• Title/Summary/Keyword: Nitrocellulose membrane

Search Result 54, Processing Time 0.024 seconds

Detection of Waterborne Pathogens in Public Bath Houses by PCR-Reverse Blot Hybridization Assay (PCR-REBA) (분자생물학적 방법인 PCR-REBA를 이용한 대중목욕탕 수질 중 수인성병원성미생물 검출)

  • Song, Woon-Heung;Choi, Seung-Gu;Yang, Byoung-Seon;Lee, Jae-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3517-3522
    • /
    • 2011
  • Contamination of public bath water by waterborne pathogens can cause disease outbreaks and contribute to background rates of disease. The aim of this study is to determine the prevalence of waterborne pathogens in public baths. A total of 30 water samples were collected from 30 different public baths in seoul, Korea. Pathogens in water samples were concentrated by 0.45 ${\mu}m$ nitrocellulose membrane filter, analyzed by both cultivation and polymerase chain reaction-reverse blot hybridization (PCR-REBA) of partial 16S rRNA gene. Various microorganisms including Escherichia coli and Shigella spp. were identified by microbiological cultivation. E. coli, Shigella spp., Salmonella spp., Pseudomonas spp. and Mycobacterium spp. were identified by PCR-REBA. Our results suggest that appropriate hygiene practice and continuous monitoring is needed for reducing health risk associated with public bath houses.

One-Step Simultaneous Immunochromatographic Strip Test for Multianalysis of Ochratoxin A and Zearalenone

  • Shim, Won-Bo;Dzantiev, Boris B.;Eremin, Sergei A.;Chung, Duck-Hwa
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.1
    • /
    • pp.83-92
    • /
    • 2009
  • Individual immunochromatographic assays (ICG) for ochratoxin A (OTA) and zearalenone (ZEA) were optimized and used in the development of a one-step simultaneous immunochromatographic assay (OS-ICG) for the rapid multianalysis of two mycotoxins in corn samples. The nitrocellulose membrane of the OS-ICG was treated with OTA-bovine serum albumin (BSA), ZEA-ovalbumin (OVA), and anti-mouse IgG in the OTA test, ZEA test, and control zones, respectively. Monoclonal antibody-gold conjugates (OTA3 MAb-gold and ZEA2C5 MAb-gold) were sprayed onto the conjugate pad. The visual detection limits were 2.5 and 5 ng/ml for OTA and ZEA, respectively, and the results were obtained within 15 min after starting the analysis. An efficient, simple, and rapid extraction method using 30% MeOH/PBS was established and validated by analyzing the corn samples spiked with OTA/ZEA mixtures (0/0, 5/10, 10/20, and $20/30\;{\mu}g/kg$). The cut-off values of the OS-ICG for the spiked corn were 5 and $10\;{\mu}g/kg$ for OTA and ZEA, respectively. Natural corn samples were analyzed by OS-ICG, direct competitive enzyme-linked immunosorbent assay (DC-ELISA), and HPLC. Results of the OS-ICG were in good agreement with those obtained by DC-ELISA and HPLC. The developed OS-ICG offers a rapid, easy-to-use, and portable analytical system and can be used as a convenient qualitative tool for the on-site simultaneous determination of OTA and ZEA in cereals, food, and agricultural products in one analytical cycle.

Immunochromatographic Strip Assay for Detection of Cronobacter sakazakii in Pure Culture

  • Song, Xinjie;Shukla, Shruti;Lee, Gibaek;Kim, Myunghee
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.11
    • /
    • pp.1855-1862
    • /
    • 2016
  • Cronobacter sakazakii (C. sakazakii) is a foodborne pathogen, posing a high risk of disease to infants and immunocompromised individuals. In order to develop a quick, easy, and sensitive assay for detecting C. sakazakii, a rabbit anti-C. sakazakii immunoglobulin G (IgG) was developed using sonicated cell protein from C. sakazakii. The developed anti-C. sakazakii (IgG) was of good quality and purity, as well as species-specific. The developed rabbit anti-C. sakazakii IgG was attached to the surface of a sulforhodamine B-encapsulated liposome to form an immunoliposome. A test strip was then prepared by coating goat anti-rabbit IgG onto the control line and rabbit anti-C. sakazakii IgG onto the test line, respectively, of a plastic-backed nitrocellulose membrane. A purple color signal both on the test line and the control line indicated the presence of C. sakazakii in the sample, whereas purple color only on the control line indicated the absence of C. sakazakii in the sample. This immunochromatographic strip assay could produce results in 15 min with a limit of detection of $10^7CFU/ml$ in C. sakazakii culture. The immunochromatographic strip assay also showed very good specificity without cross-reactivity with other tested Cronobacter species. Based on these results, the developed immunochromatographic strip assay is efficient for the detection of C. sakazakii and has high potential for on-site detection.

