• 제목/요약/키워드: Multiple drilling

검색결과 59건 처리시간 0.023초

거골의 전내측에 큰 골극이 동반된 족관절의 내측 충돌증후군 (Medial impingement syndrome of the ankle associated with large anteromedial osteophyte of talus - A case report -)

  • 유선오;김종진
    • 대한족부족관절학회지
    • /
    • 제6권1호
    • /
    • pp.124-128
    • /
    • 2002
  • After a severe ankle sprain, the incidence of residual complaints, particularly on the medial side of the joint, is high. We experienced a case of medial impingement between medial malleolus and anteromedial osteophyte of talus, specially in the dorsiflexion of the right ankle. Twenty five-year-old male was complained tenderness and chronic pain over the medial side of the right anklel for 3 years after an inversion sprain of the ankle. The plain radiography revealed a bony osteophyte on the anteromedial side of talus. The patient was treated by the open arthrotomy of the ankle. At surgery, impingement between articular surface of medial malleolus and osteophyte of the talus was observed when ankle dorsiflexion was done. Chondral lesion of medial malleolus and chondromalacic degeneration on anteromedial talus was viewed. Surgical removal of osteophyte on talus and debridement and multiple drilling of chondral lesion on medial malleolus was done. The symptom was improved. After postoperative 1 year, recurrence was not.

  • PDF

나노 다공 구조를 가진 알루미나 재료의 UV 레이저 미세가공에 관한 실험적 기초 연구 (Basic Experimental Investigations to UV Laser Micro-Machining of Nano-Porous Alumina Ceramic Material)

  • 신보성;이정한
    • 한국기계가공학회지
    • /
    • 제11권1호
    • /
    • pp.62-67
    • /
    • 2012
  • Recently UV laser is widely used to process micro parts using various materials such as polymers, metals and ceramics because it has a very high intensity at the focused spot area. It is generally known that there are still some difficulties for alumina($Al_2O_3$) ceramics to directly make micro patterns like holes and lines on the surface of working material using 355nm UV laser because the alumina has a very low absorption coefficient at that wavelength. But nowadays new alumna with nano-porous holes is developed and applied to advanced micro functional parts of IT, BT and BT industries. In this paper, we are going to show the mechanism of photo-thermal ablation for nano-porous ceramics. Inside hole there is a lot of multiple reflections along the depth of hole. Experimentally we can find the micro hole drilling and micro grooving on the surface of nano-porous alumina.

A parameter study on the pre-heat treatment for the fabrication of a large grain YBCO bulk superconductor without intermediate grinding step

  • Hong, Yi-Seul;Kim, Chan-Joong;Lee, Hee-Gyoun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권1호
    • /
    • pp.1-6
    • /
    • 2020
  • This is a parameter study for the direct fabrication of a large grain YBCO bulk superconductors using Y2O3, BaCO3 and CuO powders without any grinding step. The cracks, which have been formed due to volume contraction during calcination step, have been prevented by controlling the heating rate at 930~950 ℃. It has been observed that multi-grain growth has occurred due to the dissolution of Sm123 seed due to the retention of carbon in Ba-Cu-O melt. In order to accelerate the carbon release in prior calcination heat treatment, the reduction of pellet thickness and the drilling of artificial holes have been applied. Single-grain YBCO bulk superconductor has been successfully fabricated by stacking multiple thin slab. However, the crack formation has been rather prominent for the compact with artificial holes. The use of buffer pellet, which is supposed to act as diffusion barrier, has prevented the dissolution of Sm123 seed crystal and has led to the growth of single grain of high content of carbon containing specimen.

비전형적 대퇴골과 자발성 골괴사증(증례 보고) (Familial Osteonecrosis of Femoral Condyle -Atypical Spontaneous Osteonecrosis of the Knee Involving Medial & Lateral Condyles in Young Patient with Familial Occurence-)

  • 이명철;조현철;김태균;성인호;성상철
    • 대한관절경학회지
    • /
    • 제2권2호
    • /
    • pp.185-188
    • /
    • 1998
  • Spontaneous osteonecrosis of the knee was first described by Ahlbck et al in 1968 as the spontaneous and sudden onset of severe pain, usually on the medial side of the knee joint, in old age(>60 years) with no specific etiologic factors. They differentiate the disease from osteochondritis dissecans, osteoarthritis, fracture, infection, neuropathic joint and secondary osteonecrosis of the knee joint. So far many investigators described this disease but had never observed cases developed in young patient with familial occurrence. The report presented here is a case of spontaneous osteonecrosis of both medial and lateral femoral condyles involving the bilateral knee joint that were treated by arthorscopic loose body removal and multiple drilling.

