• Title/Summary/Keyword: NiTi rotary file

Search Result 66, Processing Time 0.028 seconds

COMPARATIVE STUDY ON MORPHOLOGY OF CROSS-SECTION AND CYCLIC FATIGUE TEST WITH DIFFERENT ROTARY NITI FILES AND HANDLING METHODS (수종의 NiTi 전동 파일 단면 형태 비교 및 pecking motion의 사용방법이 피로 파절에 미치는 영향)

  • Kim, Jae-Gwan;Kum, Kee-Yeon;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2006
  • There are various factors affecting the fracture of NiTi rotary files. This study was performed to evaluate the effect of cross sectional area, pecking motion and pecking distance on the cyclic fatigue fracture of different NiTi files. Five different NiTi $files-Profile^{(R)}$ (Maillefer, Ballaigue, Switzerland), $ProTaper^{TM}$(Maillefer, Ballaigue, Switzerland), $K3^{(R)}$ (SybronEndo. Orange, CA) , Hero $642^{(R)}$ (Micro-mega, Besancon, France), Hero $Shaper^{(R)}$ (Micro-mega, Besancon, France)-were used. Each file was embedded in temporary resin, sectioned horizontally and observed with scanning electron microscope. The ratio of cross-sectional area to the circumscribed circle was calculated. Special device was fabricated to simulate the cyclic fatigue fracture of NiTi file in the curved canal,. On this device, NiTi files were rotated (300rpm) with different pecking distances (3 mm or 6 mm) and with different motions (static motion or dynamic pecking motion) . Time until fracture occurs was measured. The results demonstrated that cross-sectional area didn't have any effect on the time of file fracture. Among the files, $Profile^{(R)}$ took the longest time to be fractured. Between the pecking motions, dynamic motion took the longer time to be fractured than static motion. There was no significant difference between the pecking distances with dynamic motion, however with static motion, the longer time was taken at 3mm distance. In this study, we could suggest that dynamic pecking motion would lengthen the time for NiTi file to be fractured from cyclic fatigue.

COMPARISON OF SHAPING ABILITY OF ROTARY Ni-Ti FILE SYSTEMS USED BY UNDERGRADUATES (학생들이 사용한 엔진 구동형 Ni-Ti file systems의 근관 성형 효율 비교)

  • Kang, Mun-Seong;Kim, Hyeon-Cheol;Hur, Bock;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • The purpose of this study was to compare the shaping ability of three Ni-Ti file systems used by dental students or the experts and consequently to aid in choosing a proper systems for educational courses of dental students and beginners. Fifty students and ten dentists who have clinical experience over two years prepared 180 simulated root canals in resin blocks with three Ni-Ti systems; $ProFile^{(R)}\;(PF),\;HeroShaper^{(R)}\;(HS),\;K3^{TM}\;(K3)$. After preparation, the Ni-Ti files were evaluated for distortion and canal preparation time was recorded. The images of pre- and post-instrumented canals were scanned and superimposed. Amounts of increased canal widths, deviation, and centering ratio were calculated at apical 1, 3 and 5 mm levels and statistical analysis was performed The results were as follows : 1. HS showed the shortest preparation time and instrumented canal width in K3 was significantly larger than other groups (P<0.05). 2. At 1 and 3mm levels, all groups had outward deviation. In student group, at the 1mm level, PF had the least deviation (P<0.05). 3. In the centering ratio, the PF had the best centering ability compared to the others at 5mm level. At 1 and 3mm levels, HS and PF had better abilities than K3. Student group had better ratio than the expert at 3mm level with PF (P<0.05). Based on the results, it is surmised that the $ProFile^{(R)}$ is the safest and most ideal instrument for students and beginners.

