• Title/Summary/Keyword: Multiple electrodes

Search Result 97, Processing Time 0.023 seconds

The Performance Analysis of Direct Current Electromagnetic Propulsion in Seawater

  • Kong, Yeong-Kyung;Park, Tai-In;Kim, Yun-Sik;Noh, Chang-Joo
    • Journal of Energy Engineering
    • /
    • v.2 no.1
    • /
    • pp.38-44
    • /
    • 1993
  • Electromagnetic seawater thrusters may be classified into four general categories : internal duct dc, external field dc, internal peristaltic ac, and external peristaltic ac. Internal duct dc thrusters offer the advantages of low magnetic field leakage, simple construction, and potentially high reliability. The most efficient internal duct configuration consists of converging inlet nozzle and a straight discharge duct. Ideal efficiency calculations based on the one-dimensional Bernoulli equation show that thrusters should be designed with large cross-sectional areas and operate at low discharge velocities. In practice, this may be accomplished by using multiple thruster ducts. Conductivity enhancement, high magnetic fields, and long electrodes will also improve efficiency.

  • PDF

A MODEL STUDY ON MULTISTEP RECOVERY OF ACTINIDES BASED ON THE DIFFERENCE IN DIFFUSION COEFFICIENTS WITHIN LIQUID METAL

  • CHUN, YOUNG-MIN;SHIN, HEON-CHEOL
    • Nuclear Engineering and Technology
    • /
    • v.47 no.5
    • /
    • pp.588-595
    • /
    • 2015
  • This study presents an effective method for additional recovery of residual actinides in liquid electrodes after the electrowinning process of pyroprocessing. The major distinctive feature of this method is a reactor with multiple reaction cells separated by partition walls in order to improve the recovery yield, thereby using the interelement difference in diffusion coefficients within the liquid electrode and controlling the selectivity and purity of element recovery. Through an example of numerical simulation of the diffusion scenarios of individual elements, we verified that the proposed method could effectively separate the actinides (U and Pu) and rare-earth elements contained in liquid cadmium. We performed a five-step consecutive recovery process using a simplified conceptual reaction cell and recovered 58% of the initial amount of actinides (U + Pu) in high purity (${\geq}99%$).

Voltammetric Analysis on a Disposable Microfluidic Electrochemical Cell

  • Chand, Rohit;Han, Dawoon;Kim, Yong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1175-1180
    • /
    • 2013
  • A microfabricated electrochemical cell comprising PDMS-based microchannel and in-channel gold microelectrodes was fabricated as a sensitive and a miniature alternative to the conventional electroanalytical systems. A reproducible fabrication procedure enabled patterning of multiple microelectrodes integrated within a PDMS-based fluidic network. The active area of each electrode was $200{\mu}m{\times}200{\mu}m$ with a gap of $200{\mu}m$ between the electrodes which resulted in a higher signal to noise ratio. Also, the PDMS layer served the purpose of shielding the electrical interferences to the measurements. Analytes such as potassium ferrocyanide; amino acid: cysteine and nucleoside: guanosine were characterized using the fabricated cell. The microchip was comparable to bulk electrochemical systems and its applicability was also demonstrated with flow injection based rapid amperometric detection of DNA samples. The device so developed shall find use as a disposable electrochemical cell for rapid and sensitive analysis of electroactive species in various industrial and research applications.

SNP Detection Using DNA Chip (DNA칩을 이용한 SNP의 검출)

  • Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1319-1321
    • /
    • 2006
  • This research aims to develop the multiple channel electrochemical DNA chip that has the above characteristic and be able to solve the problems. At first, we fabricated a high integration type DNA chip array by lithography technology. It is able to detect a plural genes electrochemically after immobilization of a plural probe DNA and hybridization of non-labeling target DNA on the electrodes simultaneously. It suggested that this DNA chip could recognize the sequence specific genes. It suggested that multichannel electrochemical DNA microarray is useful to develop a portable device for clinical gene diagnostic system.

  • PDF

Polypyrrole Film Studied by Three-Parameter Ellipsometry

  • 김동래;이덕환;백운기
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.8
    • /
    • pp.707-712
    • /
    • 1996
  • Growth and changes of electronically conducting polypyrrole (PPy) in the form of thin films polymerized on metal electrodes were investigated by electrochemical and in situ three-parameter ellipsometry methods at the wavelength of 632.8 nm. Although the optical equations produced multiple sets of solution, it was possible to determine a unique set of thickness and the optical constants of a film by auxiliary measurements and/or physical reasoning. The changes in the thickness and the optical properties of the polymers during polymerization and electrochemical oxidation/reduction was successfully followed by the three-parameter ellipsometric technique. The optical properties of the polymers continuously changed as the film grew. The imaginary part of the refractive index of polypyrrole seemed to be dominantly determined by the existence of an absorption band around the visible range.

Quantitative Determination of $UO2^{2+}$ with Modified $[Ru(v-bpy)_3]^{2+}$ Polymer Film Electrode (수식된 $[Ru(v-bpy)_3]^{2+}$ 고분자 피막전극을 이용한 U(VI)의 정량)

  • Cha, Seong-Keuck
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.1
    • /
    • pp.17-23
    • /
    • 2000
  • Electrodes of the polycationic film with electropolymerized $[Ru(v-bpy)_3]^{2+}$ having about 1:1 ratio of $PF6^-/ClO_4^-$as the doped counter ions, were modified with xylenol orange and diethylditbiocarbamate by ion exchange which had stability constant as 38.6 and 17.5 respectively. These electrodes were employed in the quantitative multiple determination of U(W) in solution. The working electrode of electrochemical cell for the analytical signal was Pt/p-$[Ru(v-bpy)_3]^{2+}$, ligand, U(VI) with Ag/AgCl reference elecrode. In the stripping voltammetry. electrode process was electron transfer controlled one and calibration curves at the ranges of $1.0{\times}10^{-3}{\sim}1.0{\times}10^{-7}$ M had excellent relationship as 0.99 and relative standard deviation as 5${\sim}$8%.