A Comparison of Two Methods for the Extraction of Lactoferrin-binding Proteins from Streptococcus uberis (Streptococcus uberis의 락토페린 결합단백질 추출을 위한 두 가지 방법의 비교)

  • Park, Hee-Myung;Yoo, Jong-Hyun;Almeida, Raul A.;Oliver, Stephen P.
    • Journal of Veterinary Clinics
    • /
    • v.24 no.3
    • /
    • pp.305-307
    • /
    • 2007
  • Lactoferrin-binding proteins (LBP) has not been well characterized in Streptococcus uberis isolated from milk of bovine mastitis and to date this protein is considered to be an important virulence factor in Streptococcal mastitis. To determine the more efficient extraction method of LBP from four S. uberis strains, we used two different extraction methods (mutanolysin and sodium dodecyl sulfate) in this study. Bacterial proteins extracted were electrophoresed by 10% polyacrylamide gels in the presence of sodium deodecyl sulfate and gels were transferred onto nitrocellulose membrane. Rabbit anti-bovine lactoferrin antibody and HRP-conjugated donkey anti-rabbit IgG antibody were used to detect LBP. This Western blotting analysis demonstrates that extraction method with SDS extracted 110 kDa and 112 kDa LBPs more efficiently compared to the mutanolysin extraction method.

Development and Clinical Evaluation of a Rapid Serodiagnostic Test for Toxoplasmosis of Cats Using Recombinant SAG1 Antigen

  • Chong, Chom-Kyu;Jeong, Woo-Seog;Kim, Hak-Yong;An, Dong-Jun;Jeoung, Hye-Young;Ryu, Jeong-Eun;Ko, A-Ra;Kim, Yong-Joo;Hong, Sung-Jong;Yang, Zhaoshou;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.49 no.3
    • /
    • pp.207-212
    • /
    • 2011
  • Rapid serodiagnostic methods for Toxoplasma gondii infection in cats are urgently needed for effective control of transmission routes toward human infections. In this work, 4 recombinant T. gondii antigens (SAG1, SAG2, GRA3, and GRA6) were produced and tested for the development of rapid diagnostic test (RDT). The proteins were expressed in Escherichia coli, affinity-purified, and applied onto the nitrocellulose membrane of the test strip. The recombinant SAG1 (rSAG1) showed the strongest antigenic activity and highest specificity among them. We also performed clinical evaluation of the rSAG1-loaded RDT in 182 cat sera (55 household and 127 stray cats). The kit showed 0.88 of kappa value comparing with a commercialized ELISA kit, which indicated a significant correlation between rSAG1-loaded RDT and the ELISA kit. The overall sensitivity and specificity of the RDT were 100% (23/23) and 99.4% (158/159), respectively. The rSAG1-loaded RDT is rapid, easy to use, and highly accurate. Thus, it would be a suitable diagnostic tool for rapid detection of antibodies in T. gondii-infected cats under field conditions.

Enzyme-linked Immunosorbent Assay Strip Sensor for Rapid Detection of Staphylococcus aureus (Staphylococcus aureus 신속 검출을 위한 효소면역측정 스트립 센서)

  • Park, So Jung;Kim, Young-Kee
    • Applied Chemistry for Engineering
    • /
    • v.22 no.5
    • /
    • pp.522-525
    • /
    • 2011
  • In this study, an established enzyme-linked immunosorbent assay and immuno-chromatography technique are combined to fabricate an immuno-strip sensor for the detection of S. aureus. The immuno-strip is manufactured by using four different functional membranes. The capture antibody is immobilized on the nitrocellulose membrane due to the high affinity and the capillary action through porous membranes induces a flow of sample. A colorimetric signal is appeared according to the enzyme reaction and is analyzed by the digital camera (qualitative analysis) and home-made image analysis software (quantitative analysis). Under the optimal conditions, samples with S. aureus in the range of $2.7{\times}10^4{\sim}2.7{\times}10^7CFU/mL$ can be detected by the colorimetric method within 30 min.

