• 제목/요약/키워드: Nonlinear parameter B/A

검색결과 101건 처리시간 0.029초

In Situ Monitoring of the MBE Growth of AlSb by Spectroscopic Ellipsometry

  • 김준영;윤재진;이은혜;배민환;송진동;김영동
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.342-343
    • /
    • 2013
  • AlSb is a promising material for optical devices, particularly for high-frequency and nonlinear-optical applications. And AlSb offers significant potential for devices such as quantum-well lasers, laser diodes, and heterojunction bipolar transistors. In this work we study molecular beam epitaxy (MBE) growth of an unstrained AISb film on a GaAs substrate and identify the real-time monitoring capabilities of in situ spectroscopic ellipsometry (SE). The samples were fabricated on semi-insulating (0 0 1) GaAs substrates using MBE system. A rotating sample stage ensured uniform film growth. The substrate was first heated to $620^{\circ}C$ under As2 to remove surface oxides. A GaAs buffer layer approximately 200 nm- thick was then grown at $580^{\circ}C$. During the temperature changing process from $580^{\circ}C$ to $530^{\circ}C$, As2 flux is maintained with the shutter for Ga being closed and the reflection high-energy electron diffraction (RHEED) pattern remaining at ($2{\times}4$). Upon reaching the preset temperature of $530^{\circ}C$, As shutter was promptly closed with Sb shutter open, resulting in the change of RHEED pattern from ($2{\times}4$) to ($1{\times}3$). This was followed by the growth of AlSb while using a rotating-compensator SE with a charge-coupled-device (CCD) detector to obtain real-time SE spectra from 0.74 to 6.48 eV. Fig. 1 shows the real time measured SE spectra of AlSb on GaAs in growth process. In the Fig. 1 (a), a change of ellipsometric parameter ${\Delta}$ is observed. The ${\Delta}$ is the parameter which contains thickness information of the sample, and it changes in a periodic from 0 to 180o with growth. The significant change of ${\Delta}$ at~0.4 min means that the growth of AlSb on GaAs has been started. Fig. 1b shows the changes of dielectric function with time over the range 0.74~6.48 eV. These changes mean phase transition from pseudodielectric function of GaAs to AlSb at~0.44 min. Fig. 2 shows the observed RHEED patterns in the growth process. The observed RHEED pattern of GaAs is ($2{\times}4$), and the pattern changes into ($1{\times}3$) with starting the growth of AlSb. This means that the RHEED pattern is in agreement with the result of SE measurements. These data show the importance and sensitivity of SE for real-time monitoring for materials growth by MBE. We performed the real-time monitoring of AlSb growth by using SE measurements, and it is good agreement with the results of RHEED pattern. This fact proves the importance and the sensitivity of SE technique for the real-time monitoring of film growth by using ellipsometry. We believe that these results will be useful in a number of contexts including more accurate optical properties for high speed device engineering.

  • PDF

REGULARITY AND MULTIPLICITY OF SOLUTIONS FOR A NONLOCAL PROBLEM WITH CRITICAL SOBOLEV-HARDY NONLINEARITIES

  • Alotaibi, Sarah Rsheed Mohamed;Saoudi, Kamel
    • 대한수학회지
    • /
    • 제57권3호
    • /
    • pp.747-775
    • /
    • 2020
  • In this work we investigate the nonlocal elliptic equation with critical Hardy-Sobolev exponents as follows, $$(P)\;\{(-{\Delta}_p)^su={\lambda}{\mid}u{\mid}^{q-2}u+{\frac{{\mid}u{\mid}^{p{^*_s}(t)-2}u}{{\mid}x{\mid}^t}}{\hspace{10}}in\;{\Omega},\\u=0{\hspace{217}}in\;{\mathbb{R}}^N{\backslash}{\Omega},$$ where Ω ⊂ ℝN is an open bounded domain with Lipschitz boundary, 0 < s < 1, λ > 0 is a parameter, 0 < t < sp < N, 1 < q < p < ps where $p^*_s={\frac{N_p}{N-sp}}$, $p^*_s(t)={\frac{p(N-t)}{N-sp}}$, are the fractional critical Sobolev and Hardy-Sobolev exponents respectively. The fractional p-laplacian (-∆p)su with s ∈ (0, 1) is the nonlinear nonlocal operator defined on smooth functions by $\displaystyle(-{\Delta}_p)^su(x)=2{\lim_{{\epsilon}{\searrow}0}}\int{_{{\mathbb{R}}^N{\backslash}{B_{\epsilon}}}}\;\frac{{\mid}u(x)-u(y){\mid}^{p-2}(u(x)-u(y))}{{\mid}x-y{\mid}^{N+ps}}dy$, x ∈ ℝN. The main goal of this work is to show how the usual variational methods and some analysis techniques can be extended to deal with nonlocal problems involving Sobolev and Hardy nonlinearities. We also prove that for some α ∈ (0, 1), the weak solution to the problem (P) is in C1,α(${\bar{\Omega}}$).

