Analysis of Average Neutral Point Current in 3-level NPC Converter under Generalized Unbalanced AC Input Condition

  • Jung, Kyungsub;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.151-152
    • /
    • 2016
  • This paper presents a neutral point deviation compensating control algorithm applied to a 3-level NPC converter under generalized unbalanced ac input conditions. The neutral point deviation is analyzed with a focus on the current flowing out of or into the neutral point of the dc-link in 3-level NPC converter. The model of neutral point deviation and neutral current are also constructed. The positive and negative sequence components of the pole voltages and ac input currents are employed to accurately explain the behavior of 3-level NPC converter and its impact on neutral point deviation. This paper includes the harmonic characteristic of neutral point current under various imbalance AC operating conditions.

  • PDF

직접 보상전압 추출기법을 이용하여 고조파전류와 무효전력을 보상하는 3상 4선식 직렬 형 능동전력필터의 제어법 (Three-phase Four-wire Series Active Power Filter Control Strategy for The Compensation of Harmonics and Reactive Power Based-on Direct Compensating Voltage Extraction Method)

  • 김진선;김영석
    • 전력전자학회논문지
    • /
    • 제9권3호
    • /
    • pp.213-221
    • /
    • 2004
  • 최근에, 평활용 직류 커패시터가 설치된 다이오드 정류기가 가전제품 및 교류 운전 장치와 같은 전자 장치에 점점 많이 사용되고 있고, 이러한 부하에 의해서 발생하는 고조파 문제가 점차 중요한 문제로 부각되고 있다. 또한, 3상 4선식 전력 시스템은 상업용 빌딩이나 제조 플랜트 등에 전력을 공급하는 방법으로 많이 사용되고 있는데 이러한 시스템에서는 중성선에 과도한 전류가 흐르게 되고, 중성선 전류는 기본적으로 3고조파 성분으로 중성선 도체 사이즈 선정의 실패나 중성점의 전위를 상승시키거나 변압기의 과열 현상 등을 유발할 수 있다. 이러한 관점에서 본 논문에서는 직접 보상전압 추출기법으로 동작하는 직렬 형 능동 필터를 제안하며, 성능함수 알고리즘의 장점은 게인을 곱하지 않고 보상 전압을 직접 구함으로써, 어떠한 다른 알고리즘보다 보상 전압 계산 방법이 간단하다. 제안된 알고리즘의 타당성을 증명하기 위하여 프로토타입 능동 필터를 제작하여 실험을 수행하였다.

3상 3선/4선식 전력계통의 고조파 저감을 위한 새로운 직렬형 능동 필터 시스템 (A Novel Series Active Power Filter for Harmonic Reduction of 3-Phase 3-Wire/4-Wire System)

  • 김명현;임승원;한윤석;김영석;원충연;최세완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.349-351
    • /
    • 1999
  • This paper presents a new control algorithm for series active power filters that are applied to 3-phase 3-wire and 3-phase 4-wire systems with capacitive loads. It is difficult to reduce harmonic currents in neutral lines of the 3-phase 4-wire systems using conventional series active power filter control methods. 3-phase 4-wire series active power filter systems using the proposed method in this study lower neutral line harmonics. Simulation was carried out to verify the algorithm.

  • PDF

FPGA Implementation of Diode Clamped Multilevel Inverter for Speed Control of Induction Motor

  • Kuppuswamy, C.L.;Raghavendiran, T.A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.362-371
    • /
    • 2018
  • This work proposes FPGA implementation of Carrier Disposition PWM for closed loop seven level diode clamped multilevel inverter in speed control of induction motor. VLSI architecture for carrier Disposition have been introduced through which PWM signals are fed to the neutral point seven level diode clamped multilevel using which the speed of the induction motor is controlled. This proposed VLSI architecture makes the power circuit to work better with reduced stresses across the switches and a very low voltage and current total harmonic distortion (THD). The output voltages, currents, torque & speed characteristics for seven level neutral point diode clamped multilevel inverter for AC drive was studied. It has observed the proposed scheme introduces less distortion and harmonics. The results were validated using real time results.

