• Title/Summary/Keyword: Multiple electrodes

Search Result 97, Processing Time 0.022 seconds

An Analysis of the Frequency-Dependent Resultant Ground Impedance of Vertical Ground Electrodes Installed in Parallel (병렬로 시공된 수직 접지전극의 합성접지임피던스의 주파수의존성 분석)

  • Lee, Bok-Hee;Cho, Sung-Chul;Seong, Chang-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • This paper deals with the experimental results of the frequency-dependent resultant ground impedance of vertical ground electrodes installed with a regular n-polygon. In order to propose an effective method of installing the vertically-driven multiple ground electrodes used to obtain the low ground impedance, the resultant ground impedance of ground electrodes installed with a regular n-polygon were measured as functions of the number of ground electrodes and the frequency of test currents and the results were discussed based on the potential interferences among ground electrodes. As a consequence, the effect of potential interference on the resultant ground impedance of vertical ground electrodes is frequency-dependent and it is significant in the low frequency of a few hundreds [Hz]. The resultant ground impedance of multiple vertical ground electrodes is not decreased in linearly proportion to the number of ground electrodes due to the overlapped potential interferences. Also the distributed-parameter circuit model considering the potential interference, the frequency-dependent relative permittivity and resistivity of soil was proposed. The simulated results of the frequency-dependent resultant ground impedance of multiple vertical ground electrodes are in good agreement with the measured data.

Fabrication of Micro Electrodes by Reverse EDM and Its Applications (역방전 가공을 이용한 미세 전극 제작과 그 응용)

  • Choi Se Hwan;Kim Bo Hyun;Park Byung Jin;Chu Chong Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.159-164
    • /
    • 2005
  • For increasing productivity of micro electrochemical machining (MECM), the application of multiple electrodes was introduced. The electrodes were fabricated by reverse electrical discharge machining (REDM). By REDM micro electrodes with various shapes can be machined easily. According to capacitance and applied voltage, machining characteristics of reverse EDM were investigated and the optimal conditions for stable machining were suggested. By using multiple electrodes and a channel-shape electrode, holes and channels were machined on stainless steel by ECM.

Grounding Resistance and Current Characteristics of the Planar Earth Structure using Multiple Discharge Paths (다중방전 경로를 이용한 편상접지체의 접지저항 및 전류특성)

  • Kim, Young-Sun;Kim, Dong-Min;Lee, Ki-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1564-1570
    • /
    • 2016
  • This study proposes a newly modified form of existing ground electrodes in order to secure trust of grounding system for large current caused by a stroke of lightning. Proposed planar earth structure has a several needle electrodes around a circular rod and 4 plane electrodes in all directions. The plane electrodes are fused with the insulator on the linear rod, so that they're electrically isolated. The concept is to increase the discharge amount of earth structure using multiple discharge paths like needle and plane electrodes. To check the discharge efficiency of the suggested scheme, the discharge currents are compared with typically used two kinds of ground rods. To ensure accuracy in the measurement of the discharge current, the same material was used for the comparison model. Also, the ground resistance are simulated by CDEGS commercial software and the results are compared with measured data. Based on this kind of experimental study, the suggested ground rod can be used when designing a ground system or when constructing a ground system at the site.

MDOF Ionic-Polymer-Metal-Composite Actuators with Selectively Grown Multiple Electrodes (선택적으로 성장 시킨 다중 전극판을 갖는 다자유 IPMC 작동기)

  • Jeon, Jin-Han;Oh, Il-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.294-298
    • /
    • 2008
  • The ionic polymer-metal composite actuators with selectively grown multiple electrodes were developed to mimic the swimming locomotion of a fish. The developed method is based on combining electroplating with the electroless chemical reduction using the patterned mask. The advantages of this fabrication method are that the initial compositing between the polymer and platinum particles can be assured by the chemical reduction method, and the thickness of each electrode can be controlled easily and rapidly by electroplating. By using the fabricated actuator with a multiple degree of freedom, the oscillatory wave of the flexible membrane actuator was generated and a twisting motion was also realized to verify the possibility of mimicking the fish-like locomotion. The frequency response function was analyzed to investigate the natural frequency and the damping factor by a mechanical shaker and direct electrical excitation through the swept-sine method. Present results show that this novel method can be a promising technique to easily pattern each of multiple electrodes and to implement the biomimetic motion of the polymer actuators with good mechanical bending performance.

