• Title/Summary/Keyword: National Control Points

Search Result 897, Processing Time 0.031 seconds

Accuracy Improvement of KOMPSAT-3 DEM Using Previous DEMs without Ground Control Points

  • Lee, Hyoseong;Park, Byung-Wook;Ahn, Kiweon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.4
    • /
    • pp.241-248
    • /
    • 2017
  • GCPs (Ground Control Points) are needed to correct the DEM (Digital Elevation Model) produced from high-resolution satellite images and the RPC (Rational Polynomial Coefficient). It is difficult to acquire the GCPs through field surveys such as GPS surveys and to read the image coordinates corresponding to the GCPs. In addition, GCPs cannot cover the entire image of the test site, and the RPC correction results may be influenced by the arrangement and distribution of the GCPs in the image. Therefore, a new method for the RPC correction is needed. In this study, an LHD (Least-squares Height Difference) DEM matching method was applied using previous DEMs: SRTM DEM, digital map DEM, and corrected IKONOS DEM. This was carried out to correct the DEM produced from KOMPSAT-3 satellite images and the provided RPC without GCPs. The IKONOS DEM had the highest accuracy, and the height accuracy was about ${\pm}3m$ RMSE in a mountainous area and about ${\pm}2m$ RMSE in an area with only low heights.

The Effects of Abdominal Meridian Massage on Menstrual Cramps and Dysmenorrhea in Full-time Employed Women (복부 경락마사지가 직장여성의 생리통 및 월경곤란증에 미치는 영향)

  • Kim Jung-Soon;Jo Young-Ja;Hwang Sun-Kyung
    • Journal of Korean Academy of Nursing
    • /
    • v.35 no.7
    • /
    • pp.1325-1332
    • /
    • 2005
  • Purpose: This study was designed to examine the effects of abdominal meridian(Kyongrak) massage on menstrual cramps and dysmenorrhea. Method: Eighty-five women (of 110 screened) enrolled in this study and were employed full-time with more than 6.0 points(in $0\~10.0$ VAS scale) in menstrual cramps or more than 20 points on the dysmenorrhea scale(range $13\~52$). The forty-two participants in the experimental group received abdominal meridian massage for 5 minutes per day during 6 days from the fifth day before menstruation to the first day of menstruation and the forty-three participants in the control group didn't receive any treatment. Data were collected from June 1st to August 30th, 2003 and analyzed using descriptive statistics, $x^2-test$, and t-test. Result: Menstrual cramps and dysmenorrhea of the experimental group were significantly lower after abdominal meridian massage than those of the control group (p<.001). Conclusion: Abdominal meridian(Kyongrak) massage was very effective for relief of menstrual cramps and dysmenorrhea. Therefore, we suggest that abdominal Kyongrak massage can be a useful nursing intervention for women with menstrual cramps or dysmenorrhea.

Economic Design of Variable Sample Size ${\bar{X}}$ Control Chart Using a Surrogate Variable (대용변수를 이용한 가변형 부분군 크기 ${\bar{X}}$ 관리도의 경제적 설계)

  • Lee, Tae Hoon;Lee, Min Koo;Kwon, Hyuck Moo;Hong, Sung Hoon;Lee, Jooho
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.4
    • /
    • pp.943-956
    • /
    • 2017
  • Purpose: This paper proposes a VSS(Variable Sample Size) ${\bar{X}}$ control chart using surrogate variable and shows its effectiveness compared with FSS(Fixed Sample Size) ${\bar{X}}$ control chart using either performance variable or surrogate variable. Methods: The expected cost function of VSS ${\bar{X}}$ control chart is derived. The optimal designs are then found for numerical examples using a GA(genetic algorithm) and compared to those of the FSS ${\bar{X}}$ control charts. Results: Computational results show that VSS ${\bar{X}}$ control chart using surrogate variables is superior to FSS ${\bar{X}}$ control chart using either performance variable or surrogate variable from the economic view points. Conclusion: The proposed VSS ${\bar{X}}$ control chart will be useful in industry fields where a performance variable is not avaliable or too costly.

Development of a Motion Control Algorithm for the Automatic Operation System of Overhead Cranes (천장크레인의 무인운전 시스템을 위한 운동제어 알고리즘 개발)

  • Lee, Jong-Kyu;Park, Young-Jo;Lee, Sang-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.10
    • /
    • pp.3160-3172
    • /
    • 1996
  • A search algorithm for the collision free, time optimal transport path of overhead cranes has been proposed in this paper. The map for the working environment of overhead cranes was constructed in the form of three dimensional grid. The obstacle occupied region and unoccupied region of the map has been represented using the octree model. The best-first search method with a suitable estimation function was applied to select the knot points on the collision free transport path to the octree model. The optimization technique, minimizing the travel time required for transporting objects to the goal while subjected to the dynamic constraints of the crane system, was developed to find the smooth time optimal path in the form of cubic spline functions which interpolate the selected knot points. Several simulation results showed that the selected estimation function worked effectively insearching the knot points on the collision free transport path and that the resulting transport path was time optimal path while satisfying the dynamic constraints of the crane system.

Condition Monitoring of Check Valve Using Neural Network

  • Lee, Seung-Youn;Jeon, Jeong-Seob;Lyou, Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2198-2202
    • /
    • 2005
  • In this paper we have presented a condition monitoring method of check valve using neural network. The acoustic emission sensor was used to acquire the condition signals of check valve in direct vessel injection (DVI) test loop. The acquired sensor signal pass through a signal conditioning which are consisted of steps; rejection of background noise, amplification, analogue to digital conversion, extract of feature points. The extracted feature points which represent the condition of check valve was utilized input values of fault diagnosis algorithms using pre-learned neural network. The fault diagnosis algorithm proceeds fault detection, fault isolation and fault identification within limited ranges. The developed algorithm enables timely diagnosis of failure of check valve’s degradation and service aging so that maintenance and replacement could be preformed prior to loss of the safety function. The overall process has been experimented and the results are given to show its effectiveness.

  • PDF

The Experience of Open Reduction and Internal Fixation of Mandible Fracture by Acupuncture Method (Acupuncture를 이용한 하악골 골절수술경험 -증례 보고-)

  • Khil, Hong-Mo;Kwak, Ho-Sung;Ro, Shik
    • The Korean Journal of Pain
    • /
    • v.9 no.1
    • /
    • pp.195-199
    • /
    • 1996
  • Based on points of neuroendocrine physiology, stimulus developed at the acupuncture site can pass to the pituitary gland through somatosensory and activated descending inhibitory mechanism which originated in raphe magnus of midbrain. For the operation of mandible fracture, acupuncture anesthesia was performed at 6 points of both forearm and both feet by method taking point on distant segment. Acupuncture anesthesia deals with central analgesic mechanism and the theory of diffuse noxious inhibitory control.

  • PDF

Perception of Hygiene Education and Food Safety Knowledge among New Restaurant Owners -Focused in Gyeongnam Area- (일반음식점 신규영업자의 위생교육에 대한 인식 및 위생지식 조사 -경남지역을 중심으로-)

  • Yun, Ji-Yeong;Mun, Hye-Gyeong
    • Journal of the Korean Dietetic Association
    • /
    • v.13 no.3
    • /
    • pp.265-276
    • /
    • 2007
  • The Purpose of this research was to assess food safety knowledge and perceptions on hygiene education among new owners of restaurant in Gyeongnam area. In the questionnaire survey to 462 new owners of the necessity of hygiene education, more than half of them(56.3%) answered ‘Needed’ while ‘So so(29.2%)’ and ‘No need(14.1%)’ were also not a few. For the questionnaire asked what educational area was most beneficial, ‘Restaurant management and service(53%)’ was the most selected followed by ‘Food safety management and briefing on relevant food safety regulations(20.1%)’, ‘Tax management(12.8%)’ and ‘Food culture and menu development(11.7%)’. According to evaluation on new owners’ food safety knowledge, total average score was turned out to 6.83(out of total score of 15), less than 50% of average correct answers, it signified the demand for quantitative and qualitative improvement on hygiene education. To view the three areas’ evaluation score, characteristics of foodborne illness(2.56 points, out of total 5 points) and general hygiene management(2.54 points) marked more than 50% of correct answers while critical control points marked only 1.73 points, the lowest score.

  • PDF

A New Method for Identifying Higher Volterra Kernel Having the Same Time Coordinate for Nonlinear System

  • Nishiyama, Eiji;Harada, Hiroshi;Rong, Li;Kashiwagi, Hiroshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.137-140
    • /
    • 1999
  • A lot of researcher have proposed a method of kernel identifying nonlinear system by use of Wiener kernels[6-7] or Volterra kernel[5] and so on. In this research, the authors proposed a method of identifying Volterra kernels for nonlinear system by use of pseudorandom M-sequence in which a crosscorrelation function between input and output of a nonlinear system is taken[4]. we can be applied to an MISO nonlinear system or a system which depends on its input amplitude[2]. But, there exist many systems in which it is difficult to determine a Volterra kernel having the same time coordinate on the crosscorrelation function. In those cases, we have to estimate Volterra kernel by using its neighboring points[4]. In this paper, we propose a new method for not estimating but obtaining Volterra kernel having the same time coordinate using calculation between the neighboring points. Some numerical simulations show that this method is effective for obtaining higher order Volterra kernel of nonlinear control systems.

  • PDF

Development of a new digital photogrammetric technique for characterization of rock joint orientation

  • Kim Jaedong;Kim Jong-Hoon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.60-65
    • /
    • 2003
  • A new algorithm was developed to interpret joint orientations from a pair of images of the rock slope to overcome the limitation of photographing direction as in the parallel stereophotogrammetric system and to maximize the range of image measurement. This algorithm can be regarded as a modified multistage convergent photographing system. To determine camera parameters in the perspective projection equation that are the major elements in the photogrammetric technique, a new concept was developed by using three ground control points and single ground guide point. This method could be considered to be very simple when compared with other existing methods which use a number of ground control points and complicated analysis processes.

  • PDF

Stability of Solar Power System on the Control Modes of a Forced-Commutated Inverter and a Line-Commutated Inverter (Solar Power System의 인버터 토폴로지 및 제어 모드에 따른 안정도 연구)

  • Lee, Seung-Hyun;Chung, Gyo-Bum;Cho, Bo-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.534-537
    • /
    • 1997
  • Solar power systems have become popular in the modem electric energy system. In order to supply the DC power, generated by solar cells, to the electric power system, the solar power system requires DC-to-AC power conversion. A line-commutated inverter or a forced-commutated inverter can be used in the DC-to-AC power conversion. Because of the nonlinear V-I characteristics of the solar cells, multiple operating points determined by the control mode of the inverter exist in the DC V-I state plane of the solar power system. In this paper, the stability of utility-interactive solar power system with a line-commutated inverter is analyzed at various operating points, using the eigenvalue method and the state-plane analysis technique. The stability of a forced-commutated inverter case is also anaiyzed and compared to that of the line-commutated inverter case.

  • PDF