  • PDF

Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque

  • Katic, Visnja;Kamenar, Ervin;Blazevic, David;Spalj, Stjepan
    • 대한치과교정학회지
    • /
    • 제44권4호
    • /
    • pp.177-183
    • /
    • 2014
  • Objective: To determine the unique contribution of geometrical design characteristics of orthodontic mini-implants on maximum insertion torque while controlling for the influence of cortical bone thickness. Methods: Total number of 100 cylindrical orthodontic mini-implants was used. Geometrical design characteristics of ten specimens of ten types of cylindrical self-drilling orthodontic mini-implants (Ortho Easy$^{(R)}$, Aarhus, and Dual Top$^{TM}$) with diameters ranging from 1.4 to 2.0 mm and lengths of 6 and 8 mm were measured. Maximum insertion torque was recorded during manual insertion of mini-implants into bone samples. Cortical bone thickness was measured. Retrieved data were analyzed in a multiple regression model. Results: Significant predictors for higher maximum insertion torque included larger outer diameter of implant, higher lead angle of thread, and thicker cortical bone, and their unique contribution to maximum insertion torque was 12.3%, 10.7%, and 24.7%, respectively. Conclusions: The maximum insertion torque values are best controlled by choosing an implant diameter and lead angle according to the assessed thickness of cortical bone.

Two-dimensional nonconforming finite elements: A state-of-the-art

  • Choi, Chang-Koon;Kim, Sun-Hoon;Park, Young-Myung;Chung, Keun-Young
    • Structural Engineering and Mechanics
    • /
    • 제6권1호
    • /
    • pp.41-61
    • /
    • 1998
  • A state-of-the-art report on the new finite elements formulated by the addition of nonconforming displacement modes has been presented. The development of a series improved nonconforming finite elements for the analysis of plate and shell structures is described in the first part of this paper. These new plate and shell finite elements are established by the combined use of different improvement schemes such as; the addition of nonconforming modes, the reduced (or selective) integration, and the construction of the substitute shear strain fields. The improvement achieved may be attributable to the fact that the merits of these improvement techniques are merged into the formation of the new elements in a complementary manner. It is shown that the results obtained by the new elements give significantly improved solutions without any serious defects such as; the shear locking, spurious zero energy mode for the linear as well as nonlinear benchmark problems. Recent developments in the transition elements that have a variable number of mid-side nodes and can be effectively used in the adaptive mesh refinement are presented in the second part. Finally, the nonconforming transition flat shell elements with drilling degrees of freedom are also presented.

원통의 용접변형 및 잔류응력에 대한 연구 (A Study on the Welding Deformations and Residual Stresses for Circumferential Welded Cylinders)

  • 류기열;엄동석
    • 대한조선학회논문집
    • /
    • 제35권4호
    • /
    • pp.55-64
    • /
    • 1998
  • 본 연구에서는 구멍뚫기 기법을 사용하여 여러 입열량과 두께대 직경을 가진 원통에서 원주용접에 의해 발생되는 잔류응력과 용접변형을 측정하였다. 그 결과, 입열량과 원통 두께대 직경이 커짐에 따라 축 및 원주 잔류응력은 커지게 됨을 확인하였으며 이것은 Fujita 등의 결과와 잘 일치하였다. 원통 원주용접 시의 지배 파라메터인 입열량과 두께 대 직경비는 축 및 원주방향의 잔류응력과 용접변형의 분포 및 크기에 영향을 미치고 있음을 확인하였으며, 다중회귀분석법을 적용하여 실험결과의 범위내에 있는 원주용접된 원통에 대한 잔류응력과 용접변형을 예측할 수 있는 근사식을 도출하였다.

  • PDF

A non-symmetric non-periodic B3-spline finite strip method

  • Kim, Kyeong-Ho;Choi, Chang-Koon
    • Structural Engineering and Mechanics
    • /
    • 제18권2호
    • /
    • pp.247-262
    • /
    • 2004
  • In the earlier application of the spline finite strip method(FSM), the uniform B3-spline functions were used in the longitudinal direction while the conventional interpolation functions were used in the transverse direction to construct the displacement filed in a strip. To overcome the shortcoming of the uniform B3-spline, non-periodic B-spline was developed as the displacement function. The use of non-periodic B3-spline function requires no tangential vectors at both ends to interpolate the geometry of shell and the Kronecker delta property is also satisfied at the end boundaries. Recently, non-periodic spline FSM which was modified to have a multiple knots at the boundary was developed for the shell analysis and applied to the analysis of bridges. In the formulation of a non-symmetric spline finite strip method, the concepts of non-periodic B3-spline and a stress-resultant finite strip with drilling degrees of freedom for a shell are used. The introduction of non-symmetrically spaced knots in the longitudinal direction allows the selective local refinement to improve the accuracy of solution at the connections or at the location of concentrated load. A number of numerical tests were performed to prove the accuracy and efficiency of the present study.