  • PDF

Flexible Cu-In-Se Quantum Dot-Sensitized Solar Cells Based on Nanotube Electrodes (나노튜브 전극을 기반으로 한 플렉서블 양자점 감응 태양전지)

  • Kim, Jae-Yup
    • Journal of Powder Materials
    • /
    • v.26 no.1
    • /
    • pp.45-48
    • /
    • 2019
  • Quantum dots (QDs) are an attractive material for application in solar energy conversion devices because of their unique properties including facile band-gap tuning, a high-absorption coefficient, low-cost processing, and the potential multiple exciton generation effect. Recently, highly efficient quantum dot-sensitized solar cells (QDSCs) have been developed based on CdSe, PbS, CdS, and Cu-In-Se QDs. However, for the commercialization and wide application of these QDSCs, replacing the conventional rigid glass substrates with flexible substrates is required. Here, we demonstrate flexible CISe QDSCs based on vertically aligned $TiO_2$ nanotube (NT) electrodes. The highly uniform $TiO_2$ NT electrodes are prepared by two-step anodic oxidation. Using these flexible photoanodes and semi-transparent Pt counter electrodes, we fabricate the QDSCs and examine their photovoltaic properties. In particular, photovoltaic performances are optimized by controlling the nanostructure of $TiO_2$ NT electrodes.

Positive Peaked Electrically Compound Action Potentials in Cochlear Implant Recipients (인공와우 이식자에서 Positive Peaked 청신경 복합활동전위)

  • Heo, Seung-Deok
    • Phonetics and Speech Sciences
    • /
    • v.1 no.2
    • /
    • pp.25-30
    • /
    • 2009
  • Animal experiments have shown that the positive peaked electrically compound action potentials (ECAPs) can be recorded in round window, intracochlear, and nerve trunk by stimulating a monopolar pulse. However, positive peaked ECAPs of cochlear implant recipients have never been reported because ECAPs are recorded from intracochlear electrodes after bipolar stimulation. In our experiment, the positive peaked ECAPs were recorded from 18 intracochlear electrodes in cochlear implant recipients with multiple cochlear anomalies. Thresholds in each channel were measured and the latency of P-, N-wave, and amplitude of P-N were analyzed. These results were identical with the electrically auditory brainstem response (EABR) on the input-output characteristics. In conclusion, the positive peaked ECAPs from the cochlear implant recipients are antidromic ECAPs recorded by perimodiolar electrodes stimulating cochlear implants with multiple anomalies. Therefore, positive peaked ECAPs can be used as useful audiological tools to evaluate the eighth nerve ending.

  • PDF

Dynamic Electrical Impedance Tomography with IMM Scheme

  • Kang, Suk-In;Kim, Bong-Seok;Kim, Min-Chan;Kim, Sin;Lee, Yoon-Joon;Kim, Kyung-Youn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.45.4-45
    • /
    • 2002
  • In EIT, an array of disjoint electrodes is attached on the boundary of the object and a set of small alternating electrical currents is injected into the object through these electrodes, and then the corresponding set of voltages is measured on the same array of the electrodes. The objective in EIT is to estimate the resistivity distribution inside the object based on the set of measured voltages and injected currents. In this paper, we proposed a new dynamic EIT reconstruction scheme based on the interacting multiple model (IMM) algorithm. The main contribution of the proposed scheme is that multiple models are employed for the state evolution to get around the modeling uncertainty. Extensi...

