• 제목/요약/키워드: Noise insulation

검색결과 448건 처리시간 0.027초

소형 창문의 차음성능 측정에 관한 고찰 (Measurement of sound Insulation of small-size windows)

  • 김상렬;강현주;김재승;김현실;김봉기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.942-945
    • /
    • 2006
  • In order to measure the sound transmission loss(STL) of a test specimen such as windows, which is smaller than the test opening, a special partition is built into the test opening and the specimen is placed in that partition. This paper discusses how the measured STL is changed by the partition when a small-size window of high sound insulation is mounted. Theoretical and experimental investigations are carried out to quantify the effect of the filler wall. The results reveal that the smaller the window size is, the higher sound insulation performance of the filler wall is required in order to measure the accurate STL of the specimen. It is found that the insufficient sound insulation of the filler wall leads to the lower measured value of the window's STL.

  • PDF

현장에서의 창의 차음성능 측정방법에 관한 실험적 연구 (An Experimental Study on the Field Measurement Methods of the Sound Insulation Performance of Window)

  • 이옥균;박현구;최형욱;송혁;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.600-605
    • /
    • 2000
  • The aim of this study is to compare the sound insulation performances of window depending on the measurement methods through the field test and analyze the factors that affect the sound insulation performances. Four measurement methods which are specified in the Koran Standard 2235 and the International Standard 140-5 were selected for the study; the outdoor sound source method which is classified the l000mm method and the 10mm method, the indoor sound source method, and the ISO method. The result of this study is that the sound insulation performance of the windows was the best when measured according to the ISO method and the worst the indoor sound source method. Through the study it was found that the main factors affecting the sound insulation performance of the windows were the correction of the specimen's area and the equivalent sound absorption area of the receiving room.

  • PDF

틸팅열차 측면재의 차음 전략 (Sound Insulation Strategy of the Side Panels in a Tilting Train)

  • 김석현;서태건
    • 산업기술연구
    • /
    • 제31권A호
    • /
    • pp.33-38
    • /
    • 2011
  • In an express tilting train, side wall insulating the noise from the exterior sound source consists of two parts. One is the layered composite panel including aluminum honeycomb, glass wool and nomex honeycomb. The other is the double glazed window. In this study, sound insulation performance of the two parts is investigated by mass law and experiment. Based on ASTM E2249-02, the intensity sound transmission loss (TL) is measured on the specimens of the two parts. Mass law deviation (MLD) is considered in order to compare the sound insulation performance in respect of weight. Contribution of each part to the sound insulation is analyzed and the sound insulation strategy for the interior noise reduction is investigated.

  • PDF

경량콘크리트 패널의 차음성능에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Performance for Light-weight Concrete Panel)

  • 정진연;이성호;정갑철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.457-460
    • /
    • 2004
  • This study examines the sound insulation of the light-weight wall using light-weight concrete and offers the basic datum for enhancing it. The sound insulation of the light-weight wall is determinated by the density, installation method, absorption materials, air layers etc. Among the factors, the solution of outlet that is the major cause of reducing sound insulation should be made. If absorption materials are installed in the cavity walls, it enhances to 15dB in 500Hz.

  • PDF

경량충격음 차단성능 실험실 측정방법 고찰 (A Survey on the Laboratory Measurements of Impact Sound Insulation of Floors)

  • 송민정;장길수;고성석;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.976-979
    • /
    • 2004
  • The KS of 'Laboratory Measurement of Impact Sound Insulation of Floors' is not established yet. To establish this KS, present conditions of domestic laboratory test facilities for measuring impact sound insulation of floors in laboratory and current researches were reviewed As a result the outline of 'Laboratory Measurement of Impact Sound Insulation of Floors' is suggested.

  • PDF

A Novel Fast Open-loop Phase Locking Scheme Based on Synchronous Reference Frame for Three-phase Non-ideal Power Grids

  • Xiong, Liansong;Zhuo, Fang;Wang, Feng;Liu, Xiaokang;Zhu, Minghua;Yi, Hao
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1513-1525
    • /
    • 2016
  • Rapid and accurate phase synchronization is critical for the reliable control of grid-tied inverters. However, the commonly used software phase-locked loop methods do not always satisfy the need for high-speed and accurate phase synchronization under severe grid imbalance conditions. To address this problem, this study develops a novel open-loop phase locking scheme based on a synchronous reference frame. The proposed scheme is characterized by remarkable response speed, high accuracy, and easy implementation. It comprises three functional cascaded blocks: fast orthogonal signal generation block, fast fundamental-frequency positive sequence component construction block, and fast phase calculation block. The developed virtual orthogonal signal generation method in the first block, which is characterized by noise immunity and high accuracy, can effectively avoid approximation errors and noise amplification in a wide range of sampling frequencies. In the second block, which is the foundation for achieving fast phase synchronization within 3 ms, the fundamental-frequency positive sequence components of unsymmetrical grid voltages can be achieved with the developed orthogonal signal construction strategy and the symmetrical component method. The real-time grid phase can be consequently obtained in the third block, which is free from self-tuning closed-loop control and thus improves the dynamic performance of the proposed scheme. The proposed scheme is adaptive to severe unsymmetrical grid voltages with sudden changes in magnitude, phase, and/or frequency. Moreover, this scheme is able to eliminate phase errors induced by harmonics and random noise. The validity and utility of the proposed scheme are verified by the experimental results.