3상 4선식 배전계통에서 중성선 전류 제거를 위한 새로운 저가형 능동전력필터 (A New Low-Cost Active Power Filter to Suppress Neutral Current Harmonics in Three-Phase Four-Wire System)

  • 장민수;최세완;김기영
    • 전력전자학회논문지
    • /
    • 제7권4호
    • /
    • pp.359-365
    • /
    • 2002
  • 최근 상업용 빌딩, 주거용 빌딩 및 공장등의 저전압 3상 4선식 배전계통에서 PC, UPS, 정류기기, 조명장치 및 사무용기기등 비선형 부하의 사용이 증가하고 있으며, 이로 인한 과도한 중성선 전류는 중성선의 고장, 변압기의 과열 및 중성선과 접지사이의 전압강하등 심각한 문제를 야기시키고 있다. 본 논문에서는 3상 4선식 배전계통에서 중성선 전류 제거를 위한 새로운 저감된 용량의 능동전력필터를 제안한다. 제안한 방식은 제어가 간단하고 불평형에 기인하는 기본파 전류만이 인버터 스위치로 흐를 수 있기 때문에 인버터의 VA 정격이 작아진다. 제안한 시스템은 실험에 의하여 그 타당성을 입증한다.

선형 및 비선형 부하 사용시 전류 및 부하불평형률에 대한 연구 (A Study on the Current & Load Unbalance Factor in using Linear & Nonlinear Load)

  • 김종겸;김지명
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1291-1296
    • /
    • 2017
  • Single-phase and three-phase load can be used together in 3-phase 4-wire system. Single-phase and three-phase loads can be classified as linear loads without harmonics and nonlinear with harmonics. Single-phase linear loads are linear loads such as lamps and heat, and single-phase nonlinear loads are power converters such as rectifiers. It is recommended that the distribution of loads in the 3-phase, 4-wire distribution lines be evenly distributed within a certain range. However, harmonic currents generated in a nonlinear load flow on the neutral line and affect the phase current magnitude. The difference in the magnitude of the individual phase current due to the influence of the harmonic current present in the neutral line can produce a difference in current and load unbalance. In this study, current unbalance ratio and load unbalance ratio which can occur when a combination of linear and nonlinear loads are applied to 3-phase 4-wire distribution line are calculated.

A Novel Control Strategy of Three-phase, Four-wire UPQC for Power Quality Improvement

  • Pal, Yash;Swarup, A.;Singh, Bhim
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 2012
  • The current paper presents a novel control strategy of a three-phase, four-wire Unified Power Quality (UPQC) to improve power quality. The UPQC is realized by the integration of series and shunt active power filters (APF) sharing a common dc bus capacitor. The realization of shunt APF is carried out using a three-phase, four-leg Voltage Source Inverter (VSI), and the series APF is realized using a three-phase, three-leg VSI. To extract the fundamental source voltages as reference signals for series APF, a zero-crossing detector and sample-and-hold circuits are used. For the control of shunt APF, a simple scheme based on the real component of fundamental load current (I $Cos{\Phi}$) with reduced numbers of current sensors is applied. The performance of the applied control algorithm is evaluated in terms of power-factor correction, source neutral current mitigation, load balancing, and mitigation of voltage and current harmonics in a three-phase, four-wire distribution system for different combinations of linear and non-linear loads. The reference signals and sensed signals are used in a hysteresis controller to generate switching signals for shunt and series APFs. In this proposed UPQC control scheme, the current/voltage control is applied to the fundamental supply currents/voltages instead of fast-changing APF currents/voltages, thus reducing the computational delay and the required sensors. MATLAB/Simulink-based simulations that support the functionality of the UPQC are obtained.