Comparative analysis of various corrosive environmental conditions for NiTi rotary files (니켈티타늄 파일의 부식에 영향을 미치는 다양한 환경 조건 비교)

  • Yum, Ji-Wan;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.377-388
    • /
    • 2008
  • The aim of the present study is to compare the corrosion tendency using two kinds of NiTi files in the various environmental conditions through the visual examination and electrochemical analysis. ProTaper Universal S2, 21 mm (Dentsply Maillefer, Ballaigues, Switzerland) and Hero 642, 0.06 tapers, size 25, 21 mm (Micromega, Besancon, France) rotary instruments were tested. The instruments were randomly divided into eighteen groups (n = 5) by the immersion temperature, the type of solution, the brand of NiTi rotary instrument and the presence of mechanical loading. Each file was examined at various magnifications using Scanning Electron Microscope (JEOL, Akishima, Tokyo, Japan) equipped with energy dispersive X-ray microanalysis (EDX). EDX was used to determine the components of the endodontic file alloy in corroded and noncorroded areas. The corrosion resistance of unused and used NiTi files after repeated uses in the human teeth was evaluated electrochemically by potentiodynamic polarization test using a potentiostat (Applied Corrosion Monitoring, Cark-in-Cartmel, UK). Solution temperature and chloride ion concentration may affect on passivity of NiTi files. Under the conditions of this in vitro study, the corrosion resistance is slightly increased after clinical use.

MANAGEMENT OF SEPARATED FILE IN THE ROOT CANAL (근관 내 File의 파절 시 대처 방안)

  • Kim, Hye-Jeong;Jang, Hoon-Sang;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.161-168
    • /
    • 2006
  • During root canal preparation procedures, the potential for instrument separation is always present. Files, a lentulo, a Gates-Glidden (GG) bur or any manufactured obstruction can be left behind in the canal Nickel-titanium (NiTi) rotary files are in common usage in these days. Despite their undeniable advantages, there is a potential risk of separation within the canals. It is very rapid, unpredictable, and creates a great deal of stress for the practitioner. When an endodontic instrument separates, the best option is to remove it. Ultrasonic instruments and microscopes have improved the success rate for removing separated instruments. But It is difficult and not always possible. Therefore prevention is the key. In this case report, several management methods of separated file in the canal are presented.

A STUDY OF INSERTION DEPTH OF GUTTA PERCHA CONES AFTER SHAPING BY NI-TI ROTARY FILES IN SIMULATED CANALS (레진모형 근관에서 Ni-Ti 파일로 근관성형 후 거타퍼챠콘의 근관내 삽입깊이에 대한 연구)

  • Cho, Hyun-Gu;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.550-558
    • /
    • 2007
  • The purpose of this study was to evaluate the insertion depth of several brands of master gutta percha cones after shaping by various Ni-Ti rotary files in simulated canals. Fifty resin simulated J-shape canals were instrumented with ProFile, ProTaper and HEROShaper. Simulated canals were prepared with ProFile .04 taper #25(n=10), .06 taper #25(n=10), ProTaper F2(n=10), HEROShaper .04 taper #25(n=10) and .06 taper #25(n=10). Size #25 gutta percha cones with a .04 & .06 taper from three different brands were used: DiaDent; META; Sure-endo. The gutta percha cones were selected and inserted into the prepared simulated canals. The distance from the apex of the prepared canal to the gutta percha cone tip was measured by image analysis program. Within limited data of this study, the results were as follows 1. When the simulated root canals were prepared with HEROShaper, gutta-percha cones were closely adapted to the root canal. 2. All brands of gutta percha cones fail to go to the prepared length in canal which was instrumented with ProFile, the cones extend beyond the prepared length in canal which was prepared with ProTaper. 3. In canal which was instrumented with HEROShaper .04 taper #25, Sure-endo .04 taper master gutta percha cone was well fitted(p < 0.05). 4. In canal which was instrumented with HEROShaper .06 taper #25, META .06 taper master gutta percha cone was well fitted(p < 0.05). As a result, we concluded that the insertion depth of all brands of master gutta percha cone do not match the rotary instrument, even though it was prepared by crown-down technique, as recommended by the manufacturer. Therefore, the master cone should be carefully selected to match the depth of the prepared canal for adequate obturation.

