• Title/Summary/Keyword: Negative Sequence

Search Result 553, Processing Time 0.032 seconds

Improved Grid Voltage Control Strategy for Wind Farms with DFIGs Connected to Distribution Networks

  • Zhang, Xueguang;Pan, Weiming;Liu, Yicheng;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.495-502
    • /
    • 2012
  • This paper presents an improved grid voltage control strategy for wind farms with doubly-fed induction generators (DFIGs) connected to distribution networks based on an analysis of the operation limits of DFIG systems. A modified reactive power limit calculation method in different operation states is proposed and a reactive power control strategy during grid voltage dips/rises is further discussed. A control strategy for compensating unbalanced grid voltage, based on DFIG systems, by injecting negative sequence current into the grid through the grid side converter (GSC) is proposed. In addition, the negative current limit of the GSC is discussed. The distribution principle of the negative sequence current among the different DFIG systems in a wind farm is also introduced. The validity of the proposed voltage control strategy is demonstrated by Matlab/Simulink simulations. It is shown that the stability of a wind farm and the power grid can be improved with the proposed strategy.

Pulse-Sequence Analysis of Discharges in Air, Liquid and Solid Insulating Materials

  • Suwayno, Suwayno;Mizutani, Teruyoshi
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.528-533
    • /
    • 2006
  • Electrical discharges may occur in gas, liquid as well as solid insulating materials. This paper describes the investigation results on the discharges in air, silicone oil and low density polyethylene (LDPE) using needle plane electrode system under AC voltage of 50 Hz. The experimental results showed that for discharge in air (corona), discharge pulses were concentrated around the peak of applied voltage at negative half cycle. For silicone oil positive as well as negative discharges were observed which concentrated around the peak of applied voltage. The positive pulse number was smaller but the magnitude was higher than that of negative discharge. Discharges in void took place at wider range of phase of applied voltage. The unbalance in pulse number and magnitude similar to that of oil discharges were observed. For electrical treeing in LDPE, the discharges were spread before the zero cross of the applied voltage up to the peak at both positive and negative half cycles. The discharge pulse sequence analysis indicated that the PD occurrence in air, oil and void were strongly affected by the magnitude of applied voltage. However, for electrical treeing it was observed that the discharge occurrence was strongly affected by the time derivative of the applied voltage (dv/dt).

FUNDAMENTAL RESEARCH OF A NOVEL 3/1 PHASE CONVERTER FOR ELECTRIFIED RAILROAD

  • Farshad, Siamak;Rongtai, Hao
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.955-960
    • /
    • 1998
  • Electrified railroads inject large amount of harmonics, negative sequence and reactive currents to electric supply systems. This paper introduces application of active filter as a 3/1 phase converter for electrified railroad. In this system active filter compensate harmonics, negative sequence and reactive currents and electric railroad and active filter together act as a balance three-phase load with power factor 1

  • PDF

Loop Selective Direction Measurement for Distance Protection

  • Steynberg, Gustav;Koch, Geyhard
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.423-426
    • /
    • 2006
  • Distance relays achieve selective tripping by measurement of all short circuit fault conditions inside set reaches. The direction of the fault, forward or reverse is commonly determined with a dedicated measurement to ensure selectivity under all conditions. For the direction decision (measurement) a number of alternatives are available. This paper describes a loop selective direction measurement and illustrates by means of a typical fault why this is superior to a non loop selective direction measurement such as that based on negative sequence quantities.

THE COMPLETE MOMENT CONVERGENCE FOR ARRAY OF ROWWISE ENOD RANDOM VARIABLES

  • Ryu, Dae-Hee
    • Honam Mathematical Journal
    • /
    • v.33 no.3
    • /
    • pp.393-405
    • /
    • 2011
  • In this paper we obtain the complete moment convergence for an array of rowwise extended negative orthant dependent random variables. By using the result we can prove the complete moment convergence for some positively orthant dependent sequence satisfying the extended negative orthant dependence.

Design and Evaluation of a Protection Relay for a Wind Generator Based on the Positive- and Negative-Sequence Fault Components

  • Zheng, Taiying;Cha, Seung-Tae;Kim, Yeon-Hee;Crossley, Peter A.;Lee, Sang Ho;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1029-1039
    • /
    • 2013
  • To avoid undesirable disconnection of healthy wind generators (WGs) or a wind power plant, a WG protection relay should discriminate among faults, so that it can operate instantaneously for WG, connected feeder or connection bus faults, it can operate after a delay for inter-tie or grid faults, and it can avoid operating for parallel WG or adjacent feeder faults. A WG protection relay based on the positive- and negative-sequence fault components is proposed in the paper. At stage 1, the proposed relay uses the magnitude of the positive-sequence component in the fault current to distinguish faults requiring non-operation response from those requiring instantaneous or delayed operation responses. At stage 2, the fault type is first determined using the relationships between the positive- and negative-sequence fault components. Then, the relay differentiates between instantaneous operation and delayed operation based on the magnitude of the positive-sequence fault component. Various fault scenarios involving changes in position and type of fault and faulted phases are used to verify the performance of the relay. This paper concludes by implementing the relay on a hardware platform based on a digital signal processor. Results indicate that the relay can successfully distinguish the need for instantaneous, delayed, or non-operation.

Implementation of Dual Current Controller and Realtime Power Limiting Algorithm in Grid-connected Inverter during Unbalanced Voltage Conditions (전원 전압 불평형시 계통연계형 인버터의 유효전력 리플 억제를 위한 듀얼 전류제어기 구현과 출력 전력의 실시간 제한 알고리즘)

  • Song Seung-Ho;Kim Jeong-Jae
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.1
    • /
    • pp.54-60
    • /
    • 2006
  • A power limiting algorithm is proposed for stable operation of grid-connected inverter in case of grid voltage unbalance considering the operation limit of inverter. During the voltage unbalance the control performance of Inverter. is degraded and the output power contains 120Hz ripple due to the negative sequence of voltage. In this paper, conventional dual sequence current controller is implemented to solve these problems using separated control of positive and negative sequence. Especially the maximum power limit which guarantees the maximum rated current of the inverter is automatically calculated as the instant grid voltage changes. As soon as the voltage recovers the proposed algorithm can return to the normal power control mode accomplishing low voltage ride through. Proposed algorithm is verifed using PSCAD/EMTDC simulations and tested experimentally at 4.4kW wind turbine simulator set-up.

Grid-connected Inverter Control Algorithm for Torque Ripple Compensation in Doubly-Fed Induction-type Wind Power Generation System (전원 전압 불평형시 이중여자 유도형 풍력발전 시스템의 토크 리플 저감을 위한 계통연계 인버터 제어 알고리즘)

  • Jeong, Byoung-Chang;Song, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.317-319
    • /
    • 2005
  • In this paper, control algorithm for torque ripple compensation in DFIG wind power generation system is proposed. A simple PI controller is designed for the negative sequence voltage cancellation using negative sequence currents in the grid-side converter. As a result, the stator voltage contains only the positive sequence components and the torque pulsation of the generator is effectively compensated. Propose algorithm is confirmed with PSCAD simulation model.

  • PDF

The Reasonable Concrete-Placing Methods and Sequences of Composite Steel Bridge (강합성형 교량의 합리적인 타설방법과 순서에 관한 연구)

  • Jo, Byung-Wan;Seo, Sug-Gu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.2
    • /
    • pp.205-212
    • /
    • 1999
  • Recently, unexpected cracks in the concrete deck slab of composite steel bridges have been widely reported at an early age of concrete placing due to the concrete placing sequence and methods. Accordingly, the analytical research was carried out to verify the negative moment at an internal supports due to the several concrete pouring sequence and to determine the reasonable concrete placing method on the deck slab of composite steel bridge. The results show that the conventional concrete-placing method, which pours concrete first on the positive moment regions and then negative regions, leads to the minimum moment at an internal supports. However, the conventional method produces two impractical construction joints on every spans and makes field engineer to pour concrete continuously. In conclusion, this concrete-placing method was verified to be reasonable only when the construction joint was placed at the $\frac{5}{8}l{\sim}\frac{6}{8}l$ location of the middle span.

  • PDF

Characterization of Trimethoprim-Sulfamethoxazole Resistance Genes and Their Relatedness to Class 1 Integron and Insertion Sequence Common Region in Gram-Negative Bacilli

  • Shin, Hae Won;Lim, Jinsook;Kim, Semi;Kim, Jimyung;Kwon, Gye Cheol;Koo, Sun Hoe
    • Journal of Microbiology and Biotechnology
    • /
    • v.25 no.1
    • /
    • pp.137-142
    • /
    • 2015
  • Trimethoprim-sulfamethoxazole (TMP-SMX) has been used for the treatment of urinary tract infections, but increasing resistance to TMP-SMX has been reported. In this study, we analyzed TMP-SMX resistance genes and their relatedness with integrons and insertion sequence common regions (ISCRs) in uropathogenic gram-negative bacilli. Consecutive nonduplicate TMP-SMX nonsusceptible clinical isolates of E. coli, K. pneumoniae, Acinetobacter spp., and P. aeruginosa were collected from urine. The minimal inhibitory concentration was determined by Etest. TMP-SMX resistance genes (sul and dfr), integrons, and ISCRs were analyzed by PCR and sequencing. A total of 45 E. coli (37.8%), 15 K. pneumoniae (18.5%), 12 Acinetobacter spp. (70.6%), and 9 Pseudomonas aeruginosa (30.0%) isolates were found to be resistant to TMP-SMX. Their MICs were all over 640. In E. coli and K. pneumoniae, sul1 and dfr genes were highly prevalent in relation with integron1. The sul3 gene was detected in E. coli. However, in P. aeruginosa and Acinetobacter spp., only sul1 was prevalent in relation with class 1 integron; however, dfr was not detected and sul2 was less prevalent than in Enterobacteriaceae. ISCR1 and/or ISCR2 were detected in E. coli, K. pneumoniae, and Acinetobacter spp. but the relatedness with TMP-SMX resistance genes was not prominent. ISCR14 was detected in six isolates of E. coli. In conclusion, resistance mechanisms for TMP-SMX were different between Enterobacteriaceae and glucose non-fermenting gram-negative bacilli. Class 1 integron was widely disseminated in uropathogenic gram-negative baciili, so the adoption of prudent use of antimicrobial agents and the establishment of a surveillance system are needed.