Mn을 첨가한 ZnO-TeO2 세라믹스의 소결과 전기적 특성 (Sintering and Electrical Properties of Mn-doped ZnO-TeO2 Ceramics)

  • 홍연우;신효순;여동훈;김종희;김진호
    • 한국전기전자재료학회논문지
    • /
    • 제22권1호
    • /
    • pp.22-28
    • /
    • 2009
  • We investigated the sintering and electric properties of ZnO-1.0 at% $TeO_2$ (ZT1) and 1.0 at% Mn-doped ZT1(ZT1M1) system. $TeO_2$ itself melts at $732^{\circ}C$ in air but forms the $ZnTeO_3$ or $Zn_2Te_3O_8$ phase with ZnO as increasing temperature and therefore retards the densification of ZnO to $1000^{\circ}C$. In ZT1M1 system, also, the densification of ZnO was retarded up to $1000^{\circ}C$ and then reached > 90% of theoretical density above $1100^{\circ}C$. It was found that a good varistor characteristics(nonlinear coefficient $a{\sim}60$) were developed in ZT1M1 system sintered at $1100^{\circ}C$ due to Mn which known as improving the nonlinearity of ZnO varistors. The results of C-V characteristics such as barrier height (${\Phi}_b$), donor density ($N_D$), depletion layer (W), and interface state density ($N_t$) in ZT1M1 ceramics were $1.8{\times}10^{17}cm^{-3}$, 1.6 V, 93 nm, and $1.7{\times}10^{12}cm^{-2}$, respectively. Also we measured the resistance and capacitance of grain boundaries with temperature using impedance and electric modulus spectroscopy. It will be discussed about the stability and homogeneity of grain boundaries using distribution parameter ($\alpha$) simulated with the Z(T)"-logf plots.

윈도우를 이용한 멀티톤 데이터 통신용 코사인 변조 필터뱅크 디자인 (Window Approach for Cosine-Modulated Filter Bank Design for Multitone Data Communication)

  • 김정학;신승철;정진균;송상섭
    • 한국통신학회논문지
    • /
    • 제24권8B호
    • /
    • pp.1586-1592
    • /
    • 1999
  • 고속모뎀(DSL)에 사용되는 DWMT(Discrete Wavelet Multitone)는 변복조에 CMFB (Cosine Modulated Filter Bank)를 사용한다. CMFB는 DFT 필터 뱅크에 비해 서브채널들 사이의 간섭이 감소되고, 하나의 원형 필터를 이용해 다른 모든 서브채널 필터들을 만들어낼 수 있으며 고속 알고리듬을 이용한 효율적인 구현이 가능하다. CMFB의 원형 필터를 디자인하는 전형적인 방법들은 보통 비선형 최적화 과정을 포함하며 차수가 작은 필터를 디자인하는데도 상당히 긴 디자인 시간이 요구된다. 본 논문에서는 optimal 윈도우를 이용한 CMFB의 원형 필터 디자인 방법을 제시한다. 이 필터의 디자인 과정은 하나의 파라미터만을 최적화하기 때문에 다른 방법들에 비해 디자인 시간이 짧다. 또한 제안된 디자인 방법으로 디자인된 필터는 멀티캐리어 통신 시 중요한 파라미터인 원형 필터의 저지대역 특성이 Kaiser 윈도우에 의한 필터의 특성에 비해 더 좋음을 보였다.

