• 제목/요약/키워드: Neutral-point voltage control

검색결과 113건 처리시간 0.031초

T-type 3-레벨 PWM 컨버터의 중성점 전류 분석 (Analysis of Neutral Point Current in T-Type Three-Level PWM Converter)

  • 이귀준
    • 전력전자학회논문지
    • /
    • 제25권1호
    • /
    • pp.68-71
    • /
    • 2020
  • As a T-type three-level PWM converter has several intrinsic advantages, it has been widely studied for many applications. However, it requires an additional voltage control loop for balancing each DC link voltage. Generally, satisfying this requirement involves the use of an offset voltage to provide a neutral point current without affecting other variables, such as the total DC link voltage and three-phase input current. In this study, the theoretical relationship between the offset voltage and the neutral point current is analyzed. The results can be beneficial for effective voltage balancing controller design. The effectiveness of the analytical modeling is verified by simulation and experimental results.

Carrier Based Common Mode Voltage Reduction Techniques in Neutral Point Clamped Inverter Based AC-DC-AC Drive System

  • Ojha, Amit;Chaturvedi, Pradyumn;Mittal, Arvind;Jain, Shailendra
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.142-152
    • /
    • 2016
  • Common mode voltage (CMV) generation is a major problem in switching power converter fed induction motor drive systems. CMV is the zero sequence voltage generated due to the switching action of power converters. Even a small magnitude of CMV with a high rate of change may circulate large bearing currents which may damage a machine's bearings and shorten its life. There are several methods of controlling CMV. This paper presents 3-level sinusoidal pulse width modulation based techniques to control the magnitude and rate of change of CMV in multilevel AC-DC-AC drive systems. Simulation and experimental investigations have been presented to validate the performance of proposed technique to control CMV in 3-level neutral point clamped inverter based AC-DC-AC system.

Neutral Point Balancing Algorithm for Multi-level Converter under Unbalanced Operating Conditions

  • Jung, Kyungsub;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.177-178
    • /
    • 2015
  • This paper presents a neutral point deviation compensating control algorithm applied to a 3-level NPC converter. The neutral point deviation is analyzed with a focus on the current flowing out of or into the neutral point of the dc link. Based on the zero sequence components of the reference voltages, this paper analyzes the neutral point deviation and balancing control for 3-level NPC converter. An analytical method is proposed to calculate the injected zero sequence voltage for NP balancing based on average neutral current. This paper also proposes a control scheme compensating for the neutral point deviation under generalized unbalanced grid operating conditions. The positive and negative sequence components of the pole voltages and ac input currents are employed to accurately explain the behavior of 3-level NPC converter. Simulation and experimental results for a test set up of 30kW are shown to verify the validity of the proposed algorithm.

  • PDF

다양한 불평형 계통 상황에서 계통 연계형 3-레벨 NPC 컨버터의 중성점 전류 변동에 대한 해석 및 제어 (Analysis and Control of Neutral Point Current Deviation in Grid Tied 3-Level NPC Converter under Various Grid Unbalanced Conditions)

  • 최재훈;서용석
    • 전력전자학회논문지
    • /
    • 제25권5호
    • /
    • pp.385-393
    • /
    • 2020
  • This study introduces an analysis and control method for the variation of neutral point current in a grid-tied three-level neutral point clamped (NPC) converter under various grid imbalance operating conditions. Various fault cases with unbalanced amplitude and phase are systematically categorized and described using a unified metric called the imbalance factor. The fundamental component of neutral point current is generated under grid imbalance cases. The pattern and behavior of this fundamental component of neutral point current highly depend on the imbalance factor regardless of the particular type of grid fault cases. The control scheme for regulating the negative sequential component of AC input current effectively reduces the size of the fundamental component of neutral point current under a wide range of grid imbalance cases. The control scheme will enable a grid-tied three-level NPC converter to operate reliably and stably under various types of grid faults.

Fast Voltage-Balancing Scheme for a Carrier-Based Modulation in Three-Phase and Single-Phase NPC Three-Level Inverters

  • Chen, Xi;Huang, Shenghua;Jiang, Dong;Li, Bingzhang
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1986-1995
    • /
    • 2018
  • In this paper, a novel neutral-point voltage balancing scheme for NPC three-level inverters using carrier-based sinusoidal pulse width modulation (SPWM) method is developed. The new modulation approach, based on the obtained expressions of zero sequence voltage in all six sectors, can significantly suppress the low-frequency voltage oscillation in the neutral point at high modulation index and achieve a fast voltage-balancing dynamic performance. The implementation of the proposed method is very simple. Another attractive feature is that the scheme can stably control any voltage difference between the two dc-link capacitors within a certain range without using any extra hardware. Furthermore, the presented scheme is also applicable to the single-phase NPC three-level inverter. It can maintain the neutral-point voltage balance at full modulation index and improve the voltage-balancing dynamic performance of the single-phase NPC three-level inverter. The performance of the proposed strategy and its benefits over other previous techniques are verified experimentally.

