is used for storing hydrogen isotopes as a metal hydride form. We designed and fabricated a depleted uranium (DU) bed to store hydrogen isotopes. The rapid storage of hydrogen isotopes is very important not only for safety reasons but also for the economic design and operation of the SDS. The delivery rate at the desorption temperatures without the operation of a dry pump was analyzed in comparison with that with the operation of the dry pump. The effect of the initial desorption temperatures on the dehydriding of the DU without the operation of the dry pump was measured. The effect of the initial desorption temperatures on the dehydriding of DU with the operation of the dry pump was also measured and analyzed. The primary pressure on the desorption temperatures without the operation of the dry pump was analyzed in comparison with that with the operation of the dry pump. The temperature gradient of the coil heater and the primary vessel was also analyzed. Our results will be used to develop pilot scale hydrogen isotope processes. It was confirmed that dehydriding of a medium-scale DU bed has enabled without the operation of the dry pump.

A Measurement Method of Internal Defects of Pressure Vessles by Using Real-Time Holographic Interferometry (실시간 홀로그래픽 간섭법을 이용한 압력용기의 내부결함 측정법)

  • Moon, Sang-Joon;Kang, Young-June;Baik, Sung-Hoon;Kim, Cheol-Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1233-1240
    • /
    • 1996
  • Conventional measurement methods using ultrasonic wave or x-ray, eddy current for non-destructive testing(NDT) in nuclear power plants and other industrial plants have been utilized as the method of contact with objects to be inspected. For this reason these methods require relatively much time and inspection area is limited by the location of probe or film. But holograpic interferometry which is a non-contact optical measurement method using a coherent light source has an advantage that quantative measurement can be performed at a time. In this paper a new method using realtime holographic interfreometry and image processing for detecting internal flaws of pressure vessels is presented.

Source Localization Technique for Metallic Impact Source by Using Phase Delay between Different Type Sensors (다종 센서간 위상 차이를 이용한 충격 위치추정 기법)

  • Choi, Kyoung-Sik;Choi, Young-Chul;Park, Jin-Ho;Kim, Whan-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.11
    • /
    • pp.1143-1149
    • /
    • 2008
  • In a nuclear power plant, loose part monitoring and its diagnostic technique is one of the major issues for ensuring the structural integrity of the reactor system. Typically, accelerometers are mounted on the surface of a reactor vessel to localize impact location cavsed by the impact of metallic substances on the reactor system. However, in some cases, the number of the accelerometers is not enough to estimate the impact location precisely. In such a case, one of alternative plan is to utilize another type sensors that can measure the vibration of the reactor structure even though the measuring frequency ranges are different from each others. The AE sensors installed on the reactor structure can be utilized as additional sensors for loose part monitoring. In this paper, we proposed a new method to estimate impact location by using both accelerometer signal and AE signal, simultaneously. The feasibility of the proposed method is verified by an experiment. The experimental results demonstrate that we can enhance the reliability and precision of the loose part monitoring.

A novel low-profile flow sensor for monitoring of hemodynamics in cerebral aneurysm

  • Chen, Yanfei;Jankowitz, Brian T.;Cho, Sung Kwon;Yeo, Woon-Hong;Chun, Youngjae
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.2
    • /
    • pp.71-84
    • /
    • 2015
  • A low-profile flow sensor has been designed, fabricated, and characterized to demonstrate the feasibility for monitoring hemodynamics in cerebral aneurysm. The prototype device is composed of three micro-membranes ($500-{\mu}m$-thick polyurethane film with $6-{\mu}m$-thick layers of nitinol above and below). A novel super-hydrophilic surface treatment offers excellent hemocompatibility for the thin nitinol electrode. A computational study of the deformable mechanics optimizes the design of the flow sensor and the analysis of computational fluid dynamics estimates the flow and pressure profiles within the simulated aneurysm sac. Experimental studies demonstrate the feasibility of the device to monitor intra-aneurysmal hemodynamics in a blood vessel. The mechanical compression test shows the linear relationship between the applied force and the measured capacitance change. Analytical calculation of the resonant frequency shift due to the compression force agrees well with the experimental results. The results have the potential to address important unmet needs in wireless monitoring of intra-aneurysm hemodynamic quiescence.

