• 제목/요약/키워드: Nickel-titanium rotary file

검색결과 49건 처리시간 0.024초

Effect of adaptive motion on cyclic fatigue resistance of a nickel titanium instrument designed for retreatment

  • Ozyurek, Taha;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • 제42권1호
    • /
    • pp.34-38
    • /
    • 2017
  • Objectives: The aim of this study was to evaluate the cyclic fatigue resistance of the ProTaper Universal D1 file (Dentsply Maillefer) under continuous and adaptive motion. Materials and Methods: Forty ProTaper Universal D1 files were included in this study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which had an artificial stainless steel canal with a $60^{\circ}$ angle of curvature and a 5 mm radius of curvature. The files were randomly divided into two groups (Group 1, Rotary motion; Group 2, Adaptive motion). The time to failure of the files were recorded in seconds. The number of cycles to failure (NCF) was calculated for each group. The data were statistically analyzed using Student's t-test. The statistical significant level was set at p < 0.05. Results: The cyclic fatigue resistance of the adaptive motion group was significantly higher than the rotary motion group (p < 0.05). Conclusion: Within the limitations of the present study, the 'Adaptive motion' significantly increased the resistance of the ProTaper Universal D1 file to cyclic facture.

모형 레진근관에서 근관의 만곡도가 니켈-티타늄 전동 파일의 screw-in effect에 미치는 영향 (Influence of root canal curvature on the screw-in effect of nickel-titanium rotary files in simulated resin root canal)

  • 손지영;하정홍;김영경
    • Restorative Dentistry and Endodontics
    • /
    • 제35권5호
    • /
    • pp.374-379
    • /
    • 2010
  • 연구목적: 근관의 만곡도가 니켈-티타늄 전동파일의 screw-in effect에 미치는 영향을 평가하고자 하였다. 연구 재료 및 방법: 0, 10, 20, 그리고 30도의 만곡을 가지는 80개의 레진모형근관 (Nissin Dental Prod. Inc.)에서 0.06 경사도 30번 전동화일 (ProTaper, Dentsply-Maillefer)을 분당 300회전, 단일 pecking 동작으로 기구조작하였으며 dynamometer를 이용하여 발생한 screw-in force를 측정하였다. 결과치는 one-way ANOVA로 통계처리 하였고, Scheffe multiple range test를 사용하여 95% 수준에서 유의성을 검정하였다. 결과: 근관의 만곡도가 작을수록 screw-in force가 높게 나타났으며 (p < 0.001), 모든 그룹 간에 유의성 있는 차이를 보였다. 결론: 이 결과로 미루어 볼 때, 근관의 만곡도가 작을수록 screw-in force가 많이 발생하는 것으로 보여지며, 따라서 기구조작 동안의 screw-in force를 방지 또는 억제하기 위해서는 만곡도가 작은 근관을 성형할 때 더 많은 주의가 요구될 것으로 생각된다.

근관치료 기구의 기계 형태적 특성과 이에 따른 임상적 영향 고찰 (Mechanical and geometric features of endodontic instruments and its clinical effect)

  • 김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제36권1호
    • /
    • pp.1-11
    • /
    • 2011
  • 서론: 이 문헌의 목적은 Nickel-titanium (NiTi) 전동 파일의 기계적 형태적 양상과 이에 의한 임상적 연관성을 고찰하는 것이다. NiTi 전동 파일은 다양한 고유의 형태로 시장에 소개되었고 경쟁 상품에 비해서 근관 성형에 더 나은 능력을 가졌다고 주장하고 있다. 본론: 이 문헌에서는 NiTi 전동 파일의 형태(예. 팁, 테이퍼, helical angle 등)와 파일의 임상 적용 성과 사이의 가능한 상관관계를 다음과 같이 다룬다; - NiTi 전동 파일의 파절 양상 - 비활성 파일팁과 glide path - 파일 경사도와 임상 효과 - 파일 횡단면적과 임상 효과 - 열처리와 표면 특성 - Screw-in 효과와 치근 상아질의 유지 - Screw-in 효과를 줄이기 위한 고안 결론: 이상의 내용을 바탕으로, 임상가는 다양한 NiTi 전동 기구를 사용함에 있어 임상 상황에 적절한 장점을 고려하여 선택하고 사용할 수 있는 도움을 받을 수 있을 것이다.

