• Title/Summary/Keyword: Naked-eye

Search Result 409, Processing Time 0.028 seconds

Oxidation Added Wet Cleaning Process for Synthetic Diamonds (합성 다이아몬드를 위한 산화제가 첨가된 세정공정)

  • Song, Jeongho;Lee, Jiheon;Song, Ohsung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.3597-3601
    • /
    • 2013
  • In this study, a wet cleaning process, P II, using aqua-regia and sulfuric acid mixture with oxidant agent ($K_2S_2O_8$, $P_2O_5$, $KMnO_4$, $H_2O_2$ etc) is proposed to remove the metastable phase of graphite such as graphene and DLC for high quality synthetic diamonds. The process employed the conventional acid cleaning process (P I) as well as P I+P II to remove the graphite related impurities from the 200um-diamond powders synthesized at 7GPa-$1500^{\circ}C$-5minutes. The degree of cleaning after P I and P I+P II has been observed by naked-eye, optical microscopy, micro-Raman spectroscopy, and TGA-DTA. After P I+P II, the color of diamond became more vividly yellow with enhanced saturation with naked eye and optical microscopy analysis. Moreover, the disappearance of diamond-like-carbon (DLC) peak ($1440cm^{-1}$) observed by Raman spectroscopy confirmed the decrease in amount of remaining impurities. TGA-DTA results showed that the graphite impurities first started to dissolve at $770.91^{\circ}C$ after PI process. However, the pyrolysis started at $892.18^{\circ}C$ after P I+P II process because of the dissolution of pure diamonds. This result proved the effective dissolution of the metastable phase of graphite. We expect that the proposed P II process may enhance the quality of diamonds through effective removal of surface impurities.

Studies on Color Classification of Fancy Veneer Flooring Board with HSI Color Model (HSI 색상모델을 이용한 마루판 무늬목의 색상분류에 관한 연구(1))

  • Seo, Jun-Won;Park, Byung-Su;Chong, Song-Ho;Park, Heon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.4 s.132
    • /
    • pp.23-29
    • /
    • 2005
  • The fancy veneer flooring board is high value-added wooden material. The classification of the flooring boards by the observation with the naked eye causes color difference among fancy veneers. It turned out that this inaccuracy of color difference among fancy veneers increased in case of the identification by metamerism or the flooring construction. Therefore, this study was performed to classify fancy veneers produced from 3 species such as Tilia sp., Betula sp., and Acer sp. which were identified with the naked eye by Light and Dark grade, by using CIELAB. In addition, each specie's threshold on CIERGB was investigated and a range of hue, saturation and intensity by an application of HSI color model were studied. Intensity of the HIS color model could be the best value to be used when color, saturation and intensity of the HSI color model were used for the classification of the flooring board's color. In addition, it seemed that color range of all three criteria lied between $45^{\circ}$ and $55^{\circ}$. In the case of identification by threshold of RGB element, considering only specific color element value is unlikely to lead to accurate classification of fancy veneers of flooring board.

Radioopacity of Absorbable Plate containing Hydroxyapatite and Gold(Au); A Preliminary Report (Hydroxyapatite와 금(Au)이 혼합된 흡수성 고정판의 방사선비투과성; 예비 실험)

  • Kim, Yong Ha;Nam, Hyun Jae;Lee, Joon Ho;Kim, Kap Joong;Kim, Yeon Jung;Choi, Sik Young
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.419-422
    • /
    • 2008
  • Purpose: Absorbable bone fixation materials for operation of facial bone fracture are composed of poly- lactic acid(PLA) & poly-glycolic acid(PGA). These materials are absorbed after facial bone healing period. Therefore, these materials are harmless in human body. But because of it's radioopacity, the number and the location of the materials are not checked in follow-up X-ray examination. We studied absorbable bone fixation materials checked radiological examination. So, we made the absorbable plate composed of PLA, Hydroxyapatite (HA) and Gold(Au). Methods: Plate 1 was consisted of pure PLA. Plate 2 was consisted of PLA(50%) and HA(50%). Plate 3 - 7 were consisted of PLA(50%), and variable composition of HA & Au. The ratio of Au was as following. From the plate 3 to plate 7, the Au ratio was 1%, 5%, 10%, 17%, and 25%, respectively. Total 3 examinations were used-naked eye examination, simple X-ray examination, and Haunsfield unit of plate in CT examination. Results: Naked eye examination found out that the color of plate 1 was most white. As the Au ratio increases, the color of plate was getting close to khaki color. the radioopacity of plate 2 was similar cortical bone of face in simple X-ray. The Haunsfield unit of cortical bone of face was 1000 HU. Haunsfield unit of titanium plate was 2900 HU. Haunsfield unit of plate 1 through plate 7 were -242, 1489, 1776, 3052, 3092, 3095, and 3095, respectively. Conclusion: Radioopacity of plate 2 was similar to cortical bone of face. In CT examination, Hanusfield unit of plate 2 was similar to Hanusfield unit of cortical bone of face. Hanusfield unit of plate 4 - 7 were similar to Hanusfield unit of titanium plate. So to trace bone fixation materials after facial bone surgery, the best ratio of Au is about 1 - 5%. If this study is applied to facial bone surgery, radiologic follow up would be easy after facial bone surgery.