Variables of Electrolytic Nickel Plating for RPV Cladding Repair (압력용기 클래드 보수용 전해니켈도금 인자 관계 연구)

  • Kim, Min-Su;Hwang, Seong-Sik;Kim, Dong-Jin;Lee, Dong-Bok
    • Corrosion Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.148-153
    • /
    • 2019
  • Pure nickel with a thickness of 1 mm was plated on type 304 stainless steels and low alloy steels (JIS G3131 SPHC) by electrolytic plating method in a circulating plating bath. Plating performance, mechanical properties, and surface characteristics were evaluated in terms of pretreatment process, anode material, pH, current density, and flow rate of the plating solution. Addition of hydrochloric acid during pre-treatment process improved the adhesion performance of plating. To improve plating efficiency, it is desirable to use S-nickel rather than electrolytic nickel. The use of S-nickel was also confirmed to be desirable for maintaining the pH and concentration of the plated solution. The defect of the plating using S-nickel anode produced pit on the surface. However, it is believed that proper control can be obtained by increasing the flow rate. Internal stress and hardness values of electrolytic nickel plating according to current density need to be carried out with further studies.

Measuring T1 contrast in ex-vivo prostate tissue at the Earth's magnetic field

  • Oh, Sangwon;Han, Jae Ho;Kwon, Ji Eun;Shim, Jeong Hyun;Lee, Seong-Joo;Hwang, Seong-Min;Hilschenz, Ingo;Kim, Kiwoong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.23 no.1
    • /
    • pp.12-19
    • /
    • 2019
  • A former study has shown that the spin-lattice relaxation time ($T_1$) in cancerous prostate tissue had enhanced contrast at an ultra-low magnetic field, $132{\mu}T$. To study the field dependence and the origin of the contrast we measured $T_1$ in pairs of ex-vivo prostate tissues at the Earth's magnetic field. A portable and coil-based nuclear magnetic resonance (NMR) system was adopted for $T_1$ measurements at $40{\mu}T$. The $T_1$ contrast, ${\delta}=1-T_1$ (more cancer)/$T_1$(less cancer), was calculated from each pair. Additionally, we performed pathological examinations such as Gleason's score, cell proliferation index, and micro-vessel density (MVD), to quantify correlations between the pathological parameters and $T_1$ of the cancerous prostate tissues.

Review, Assessment, and Learning Lesson on How to Design a Spectroelectrochemical Experiment for the Molten Salt System

  • Killinger, Dimitris;Phongikaroon, Supathorn
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.2
    • /
    • pp.209-229
    • /
    • 2022
  • This work provided a review of three techniques-(1) spectrochemical, (2) electrochemical, and (3) spectroelectrochemical-for molten salt medias. A spectroelectrochemical system was designed by utilizing this information. Here, we designed a spectroelectrochemical cell (SEC) and calibrated temperature controllers, and performed initial tests to explore the system's capability limit. There were several issues and a redesign of the cell was accomplished. The modification of the design allowed us to assemble, align the system with the light sources, and successfully transferred the setup inside a controlled environment. A preliminary run was executed to obtain transmission and absorption background of NaCl-CaCl2 salt at 600℃. It shows that the quartz cuvette has high transmittance effects across all wavelengths and there were lower transmittance effects at the lower wavelength in the molten salt media. Despite a successful initial run, the quartz vessel was mated to the inner cavity of the SEC body. Moreover, there was shearing in the patch cord which resulted in damage to the fiber optic cable, deterioration of the SEC, corrosion in the connection of the cell body, and fiber optic damage. The next generation of the SEC should attach a high temperature fiber optic patch cords without introducing internal mechanical stress to the patch cord body. In addition, MACOR should be used as the cell body materials to prevent corrosion of the surface and avoid the mating issue and a use of an adapter from a manufacturer that combines the free beam to a fiber optic cable should be incorporated in the future design.

