• Title/Summary/Keyword: Noise Rating

Search Result 155, Processing Time 0.03 seconds

Comparison of Rating Methods for the Floor Impact Noise (바닥충격음 평가방법 중 단일수치평가량과 dB(A) 비교)

  • Park, Cheol-Yong;Jang, Dong-Woon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.612-615
    • /
    • 2006
  • In this study, we compared and analyzed the floor impact noise insulation performance produced by the rating methods. The rating methods are using reversed A-weighting curve, A-weighted sound pressure levels(dB(A)). The results of this study are(1)dB(A) by the specified frequency is 0.5dB(A) at light weight and 2.5dB(A) at heavy weight upper than all pass dB(A)(2)the rating using reversed A-weighting curve is 5dB lower than dB(A)(3)the number of rating using reversed A-weighting curve mainly depends on impact noise pressure level of 63Hz in heavy weight but dB(A) does not.

  • PDF

Sound Absorption Performance of Noise Barrier According to Single Number Rating Methods (단일수치 평가방법에 따른 방음벽의 흡음성능 고찰)

  • Kim, Yonghee;Lee, Sungchan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.2
    • /
    • pp.243-250
    • /
    • 2017
  • In this study, single number rating methods of sound absorption coefficients are discussed. After that the sound absorption performance of noise barriers which are classified by Korea Standard are analyzed according to several standards. The existing rating methods such as NRC (noise reduction coefficient), SAA (sound absorption average) or ${\alpha}_w$ (weighted sound absorption coefficient) from ASTM C423, KS F 3505 and ISO 11654 are introduced. The sound absorption performance of noise barrier is evaluated to compare NRC and ${\alpha}_w$ value. When the value is over 0.6 there are large variance between NRC and ${\alpha}_w$ value. As results, it is needed to unify single number rating methods of sound absorption coefficients for Korean standards on sound absorbing materials.

An active noise control window system to reduce noise rating in low frequency band (저주파 대역의 소음 평가 지수 개선을 위한 창문형 능동 소음 제어기)

  • Oh, Wongeun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.331-337
    • /
    • 2018
  • In this paper, we apply the NR (Noise Rating) to the evaluation of the residual noise of the window type ANC (Active Noise Control) and study the active noise controller for minimizing the NR value in rooms. We proposed a shape of a noise shaping filter of the Filtered-E LMS (Least Mean Square) algorithm that reduces the NR value within the effective operating frequency band of the ANC. The usefulness of the proposed scheme is verified by simulation and showed that the NR value of the residual noise is lower than the filters used in the conventional psychoacoustic ANC.

A Study on the Establishment of the Environmental Noise Criteria for Aircraft (항공기 소음 환경 기준 설정을 위한 연구)

  • Kim, Sun-Woo;Jang, Gil-Soo;Lee, Soo-Gab;Song, Min-Jeong;Chang, Se-Myong;Jeon, Ji-Hyun;Ahn, Byung-Og
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.6
    • /
    • pp.420-430
    • /
    • 2002
  • Rating scales for environmental noise are varied in their calculation procedure. Among them WECPNL (weighted equivalent continuous perceived noise level) is the rating scale for aircraft noise currently being used in domestic and applied only for aircraft noise. However $L_{dn}$ calculated from $L_{eq}$ $L_{eq}$ is used as a rating scale for not only aircraft noise but also environmental noise. Besides, it is easy to calculate and internationally preferred. It is, therefore, not adequate for the evaluation of residents' exposure. Moreover it is very difficult to measure the aircraft noise by WECPNL due to the complicated calculating procedures if automatic measuring system is not used. Accordingly. this study aims to propose alternative evaluation procedure for the aircraft noise. To achieve this purpose, the data measured by automatic measuring system were gathered and calculated with three evaluation procedures : WECPNL $L_{eq}$ and $L_{dn}$, and the results calculated from different methods were compared and analyzed.

A Combined Rating System for Multiple Noises in Residential Buildings (공동주택 복합 생활소음의 통합 평가등급)

  • Ryu, Jong-Kwan;Jeon, Jin-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1005-1013
    • /
    • 2006
  • A survey and auditory experiment on multiple residential noises such as floor impact, airborne, bathroom, drainage and traffic noises were conducted to develop a combined rating system and to establish criteria for multiple residential noises. Subjective reactions such as annoyance, activity disturbance, sleep disturbance, and satisfaction to overall noise environment and each residential noise were recorded. The effect of individual noise perception on the evaluation of the overall noise environment was also investigated. The survey results showed that satisfaction for floor impact noise most greatly affects the overall satisfaction for overall noise environment and annoyance most greatly affects the satisfaction for individual noise sources. Auditory experiments were undertaken to determine the percent satisfaction for individual noise levels. Result of auditory experiment showed that the noise level corresponding to 40 % satisfaction is 49 dB $(L_{i,Fmax,AW})$ for floor impact and is about 40 dB(A) for airborne, drainage and traffic noise. From the results of the survey and the auditory experiments, an equation for predicting the overall satisfaction for multiple noises was developed and a classification of multiple residential noises was proposed.