  • PDF

Effect of Electrode Configuration on the Substrate Degradation in Microbial Fuel Cells (미생물연료전지에서 전극구조가 기질분해에 미치는 영향 연구)

  • Shin, Yujin;Lee, Myoung-Eun;Park, Chi-Hoon;Ahn, Yongtae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.8
    • /
    • pp.489-493
    • /
    • 2017
  • Microbial fuel cells (MFC) are bio-electrochemical processes that can convert various organic materials present in wastewater into electrical energy. For scaling-up and practical application of MFC, it is necessary to investigate the effect of anode size, electrode distance, and total area of anode on substrate degradation. Spaced electrode assembly (SPA) type microbial fuel cell with multiple anodes treating domestic wastewater was used for simulation. According to computer simulation results, the shorter the distance between electrodes than the size of single electrode, the faster the substrate degradation rate. Particularly, when the total area of the anode is large, the substrate decomposition is the fastest. In this study, it was found that the size of the anode and the distance between the electrodes as well as the cathode electrode, which is known as the rate-limiting step in the design of the microbial fuel cell process, are also important factors influencing the substrate degradation rate.

320-Channel Multi-Frequency Trans-Admittance Scanner(TAS) for Anomaly Detection (도전율 및 유전율이 다른 병소의 검출을 위한 320-채널 다주파수 Trans-Admittance Scanner(TAS))

  • Oh, Tong-In;Lee, Min-Hyoung;Kim, Hee-Jin;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.84-94
    • /
    • 2007
  • In order to collect information on local distribution of conductivity and permittivity underneath a scan probe, we developed a multi-frequency trans-admittance scanner (TAS). Applying a sinusoidal voltage with variable frequency on a chosen distal part of a human body, we measure exit currents from 320 grounded electrodes placed on a chosen surface of the subject. The electrodes are packaged inside a small and light scan probe. The system includes one voltage source and 17 digital ammeters. Front-end of each ammeter is a current-to-voltage converter with virtual grounding of a chosen electrode. The rest of the ammeter is a voltmeter performing digital phase-sensitive demodulation. Using resistor loads, we calibrate the system including the scan probe to compensate frequency-dependent variability of current measurements and also inter-channel variability among multiple. We found that SNR of each ammeter is about 85dB and the minimal measurable current is 5nA. Using saline phantoms with objects made from TX-151, we verified the performance of the lesion estimation algorithm. The error rate of the depth estimation was about 19.7%. For the size estimate, the error rate was about 15.3%. The results suggest improvement in lesion estimation algorithm based on multi-frequency trans-admittance data.

Abatement of CF4 Using RF Plasma with Annular Shape Electrodes Operating at Low Pressure (환상형상 전극구조를 갖는 저압 RF plasma를 이용한 CF4 제거)

  • Lee, Jae-Ok;Hur, Min;Kim, Kwan-Tae;Lee, Dae-Hoon;Song, Young-Hoon;Lee, Sang-Yun;Noh, Myung-Keun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.690-696
    • /
    • 2010
  • Abatement of perfluorocompounds (PFCs) used in semiconductor and display industries has received an attention due to the increasingly stricter regulation on their emission. In order to meet this circumstance, we have developed a radio frequency (RF) driven plasma reactor with multiple annular shaped electrodes, characterized by an easy installment between a processing chamber and a vacuum pump. Abatement experiment has been performed with respect to $CF_4$, a representative PFCs widely used in the plasma etching process, by varying the power, $CF_4$ and $O_2$ flow rates, $CF_4$ concentration, and pressure. The influence of these variables on the $CF_4$ abatement was analyzed and discussed in terms of the destruction & removal efficiency (DRE), measured with a Fourier transform infrared (FTIR) spectrometer. The results revealed that DRE was enhanced with the increase in the discharge power and pressure, but dropped with the $CF_4$ flow rate and concentration. The addition of small quantity of $O_2$ lead to the improvement of DRE, which, however, leveled off and then decreased with $O_2$ flow rate.

Wafer-Level Fabrication of a Two-Axis Micromirror Driven by the Vertical Comb Drive (웨이퍼 레벨 공정이 가능한 2축 수직 콤 구동 방식 마이크로미러)

  • Kim, Min-Soo;Yoo, Byung-Wook;Jin, Joo-Young;Jeon, Jin-A;Park, Il-Heung;Park, Jae-Hyoung;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.148-149
    • /
    • 2007
  • We present the design and fabrication prcoess of a two-axis tilting micromirror device driven by the electrostatic vertical comb actuator. A high aspect-ratio comb actuator is fabricated by multiple DRIE process in order to achieve large scan angle. The proposed fabrication process enables a mirror to be fabricated on the wafer-scale. By bonding a double-side polished (DSP) wafer and a silicon-on-insulator (SOI) wafer together, all actuators on the wafer are completely hidden under the reflectors. Nickel lines are embedded on a Pyrex wafer for the electrical access to numerous electrodes of mirrors. An anodic bonding step is implemented to contact electrical lines with ail electrodes on the wafer at a time. The mechanical angle of a fabricated mirror has been measured to be 1.9 degree and 1.6 degree, respectively, in the two orthogonal axes under driving voltages of 100 V. Also, a $8{\times}8$ array of micromirrors with high fill-factor of 70 % is fabricated by the same fabrication process.

  • PDF