• Title/Summary/Keyword: Nonlinear load

Search Result 2,235, Processing Time 0.034 seconds

A Study on Theoretical Analysis for Reinforced Concrete Transfer Girder of Hybrid Structures (복합구조의 철근콘크리트 전이보에 대한 이론적 해석 연구)

  • 권기혁;이춘호;김민수;이한선;고동우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.623-628
    • /
    • 2000
  • In this paper, the behavior for transfer girder of the upper-wall and lower-frame structures was studied by the nonlinear finite element analysis. It was analyzed and compared with the experimental results. Analysis results showed that failure modes were progressed by a initial diagonal crack in the shear span between the edges of the load and intermediate support plate. The nonlinear finite element analysis could predict deformation, principal stress, ultimate load and concrete crack. Also analysis results showed good agreement the test results.

  • PDF

비선형 다변수 발사대의 LQG/LTR 제어기 설계

  • 김종식;한성익;김용목;남세규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.133-142
    • /
    • 1992
  • A kineamatic nonlinear multivariable laundher is modeled of which the azimoth and elevation axes are drived simultaneously and SISO and MIMO LQG/LTR controllers are designed and evaluated for this system. Also, the suitable command input function is suggested for the desired command following performance and the LQG/LTR control system with disturbances and load variation is evaluated for the entire operating range by computer simulation. It is found that the linear SISO LQG/LTR controller can be used for the kinematic nonlinear multivariable launder in the entire operating range and is effective for disturbance rejection and load variation.

Algorithm for Economic Load Dispatch by the Nonlinear Programming Method (비선형계획법에 의한 자동경제급전 알고리즘의 개발에 관한 연구)

  • 박영문;김건중
    • 전기의세계
    • /
    • v.26 no.1
    • /
    • pp.77-81
    • /
    • 1977
  • This paper aims to develope a new algorithm to overcome the disadvantages of the conventional E.L.D system based on the B-Constants and Penalty-Factors scheme. The main features of this paper are that the Variabiable Decoupled Method usually employed in the Load-Flow studies is introduced to the E.L.D. algorithm developed by Sasson, using the Powell's Nonlinear Programming Scheme. Besides this, other minor refinements are made to reduce memory spaces and computing time. Case studies show that the method suggested here has the remarkable advantages of computing efficiency and memory requirements over Sasson's.

  • PDF

A Study on the Evaluation Methods of the Load-Carrying Capacity of PSC I Type Girder Considering Material Nonlinear (재료 비선형을 고려한 PSC I형 거더교의 내하력평가 기법에 관한 고찰)

  • 심종성;김규선;문도영;주민관
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.187-192
    • /
    • 2003
  • Nowadays, It has adapted both Ultimate Strength Design(USD) and Allowable Stress Design(ASD) Method evaluating load-carrying capacity of PSC I Type Girder Bridge. But it has confused because the each method has brought some different results. This study shows some results of loading test of the PSC I type Girder Bridge and analyzed the structural behavior by FEM analysis considering material nonlinear. Parametric study of effective prestress of post tendon is performed and compared to results of loading test.

  • PDF

A Comparative Analysis of Dynamic Instability Characteristic of Geiger-Typed Cable Dome Structures by Load Condition (Geiger형 케이블 돔 구조물의 외력에 따른 동적 불안정 특성 비교분석)

  • Kim, Seung-Deog;Sin, In-A
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.1
    • /
    • pp.85-91
    • /
    • 2014
  • The purpose of this paper is to study comparative of dynamic instability characteristic of Geiger-typed cable dome structures by load condition, which is well-known among the cable dome structures that are the lightweight hybrid structure using compression and tension element continuously. Dynamic buckling process in the phase plane is very important thing for understanding why unstable phenomena are sensitively originated in nonlinear dynamic by various initial conditions. But there is no paper for the dynamic instability of hybrid cable dome by Sinusoidal Excitations, many papers which deal with the dynamic instability for shell-structures under the step load have been published. As a result of Geiger-typed cable dome, which shows chaotic behavior in dynamic nonlinear analysis with initial imperfection.