창호일체형 환기장치의 소음분석 및 저감방안 (Noise Analysis and Reduction Methods of the All-in One Window Ventilation System)

  • 박찬재;한찬훈
    • 한국음향학회지
    • /
    • 제32권1호
    • /
    • pp.43-55
    • /
    • 2013
  • 최근 창호의 창틀에 폐열회수장치를 삽입한 일체형 환기장치인 일명 "창호일체형 폐열회수 환기장치"를 개발됨으로써 창문을 열지 않고도 에너지 손실을 최소화하면서 실내외 공기를 교환할 수 있게 되었다. 그러나 이 장치의 작동시 기계소음과 공력소음이 발생하여 실제 주거시설에 적합하지 않은 면이 있다. 따라서 본 연구에서는 창호일체형 환기장치의 소음을 설치상태와 무향실에서 측정하고 소음의 발생 원인과 소음전달 취약부분을 분석하였다. 또한, 창호일체형 환기장치내의 차음재와 흡음재를 설치하여 소음을 제어하기 위한 대안을 제시하였다. 연구결과, 환기장치의 소음원은 블로워로 나타났으며 소음의 주된 누출 원인은 환기장치 구조체의 낮은 차음성능 때문이었음을 알 수 있었다. 또한 이를 제어하기 위하여 장치 내부에 고무시트 등의 차음재를 설치한 결과 폐열회수환기장치의 소음기준인 40 dBA 이하를 만족함을 알 수 있었다.

농용 트랙터의 안전캡 내부 소음 감소에 관한 연구(II) -소음 감소 효과- (A Case Study on Inside Noise Reduction of Agricultural Tractor Cab(II) -Noise Reduction-)

  • 유동호;김경욱;최창현
    • Journal of Biosystems Engineering
    • /
    • 제20권2호
    • /
    • pp.127-132
    • /
    • 1995
  • In the first part of this paper, an analysis of the cab noise of a selected agricultural tractor was presented. In this study, using the results of the previous analysis, two passive noise control measures of the sound insulation and absorption were conducted to reduce the noise level inside the cab. These measures of noise control reduced the total noise level by 6.2㏈(A) at the operator position inside the cab. In order to further reduce the cab noise, particularly, of lower frequencies than 630Hz, stiffness and damping of the floor panel should be enforced. It was also suggested that a proper suspension for the cab mounting is necessary to reduce the level of structure-born noises.

  • PDF

벽체 우회전달음 영향요소에 관한 연구 (A Study on the Factor of Flanking Noise in the Wall)

  • 정진연;정갑철
    • 한국소음진동공학회논문집
    • /
    • 제17권2호
    • /
    • pp.143-148
    • /
    • 2007
  • This study examines the influence factor of flanking noise in the wall. Generally, there is the difference of airborne sound isolation between laboratory and field test. The purpose of this study is examing the cause of droping sound insulation performance in the field and searching the method of improving sound insulation performance. First, we measured the sound isolation in the wall at the lab. Then, we measured it in the field and compared them. At the base of these datum, we measured the flanking noise and solid transmission. For the flanking noise in the wall, we used intensive method. So, we found the influence of solid transmission.

공동주택의 층별 도로교통 소음의 전달 특성에 관한 연구 (A Study on the Floor-Specific Characteristics of Road Traffic Noise in Apartment Buildings)

  • 함진식
    • 한국주거학회논문집
    • /
    • 제19권1호
    • /
    • pp.1-8
    • /
    • 2008
  • This study is an attempt to understand the floor-specific characteristics of facade road traffic noise in apartment buildings. For this purpose, it sampled a total of seven roadside apartment building complexes: three with no soundproof bar barrier installed at roadside, one with a forest buffer zone, one with a sound-absorbing hill, and two with soundproof barriers. The measured noise level was highest on the 5th floor of apartment buildings with no soundproof barrier, and the upper stories from the 5th floor showed lower-noise measurements in order. For apartment buildings with soundproof barriers, however, the noise level was lower on the 10th floor than the 5th floor. Two apartment building groups--one with a sound-absorbing hill and the other with no soundproof barrier--showed similar measurement results in the floor-specific characteristics of facade road traffic noise. This suggests that such installations have little sound insulation effect. In the apartment building complex with a forest buffer zone around it, a slight sound insulation effect was measured on the lower floors of the buildings.