니켈티타늄 전동 파일의 기계적 특성 비교: Aurum Blue vs. Aurum Pro (Comparison of mechanical properties of nickel-titanium rotary files: Aurum Blue vs. Aurum Pro)

  • 곽상원;하정홍;안상미;김현철
    • 대한치과의사협회지
    • /
    • 제57권11호
    • /
    • pp.672-678
    • /
    • 2019
  • AIM: The purpose of this study was to evaluate and compare the torsional fracture resistances, cyclic fatigue resistance, and bending stiffness of two nickel-titanium (NiTi) rotary instruments made of different heat-treated alloy: Aurum Blue (heat-treated) and Aurum Pro (conventional). Methods: Forty-five Aurum Blue and Aurum Pro NiTi files were selected for the three mechanical tests (n=15). For the torsional resistance test, 3 mm file tip was fixed and the shaft was driven clockwise at 2 rpm until fracture occurred by using a customized device. Cyclic fatigue resistance was evaluated by rotating instruments in artificial canal with dynamic mode. Bending stiffness was tested by observation of the bending moment on attaining a 45° bend. The results were analyzed by student-t tests at a significance level of 95%. The fractured surface of each groups were examined under a scanning electron microscope (SEM). Results: Aurum Blue showed significantly higher toughness, ultimate strength, distortion angle, and number of cycles to failure than those of Aurum Pro (p < 0.05). However, Aurum Blue and Aurum Pro did not differ significantly in terms of bending stiffness. SEM showed typical topographic appearances of the cyclic fatigue and torsional fracture. Conclusions: Under the limitations of this study, heat-treated instruments showed higher flexibility and fracture resistances than conventional NiTi instruments.

  • PDF

Glide path 형성용 니켈티타늄 회전 파일의 효율: in-vitro 예비 연구 (Efficiency of the nickel-titanium rotary instruments for glide path preparation: in-vitro preliminary study)

  • 김현철;곽상원;하정홍
    • 대한치과의사협회지
    • /
    • 제55권10호
    • /
    • pp.688-694
    • /
    • 2017
  • Objectives: This preliminary study compared the effects of glide path establishing instruments prior to substantial root canal preparation. Materials and Methods: Glide path was established by enlargement of the 2nd mesiobuccal root canal of Dentalike by using three kinds of glide path preparation nickel-titanium file; PathFile, One G and ProGlider. The pre- and post-instrumented Dentalikes were weighed in the resolution of 1 / 10mg. In addition, after glide path preparation, torque generated during shaping using the WavoOne file was measured. The data were analyzed by one-way ANOVA and Tukey post-hoc test at a significance level of 95%. Results: The ProGlider had the significantly larger amount of reduced weight than other instrument groups (p < 0.05). There was no significant difference between group of glide path preparation with ProGlider and without glide path preparation in maximum torque and total stress generation during the shaping with WaveOne. Conclusions: Glide path preparation instruments may have different efficiency according to their geometries. The Dentalike artificial teeth were revealed to have discrepancies in the size of root canals by microCT examination. It is impossible to make a meaningful judgment of the results due to the reliability or resolution problem of the root canal size of the artificial tooth selected as the standardized tooth.

  • PDF

근관 내 File의 파절 시 대처 방안 (MANAGEMENT OF SEPARATED FILE IN THE ROOT CANAL)

  • 김혜정;장훈상;박세희;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제31권3호
    • /
    • pp.161-168
    • /
    • 2006
  • 근관형성을 하는 과정에서 기구가 파절될 가능성은 언제나 존재한다. File을 비롯하여 lentulo spiral, Gates-Glidden (GG) bur 또는 여타의 이물질도 근관 내에 남겨질 수 있다. 근래에는 수동 file에 비해 많은 장점을 가지고 있는 회전식 nickel-titanium (NiTi) file의 사용이 보편화 되고 있으나 기구의 높은 파절 경향이 문제가 되고 있다. NiTi file의 파절은 매우 빠른 시간내에 일어나고 예측이 불가능하며 임상가에게 정신적 stress를 가져다. 주기 때문에 임상가로 하여금 niTi file의 사용을 주저하게 만들기도 한다. 근관 내 기구가 파절되면 제거하는 것이 가장 최선의 해결 방법이다. 초음파 기기와 미세 현미경의 사용으로 파절된 기구의 제거율이 높아지고 있지만 제거하는 것이 쉬운 일만은 아니며 항상 제거가 가능한 것도 아니다. 그러므로 예방이 최선의 방법이라 할 수 있다. 본 증례에서는 근관 내 file이 파절된 경우에 있어 여러 가지 대처 방안에 대해 보고하고자 한다.

Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments

  • Ozyurek, Taha;Tek, Vildan;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.332-341
    • /
    • 2017
  • Objectives: To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. Materials and Methods: The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with ${\chi}^2$ tests using SPSS 21.0 software. Results: New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. Conclusions: This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.

Effect of glide path preparation with PathFile and ProGlider on the cyclic fatigue resistance of WaveOne nickel-titanium files

  • Uslu, Gulsah;Inan, Ugur
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.22.1-22.8
    • /
    • 2019
  • Objectives: The aim of this study was to investigate the effect of glide path preparation with PathFile and ProGlider nickel-titanium (NiTi) files on the cyclic fatigue resistance of WaveOne NiTi files. Materials and Methods: Forty-four WaveOne Primary files were used and divided into four groups (n = 11). In the first group (0 WaveOne), the WaveOne Primary files served as a control group and were not used on acrylic blocks. In the 1 WaveOne Group, acrylic blocks were prepared using only WaveOne Primary files, and in the PF+WaveOne group and PG+WaveOne groups, acrylic blocks were first prepared with PathFile or ProGlider NiTi files, respectively, followed by the use of WaveOne Primary files. All the WaveOne Primary files were then subjected to cyclic fatigue testing. The number of cycles to failure was calculated and the data were statistically analyzed using one-way analysis of variance (ANOVA) and the Tukey honest significant difference multiple-comparison test at a 5% significance level. Results: The highest number of cycles to failure was found in the control group, and the lowest numbers were found in the 1 WaveOne group and the PF+WaveOne group. Significant differences were found among the 1 WaveOne, PF+WaveOne, and control groups (p < 0.05). No statistically significant differences were found between the PG+WaveOne group and the other three groups (p > 0.05). Conclusion: Glide path preparation with NiTi rotary files did not affect the cyclic fatigue resistance of WaveOne Primary files used on acrylic blocks.

Comparison of apical extrusion of intracanal bacteria by various glide-path establishing systems: an in vitro study

  • Dagna, Alberto;El Abed, Rashid;Hussain, Sameeha;Abu-Tahun, Ibrahim H;Visai, Livia;Bertoglio, Federico;Bosco, Floriana;Beltrami, Riccardo;Poggio, Claudio;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.316-323
    • /
    • 2017
  • Objectives: This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. Materials and Methods: Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). Results: The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups (p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. Conclusions: All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.

Micro-CT evaluation of the removal of root fillings using rotary and reciprocating systems supplemented by XP-Endo Finisher, the Self-Adjusting File, or Er,Cr:YSGG laser

  • Gulsen Kiraz;Bulem Ureyen Kaya;Mert Ocak;Muhammet Bora Uzuner;Hakan Hamdi Celik
    • Restorative Dentistry and Endodontics
    • /
    • 제48권4호
    • /
    • pp.36.1-36.15
    • /
    • 2023
  • Objectives: This study aimed to compare the effectiveness of a single-file reciprocating system (WaveOne Gold, WOG) and a multi-file rotary system (ProTaper Universal Retreatment, PTUR) in removing canal filling from severely curved canals and to evaluate the possible adjunctive effects of XP-Endo Finisher (XPF), the Self-Adjusting File (SAF), and an erbium, chromium: yttrium, scandium, gallium garnet (Er,Cr:YSGG) laser using microcomputed tomography (µCT). Materials and Methods: Sixty-six curved mandibular molars were divided into 2 groups based on the retreatment technique and then into 3 based on the supplementary method. The residual filling volumes and root canals were evaluated with µCT before and after retreatment, and after the supplementary steps. The data were statistically analyzed with the t-test, Mann-Whitney U test, analysis of covariance, and factorial analysis of variance (p < 0.05). Results: PTUR and WOG showed no significant difference in removing filling materials (p > 0.05). The supplementary techniques were significantly more effective than reciprocating or rotary systems only (p < 0.01). The supplementary steps showed no significant differences in canal filling removal effectiveness (p > 0.05), but XPF showed less dentin reduction than the SAF and Er,Cr:YSGG laser (p < 0.01). Conclusions: The supplementary methods significantly decreased the volume of residual filling materials. XPF caused minimal changes in root canal volume and might be preferred for retreatment in curved root canals. Supplementary approaches after retreatment procedures may improve root canal cleanliness.