  • PDF

Comparative Study on Growth Patterns of 25 Commercial Strains of Korean Native Chicken

  • Manjula, Prabuddha;Park, Hee-Bok;Yoo, Jaehong;Wickramasuriya, Samiru;Seo, Dong-Won;Choi, Nu-Ri;Kim, Chong Dae;Kang, Bo-Seok;Oh, Ki-Seok;Sohn, Sea-Hwan;Heo, Jung-Min;Lee, Jun-Heon
    • 한국가금학회지
    • /
    • 제43권1호
    • /
    • pp.1-14
    • /
    • 2016
  • Prediction of growth patterns of commercial chicken strains is important. It can provide visual assessment of growth as function of time and prediction body weight (BW) at a specific age. The aim of current study is to compare the three nonlinear functions (i.e., Logistic, Gompertz, and von Betalanffy) for modeling the growth of twenty five commercial Korean native chicken (KNC) strains reared under a battery cage system until 32 weeks of age and to evaluate the three models with regard to their ability to describe the relationship between BW and age. A clear difference in growth pattern among 25 strains were observed and classified in to the groups according to their growth patterns. The highest and lowest estimated values for asymptotic body weight (C) for 3H and 5W were given by von Bertalanffy and Logistic model 4629.7 g for 2197.8 g respectively. The highest estimated parameter for maturating rate (b) was given by Logistic model 0.249 corresponds to the 2F and lowest in von Bertalanffy model 0.094 for 4Y. According to the coefficient of determination ($R^2$) and mean square of error (MSE), Gompertz and von Bertalanffy models were suitable to describe the growth of Korean native chicken. Moreover, von Bertalannfy model was well described the most of KNC growth with biologically meaningful parameter compared to Gompertz model.

NOX 및 NH3 Slip 저감을 위한 Urea-SCR 제어기반 모델 개발 및 검증 (Development and Validation of Urea- SCR Control-Oriented Model for NOX and NH3 Slip Reduction)

  • 이승근;이성욱;강연식
    • 대한기계학회논문집B
    • /
    • 제39권1호
    • /
    • pp.1-9
    • /
    • 2015
  • 디젤 자동차의 점점 강화되는 $NO_X$ 배기가스 규제를 만족하기 위해서는 화학공학 기반의 SCR 반응모델을 사용한 모델기반 제어 알고리즘 개발이 필요하다. 본 연구에서는 소형 경유차량을 대상으로 $NO_X$ 를 저감하기 위한 배기 후처리 시스템 모델을 설계하기 위하여 SCR 시스템 모델링과 Rig 실험 및 Matlab 을 이용하여 시뮬레이션 및 검증을 하였다. SCR Rig 실험은 디젤엔진에서 배출되는 배기가스와 같은 성분의 모사가스를 생성하여 공간속도와 온도의 변화에 의한 SCR 의 $NO_X$ 저감효율에 대한 실험 조건 및 데이터를 획득하였다. 또한, 제안된 모델은 Rig 실험에서 사용한 실험조건과 결과데이터를 이용하여 Matlab 을 통해 검증하였으며 시뮬레이션 시 필요한 모델의 파라미터 값들은 실험데이터를 기반으로 최적화하였다.

비선형(非線型) 생장함수(生長函數)를 이용(利用)한 임분생장(林分生長) 추정(推定) (Stand Growth Estimation Using Nonlinear Growth Equations)

