• Title/Summary/Keyword: Multi-source

Search Result 1,651, Processing Time 0.034 seconds

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

Errors in Net Ecosystem Exchanges of CO2, Water Vapor, and Heat Caused by Storage Fluxes Calculated by Single-level Scalar Measurements Over a Rice Paddy (단일 높이에서 관측된 저장 플럭스를 사용할 때 발생하는 논의 이산화탄소, 수증기, 현열의 순생태계교환량 오차)

  • Moon, Minkyu;Kang, Minseok;Thakuri, Bindu Malla;Lee, Jung-Hoon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.17 no.3
    • /
    • pp.227-235
    • /
    • 2015
  • Using eddy covariance method, net ecosystem exchange (NEE) of $CO_2$ ($F_{CO_2}$), $H_2O$ (LE), and sensible heat (H) can be approximated as the sum of eddy flux ($F_c$) and storage flux term ($F_s$). Depending on strength and distribution of sink/source of scalars and magnitude of vertical turbulence mixing, the rates of changes in scalars are different with height. In order to calculate $F_s$ accurately, the differences should be considered using scalar profile measurement. However, most of flux sites for agricultural lands in Asia do not operate profile system and estimate $F_s$ using single-level scalars from eddy covariance system under the assumption that the rates of changes in scalars are constant regardless of the height. In this study, we measured $F_c$ and $F_s$ of $CO_2$, $H_2O$, and air temperature ($T_a$) using eddy covariance and profile system (i.e., the multi-level measurement system in scalars from eddy covariance measurement height to the land surface) at the Chengmicheon farmland site in Korea (CFK) in order to quantify the differences between $F_s$ calculated by single-level measurements ($F_s_{-single}$ i.e., $F_s$ from scalars measured by profile system only at eddy covariance system measurement height) and $F_s$ calculated by profile measurements and verify the errors of NEE caused by $F_s_{-single}$. The rate of change in $CO_2$, $H_2O$, and Ta were varied with height depending on the magnitudes and distribution of sink and source and the stability in the atmospheric boundary layer. Thus, $F_s_{-single}$ underestimated or overestimated $F_s$ (especially 21% underestimation in $F_s$ of $CO_2$ around sunrise and sunset (0430-0800 h and 1630-2000 h)). For $F_{CO_2}$, the errors in $F_s_{-single}$ generated 3% and 2% underestimation of $F_{CO_2}$ during nighttime (2030-0400 h) and around sunrise and sunset, respectively. In the process of nighttime correction and partitioning of $F_{CO_2}$, these differences would cause an underestimation in carbon balance at the rice paddy. In contrast, there were little differences at the errors in LE and H caused by the error in $F_s_{-single}$, irrespective of time.

A Study on Repetition and Multiplicite of Superhero Comics (슈퍼히어로 코믹의 반복과 다양체적 형식에 관한 연구)

