• 제목/요약/키워드: Nitrogen ion implanted steel

검색결과 13건 처리시간 0.029초

금형공구강의 표면성질 향상에 미치는 질소이온주입의 효과에 관한 연구 (A Study on Effect of Nitrogen Ion Implantation on Improvement of Surface Properties of Tool Steel)

  • 김화정;김용조
    • 한국기계가공학회지
    • /
    • 제7권4호
    • /
    • pp.3-9
    • /
    • 2008
  • The ion implantation technology is generally used in order to improve surface mechanical properties, especially tribological properties, of engineering metals. In this study, experimental works were carried out to investigate the surface properties, such as hardness, wear quantity, wear rate and friction force, of a nitrogen ion implanted tool steel STD11 under dry condition. Specimens for the wear test were made to investigate the influences of the initial ion implantation temperature and the total ion radiation. Wear properties, such as the wear quantity and the wear rate, of the nitrogen ion implanted tool steel were considerably improved, especially under the low sliding speed and the low applied load.

  • PDF

질소 이온주입된 AiSi 316L 스테인리스강 소결체의 공식거동 (Pitting Corrosion Behavuor of N2+ ion Implanted AISI 316L Stainless Steel Compacts)

  • 최한철
    • 한국표면공학회지
    • /
    • 제31권2호
    • /
    • pp.73-80
    • /
    • 1998
  • The aim of this study is to develop sintered stainless steels (SSS) with good mechanical strength, wear resistance, and corrosion resistance by nitrogen ion implantation on the Culated SSS surface. Stainless steel compacts containg Cu (2-10 wt%) were prepared by electroless Cu-pating method which results in the increased3 homogenization in alloying powder. Nitrogen ion implantation was carried out by using N2 gas as the ion source. Nitrogen ions were embedded by an acceleratol of 130keV with doese $3.0\times10^{17}\;ions/\textrm{cm}^2$ on the SSS at $25^{\circ}C$ in$2\times10^{-6}$ torr vacuum. The nitrogen ion implanted SSS obtained from anodic ploarization curves revealed higher corrosion potential than that of nitrogen ion unimplante one. And nitrogen ion implanted 316LSSS had good resistance to pitting corrosion due to the synergistic effect of Mo and N, and the inhibition of $NH_4\;^+$<\TEX>, against $CI^-$<\TEX>.

  • PDF

고온 이온주입된 크롬강의 표면특성변화 (The change of surface properties of nitrogen implanted chromium steel in high temperature environment)

  • 이찬영;김범석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.403-403
    • /
    • 2008
  • This article reports changes in the mechanical properties of chromium steel after nitrogen implantation at high temperature. The samples are implanted with 120keV N-ion at doses ranging from $1\times1080$ to $4\times1080ions/cm^2$ and at substrate temperature ranging from 25 to $400^{\circ}C$. Nano-hardness and AES(Auger electrons spectroscopy) were measured from nitrogen ion implanted layer. The sliding wear and impact wear properties of the implanted samples were also measured. The results revealed that the hardness and mechanical properties of ion implanted samples depend strongly on the ion doses and implantation temperature. The hardness of the nitrogen implanted sample with 120keV, $4\times10^{18}ions/cm^2$, $335^{\circ}C$ was measured to be approximately 20 GPa, which is approximately 5 times higher than that of un-implanted sample (H=3.8 GPa). Also, the sliding wear and impact wear properties of nitrogen implanted samples were greatly improved. Detailed experiment results will be presented.

  • PDF

질소 이온이 주입된 STS 316L 스테인리스 강에서의 상변화와 집합조직이 내식성에 미치는 영향 (Influence of Phase Evolution and Texture on the Corrosion Resistance of Nitrogen Ion Implanted STS 316L Stainless Steel)

  • 전신희;공영민
    • 한국재료학회지
    • /
    • 제25권6호
    • /
    • pp.293-299
    • /
    • 2015
  • In this study, nitrogen ions were implanted into STS 316L austenitic stainless steel by plasma immersion ion implantation (PIII) to improve the corrosion resistance. The implantation of nitrogen ions was performed with bias voltages of -5, -10, -15, and -20 kV. The implantation time was 240 min and the implantation temperature was kept at room temperature. With nitrogen implantation, the corrosion resistance of 316 L improved in comparison with that of the bare steel. The effects of nitrogen ion implantation on the electrochemical corrosion behavior of the specimen were investigated by the potentiodynamic polarization test, which was conducted in a 0.5 M $H_2SO_4$ solution at $70^{\circ}C$. The phase evolution and texture caused by the nitrogen ion implantation were analyzed by an X-ray diffractometer. It was demonstrated that the samples implanted at lower bias voltages, i.e., 5 kV and 10 kV, showed an expanded austenite phase, ${\gamma}_N$, and strong (111) texture morphology. Those samples exhibited a better corrosion resistance.

질소이온주입된 초내식성 스테인리스강의 마모부식 특성 (Wear Corrosion Behaviour of Nitrogen Ion Implanted Super Stainless Steel)

  • 강선화;김철생
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.175-177
    • /
    • 1994
  • The wear corrosion behaviour of a nitrogen ion implanted super stainless steel (S.S.S, 22Cr - 20Ni - 6Mo - 0.25N) was compared with those of S.S.S, 316L SS and TiN coated 316L SS. The Cr and Ni amounts won out from the materials were investigated using an electrothermal atomic absorption spectrometry. We observed that the Cr dissolution rate of the S.S.S was similar to that of 316L SS, however, the Ni release of the S.S.S was feater than 316L SS. The metal ions released from the nitrogen ion implanted S.S.S surface were significantly reduced. The wear corrosion behaviour of the stainless steels was not correlated with the results shown by a static metal ion release test.