Histopathological study of acute toxicity of ammonia to the eel, Anguilla japonica in high temperature and pH levels (고수온(高水溫) 고(高)pH에서 뱀장어에 미치는 암모니아 급성독성(急性毒性)의 병리조직학적(病理組織學的) 연구(硏究))

  • Kim, Min-Soo;Yang, Han-Choon
    • Journal of fish pathology
    • /
    • v.9 no.2
    • /
    • pp.147-155
    • /
    • 1996
  • This study was carried out to examine the acute toxic effects of ammonia to the eel, Anguilla japonica in high temperature and pH levels by histopathological observations. The eels of 40 g average body weight were exposed to 4 different concentrations of total ammonia (0, 10, 20, 30 mg/$\ell$) for 24~120 hours. Each concentration was treated under 4 different levels of pH (7.5, 8.0, 8.5, 9.0) and each of these treatments was tested at 2 different temperatures ($27^{\circ}C$, $32^{\circ}C$). Histopathological changes in gill tissues were observed by hematoxylin-eosin stain. As increasing of pH (from 7.5 to 9.0), water temperature (from $27^{\circ}C$ to $32^{\circ}C$), total ammonia concentration (from 0 mg/$\ell$ to 30 mg/$\ell$) and exposure time (from 24 hours to 120 hours), gill discolorated to dark brown with the naked eye and gill tissues showed hypertrophy of gill lamellae, winding of the secondary gill lamellae, epitherial separation and necrosis histopathologically. When gill lamellae epithelium was separated from the blood vessels, gill discolorated to dark brown with the naked eye.

  • PDF

The Observationi of User Behaviors of the Urban Plaza using Time-Lapse Record-A case study of Chungryangri Station Plaza- (Time-Lapse 촬영방법을 이용한 도심 광장의 이용행태에 관한 연구 -청량리 역광장을 사례로-)

  • 조창완;진양교
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.3
    • /
    • pp.199-212
    • /
    • 1998
  • The ultimate goal of this study can be summed up as follows: First, the utility of Time-Lapse that observes and records people's behavior will be shown and its merits and demerits will be discussed through comparing with other data-collecting methods such as the naked- eye observation, and the specific way in which Time-Lapse can be put to use will be suggested. Second, analysis of use behavior boserved in the plaza of Chungryangri station by Time-Lapse will be made, on the basis of which suggestions will be made concerning planing, designing, layout, and management of the station plaza. Time-Lapse can observe and records the plaza of Chungryangri Staton through 6 different ways of recording in Time-Lapse: 30 seconds, every minute, every two minutes, second every five minutes, every one tenth of a second, and every one fifth of a second, and these different ways of recording were analyzed through comparison from one to each other to check their respective utilities. And also analysis of tracks of pedestrians, density, and use behavior of users were made, according to which the way in which Time-Lapse can be utilized was examined. Several useful results obtained from this study are shown as follows. First, Time-Lapse made it possible to continuously observe for a long time using minimu efforts, and a single tape which is able to cover from 12 hours up to 25 days is useful for observing variation of behavior in space with the passage of time and seasons. Second, among six ways of recording, the recording every one tenth of a second and every one fifth of a second are useful for finding the tracks of pedestrians, the number of users, the member compositions, the time spent in one place, and manner of use. And besides the moving direction and its purpose can be recognized in a short time, which makes it possile to see where crossings of moving directions occur. Third, the recording every thirty seconds, every minute, every two minutes, and every five minutes are useful for analyzing the density in space as well as for finding the number of users and frequency of facilities use. In particular the recording every thirty seconds made it possible to keep the track of pedestrians' walking, and to observe even slowly moving motions such as cleaning. But when the recording interval exceeds one minute, this was not possible. Fourth, time-lapse has advantages over the naked eye observation in several respects. Time-lapse can measure observed behavior and density in terms of number, and locate the position of users. Time-Lapse, if accompanied by other methods such as interviewing and question that can examine psychological aspects like satisfaction or the purpose of use and be a useful device for space studies.