Prevention and Solution of the Fracture of Nickel-Titanium Endodontic Instruments (니켈티타늄 전동파일 파절의 예방 및 처치)

  • Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.54 no.8
    • /
    • pp.640-650
    • /
    • 2016
  • Nickel-Titanium (NiTi) rotary instruments have brought a big step toward "efficient" practice of endodontic procedure. The rotary files help clinicians to reduce their working time and also increase the clinical success rate with minimal procedural errors. However, NiTi instruments still have a few drawbacks including unpredictable fatigue fracture. Clinicians may reduce the potential risk of instruments fracture by following some clinical guidelines for rotary instruments. In some clinical cases of instruments fracture, we may try to remove the instruments' fragments or bypass the fragment to reach the apical canal. In some limited cases, the fractured instruments' fragments would not jeopardize the clinical prognosis of root canal treatment. Nevertheless, it is impossible to be overemphasized that the prevention of file fracture is much easier than the removal of fracture fragment. Clinicians need to understand the fracture mechanisms and, in clinic, need to discard the used instruments timely.

  • PDF

Evaluation of canal preparation with Ni-Ti rotary files by micro computed tomography

  • Lee, Jeong-Ho;Kim, Mi-Ja;Seok, Chang-In;Lee, Woo-Cheol;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.4
    • /
    • pp.378-385
    • /
    • 2004
  • The purpose of this study was to compare the effects of preparation with GT files and profiles .04 in shaping of root canals and reconstruct the three-dimensional root canal system using micro computed tomography 40 canals of the extracted human mandibular molars were used, and randomly distributed into two experimental groups. In group 1. canals were prepared by GT files. In group 2, Profiles .04. were used. Apical preparation size was #30. For each tooth pre and post operative cross-sectional images were obtained by the micro CT at 50 micron intervals. Pre and post operative cross-sectional images of 1, 2, 3, 5, and 8mm from the apex were compared. For each section. canal area and centering ratio were determined. For each tooth pre- and post-operative root canal volume from the furcation to the apex of the roots was calculated by three-dimensional image software. Following results were obtained: 1. At 8mm from the apex, area of dentin removed by GT rotary file was significantly larger than that by Profile .04. And at the other levels there was not a significant difference. 2. There was a trend for GT rotary file to remain more centered in the canals than Profile .04 at all levels. But at 3mm level. there was a statistically significant difference. 3. In root canal volume increments after instrumentation, there was no significant difference between two groups.

THE EFFECT OF NiTi ROTARY INSTRUMENTATION ON THE CHANGE OF APICAL ROOT CANAL CURVATURE (NiTi Rotary Instrumentation이 근관만곡도 변화에 미치는 영향)

  • Lim, Hyoung-Tae;Hong, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.257-268
    • /
    • 1998
  • During cleaning and shaping of narrow and curved canals, it is very difficult or nearly impossible to maintain the original canal shape. Procedural accidents such as, ledge, zipping, perforation, and instrument breakage are frequently occurred and even may lead to failure of endodontic therapy. To prevent these kinds of accidents, various instrumentation techniques and materials have been introduced. Recently some nickel titanium (NiTi) files are introduced and it is reported that These NiTi files created rounder preparations with less transportation than conventional instruments in curved canals. This study compared the change of the canal curvature and procedural accidents after instrumentation produced by stainless steel K-flexo file, and NiTi rotary files (Profile 29 and Quantec 2000). Thirty narrow and curved canals (25-45 degree) of extracted human molars were randomly divided into three groups. In group 1, canals were instrumented using a step-back and watch-winding/pull motion with K-flexo files. In group 2, canals were prepared with Profile 29. Group 3, canals were prepared with Quantec 2000 files. Before and after preparation of canals, periapical radiographs were taken and scanned. The change of canal curvature were measured using Photoshop 4.0 program and the incidence of procedural accidents were also evaluated. The results were as follows: 1. All group showed some loss of canal curvature after instrumentation. 2. Average loss of canal curvature was $6.70{\pm}5.31$ degree for group 1, $3.80{\pm}2.57$ degree for group 2, and $5.40{\pm}4.83$ degree for group 3. All group There was significant change in curvature between before and after instrumentation (p<0.05). But there was no statistical difference amoung 3 groups. 3. In group I, there were no procedural accidents, such as ledging, perforation, or instrument fracture. In group 2, two cases of ledge and one case of instrument fracture were produced Goup 3, each one case of ledge, perforation and instrument fracture were occurred. Whthin the limits of above results, It seems that NiTi rotary instrumentation is not All Mighty and if we use uncarefully, it is more dangerous to produce some procedural accidents than conventional hand files. But more studies should be taken to evaluate the exact effects of NiTi rotary instrumentations.