Three-level Inverter Direct Torque Control of Induction Motor Based on Virtual Vectors

  • Tan Zhuohui;Li Yongdong;Hu Hu;Li Min;Chen Jie
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.369-373
    • /
    • 2001
  • Multilevel inverter has attracted great interest in high-voltage high-power field because of its less distorted output. In this paper, a direct torque control (DTC) technique based on a three-level neutral-point-clamped (NPC) inverter is presented. In order to solve the intrinsic neutral-point voltage-balancing problem and to obtain a high performance DTC, a special vector selection method is introduced and the concept of virtual vector is developed. By using the proposed PWM strategy, a MRAS speed sensor-less DTC drive can be achieved without sensing the neutral-point voltage, The strategy can be verified by simulation and experimental results.

  • PDF

NPC 3-레벨 PWM 인버터에서 고장 발생에 따른 고장 진단과 중성점 전압 제어 (Fault Diagnosis and Neutral-Point Voltage Control according to Faults for a Three-level Neutral-Point-Clamped PWM Inverter)

  • 손호인;김태진;강대욱;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.11-16
    • /
    • 2003
  • The 3-level converter/inverter system is very efficient in the ac motor drives of high voltage and high power application. This paper proposed a simple method to diagnose faults using change of current vector pattern in space vector diagram when the faults occurrence in the 3-level inverter and a control method that can protect system from unbalance of the neutral point voltage according to faults. The validity of the proposed method is demonstrated by the simulation results.

  • PDF

IPMSM Design for Sensorless Control Considering Magnetic Neutral Point Shift According to Magnetic Saturation

  • Choi, JaeWan;Seol, Hyun-Soo;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.752-760
    • /
    • 2018
  • In this paper, interior permanent magnet synchronous motor (IPMSM) design for sensorless drive, considering magnetic neutral point shift according to magnetic saturation, has been proposed. Sensorless control was divided into a method based on inductance and a method based on back induced voltage. Because induced voltage is very small at zero or low speed, error in rotor initial position estimation may occur. Using the ratio of saliency addresses this problem. When using high-frequency injections at low speed, the rotor's initial position is estimated at the smallest portion of the inductance. IPMSM has the minimum inductance at the d-axis. However, if magnetic saturation leads to magnetic neutral point variation, following the load current change, there is a change in the minimum point of inductance. In this case, it can lead to failure of initial rotor position estimation. As a result, it is essential that the blocking design has an inductance minimum point shift. As such, in this study, an IPMSM design method, by blocking magnetic neutral point change, has been proposed. After determining the inductance profile based on the finite element analysis (FEA), the results of proposed method were verified.

Simplified SVPWM that Integrates Overmodulation and Neutral Point Potential Control

  • Zhu, Rong-Wu;Wu, Xiao-Jie
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.926-936
    • /
    • 2014
  • A simplified and effective space vector pulse-width modulation (SVPWM) algorithm with two and three levels for three-phase voltage-source converters is proposed in this study. The proposed SVPWM algorithm only uses several linear calculations on three-phase modulated voltages without any complicated trigonometric calculations adopted by conventional SVPWM. This simplified SVPWM also avoids choosing the vector sector required by conventional SVPWM. A two-level overmodulation scheme is integrated into the proposed two-level SVPMW to generate the output voltage that increases from a linear region to a six-step state with a smoothly linear transition characteristic and a simple overmodulation process without a lookup table and complicated nonlinear functions. The three-level SVPWM with a proportional-integral controller effectively balances the neutral point potential of the neutral point clamped converter. Results from the simulation in MATLAB/Simulink and the experiment based on a digital signal processor are provided to clearly demonstrate the validity and effectiveness of the proposed strategies.

3-레벨 인버터 공간벡터 변조시의 중성점 전위 변동 보상법 (Compensating for the Neutral-Point Potential Variation in Three-Level Space-Vector PWM Method)

  • 서재형;김광섭;방상석;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.475-478
    • /
    • 2001
  • In performing the three-level SVPWM, it is nearly impossible to control the neutral-point potential exactly to the half of the dc-link voltage at all times. Therefore the inverter would produce an erroneous output voltage by this voltage unbalance. So the voltage unbalance has to be compensated in doing PWM, when the voltage unbalance occurs whether it is small or large, to make the inverter output voltage follow the reference voltage exactly the same. In this paper, a new compensating method for the neutral-point potential variation in a three-level inverter space vector PWM (SVPWM) is presented. By using the proposed method, the output voltage of the inverter can be made same as the reference voltage and thus the current and torque ripple of the inverter driven motor can be greatly improved even if the voltage unbalance is quite large. The proposed method is verified experimentally with a 3-level IGBT inverter.

  • PDF