Studies on sterile filters in the preparation of N-13 ammonia injection (N-13 암모니아 주사액 제조 시 멸균필터의 흡착율 차이에 관한 비교 평가)

  • Oh, Chang Bum;Kim, Si Hwal;Cha, Min Jung;Shin, Jin;Ji, Yong Gi;Choi, Sung Ook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.64-68
    • /
    • 2019
  • Purpose In the preparation process for N-13 Ammonia injections, there were radioactive medicines adsorbed on filters remarkably. Hereby, we have compared the adsorption rate and quality test on Millex GS filter and Satorious Minisart filter, both representatively hydrophilic sterilizing filters, also evaluated which filter is more accommodative for N-13 Ammonia injection. Materials and Methods The filters used for sterilization of N-13 Ammonia injections were Millex GS filter($0.22{\mu}m$) mand Satorious Minisart filter ($0.2{\mu}m$), which are generally used to strain aqueous solutions. After the N-13 Ammonia passes through each sterilization filter, the adsorption rate of the filter (n=10) is determined by measuring not only the radioactivity through the filter also the amount of radioactivity remaining in it using a Dose Calibrator. The N-13 Ammonia injections after each filter is tested by the quality control test to conform to the Samsung Medical Center standard. Results The ratio of radioactivity passed through Millex GS indicated $29.0{\pm}17.6%$. Satorious Minisart filters output was $80.9{\pm}3.2%$, respectively. Each ratio of radioactivity adsorbed on the sterile filter was $71.0{\pm}17.6%$ for Millex GS and $19.1{\pm}3.2%$ for the Satorious Minisart filters, respectively. Furthermore, on the ratio of filtered radioactivity, Using Satorious Minisart filter showed about 2.8 times higher than using Millex GS filter. The quality testing of N-13 Ammonia injections through each filter met the Samsung Medical Center standard. Conclusion The Millex GS filter is composed of cellulose acetate and cellulose nitrate, whereas the Satorious Minisart filter if composed only of cellulose acetate. Therefore, the presence of cellulose nitrate in the membrane seems to have made differences. Therefore, the use of Satorious Minisart filter in the preparation of N-13 Ammonia injection solution minimized the loss of radioactive medicines due to filter adsorption, thereby improving the synthesis yield.

Characterization of the Expression of PKCα(Isoform) in DMH-induced Vascular Endothelial Proliferation (DMH에 의한 비정상적인 혈관 내피세포의 증식에서 Protein Kinase C 동종효소 Alpha 단백발현의 특성)

  • Nam, Su Bong;Bae, Yong Chan;Park, Suk Young;Choi, Soo Jong
    • Archives of Plastic Surgery
    • /
    • v.34 no.6
    • /
    • pp.679-684
    • /
    • 2007
  • Purpose: DMH(1,2-dimethylhydrazine) has been known to induce vascular neoplasm such as malignant endothelioma in animal experiment, through induction of abnormal proliferation of HUVECs. In our previous studies, 11 types of PKC isoenzymes were determined by RT-PCR and the expression of $PKC{\alpha}$, and ${\mu}$ was more prominent than other PKC isoenzymes in the DMH-treated group. However, this result was not based on objective assessment. In this study, we further evaluated the role of $PKC{\alpha}$ on the DMH-induced abnormal proliferation of HUVECs by two different methods to identify its presence with high relevance in objective view. $PKC{\mu}$ will be investigated in further study. Methods: The study was conducted with the cultured HUVECs group(control) and the $0.75{\times}10^{-9}M$ DMH-treated group. After processing protein extraction in 0 and 24 hour, extracted protein was treated of quantitative test through BCA protein assay. In the western blot analysis, electrophoresis was performed in the order of gel preparation, sample preparation, and gel running. Electrotransfer to nitrocellulose membrane and reaction with antibody were done. Detection of $PKC{\alpha}$ was achieved through "Gel Image Analysis System". In the fluorescence immunocytochemical analysis, the grading of radiance of the intracellular $PKC{\alpha}$ particles was detected with confocal microscope after treating with primary and fluorescent secondary antibody in 0 and 24 hours. Results: The Western blot analysis showed increased $PKC{\alpha}$ expression from the specimen obtained in 24 hour of the DMH treatment group when compared to those in control group. Under confocal fluorescence microscope, the emitting radiance in the DMH treated group was brighter at 24 hours as well. Conclusion: We believe that $PKC{\alpha}$ plays a role in DMH-induced abnormal proliferation of the vascular endothelium, which may provide insights in understanding the vascular neoplasm.