  • 손영모;이경학;정영교
    • 한국산림과학회지
    • /
    • 제86권2호
    • /
    • pp.135-145
    • /
    • 1997
  • 본 연구의 목적은 잣나무인공림과 신갈나무천연림에 있어 직경, 수고 및 재적생장을 설명할 수 있는 비선형생장식(非線形生長式) 추정과 이들 식의 논리적 타당성을 검정하기 위한 것이다. 이를 위해 전국에 분포한 지위지수 14인 임분에서 조사한 자료를 가지고 수확표 조제시 사용하였던 곡선식(曲線式) $Y=at^be^{-c/t}$와 9가지 비선형생장식(非線形生長式)을 적용, 분석하였으며 그 결과를 요약하면 다음과 같다. 먼저 수확표에서 사용된 곡선식은 자료범위내에서는 잘 적합시키고 있지만, 범위 이상에서는 직선적인 증가를 보이고 또 점근선(漸近線)을 가지고 있지 않아 과대치를 줄 위험이 있다. 비선형식중 Logistic식과 Sloboda식은 어린 임분에 있어 과대추정치를 나타내고 있는데 이는 식의 구조상 원점을 지나지 않기 때문이다. 또 이들 식은 타 식에 비하여 조기에 점근선에 도달하는 것으로 나다났다. 그리고 Gompertz식과 Ueno-Ohzaki식도 원점을 지나지 않는 식의 구조를 가지고 있다. 또한 Hossfeld식은 전반적으로 자료범위 이상의 임령에서는 여타 비선형식보다 큰 추정치를 주는데 이는 도달할 수 있는 최대치를 나타내는 모수 a값의 추정치가 크기 때문이다. 따라서 이 식은 범위 이상의 추정시 과대치를 주기 쉽다. 반면 Bertalanffy식은 임분의 유령기(幼齡基)와 노령기(老齡期)에서는 과소치, 그리고 그 사이에서는 과대추정치를 주고 있어, 식의 적용이 부적당한데, 이는 이 식이 동물의 생장추정을 위하여 개발된 것이기 때문이다. Korf식은 잣나무임분 생장추정시 노령기에 있어 과대추정치를 주는 경향이 있으며, 이는 신갈나무의 직경생장 추정시 확연하게 나타나고 있다. Ueno-Ohzaki식은 식의 구조상 모수 b에 따라 자료범위 밖의 노령기에 있어 직선적 상승 또는 조기 점근에 도달하고 있어 과대 휴은 과소치를 주기 쉽다. 전반적으로 잣나무와 신갈나무임분의 생장추정식으로는 Gompertz식, Chapman-Richards식 및 Weibull식이 현 자료범위 뿐만 아니라 범위밖의 유령림이나 노령림에 있어서도 가장 바람직한 식이라고 판단된다. 그리고 임목의 생장이란 시간이 지남에 따라 sigmoid curve를 그러므로 추후 생장식 도출에 있어서는 기존의 직선 및 곡선식보다 비선형식에 의한 것이 타당할 것이며, 앞으로 비선형식의 모수 추정, 특히 최대값인 모수 a의 정확한 추정을 위해서는 노령림에 대한 자료의 보완이 요구된다.

  • PDF

돼지의 Leptin receptor 유전자내 초위성체 다형성에 따른 개체별 성장곡선 특성 (Characteristics of Individual Growth Curve by Porcine LEPR-derived Microsatellite Polymorphisms)

  • 조용민;최봉환;김태헌;이지웅;정일정
    • Journal of Animal Science and Technology
    • /
    • 제45권6호
    • /
    • pp.885-890
    • /
    • 2003
  • 본 연구는 재래돼지와 랜드레이스 품종을 기초축으로 조성한 F2 집단의 일령별 체중 자료를 이용하여 비선형 회귀에 의해 추정한 개체별 성장곡선 모수 및 성장 특성치에 대한 LEPR 관련 초위성체 표지인자의 다형성에 따른 효과를 추정함으로써 Leptine 수준에 따른 성장 형질의 특성을 규명하고자 실시하였다. 조사된 F2 집단에 대해 개체별 성숙체중(A)과 성숙률(k)의 평균은 각각 179.69${\pm}$4.40kg 및 0.3103${\pm}$0.0043으로 추정되었으며, 성장 특성에 대한 성의 효과는 통계적 유의성이 없었으며 (p〉.05), 성숙체중(A) 및 최대 증체 속도($\partial$W$_{t1}$/$\partial$t)는 분만 그룹에 따른 유의적인 차이를 보였다(p〈.05). 조사된 모든 성장특성에 대해 LEPR 표지인자의 다형성 효과는 유의적으로 나타났으며(p〈.05), AA 유전자형을 가지는 개체는 만숙성이며, 반면 유전자형이 DD인 경우, 조사된 유전자형들 가운데 초기 성장이 빠른 조숙성의 성장 특성으로 가지지만, 성장률의 증가추세가 일찍 감소하며, 성숙체중의 최대치는 낮을 것을 추정되었다. 따라서 조사된 LEPR 관련 표지인자 유전자형의 다형성에 따른 성장 특성의 해석 및 예측이 가능하며, 그 범위는 생애 전반에 걸쳐 적용해야 할 것으로 사료된다.