  • PDF

A study on the honeycomb entry and exit counting system for measuring the amount of movement of honeybees inside the beehive (벌통 내부 꿀벌 이동량 측정을 위한 벌집 입·출입 계수 시스템 연구)

  • Kim, Joon Ho;Seo, Hee;Han, Wook;Chung, Wonki
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.857-862
    • /
    • 2021
  • Recently, rapid climate change has had a significant impact on the bee ecosystem. The decrease in the number of bees and the change in the flowering period have a huge impact on the harvesting of beekeepers. Accordingly, attention is focused on smart beekeeping, which introduces IoT technology to beekeeping. According to the characteristics of beekeeping, it is impossible to continuously observe the beehive in the hive with the naked eye, and the condition of the hive is mostly dependent on knowledge from experience. Although a system that can measure partly through sensors such as temperature/humidity change inside the hive and measurement of the amount of CO2 is applied, there is no research on measuring the movement path and amount of movement of bees inside the beehive. Part of the migration of honeybees inside the hive can provide basic information to predict the most important cleavage time in beekeeping. In this study, we propose a device that detects the movement path of bees and measures and records data entering and exiting the hive in real time. The device proposed in this study was developed according to the honeycomb standard of the existing beehive so that beekeeping farms could use it. The development method used a photodetector that can detect the movement of bees to configure 16 movement paths and to detect the movement of bees in real time. If the measured honeybee movement status is utilized, the problem of directly observing the colony with the naked eye in order not to miss the swarming time can be solved.

Comparison on accuracy of porcelain color reproducibility using two colorimeters (2종의 측색기에 의한 도재 색조 재현의 정확성 비교)

  • Lee, Tai-Il;Ahn, Jin-Soo;Kim, Young-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.348-355
    • /
    • 2009
  • Statement of problem: Although the use of colorimeter to improve the accuracy of tooth color measurement has increased, it is real situation that there is almost no comparative study about the accuracy among various colorimeters. Purpose: The purpose of this study is to compare the accuracy of porcelain color reproducibility using ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan) and Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany). Material and methods: Color of 2M2 and 3M2 shade tap of Vitapan 3D Master shade guide were measured using the above two colorimeters. Porcelain specimens were fabricated through this data. The porcelain systems used were Vintage Halo Porcelain system with ShadeEye-Ncc dental chroma meter, and VitaOmega900 Porcelain system with Shadepilot$^{TM}$ system. Colors of shade tap models and porcelain specimen were measured with spectrophotometer, and calculated delta E based on the results. Results: The following results were obtained. 1. Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility compared to ShadeEye-Ncc dental chroma meter (P <.05). 2. The result showed the difference of porcelain color reproducibility according to shade of Shade tap which is model. More suitable porcelain color reproducibility was shown at 3M2 shade tap than at 2M2 shade tap (P <.05). 3. The average of ${\Delta}E*$ of porcelain specimens which was made by the two colorimeters was 4.44-6.14, so the difference of shade was shown through the naked eye. Conclusion: Shadepilot$^{TM}$ system showed more suitable porcelain color reproducibility. When using ShadeEye-Ncc dental chromameter, it will be necessary to improve accuracy through coloring various parts of the whole tooth.

Measurement of Size of Ovaries, Follicles, and Corpus Lutea by Ultrasonography with Jeju Horse (초음파상을 이용한 제주마의 난소, 난포 및 황체의 크기 측정)

  • Yoo, J.G.;Kang, M.S.;Son, W.J.;Yun, Y.M.;Lee, J.M.;Kang, T.Y.
    • Journal of Embryo Transfer
    • /
    • v.22 no.3
    • /
    • pp.191-194
    • /
    • 2007
  • The purpose of the present study was to set up basic information of size and status of ovaries by using ultrasonography to retrieve in vivo matured oocytes with ovum pick- up method. Ovaries were collected from the abattoir in Jeju in May and June which is breeding season. When the size of ovaries on ultrasonography was compared with real size measured by caliper, no significant difference was shown (p<0.05). The number of preovulatory follicles (>21mm) was investigated with ultrasonography and naked eyes. Ultrasonography group had 0.83 preovulatory follicles per ovary and naked-eye group had 0.75 preovulatory follicle per ovary and their average size was 2.86 cm and 2.34 cm, respectively. The average number of follicle was 4.25 with ultrasonography and 4.38 with naked eyes. There was no significant difference considering the size of follicle and number of follicle between ultrasonography and actual size except for the size of preovulatory follicle, suggesting that information of ultrasonography is able to use for OPU or other reproductive technology of mare.