  • Park, Seh-Hyuck
    • Cartoon and Animation Studies
    • /
    • s.28
    • /
    • pp.27-53
    • /
    • 2012
  • American superhero comics are being produced in numerous different forms for multiple, and cross-platform media. In cinema, films based on superhero comics top the list of all time box office records. The same phenomenon of the 'Invasion of Superhero' is duplicated in Korean box office 2012, however, the korean fans are not familiar with the superheroes from the publication which provides the original source of characters and stories for other superhero related media products. Based on observing the multiple and vastness of world building characteristics of superhero comic, this paper attempts to associate the continuous creative nature and the infinite repetition of superheroes and comic texts with the identity of superhero on ontological level. First, chapter 2 examines how one superhero exists in multiple and different worlds individually by utilizing the concept of 'multi-universe' or 'multiverse' in comic texts. Initially, duplicating a superhero on multiple settings and series destroyed continuity and allowed contradiction and paradox confused narrative as a whole, but it also gave chances for comics to be more vibrant and experimental with their stories and characters. Chapter 3 analyzes the superhero comic texts in the light of repetition, concept developed by french philosopher Gilles Deleuze, and make the argument that the superheroes and texts are not repeated to generate surplus of source for economic utilitarian purposes, but it is, first and foremost, a repetition of creativeness and capability. Many concepts introduced by Deleuze in his early masterpiece, $\acute{e}$rence et R$\acute{e}$p$\acute{e}$tition> are taken to support this argument. Mainly, his critical views on generality of the identity and his effort to replace the Plato's system of representation with vibrant creative, and renewal energy of r$\acute{e}$p$\acute{e}$tition. According to Deleuze, repetition is similar concept, if not identical, to what Nietzsche called the 'eternal return' which allows the return of the Overhuman or the Superhuman, and he extends his idea that the returning Overhuman is the singular simulacre which opposes the generalization of identity, in the likes of Plato's Idea. Thus, the superhero's identity is ever changing, ever returning, and ever renewing Overhuman. The superhero must be repeated to fully actualize his/her existence. Also, based on Deleuze's reading of Bergson's texts on the Virtual, the superhero, for example Superman, is actualization of his/her multiplisit$\acute{e}$, the internally multiple, and differentiated variations from itself. These every Supermans' multiplisit$\acute{e}$ shares common memory, past, and duration, thus the Virtual of Superman. Superman becomes himself only by actualizing the movement and differentiation from these multiplisit$\acute{e}$ in his virtual on the surface of reality. On chapter 4, a popular Korean comic book character Oh, Hae-Sung's r$\acute{e}$p$\acute{e}$tition and multiplist$\acute{e}$ are analyzed, and makes comparison to that of Superman to distinguish the repetition from r$\acute{e}$p$\acute{e}$tition, and multiplicit$\acute{e}$ from diversity.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

A Study on the Health Insurance Management System; With Emphasis on the Management Operating Cost (의료보험 관리체계에 대한 연구 - 관리비용을 중심으로 -)

  • 남광성
    • Korean Journal of Health Education and Promotion
    • /
    • v.6 no.2
    • /
    • pp.23-39
    • /
    • 1989
  • There have been a lot of considerable. discussion and debate surrounding the management model in the health insurance management system and opinions regarding the management operating cost. It is a well known fact that there have always been dissenting opinions and debates surrounding the issue. The management operating cost varies according to the scale of the management organization and component members characteristics of the insurance carrier. Therefore, it is necessary to examine and compare the management operating cost to the simulated management models developed to cover those eligible for the health insurance scheme in this country. Since the management operating cost can vary according to the different models of management, four alternative management models have been established based on the critical evaluation of existing theories concerned, as well as on the basis of the survey results and simulation attempts. The first alternative model is the Unique Insurance Carrier Model(Ⅰ) ; desigened to cover all of the people with no classification of insurance qualifications and finances from the source of contribution of the insured, nationwide. The second is the Management Model of Large-scale District Insurance Carrier(Ⅱ) ; this means the Korean society would be divided into 21 large districts; each having its own insurance carrier that would cover the people in that particular district with no classification of insurance qualifications arid finances as in Model I. The third is the Management Model of Insurance Carrier Divided by Area and Classified with Occupation if Largescale (Ⅲ) ; to serve the self-employed in the 21 districts divided as in Model Ⅱ. It would serve the employees and their dependents by separate insurance carriers in large-scale similar to the area of the district-scale for the self-employed, so that the insurance qualifications and finances would be classified with each of the insurance carriers: The last is the Management Model of the Multi - insurance Carrier (Ⅳ) based on the Si. Gun. Gu area which will cover their own self- employed people in the area with more than 150 additional insurance carriers covering the employees and their dependents. The manpower necessary to provide services to all of the people according to the four models is calculated through simulation trials. It indicates that the Management Model of Large-scale District Insurance Carrier requires the most manpower among the four alternative models. The unit management operating costs per the insured individuals and covered persons are leveled with several intervals based on the insurance recipients. in their characteristics. The interval levels derived from the regression analysis reveal that the larger the scale of the insurance carriers is in the number of those insured and covered. the more the unit management operating cost decreases. significantly. Moreover. the result of the quadratic functional formula also shows the U-shape significantly. The management operating costs derived from the simulated calculation. on the basis of the average salary and related cost per staff- member of the Health Insurance Societies for Occupational Labours and Korean Medical Insurance Corporation for the Official Servants and Private School Teachers in 1987 fiscal year. show that the Model of Multi-insurance Carrier warrants the highest management operating cost. Meanwhile the least expensive management operating cost is the Management Model of Unique Insurance Carrier. Insurance Carrier Divided by Area and Classified with Occupation in Large-scale. and Large-scale District Insurance Carrier. in order. Therefore. it is feasible to select the Unique Insurance Carrier Model among the four alternatives from the viewpoint of the management operating cost and in the sense of the flexibility in promoting the productivity of manpower in the human services field. However. the choice of the management model for health insurance systems and its application should be examined further utilizing the operation research analysis for such areas as the administrative efficiency and factors related to computer cost etc.