타원곡선 암호시스템을 위한 GF(2$^{m}$ )상의 비트-시리얼 나눗셈기 설계 (Design of a Bit-Serial Divider in GF(2$^{m}$ ) for Elliptic Curve Cryptosystem)

  • 김창훈;홍춘표;김남식;권순학
    • 한국통신학회논문지
    • /
    • 제27권12C호
    • /
    • pp.1288-1298
    • /
    • 2002
  • 타원곡선 암호시스템을 GF(2$^{m}$ )상에서 고속으로 구현하기 위해서는 빠른 나눗셈기가 필요하다. 빠른 나눗셈 연산을 위해선 비트-패러럴 구조가 적합하나 타원곡선 암호시스템이 충분한 안전도를 가지기 위해서는 m의 크기가 최소한 163보다 커야 한다. 즉 비트-패러럴 구조는 0(m$^2$)의 면적 복잡도를 가지기 때문에 이러한 응용에는 적합하지 않다. 따라서, 본 논문에서는 CF(2$^{m}$ )상에서 표준기저 표기법을 사용하여 모듈러 나눗셈 A(x)/B(x) mod G(x)를 고속으로 수행하는 새로운 비트-시리얼 시스톨릭 나눗셈기를 제안한다. 효율적인 나눗셈기 구조를 얻기 위해, 새로운 바이너리 최대공약수(GCD) 알고리즘을 유도하고, 이로부터 자료의존 그래프를 얻은 후, 비트-시리얼 시스톨릭 나눗셈기를 설계한다. 본 논문에서 제안한 나눗셈기는 0(m)의 시간 및 면적 복잡도를 가지며, 연속된 입력 데이터에 대하여, 초기 5m-2 사이클의 지연 후, m 사이클 마다 나눗셈의 결과를 출력한다. 제안된 나눗셈기를 동일한 입출력 구조를 가지는 기존의 연구 결과들과 비교 분석한 결과 칩 면적 및 계산 지연시간 모두에 있어 상당한 개선을 보인다. 따라서 제안된 나눗셈기는 적은 하드웨어를 사용하면서 고속으로 나눗셈 연산을 수행할 수 있기 때문에 타원곡선 암호화시스템의 나눗셈 연산기로 매우 적합하다. 또한 제안한 구조는 기약 다항식(irreducible polynomial) 선택에 있어 어떤 제약도 두지 않고, 단 방향의 신호흐름을 가지면서, 매우 규칙적이기 때문에 필드 크기 m에 대해 높은 유연성 및 확장성을 제공한다.였다. an extraction system, a new optical nonlinear joint transform correlator(NJTC) is introduced to extract the hidden data from a stego image in real-time, in which optical correlation between the stego image and each of the stego keys is performed and from these correlation outputs the hidden data can be asily exacted in real-time. Especially, it is found that the SNRs of the correlation outputs in the proposed optical NJTC-based extraction system has been improved to 7㏈ on average by comparison with those of the conventional JTC system under the condition of having a nonlinear parameter less than k=0.4. This good experimental results might suggest a possibility of implementation of an opto-digital multiple information hiding and real-time extracting system. 촉각에 있는 지각신경세포가 뇌의 촉각엽으로 뻗어 들어가 위의 5가지 신경연접중 어느 형을 형성하는지를 관찰하기 위하여 좌측 촉각의

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF