• Title/Summary/Keyword: Nanotube diameter

검색결과 155건 처리시간 0.025초

Synthesis of self-aligned carbon nanotubes on a Ni particles using Chemical Vapour Deposition

  • Park, Gyu-Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.64-64
    • /
    • 2000
  • Since its discovery in 1991, the carbon nanotube has attracted much attention all over the world; and several method have been developed to synthesize carbon nanotubes. According to theoretical calculations, carbon nanotubes have many unique properties, such as high mechanical strength, capillary properties, and remarkable electronical conductivity, all of which suggest a wide range of potential applications in the future. Here we report the synthesis in the catalytic decomposition of acetylene at ~65 $0^{\circ}C$ over Ni deposited on SiO2, For the catalyst preparation, Ni was deposited to the thickness of 100-300A using effusion cell. Different approaches using porous materials and HF or NH3 treated samples have been tried for synthesis of carbon nanotubes. It is decisive step for synthesis of carbon nanotubes to form a round Ni particles. We show that the formation of round Ni particles by heat treatment without any pre-treatment such as chemical etching and observe the similar size of Ni particles and carbon nanotubes. Carbon nanotubes were synthesized by chemial vapour deposition ushin C2H2 gas for source material on Ni coated Si substrate. Ni film gaving 20~90nm thickness was changed into Ni particles with 30~90nm diameter. Heat treatment of Ni fim is a crucial role for the growth of carbon nanotube, High-resolution transmission electron microscopy images show that they are multi-walled nanotube. Raman spectrum shows its peak at 1349cm-1(D band) is much weaker than that at 1573cm-1(G band). We believe that carbon nanotubes contains much less defects. Long carbon nanotubes with length more than several $\mu$m and the carbon particles with round shape were obtained by CVD at ~$650^{\circ}C$ on the Ni droplets. SEM micrograph nanotubes was identified by SEM. Finally, we performed TEM anaylsis on the caron nanotubes to determine whether or not these film structures are truly caron nanotubes, as opposed to carbon fiber-like structures.

  • PDF

저온에서 규칙적인 단일벽 탄소나노튜브 배열의 수소 흡착 특성 (Adsorption Characteristics of Hydrogen in Regular Single-Walled Carbon Nanotube Arrays at Low Temperature)

  • 서양곤
    • 청정기술
    • /
    • 제29권3호
    • /
    • pp.217-226
    • /
    • 2023
  • 본 연구에서는 grand canonical 몬테카를로 전산모사 방법을 이용하여 정사각형 배열을 가지는 단일벽나노튜브에서 나노튜브의 직경과 가장 가까운 튜브들 사이의 거리의 함수로써 수소의 흡착특성을 연구하였다. 그리고 동일한 직경과 간격을 가지는 삼각형 배열을 이용하여 기하학에 대한 영향도 연구하였다. 수소-탄소 그리고 수소-수소의 인력은 단거리 인력의 경우 Lennard-Jones 포텐셜을 사용하였고, 수소-수소의 경우는 정전기적 인력을 저온에서의 양자효과를 고려하기 위해 추가하였다. 194.5 K에서 큰 직경을 가지는 단일벽나노튜브의 경우 Type I과 넓은 간격을 가지는 나노튜브의 경우 흡착과 탈착과정에서 Type IV의 흡착 등온선이 관찰되었다. 200 bar에서 단일벽나노튜브의 중량 수소저장 능력은 미국 에너지부의 목표치에 도달하거나 초과하였다. 그러나 부피 수소저장 능력은 목표치의 약 70%에 해당하였다. 77 K에서는 단일층 형성과 이후 응축 단계가 따르는 두 단계의 흡착이 관찰되었다. 수소는 나노튜브의 내부 표면, 외부 표면, 관 내부의 공간 그리고 나노튜브 다발 사이의 틈새 채널의 순서로 흡착하였다. 1 bar 이하에서도 여러 가지 직경과 간격을 가지는 탄소나노튜브는 중량 그리고 부피 저장 능력이 모두 목표치를 초과하였다.

Effects of ibuprofen-loaded TiO2 nanotube dental implants in alloxan-induced diabetic rabbits

  • Kim, Young-Gyo;Kim, Wan-Tae;Jung, Bo Hyun;Yoo, Ki-Yeon;Um, Heung-Sik;Chang, Beom-Seok;Lee, Jae-Kwan;Choi, Won-Youl
    • Journal of Periodontal and Implant Science
    • /
    • 제51권5호
    • /
    • pp.352-363
    • /
    • 2021
  • Purpose: Some systemic conditions, especially diabetes mellitus (DM), adversely affect dental implant success. This study aimed to investigate the effects of ibuprofen-loaded TiO2 nanotube (ILTN) dental implants in alloxan-induced diabetic rabbits. Methods: Twenty-six New Zealand white rabbits were treated with alloxan monohydrate to induce DM. At 2 weeks following DM induction, 3 types of implants (sandblasted, large-grit, and acid-etched [SLA], ILTN, and machined) were placed into the proximal tibia in the 10 rabbits that survived following DM induction. Each type of implant was fitted randomly in 1 of the holes (round-robin method). The animals were administered alizarin (at 3 weeks) and calcein (at 6 weeks) as fluorescent bone markers, and were sacrificed at 8 weeks for radiographic and histomorphometric analyses. Results: TiO2 nanotube arrays of ~70 nm in diameter and ~17 ㎛ in thickness were obtained, and ibuprofen was loaded into the TiO2 nanotube arrays. A total of 26 rabbits were treated with alloxan monohydrate and only 10 rabbits survived. The 10 surviving rabbits showed a blood glucose level of 300 mg/dL or higher, and the implants were placed in these diabetic rabbits. The implant stability quotient (ISQ) and bone-to-implant contact (BIC) values were significantly higher in the ILTN group (ISQ: 61.8, BIC: 41.3%) and SLA group (ISQ: 62.6, BIC: 46.3%) than in the machined group (ISQ: 53.4, BIC: 20.2%), but the difference in the BIC percentage between the SLA and ILTN groups was not statistically significant (P=0.628). However, the bone area percentage was significantly higher in the ILTN group (78.0%) than in the SLA group (52.1%; P=0.000). Conclusions: The: ILTN dental implants showed better stability (ISQ) and BIC than the machined implants; however, these values were similar to the commercially used SLA implants in the 2-week diabetic rabbit model.

Highly Porous Tungsten Oxide Nanowires As Resistive Sensor for Reducing Gases

  • Nguyen, Minh Vuong;Hoang, Nhat Hieu;Jang, Dong-Mi;Jung, Hyuck;Kim, Do-Jin
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 추계학술발표대회
    • /
    • pp.16.1-16.1
    • /
    • 2011
  • Gas sensor properties of $WO_3$ nanowire structures have been studied. The sensing layer was prepared by deposition of tungsten metal on porous single wall carbon nanotubes followed by thermal oxidation. The morphology and crystalline quality of $WO_3$ material was investigated by SEM, TEM, XRD and Raman analysis. A highly porous $WO_3$ nanowire structure with a mean diameter of 82 nm was obtained. Response to CO, $NH_3$ and $H_2$ gases diluted in air were investigated in the temperature range of $100{\sim}340^{\circ}C$ The sensor exhibited low response to CO gas and quite high response to $NH_3$ and $H_2$ gases. The highest sensitivity was observed at $250^{\circ}C$ for $NH_3$ and $300^{\circ}C$ for $H_2$. The effect of the diameters of $WO_3$ nanowires on the sensor performance was also studied. The $WO_3$ nanowires sensor with diameter of 40 nm showed quite high sensitivity, fast response and recovery times to $H_2$ diluted in dry air. The sensitivity as a function of detecting gas concentrations and gas sensing mechanism was discussed. The effect of dilution carrier gases, dry air and nitrogen, was examined.

  • PDF

수용액 및 비수용액에서 양극산화법으로 형성된 TiO2 나노튜브의 구조 연구 (Morphological Studies on TiO2 Nanotubes Formed by Anodizing in Aqueous and Non-Aqueous Solutions)

  • 김병조;문성모;정용수;김병관
    • 한국표면공학회지
    • /
    • 제43권4호
    • /
    • pp.180-186
    • /
    • 2010
  • $TiO_2$ nanotubes were formed on Ti by anodizing in 1 M $H_3PO_4$ + 0.3 M HF and 0.1 M $NH_4F$ + 2% $H_2O$ in ethylene glycol, and their surface and cross-sectional morphologies were observed using FE-SEM as a function of anodizing time and applied voltage. The cross-section of the $TiO_2$ nanotubes was readily observed from the small pieces of nanotubes remaining near the scratch lines after scratching of the anodized surface. $TiO_2$ nanotubes was observed to grow faster and thicker in non-aqueous solution than in aqueous solution. Diameter of $TiO_2$ nanotubes was proportional to the applied voltage, irrespective of the type of the electrolyte, and it is recommended to use non-aqueous solutions for the preparation of larger diameter of $TiO_2$ nanotubes.

알루미늄 하부층이 탄소나노튜브의 성장 및 전계방출 특성에 미치는 영향 (Effect of an AI underlayer on the Growth of Carbon Nanotubes and Their Field Emission Characteristics)

  • 이승환;곽정춘;이한성;이내성
    • 한국전기전자재료학회논문지
    • /
    • 제21권2호
    • /
    • pp.162-172
    • /
    • 2008
  • We studied the effect of an Al underlayer on the growth of carbon nanotubes (CNTs) and their field emission characteristics, First of all, CNTs were grown on the Invar catalyst layers with different thickness of 1 to 10 nm, showing that the CNT length was saturated for the catalyst 5 nm or thicker. The CNTs grown on the 5-nm-thick catalyst were ${\sim}10{\mu}m$ long and ${\sim}30nm$ in diameter. Second, an Al underlayer was applied between the catalyst layer and the Ti diffusion barrier to reduce the diameters of CNTs for better field emission properties by forming spherical Al oxide particles on which smaller catalyst nanoparticles would occur. The optimal thickness of an Al underlayer underneath the 5-nm-thick catalyst was ${\sim}15nm$, producing the CNTs with the length of ${\sim}15{\mu}m$ and the diameter of ${\sim}15nm$. The field emission measurements, following the tape activation, showed that the thinner and longer CNTs gave rise to better field emission performance with the lower turn-on and threshold electric fields.

플라즈마 화학 기상 증착법에서 DC bias가 인가된 탄소나노튜브의 수직성장과 전계방출 특성 (The Vertical Growth of CNTs by DC Bias-Assisted PECVD and Their Field Emission Properties.)

  • 정성회;김광식;장건익;류호진
    • 한국전기전자재료학회논문지
    • /
    • 제15권4호
    • /
    • pp.367-372
    • /
    • 2002
  • The vertically well-aligned carbon nanotubes(CNTs) were successfully grown on Ni coated silicon wafer substrate by DC bias-assisted PECVD(Plasma Enhanced Chemical Vapor Deposition). As a catalyst, Ni thin film of thickness ranging from 15~30nm was prepared by electron beam evaporator method. In order to find the optimum growth condition, the type of gas mixture such as $C_2H_2-NH_3$ was systematically investigated by adjusting the gas mixing ratio at $570^{\circ}C$ under 0.4Torr. The diameter of the grown CNTs was 40~200nm and the diameter of the CNTs increased with increasing the Ni particles size. TEM images clearly showed carbon nanotubes to be multiwalled. The measured turn-on field was $3.9V/\mu\textrm{m}$ and an emission current of $1.4{\times}10^4A/\textrm{cm}^2$ was $7V/\mu\textrm{m}$. The CNTs grown by bias-assisted PECVD was able to demonstrate high quality in terms of vertical alignment, crystallization of graphite and the processing technique at low temperature of $570^{\circ}C$ and this can be applied for the emitter tip of FEDs.