Effects of Ato-tang on DNCB-induced atopic dermatitis in Mice (아토피피부염 동물 병태 모델에서 아토탕의 개선효과)

  • Kim, Gun-Woo;Kim, Dong-Hee
    • The Korea Journal of Herbology
    • /
    • v.31 no.4
    • /
    • pp.79-85
    • /
    • 2016
  • Objectives : The aim of this study is to investigate anti-atopic dermatitis effect using ato-tang.Methods : Ato-tang was external treatment to NC/Nga mice for 4 weeks, where atopic dermatitis was induced by DNCB at 1% and 0.4% for 3 weeks. Atopic dermatitis index score was measured using eye observation and picture evaluation. The histopathological change of dorsal skin was observed by hematoxylin and eosin (H&E) staining. Cytokines including IL-4, IL-5 and IL-13 were measured by Luminex or reverse transcriptase polymerase chain reaction (RT-PCR) analysis and immunoglobulin E (IgE) was measured by ELISA reader.Results : The dorsal skin of Ato-tang group showed decrease in erythema, pruritus, dry skin, edema, excoriation, erosion and lichenification level through naked eye observations. Immunoglobulin cell infiltration and the thickness of epidermis were significantly decreased in the dorsal skin compared to control. Production of Th2 cytokines (IL-4, IL-5, IL-13) and IgE level in serum were all significantly decreased, in comparison with control. In addition, mRNA expression level of Th2 cytokines (IL-4, IL-5, IL-13) in spleen was decreased, in comparison with control.Conclusion : The results indicated that external treatment of ato was improved skin barrier function in the symptoms of atopic dermatitis disease. Also, atopic dermatitis factors where cytokine as well as immunoglobulin E in serum and mRNA expression were decreased, respectively, in comparison with control. Therefore, we suggest that ato could be effectively used as a external therapeutic drug based on atopic dermatitis factors.

Shade Comparative Analysis of Natural tooth Measured by Visual and Two Colorimeters(ShadeEye®,Shadepilot®) (2종 측색기와 시각을 이용한 자연치아의 색조 비교 분석)

  • An, Jin-Hee;Choi, Mee-Ra;Shim, Hye-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.81-93
    • /
    • 2013
  • The objectives were to evaluate the accuracy of shade selection by human visual system(VS) and 2 different colorimeters ($ShadeEye^{(R)}$(SE) and Shadepilot (SP)). Maxillary anterior teeth of 30 volunteers which had no caries or restorations were included in the study. Firstly, the accordance in shade selection by 3 dentists and 2 colorimeters was investigated. Secondly, the color of the teeth were measured by 1 observer's naked eye and 2 colorimeters under different illumination conditions (Sunny versus cloudy day). Additionally testing of inter-observer variability selected colors by 2 novice and 2 experienced dentists were compared. For comparing visual and 2 different colorimeters, SP(60%) showed significantly highest rate of accordance than the visual (23.3%) or SE (16.7%) and lowest mean ${\Delta}E$ ($2.62{\pm}0.74$ versus $3.83{\pm}1.38$;SE or $4.04{\pm}1.61$;VS)(p<0.001). If accuracy of shade selection were measured using VS, the mean ${\Delta}E$ value of cloudy day was higher than that of sunny day ($4.35{\pm}1.70$ versus $3.53{\pm}1.31$; p<0.001). There were no significant difference of the mean ${\Delta}E$ value between sunny and cloudy day in both SE and SP. Inter- observer repeatability was higher in 2 experienced group (73.3%) than novice group (36.7%). The mean ${\Delta}E$ of experienced group was lower than that of novice group ($3.60{\pm}1.47$ versus $4.70{\pm}1.67$; p<0.001). Colorimeters (SE or SP) is more accurate and more reproducible compared with human shade assessment. Using visual system may be limited by cloudy and inexperience of tester, then more experience and using colorimeters may be helpful of raising the accurate repeatability of shade selection.