The Phenomena Giving Rise of Nonlinear Load Operated by Unbalance Voltage (불평형 전압으로 운전시 비선형 부하에 나타나는 현상)

  • Kim, Jong-Gyeom;Lee, Eun-Ung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.285-291
    • /
    • 2002
  • In general, utility voltage is maintained at a relatively low level of Phase unbalance since a low level of unbalance can cause a significant power supply ripple and heating effects on the power system equipment. Voltage unbalance more commonly emerges in individual customer loads due to phase load unbalanced, especially where single phase power loads are used. Under unbalanced input voltages large lower order harmonics appears at the input and output ports of Power conversion devices. As the application of adjustable -speed drives (ASDs) and their integration with complex industrial processes increase, so does the need to understand how ASDs perform during voltage This paper describes a real load test to investigate the performance of 3-HP adjustable speed drives by an unbalanced voltage at the low-voltage system.

PID Autotuning Based on Saturation Function Feedback with A Static Load Disturbance (정적 부하왜란이 있는 경우의 포화함수를 이용한 PID 자동동조)

  • Oh, Seung- Rohk
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.12
    • /
    • pp.542-548
    • /
    • 2002
  • We consider an unknown linear time invariant plan with static load disturbance. A saturation function nonlinear element is sued to find th one point information in the frequency domain. We analyze an asymmetric self-oscillation caused by static load disturbance with relay feedback and saturation function feedback. We propose a new method to tune a PID controller using a saturation nonlinear feedback element in the presence of asymmetric oscillation. The proposed method does not require the knowledge of plant d.c. gain with an asymmetric oscillation in the plat output.

Analysis of power quality using non-linear load at low voltage system (저압 시스템에서 비선형 부하의 사용에 따른 전력품질 해석)

  • Kim, Jong-Gyeum;Lee, Eun-Woong;Sohn, Hong-Kwan;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.660-662
    • /
    • 2001
  • This paper describes the problems generated with the use of PWM ASDs with induction motors. The major effect of harmonic voltages and currents in induction motors is increased the heating due to iron and copper losses at harmonic frequencies. The harmonic components thus affect the motor efficiency and developed the torque. In order to investigate the effect of harmonics which is caused by using of nonlinear load at the low voltage system, we set up simple load system and measured the voltage and current. Measurement results show that additional operation of induction motor at the parallel bus in using nonlinear load such as ASD is helpful to the reduction of harmonic current.

  • PDF

Real Time Digital Control of PWM Inverter for Uninterruptible Power Supply(UPS) application (무정전 전원공급장치 적용을 위한 PWM 인버터의 Digital 실시간 제어)

  • Min, Wan-Ki;Lee, Sang-Hun;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.11a
    • /
    • pp.56-60
    • /
    • 1999
  • This paper presents the high performance real time control system of PWM inverter for uninterruptible power supply(UPS). This system is based on a digital control scheme which calculates the pulse widths of the inverter switches for the next sampling time in digital signal processor(DSP). A PI compensator is used to eliminate the voltage error caused by the difference between the actual values of LC filter and those designed. Double regulation loops which are the inner current loop and the outer voltage loop are used to make the transient response time reduce in load disturbance and nonlinear load. This method makes it possible to obtain better response in comparison to conventional digital control system. The proposed scheme provides good performance such as stable operation, low THD of the output voltage, and good dynamic response for load variations and nonlinear load.

  • PDF

A Study on the Behavior of Cylindrical Shell Structure Subjected to Axial Compression (축압축력을 받는 원통형 축대칭 쉘구조의 거동에 관한 연구)

  • 조현영;정진환;황상필
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1997.10a
    • /
    • pp.249-253
    • /
    • 1997
  • A numerical method for evaluating the equilibrium path of cylindrical shell subject to axial load and eccentrically axial load is presented. The effects of both material and geometric nonlinearities were also considered in the analysis. The nonlinear formulation was based on the total Lagrangian description and nonlinear equtions were solved by the Newton-Raphson method with load increment procedures. Degenerate shell elements with layered approach were employed for the analysis. The elasto-plastic deformation can be found in several examples and a large eccentricity of the axial load reduces the stress level at the time of the local buckling of the pipe considerably.

  • PDF