Growth and Characterization of Vertically well Aligned Crbon Nanotubes on Glass Substrate by Plasma Enhanced Hot Filament Chemical Vapor deposition

  • Park, Chong-Yun;Yoo, Ji-Beom
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.210-210
    • /
    • 2000
  • Vertically well aligned multi-wall carbon nanotubes (CNT) were grown on nickel coated glass substrates by plasma enhanced hot filament chemical vapor deposition at low temperatures below 600$^{\circ}C$. Acetylene and ammonia gas were used as the carbon source and a catalyst. Effects of growth parameters such as pre-treatment of substrate, plasma intensity, filament current, imput gas flow rate, gas composition, substrate temperature and different substrates on the growth characteristics of CNT were systematically investigated. Figure 1 shows SEM image of CNT grown on Ni coated glass substrate. Diameter of nanotube was 30 to 100nm depending on the growth condition. The diameter of CNT decreased and density of CNT increased as NH3 etching time etching time increased. Plasma intensity was found to be the most critical parameter to determine the growth of CNT. CNT was not grown at the plasma intensity lower than 500V. Growth of CNT without filament current was observed. Raman spectroscopy showed the C-C tangential stretching mode at 1592 cm1 as well as D line at 1366 cm-1. From the microanalysis using HRTEM, nickel cap was observed on the top of the grown CNT and very thin carbon amorphous layer of 5nm was found on the nickel cap. Current-voltage characteristics using STM showed about 34nA of current at the applied voltage of 1 volt. Electron emission from the vertically well aligned CNT was obtained using phosphor anode with onset electric field of 1.5C/um.

  • PDF

산화아연 나노튜브의 벽 두께에 따른 에탄올 가스 검출특성 (The Effect of Wall Thickness of ZnO Nanotubes on the Ethanol Gas Sensing Performance)

  • 강우승
    • 한국표면공학회지
    • /
    • 제50권3호
    • /
    • pp.225-229
    • /
    • 2017
  • ZnO nanotubes were synthesized to investigate the effect of wall thickness on the ethanol gas sensing performance. The wall thickness of the nanotubes was varied from approximately 20 to 60 nm. Transmission electron microscopy, X-ray diffraction and SAED (Selected Area Electron Beam Diffraction) analyses showed that the synthesized nanotubes were polycrystalline structured ZnO with the diameter of approximately 200-300nm. The ZnO nanotubes sensor with an optimum wall thickness of 51.8nm showed approximately 8 times higher response, compared to that with 21.14nm wall thick nanotubes, to the ethanol concentration of 500 ppm at the temperature of $300^{\circ}C$. The wall thickness of 51.8nm was found to be a little larger than 46nm, which was theoretically derived Debye length. Along with the study of the wall thickness effect on the performance of the sensors, the mechanisms of gas sensing of the polycrystalline ZnO nanotubes are also discussed.

Template Wetting Process에 의한 Pt 나노튜브 제작 (Pt Nanotubes by Template Wetting Process)

  • 황지훈;양비룡
    • 열처리공학회지
    • /
    • 제22권1호
    • /
    • pp.23-26
    • /
    • 2009
  • Pt nanotubes with diameter of 200 nm were fabricated by simple and convenient method of Template-Wetting Process. Porous alumina membranes were prepared by 2 step anodic oxidation as the template. To improve wetting properties and lower surface energy, pt solution was mixed with polymer. Polymer was removed completely during annealing. Grain growth process of pt nanotubes during baking and furnace annealing was examined by FE-SEM and XRD.