전자뇌관과 다단장약을 이용한 발파 사례 연구 (A Case Study on Multiple-deck-charge Blasting with Electronic Detonators)

  • 고태영;신창오;이효;이승철
    • 화약ㆍ발파
    • /
    • 제30권2호
    • /
    • pp.52-58
    • /
    • 2012
  • 싱가포르 DTL2 C915 건설공사 중 TBM 발진을 위한 개착구간의 암발파 공사를 위해 당초 전기뇌관과 ANFO로 발파시공이 계획되었으나 1회 발파공수 제한 및 가시설에 대한 엄격한 진동관리 규정 등으로 인해 작업공정이 많이 지연되어 TBM 발진을 위한 예정된 공기를 준수하지 못하는 것으로 검토되었다. 따라서 암발파 공법의 효율을 개선하고 1회 발파공수 및 파쇄면적의 최대화를 위해 다단장약이 검토되었으며, 다단장약의 효율성을 높이기 위해 정밀성이 장점인 전자뇌관이 선정되었다. 다단장약 적용으로 천공장이 길어짐에 따라 커지는 암반 구속력에 대응하기 위해 폭약의 위력을 증대시키는 방안으로 Emulsion Cartridge 폭약을 적용하였다. 그 결과 발파효율과 시공성을 개선함과 동시에 가시설의 안정성을 확보할 수 있었다.

골신티그라피에 의한 Hydroxyapatite 안구삽입물로의 섬유혈관증식 평가 (Evaluation of Fibrovascular Ingrowth into the Hydroxyapatite Ocular Implant by $^{99m}Tc$-MDP Bone Scintigraphy)

  • 범희승;송호천;김지열;정상기;박영걸
    • 대한핵의학회지
    • /
    • 제27권2호
    • /
    • pp.256-260
    • /
    • 1993
  • Hydroxyapatite 안구삽입물내로의 섬유혈관증식 여부를 진단하는데 $^{99m}Tc$-MDP 골신티그라피가 유용한지를 알아보기 위해, 전남대학교병원 안과에서 안구적출술 후 hydoxyaptite 안구삽입물을 삽입하고 골신티그라피 검사를 시행한 13예의 환자의 골신티그라피 17예를 분석하고, 이들에서 의안부착을 위해 안구삽입물에 구멍을 뚫을 때 출혈이 있는지를 관찰하여 섬유혈관증식 여부를 확인하였다. 대상환자의 연령은 21세부터 56세까지 분포하였고(평균연령 38세), 성별로는 남자 10, 여자 3예였다. 이 중 2예에서는 2번씩, 또 1예에서는 3번 검사를 시행하였으므로 시행한 골신티그라피는 17번이었고, 이 17예의 검사소견을 분석하였다. 평면상은 정성적으로 판독하였는 데, 안구삽입물에 섭취가 안면골보다 많은 정도를 4+, 안면골과 같은 정도를 3+, 주변 안면골보다 작은 경우를 2+, 섭취가 정상 안구보다 조금 더 진한 정도를 1+로 정하였다. 단면상의 경우는 정상안과 비교한 섭취율을 구하였으며, 그 공식은 (삽입물의 방사능/반대측 안와의 방사능)으로 하였다. 대상환자 모두의 골신티그라피 평면영상에서 1 이상의 섭취를 보였고, 단면상의 정량분석은 1.18이상의 섭취를 보였다. 골신티그라피를 2번 이상 시행한 3예 중 2예에서는 두번째 시행한 골신티그라피상 $^{99m}Tc$-MDP 섭취의 증가가 관찰되었으나, 나머지 1예에서는 3번 시행한 골신티그라피상 전혀 변화를 관찰할 수 없었다. 또 대상환자에서의 안부착시 출혈 여부를 관찰하였는 바 모든 환자에서 충분한 출혈이 있어 삽입물내로 섬유혈관증식이 있음을 확인하였다. 즉, 골신티그라피상 $^{99m}Tc$-MDP 섭취를 보인 안구삽입물 13예 전예에서 삽입물 내로의 혈관증식을 확인하였다. 결론적으로, hydroxyaptite 안구삽입물내로 섬유혈관증식은 매우 잘 일어나며, 주변 안면골보다 낮은 정도의 섭취만 보이더라도 섬유혈관증식 일어난 상태임을 의미하고, 이 경우 안심하고 2차 천공을 시행할 수 있다는 사실을 확인하였다.

  • PDF