  • PDF

Effect of glide path preparation with PathFile and ProGlider on the cyclic fatigue resistance of WaveOne nickel-titanium files

  • Uslu, Gulsah;Inan, Ugur
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.2
    • /
    • pp.22.1-22.8
    • /
    • 2019
  • Objectives: The aim of this study was to investigate the effect of glide path preparation with PathFile and ProGlider nickel-titanium (NiTi) files on the cyclic fatigue resistance of WaveOne NiTi files. Materials and Methods: Forty-four WaveOne Primary files were used and divided into four groups (n = 11). In the first group (0 WaveOne), the WaveOne Primary files served as a control group and were not used on acrylic blocks. In the 1 WaveOne Group, acrylic blocks were prepared using only WaveOne Primary files, and in the PF+WaveOne group and PG+WaveOne groups, acrylic blocks were first prepared with PathFile or ProGlider NiTi files, respectively, followed by the use of WaveOne Primary files. All the WaveOne Primary files were then subjected to cyclic fatigue testing. The number of cycles to failure was calculated and the data were statistically analyzed using one-way analysis of variance (ANOVA) and the Tukey honest significant difference multiple-comparison test at a 5% significance level. Results: The highest number of cycles to failure was found in the control group, and the lowest numbers were found in the 1 WaveOne group and the PF+WaveOne group. Significant differences were found among the 1 WaveOne, PF+WaveOne, and control groups (p < 0.05). No statistically significant differences were found between the PG+WaveOne group and the other three groups (p > 0.05). Conclusion: Glide path preparation with NiTi rotary files did not affect the cyclic fatigue resistance of WaveOne Primary files used on acrylic blocks.

THE EFFECT OF NITI ROTARY INSTRUMENTATION ON THE CONFIGURATION OF APICAL ROOT CANAL (NiTi Rotary Instruments에 의한 근관형성이 치근단부 근관형태에 미치는 영향)

  • Oh, Hyun-Jung;Hong, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.244-253
    • /
    • 1997
  • During preparation of narrow curved canals, procedural accidents such as, ledge, zipping, and transportation are frequently encountered and may lead to failure of endodontic therapy. To reduce these procedural errors and efficiently manage curved canals, various modifications in instrumentation technique and the design and flexibility of instruments have been advocated. This study compared the maintenance of the original canal curvature, cross sectional canal shape, and preparation time during instrumentation with stainless steel hand (K-Flexo) file, and nickel-titanium rotary files (Profile and Lightspeed). Thirty resin blocks with simulated curved canals of 20~25 degrees were used and divided into three groups of 10 each. In group 1, canals were instrumented using a quarter turn/pull technique with K-Flexofiles. Group 2 canals were prepared with rotary NiTi Profiles. Group 3 was prepared with rotary NiTi Lightspeed instrument. Before and after instrumentation, all canals were scanned using stereo microcope, FlexCam camera, and Photoshop 3.0 computer program. The results were as follows : 1. All groups showed some loss of canal curvature after instrumentation. Average loss of canal curvature was 8.6 degrees for K-Flexofile, 7.7 degrees for Profile, and 5.8 degrees for Lightspeed. Lightspeed exhibited significantly less curvature loss than K-Flexofile (p<0.05). 2. At the apical 1-mm level, Profile produced significantly rounder canals than Lightspeed (p<0.05). At the 3-mm level, Profile and Lightspeed exhibited significantly rounder canals than K-Flexofile (p<0.05). 3. Preparation with Lightspeed was significantly faster than Profile and K-Flexofile, and Profile was faster than K-Flexofile (p<0.05). 4. There was no significant difference in incidence of zipping between the hand K-Flexofile and rotary NiTi (Profile and Lightspeed) instruments. Most of apical canals were slightly widened near the apical foramen. As a results of this study, rotary NiTi instruments are superior to the K-Flexofile in regard to the maintenance of original canal curvature, cross-sectional shape and preparation time. But more investigations and studies should be needed to evaluate the ideal canal instrumentation.

  • PDF