Subjective Assessment of Simulated Heavy Floor Impact Sounds for Alternative Rating Method (현행 중량바닥충격음 평가방법 개선을 위한 주관평가실험)

  • Shin, Hoon;Back, Geon-Jong;Song, Min-Jeong;Jang, Gil-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.581-586
    • /
    • 2008
  • This study aims to examine the existing single rating index in terms of level reduction limit of heavy-weight floor impact sound. To achieve this goal, sounds which have same loudness according to rating methods were suggested to subjects. And followings are results. 1) The rating method of measurement frequency level average is more suitable than that of other methods which are dependent on specific frequency for rating heavy-weight floor impact sound. 2) Level average for measurement frequency of 31.5Hz - 500Hz is more correspondent to psycho-acoustic response than that of measurement frequency of 63Hz - 500Hz which is for KS F 2863-2, existing rating method.

  • PDF

Korean Industrial Standard of “Rating of floor impact sound insulation for impact source in building and of building elements” (바닥충격음 차단성능 평가방법의 KS 규격화 방안)

  • 송민정;장길수;김흥식;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.383-386
    • /
    • 2001
  • The KS of “Measurements of impact sound insulation of floors” was established before the years. But the KS of “Rating of floor impact sound insulation for impact source in building and of building elements” is not founded yet. To establish the rating measurement of floor impact sound insulation. The studies on the rating method of domestic floor system of impact sound insulation and response of its inhabitant’s were reviewed. And the rating method of ISO’s and JIS’s were studied in this consideration. The result of this study, KS of “Rating of floor impact sound insulation for impact source in building and of building elements” is proposed.

  • PDF

Subjective Assessment of Simulated Heavy Floor Impact Sounds for Alternative Rating Method (현행 중량바닥충격음 평가방법 개선을 위한 주관평가실험)

  • Shin, Hoon;Kim, Sun-Woo;Jang, Gil-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.3
    • /
    • pp.282-287
    • /
    • 2009
  • This study aims to examine the existing single rating index in terms of level reduction limit of heavy-weight floor impact sound. To achieve this goal, sounds which have same loudness according to rating methods were suggested to subjects. And followings are results. 1) The rating method of measurement frequency level average is more suitable than that of other methods which are dependent on specific frequency for rating heavy-weight floor impact sound. 2) Level average for measurement frequency of $31.5\;Hz{\sim}500\;Hz$ is more correspondent to psycho-acoustic response than that of measurement frequency of $63\;Hz{\sim}500\;Hz$ which is for KS F 2863-2, existing rating method.

An experimental study on the rating of noise emission from water supply and drain installations in apartment bathroom (공동주택 욕실 급배수음 평가방법 제정방안에 관한 실험적 연구)

  • Lee, Tai-Gang;Song, Min-Jeong;Jang, Gil-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.5-10
    • /
    • 2006
  • This study aims to propose appropriate evaluating method of noise emission from water supply and drain installations in apartment bathroom. Because KS(Korean Standard) about water installations noise in apartment bathroom only are establishing the measurement procedure of it, Evaluation and rating procedure is necessary to improve the sound insulation performance of the apartment and to reduce the apartment dweller's unsatisfaction with the noise. Thus, this study reviewed the standards and evaluating methods about the water supply and drain installations noise of many other country. We measured the noise emission from the installations in many apartment bathroom, and then we calculated the noises to dB(A), N, NC evaluated numbers. We analyze the coefficient of the corelation among the evaluated numbers to induce the appropriate method. As a result, the dB(A) method is most easy to evaluateing and very high corelated wth N and N index, So the dB(A) method is suitable to be adopted KS evaluating procedure of noise emission from water installations in apartment bathroom.

  • PDF

Comparison of Rating Methods for the Floor Impact Sound Insulation Performance (바닥충격음 차단성능 평가방법의 상호비교)

  • Kim, Kyoung-Woo;Choi, Hyun-Jung;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.291-294
    • /
    • 2005
  • In this study, we compared and analyzed the floor impact sound insulation performance produced by the rating methods. The rating methods are using reversed A-weighting curve, A-weighted sound pressure levels and arithmetic average. On-site floor impact sound pressure levels of living room and room are measured. The results of this study are 1)the rating using reversed A-weighting curve for heavy-weight impact sound's standard deviation is lower than that of light-weight impact sound, 2)the number of rating using A-weighted sound pressure levels and arithmetic average is larger than that of using reversed A-weighting curve, and 3)the number of rating using reversed A-weighting curve mainly depends on impact sound pressure level of 63Hz in heavy-weight impact sound.

  • PDF