  • PDF

Electrohydrodynamic Process Supplemented by Multiple-Nozzle and Auxiliary Electrodes for Fabricating PCL Nanofibers (멀티노즐/보조전극-Electrohydrodynamic 공정을 통한 PCL 나노파이버 제작)

  • Yoon, Hyeon;Kim, Geun-Hyung;Kim, Wan-Doo
    • Polymer(Korea)
    • /
    • v.32 no.4
    • /
    • pp.334-339
    • /
    • 2008
  • Recently electro spinning is a widely used simple technique to prepared micro- to nanometer-sized fiber of various polymers. In general, a normal multiple-nozzle electro spinning system has been difficult to achieve high production-rate fabricating micro/nanofibers due to the interference of electric field between individual nozzles in the process. To reduce the interference effect of electric field between nozzles, we developed a multi-nozzle electrospinning system supplemented with auxiliary electrodes. Poly($\varepsilon$-carprolactone)(PCL), which has good mechanical property and biocompatibility, was electrospun by the multi-nozzle electro spinning system. Electrospinnability, product rate, and size uniformity of spun fibers for the system with and without auxiliary electrodes were characterized. As a result, the multi-nozzle electrospinning system supplemented with auxiliary electrodes provides excellently stable processability and showed high mass productivity of PCL-nanofibers relative to a normal multi-nozzle electro spinning system.

Structural health monitoring of CFRPs using electrical resistance by reduced peripheral electrodes

  • Park, Young-Bin;Roh, Hyung Doh;Lee, In Yong
    • Smart Structures and Systems
    • /
    • v.28 no.6
    • /
    • pp.737-744
    • /
    • 2021
  • In this study, structural health monitoring (SHM) methods of carbon fiber reinforced plastics (CFRPs) were investigated using electrical resistance. The developed sensing technique monitored electrical resistance in accordance with the impact damage of a CFRP. The changes in electrical resistances with multiple electrode sets enabled SHM without extra sensors so that this technique can be called self-sensing. Moreover, this study proposed electrodes only at peripheral side of a structure to minimize the number of electrodes compared to those in an array which has square number of sensors as the sensing area increases. For the intensive investigation, electromechanical sensitivity in terms of electrode distance was analyzed and optimized under drop weight impact testing. Then, SHM methods with electrodes in an array and electrodes in peripheral edges were comparatively investigated. The developed methods successfully localized impact damages into 2D coordinates. Furthermore, damage severity can be shown with a damage map by calculating electrical resistance change ratio. Therefore, structural health self-sensing system using electrical resistance was successfully developed with the minimum number of electrodes.

A Study on the Correlationship between Wearable ECG and Clinical ECG Measurements (웨어러블 심전도 측정과 임상 심전도 측정과의 상관관계에 대한 연구)

  • Lee, Kang-Hwi;Lee, Seong-Su;Kim, Sang-Min;Lee, Hyeok-Jae;Min, Kyoung-Jin;Kang, Hyun-Kyu;Lee, Joo-Hyeon;Kwak, Hwy-Kuen;Ko, Yun-Soo;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1690-1698
    • /
    • 2018
  • Recent advances in ICT technology have transformed many of our daily lives and attracted a lot of attention to personal health. Heart beat measurement that reflects cardiac activities has been used in various fields such as exercise evaluation and psychological state evaluation for a long time, but its utilization method is limited due to its differentiation from clinical electrocardiogram. Therefore, in this study, we could observe the change of the measured signal according to the change of the distance and the position of the measuring electrodes which are non-standard electrode configuration. Based on the electric dipole model of the heart, correlation with clinical electrocardiogram could be confirmed by synthesizing multiple surface potentials measured with a shorter electrode distance than standard one. From the electromagnetic point of view, the distance between the measuring electrodes corresponds to the distance that the electric potential by the cardiac electric dipole moves, and the electric potential measured at the body surface is proportional to the moving distance of the electric potential. Therefore, it is preferable to make the distance between electrodes as long as possible, and to position the measuring electrode close to the ventricle rather than the atrium. In addition, it was found that standard electrocardiographic waveforms could be synthesized by using arithmetic sum of multiple measuring electrodes due to the relationship of electrical dipole vectors, which is obtained by dividing and positioning a plurality of measuring electrodes on a reference electrode line, such as Lead-I, Lead-II direction. Also, we obtained a significant Pearson correlation coefficient ($r=0.9113{\pm}0.0169$) as a result of synthetic experiments on four subjects.