지역필터를 이용한 수변전실 접지저항의 새로운 측정방법 (A New Measurement Method of the Ground Resistance Using a Low-pass Filter in Energized Substations)

  • 이복희;엄주홍;이승칠;김성원;안창환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권8호
    • /
    • pp.387-393
    • /
    • 2001
  • This paper describes an advanced measuring method and precise evaluation of the ground resistance for the grounding system of energized substations and power equipments. A grounding system of substations consists of all interconnected grounding connections of grounded conductors, neutral ground wires, underground conductors of distribution lines, cable shields, grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding system of high voltage energized substations because of harmonic components caused by switched power supplies or overloads. The conventional fall-of-potential method may be subject to big error if stray ground currents and potentials are present. In this work, to improve the precision in measurements of the ground resistance by eliminating the effects of harmonic components and stray currents and potentials, the investigations of the ground resistance measurement by using a low pass filter in a model energized grounding system were conducted. The accuracy of ground resistance mesurements was evaluated as a function of the ratio of the test signal to noise (S/N). The errors due to the proposed ground resistance measurement method were decreased with increasing S/N and were less than 5[%] as S/N is 10. The proposed ground resistance measurement method appears to be considerably more accurate than the conventional fall-of -potential method. It is allows cancellation of the parasitic resistance of energized grounding systems, to employ the measurement method that allows cancellation of the parasitic effects due to other circulating ground currents and ground potential rises in practical situations.

  • PDF

Control Strategy for Selective Compensation of Power Quality Problems through Three-Phase Four-Wire UPQC

  • Pal, Yash;Swarup, A.;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.576-582
    • /
    • 2011
  • This paper presents a novel control strategy for selective compensation of power quality (PQ) problems, depending upon the limited rating of voltage source inverters (VSIs), through a unified power quality conditioner (UPQC) in a three-phase four-wire distribution system. The UPQC is realized by the integration of series and shunt active power filters (APFs) sharing a common dc bus capacitor. The shunt APF is realized using a three-phase, four-leg voltage source inverter (VSI), while a three-leg VSI is employed for the series APF of the three-phase four-wire UPQC. The proposed control scheme for the shunt APF, decomposes the load current into harmonic components generated by consumer and distorted utility. In addition to this, the positive and negative sequence fundamental frequency active components, the reactive components and harmonic components of load currents are decomposed in synchronous reference frame (SRF). The control scheme of the shunt APF performs with priority based schemes, which respects the limited rating of the VSI. For voltage harmonic mitigation, a control scheme based on SRF theory is employed for the series APF of the UPQC. The performance of the proposed control scheme of the UPQC is validated through simulations using MATLAB software with its Simulink and Power System Block set toolboxes.

Optimized Low-Switching-Loss PWM and Neutral-Point Balance Control Strategy of Three-Level NPC Inverters

  • Xu, Shi-Zhou;Wang, Chun-Jie;Han, Tian-Cheng;Li, Xue-Ping;Zhu, Xiang-Yu
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.702-713
    • /
    • 2018
  • Power loss reduction and total harmonic distortion(THD) minimization are two important goals of improving three-level inverters. In this paper, an optimized pulse width modulation (PWM) strategy that can reduce switching losses and balance the neutral point with an optional THD of three-level neutral-point-clamped inverters is proposed. An analysis of the two-level discontinuous PWM (DPWM) strategy indicates that the optimal goal of the proposed PWM strategy is to reduce switching losses to a minimum without increasing the THD compared to that of traditional SVPWMs. Thus, the analysis of the two-level DPWM strategy is introduced. Through the rational allocation of the zero vector, only two-phase switching devices are active in each sector, and their switching losses can be reduced by one-third compared with those of traditional PWM strategies. A detailed analysis of the impact of small vectors, which correspond to different zero vectors, on the neutral-point potential is conducted, and a hysteresis control method is proposed to balance the neutral point. This method is simple, does not judge the direction of midpoint currents, and can adjust the switching times of devices and the fluctuation of the neutral-point potential by changing the hysteresis loop width. Simulation and experimental results prove the effectiveness and feasibility of the proposed strategy.