1 |
Sotokawa T. An analysis of clinical breakage of root canal instruments. J Endod 14:75-82, 1988
DOI
ScienceOn
|
2 |
Zinelis S, Margelos J. Assessment of fracture mechanism of endodontic files. In: Lambrianidis T ed. Risk Management in Root Canal Treatment, 1st edn. Thessaloniki, Greece: University Studio Press, pp. 239-243, 2001
|
3 |
Sarkar NK, Redmond W, Schwaninger B, Goldberg AJ. The chloride corrosion of four orthodontic wires. J Oral Rehabil 10:121-128, 1983
DOI
|
4 |
Haikel Y, Serfaty R, Wilson P, Speisser JM, Allemann C. Cutting efficiency of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment. J Endod 24:736-739, 1998
DOI
ScienceOn
|
5 |
Haikel Y, Serfaty R, Wilson P, Speisser JM, Allemann C. Mechanical properties of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment. J Endod 24:731-735, 1998
DOI
ScienceOn
|
6 |
Wever DJ, Veldhuizen AG, de Vries J, Busscher HJ, Uges DR, van Horn JR. Electrochemical and surface characterization of a nickel-titanium alloy. Biomaterials 19:761-769, 1998
DOI
ScienceOn
|
7 |
Stokes OW, Fiore PM, Barss JT, Koerber A, Gilbert JL, Lautenschlager EP. Corrosion in stainless-steel and nickel-titanium files. J Endod 25:17-20, 1999
DOI
PUBMED
|
8 |
Oshida Y, Sachdeva RCI, Miyazaki S. Microanalytical characterization and surface modification of NiTi orthodontic arch wires. Biomed Mater Eng 2:51-69, 1992
PUBMED
|
9 |
Angelini E, Zucchi F, Caputo A. Degradation processes on metallic surfaces. In: Barbucci R, ed. Integrated Biomaterial Science. Dordrecht: Kluwer Academic - Plenum Publishers, pp. 308-323, 2002
|
10 |
Montero-Ocampo C, Lopez H, Salinas Rodriguez A. Effect of compressive straining on corrosion resistance of a shape memory Ni-Ti alloy in Ringer's solution. J Biomed Mater Res 32:583-591, 1996
DOI
ScienceOn
|
11 |
Walia HM, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of nitinol root canal files. J Endod 14:346-351, 1988
DOI
ScienceOn
|
12 |
Luebke NH, Brantley WA, Alapati SB, Mitchell JC, Lausten LL, Daehn GS. Bending fatigue study of nickel- titanium Gates Glidden drills. J Endod 31:523-525, 2005
DOI
ScienceOn
|
13 |
Iijima M, Endo K, Yuasa T, Ohno H, Hayashi K, Kakizaki M, Mizoguchi I. Galvanic corrosion behavior of orthodontic archwire alloys coupled to bracket alloys. Angle Orthod 76:705-711, 2006
PUBMED
|
14 |
Schilder H. Filling root canals in three dimensions. Dent Clin North Am 11:723-744, 1967
|
15 |
Thierry B, Tabrizian M, Trepanier C, Savadogo O, Yahia L. Effect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy. J Biomed Mater Res 51:685-693, 2000
DOI
ScienceOn
|
16 |
Burstein GT, Liu C, Souto RM. The effect of temperature on the nucleation of corrosion pits on titanium in Ringer's physiological solution. Biomaterials 26:245-256, 2005
DOI
ScienceOn
|
17 |
Schilder H. Cleaning and shaping the root canal. Dent Clin North Am 18:269-296, 1974
PUBMED
|
18 |
Peters OA, Roehlike JO, Baumann MA. Effect of immersion in sodium hypochlorite on torque and fatigue resistance of nickel-titanium instruments. J Endod 33:589-593, 2007
DOI
ScienceOn
|
19 |
Martin B, Zelada G, Varela P, Bahillo JG, Maga′n F, Ahn S, Rodriguez C. Factors influencing the fracture of nickel-titanium rotary instruments. Int Endod J 36:262-266, 2003
DOI
ScienceOn
|
20 |
O'Hoy PYZ, Messer HH, Palamara JE. The effect of cleaning procedures on fracture properties and corrosion of NiTi files. Int Endod J 36:724-732, 2003
DOI
ScienceOn
|
21 |
Lee JK, Kim ES, Kang MW, Kum KY. The effect of surface defects on the cyclic fatigue fracture of HERO shaper Ni-Ti rotary files in a dynamic model: A fractographic analysis. J Kor Acad Cons Dent 32:130-136, 2007
과학기술학회마을
DOI
|
22 |
Haapasalo M, Endal U, Zandi H, Coil JM. Eradication of endodontic infection by instrumentation and irrigation solutions. Endodontic Topics 10:77-102, 2005
DOI
ScienceOn
|
23 |
Busslinger A, Sener B, Barbakow F. Effects of sodium hypochlorite on nickel-titanium lightspeed instruments. Int Endod J 31:290-294, 1998
DOI
ScienceOn
|
24 |
Darabara M, Bourithis L, Zinelis S, Papadimitriou GD. Susceptibility to localized corrosion of stainless steel and NiTi endodontic instruments in irrigating solutions. Int Endod J 37:705-710, 2004
DOI
ScienceOn
|
25 |
Endo K, Sachdeva R, Araki Y, Ohno H. Effects of titanium nitride coatings on surface and corrosion characteristics of Ni-Ti alloy. Dent Mater J 13:228-239, 1994
DOI
PUBMED
ScienceOn
|
26 |
Zehnder M. Root canal irrigants. J Endod 32:389-398, 2006
DOI
ScienceOn
|
27 |
Kuhn G, Tavernier B, Jordan L. Influence of structure on nickel-titanium endodontic instruments failure. J Endod 27:516-520, 2001
DOI
ScienceOn
|
28 |
Trepanier C, Tabrizian M, Yahia LH, Bilodeau L, Piron DL. Effect of modification of oxide layer on NiTi stent corrosion resistance. J Biomed Mater Res 43:433-440, 1998
DOI
ScienceOn
|
29 |
International ASM. ASM handbook, fatigue and fracture, vol.19. Materials Park, OH: ASM International; 1996
|
30 |
Firstov GS, Vitchev RG, Kumar H, Blanpain B, Van Humbeeck J. Surface oxidation of NiTi shape memory alloy. Biomaterials 23:4863-4871, 2002
DOI
ScienceOn
|
31 |
Huang HH. Effect of chemical composition on the corrosion behavior of Ni-Cr-Mo dental casting alloys. J Biomed Mater Res 60:458-465, 2002
DOI
ScienceOn
|
32 |
Sirtes G, Waltimo T, Schaetzle M, Zehnder M. The effects of temperature on sodium hypochlorite shortterm stability, pulp dissolution capacity, and antimicrobial efficacy. J Endod 31:669-671, 2005
DOI
ScienceOn
|
33 |
Kim H, Johnson JW. Corrosion of stainless steel, nickel- titanium, coated nickel-titanium and titanium orthodontic wires. Angle Orthod 69:39-44, 1999
PUBMED
|
34 |
Rondelli G, Vicentini B. Evaluation by electrochemical tests of the passive film stability of equiatomic Ni-Ti alloy also in presence of stress-induced martensite. J Biomed Mater Res 51:47-54, 2000
DOI
ScienceOn
|