  • PDF

Surface modification and induced ultra high surface hardness by nitrogen ion implantation of low alloy steel

  • Olofinjana, A.O.;Bell, J.M.;Chen, Z.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.157-158
    • /
    • 2002
  • A surface hardenable low alloy carbon steel was implanted with medium energy (20 - 50KeV) $N_2^+$ ions to produced a modified hardened surface. The implantation conditions were varied and are given in several doses. The surface hardness of treated and untreated steels were measured using depth sensing ultra micro indentation system (UMIS). It is shown that the hardness of nitrogen ion implanted steels varied from 20 to 50GPa depending on the implantation conditions and the doses of implantation. The structure of the modified surfaces was examined by X-ray photoelectron spectroscopy (XPS). It was found that the high hardness on the implanted surfaces was as a result of formation of non-equilibrium nitrides. High-resolution XPS studies indicated that the nitride formers were essentially C and Si from the alloy steel. The result suggests that the ion implantation provided the conditions for a preferential formation of C and Si nitrides. The combination of evidences from nano-indentation and XPS, provided a strong evidence for the existence of $sp^3$ type of bonding in a suspected $(C,Si)_xN_y$ stoichiometry. The formation of ultra hard surface from relatively cheap low alloy steel has significant implication for wear resistance implanted low alloy steels.

  • PDF

고분자전해질 연료전지 분리판용 316L 스테인리스강의 표면특성에 미치는 질소 이온주입 효과 (Effects of Nitrogen Ion Implantation on the Surface Properties of 316L Stainless Steel as Bipolar Plate for PEMFC)

  • 김민욱;김도향;한승희;김유찬
    • 대한금속재료학회지
    • /
    • 제47권11호
    • /
    • pp.722-727
    • /
    • 2009
  • The bipolar plates are not only the major part of the polymer electrolyte membrane fuel cell (PEMFC) stack in weight and volume, but also a significant contributor to the stack costs. Stainless steels are considered to be good candidates for bipolar plate materials of the PEMFC due to their low cost, high strength and easy machining, as well as corrosion resistance. In this paper, 316L stainless steel with and without nitrogen ion implantation were tested in simulated PEMFC environments for application as bipolar plates. The results showed that the nitride formed by nitrogen ion implantation contributed the decrease of the interfacial contact resistance without degradation of corrosion property. The combination of excellent properties indicated that nitrogen ion implanted stainless steel could be potential candidate materials as bipolar plates in PEMFC. Current efforts have focused on optimizing the condition of ion implantation.

질소이온 코팅 SCM415강의 마찰.마모특성에 관한 연구 (A Study on the Friction and Wear Characteristics of Nitrogen Ions Coated SCM415 Steel)

  • 류성기;하위파;손유선
    • Tribology and Lubricants
    • /
    • 제23권1호
    • /
    • pp.14-18
    • /
    • 2007
  • SCM415 alloy was implanted with nitrogen ions using plasma source ion implantation (PSII), at a dose range of $1{\times}10^{17}\;to\;6{\times}10^{17}N^{+}cm^{-2}$. Auger electron spectrometry (AES) was used to investigate the depth profile of the implanted layer. Friction and wear tests were carried out on a block-on-ring wear tester. Scanning electron microscopy (SEM) was used to observe the micro-morphology of the worn surface. The results revealed that after being implanted with nitrogen ions, the frictional coefficient of the surface layer decreased, and the wear resistance increased with the nitrogen dose. The tribological mechanism was mainly adhesive, and the adhesive wear tended to become weaker oxidative wear with the increase in the nitrogen dose. The effects were mainly attributed to the formation of a hard nitride precipitate and a supersaturated solid solution of nitrogen in the surface layer.

Corrosion resistance of a carbon-steel surface modified by three-dimensional ion implantation and electric arc.

  • Valbuena-Nino, E.D.;Gil, L.;Hernandez, L.;Sanabria, F.
    • Advances in materials Research
    • /
    • 제9권1호
    • /
    • pp.1-14
    • /
    • 2020
  • The hybrid method of three-dimensional ion implantation and electric arc is presented as a novel plasma-ion technique that allows by means of high voltage pulsed and electric arc discharges, the bombardment of non-metallic and metallic ions then implanting upon the surface of a solid surface, especially out of metallic nature. In this study AISI/SAE 4140 samples, a tool type steel broadly used in the industry due to its acceptable physicochemical properties, were metallographically prepared then surface modified by implanting titanium and simultaneously titanium and nitrogen particles during 5 min and 10 min. The effect of the ion implantation technique over the substrate surface was analysed by characterization and electrochemical techniques. From the results, the formation of Ti micro-droplets upon the surface after the implantation treatment were observed by micrographs obtained by scanning electron microscopy. The presence of doping particles on the implanted substrates were detected by elemental analysis. The linear polarization resistance, potentiodynamic polarization and total porosity analysis demonstrated that the samples whose implantation treatment with Ti ions for 10 min, offer a better protection against the corrosion compared with non-implanted substrates and implanted at the different conditions in this study.

플라즈마 질소 이온주입한 오스테나이트 스테인레스 강의 표면특성 (Surface Properties of Plasma Nitrogen Ion Implanted Stainless Steel)

  • 김광훈;;이홍식;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2253-2255
    • /
    • 1999
  • Plasma source ion implantation (PSII) is a non-line-of-sight technique for surface modification of materials which is effective for non-planar targets. Properties such as hardness, corrosion resistance, wear resistance and friction can be improved without affecting the bulk properties of the material. Type 304 austenitic stainless steel was treated by nitrogen plasma ion implantation at a target bias of -50kV. Surface properties, including microhardness and ion depth profile, were studied.

  • PDF