Evaluation of MCCI Behaviors in the Calandria Vault of CANDU-6 Plants Using CORQUENCH Code (CORQUENCH 코드를 활용한 중수로 calandria vault에서의 MCCI 거동 분석)

  • Seon Oh YU
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.2
    • /
    • pp.90-100
    • /
    • 2021
  • Molten corium-concrete interaction (MCCI) is one of the most important phenomena that can lead to the potential hazard of late containment failure due to basemat penetration during a severe accident. In this study, MCCI analytical models of the CORQUENCH code were prepared through verification calculations of several experiments, which had been performed using concrete types similar to those of the calandria vault floor in CANDU-6 plants. The behaviors of thermal-hydraulic variables related to MCCI phenomena were analyzed under the conditions of dry floor and water flooding during the severe accident stemming from a hypothetic station blackout. Uncertainty analyses on the ablation depth were also carried out. It was estimated that the concrete ablation was not interrupted due to the continuous MCCI process under the dry condition but was terminated within 24 hours under the water flooding condition. It was confirmed that the water flooding as a mitigating action was effective to achieve the quenching and thermal stabilization of the melt discharged from the calandria vessel, showing that the present models are capable of reasonably simulating MCCI phenomena in CANDU-6 plants. This study is expected to provide the technical bases to the accident management strategy during the late-phase severe accidents.

Consideration of residual mode response in time history analysis using residual vector (Residual Vector를 이용한 시간이력해석의 잔여모드 응답 고려 방법)

  • Chang Ho Byun;Han Geol Lee;Jung Yong Kim
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.17 no.2
    • /
    • pp.137-144
    • /
    • 2021
  • The mode superposition time history analysis method is commonly used in a seismic analysis. The maximum response in the time history analysis can be derived by combining the responses of individual modes. The residual mode response is the response of the modes which are not considered in the time history analysis. In this paper, the residual vector method to consider the residual mode response in the time history analysis is introduced and evaluated. Seismic analyses for a sample structure model and a reactor vessel model are performed to evaluate the residual vector method. The analysis results show that residual mode response is well calculated when the residual vector method is used. It is confirmed that the residual vector method is useful and acceptable to consider the residual mode response in a seismic analysis of the nuclear power plant equipment.

Influence of dynamic strain aging on material strength behavior of virgin and service-exposed Gr.91 Steel (신재 및 가동이력 Gr.91강의 재료강도 거동에 미치는 동적변형시효의 영향)

  • Ki-Ean Nam;Hyeong-Yeon Lee;Jae-Hyuk Eoh;Hyungmo Kim;Hyun-Uk Hong
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.20 no.1
    • /
    • pp.66-74
    • /
    • 2024
  • This study investigates the effects of temperatures and strain rates on the strength and ductility of Gr.91 (ASME Grade 91) steel which is widely being used as a heat-resistant material in Generation IV nuclear and super critical thermal power plants. The tensile behavior of modified 9Cr-1Mo (Gr.91) steel was studied for the three strain rates of 6.67×10-5/s, 6.67×10-4/s and 6.67×10-3/s over the temperature range from room temperature (RT) to 650℃. Experimental results showed that at specific combinations of temperatures (300~400℃) and strain rates, serrations appeared in the stress-strain curves. Concurrently, abnormal behaviors such as a plateau in yield strength and tensile strength, a minimum in ductility and negative strain rate sensitivity were observed. These phenomena were analyzed as significant characteristics of dynamic strain aging (DSA). Since this abnormal behavior in Gr.91 steel affects the material strength, it is judged that a correlation analysis between DSA and material strength should be crucial in the design and integrity evaluation of Gr. 91 steel pressure vessel and piping subjected to high-temperature loading.