COMPARISON OF SALIVARY ANTIBODY IgA TITRE TO STREPTOCOCCUS MUTANS BETWEEN THE CARIES-EXPERIENCED AND NON-EXPERIENCED GROUPS USING IMMUNO-SLOT BLOT METHOD (Immuno-slot blot method를 이용한 우식 경험 아동과 비경험 아동간의 Streptococcus mutans에 대한 타액내 IgA 역가의 비교)

  • Eum, Jong-Hyeok;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.354-361
    • /
    • 2002
  • The aim of this study is to develop and establish rapid, convenient, and accurate method of analyzing salivary IgA against S. mutans semi-quantitatively. Relative salivary IgA titer was calculated as maximum dilution fold of S. mutans protein that was not detected by salivary antibody after measuring relative intensity of the immune blot bands by densitometry. Analyses were performed in caries-experienced and non-experienced children. Mean IgA titer of non-experienced group shows higher level than that of caries-experienced without statistical significance due to high individual variety of antibody titer in non-experienced group: $2^{6.278{\pm}2.260}$ in non-experienced group and $2^{5.730{\pm}0.499}$ in caries-experienced group(p=0.464). Those results suggest that naturally induced salivary IgA antibodies against S. mutans were present in all subjects, but high titer of antibodies were not achieved in caries-experienced group. On the contrary, antibody titer in non-experienced group shows marked individual variations suggesting that antibody production is multifactorial. In conclusion, immune-slot blot method developed in this study would be useful and applicable in semi-quantitative analysis of antibodies.

  • PDF

Analysis of Human Serum Amyloid A-1 Concentrations Using a Lateral Flow Immunoassay with CdSe/ZnS Quantum Dots (Human Serum Amyloid A-1 단백질 농도 분석을 위한 CdSe/ZnS 양자점 기반의 Lateral Flow Immunoassay 방법 개발)

  • Fajri, Aidil;Goh, Eunseo;Lee, Sanghyuk;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.429-434
    • /
    • 2019
  • A lateral flow immunoassay platform utilizing antibody functionalized water soluble CdSe/ZnS semiconductor quantum dots (QDs) was developed for the analysis of human serum amyloid A-1 (hSAA1) in a buffer solution. hSAA1 was chosen as a target protein because it is regarded as a potential biomarker associated with early diagnosis and prognosis in patients of lung cancer. The immunoassay strip on a nitrocellulose membrane was fabricated by spraying two lines composed of a test line with a monoclonal antibody against hSAA1 (10G1) (anti hSAA1) and a control line of anti-chicken IgY. While the CdSe/ZnS QDs synthesized in an organic phase were transferred to a water phase by ligand exchange using carboxylic acid modified alkane thiol. The QDs was then conjugated to monoclonal antibody against hSAA1 (14F8) [anti hSAA1 (14F8)] and used as a fluorescent detection probe. The sequential lateral flow of hSAA1 in different concentration and QDs-anti hSAA1 (14F8) complex allowed to form the surface sandwich complex of anti hSAA1 (10G1)/hSAA1/QD-anti hSAA1 (14F8), which was then analyzed using fluorescence microscope. A 100 nM concentration of hSAA1 protein can be detected by naked eyes under an optimized lateral flow buffer condition with a sensing time of 5 mins.