  • PDF

Multi-element Ultrasound Applicator for the Treatment of Cancer in Uterus and Cervix (자궁암 치료용 다채널 초음파 온열치료기)

  • Lee Rena
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.16-23
    • /
    • 2005
  • The objective of this study was to construct multi-element ultrasound applicators for the treatment of gynecologic cancer with high dose rate brachytherapy. For the treatment of uterus, piezo-ceramic crystal transducer (PZT -5A) with outer diameter of 4 mm, wall thickness of 1.3 mm, and length of 24.5 mm was selected. For the treatment of cervix or vagina, it should be possible to insert the applicator into the vagina. Thus, a cylindrical PZT -8 material with outer diameter of 24.5 mm, wall thickness of 1.3 mm, and length of 15.2 mm was selected. The operating frequencies determined by vector impedance measurement were 3.2 MHz for the PZT 5A cylinder (OD=4 mm) and 1.7 MHz for the PZT -8 cylinder (OD: 24.5 mm). The ratios of generated acoustic output power to applied electric power were 33% and 61% for the tandem type crystal and the cylinder type crystal, respectively. The radiated acoustic pressure fields from both transducers were calculated using a Matlab code and measured in water using hydrophone. There was good agreement between measured and calculated acoustic pressure field distribution. For a tandem type transducer, the calculated acoustic pressure field decreased from 0.023 MPa at 10 mm to 0.010 Mpa at 30 mm, the reduction of 57%. For the cylinder type transducer which will be used for the treatment of vagina showed 78% reduction at 15 mm and 66% at 25 mm as compared to values at 5 mm from the surface. Based on the characteristics of the transducers, this study demonstrated the possibility of using the crystals as a heating source. Finally, a 3-element and 4-element prototype applicators were constructed. The 3-element applicator is 75 mm long and 4 mm thick and will be used for the treatment of uterus. The 4-element applicator is 61 mm long and 24.5 mm thick and will be used for the treatment of vagina. Using these applicators, it is possible to generate enough power to increase temperature to therapeutic level.

  • PDF

Retrieval of the Variation of Optical Characteristics of Asian Dust Plume according to their Vertical Distributions using Multi-wavelength Raman LIDAR System (다파장 라만 라이다 관측을 통한 황사의 이동 고도 분포에 따른 광학적 특성 변화 규명)

  • Shin, Sung-Kyun;Park, Young-San;Choi, Byoung-Choel;Lee, Kwonho;Shin, Dongho;Kim, Young J.;Noh, Youngmin
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.5
    • /
    • pp.597-605
    • /
    • 2014
  • The continuous observations for atmospheric aerosols were conducted during 3 years (2009 to 2011) by using Gwangju Institute of Science and Technology (GIST) multi-wavelength Raman lidar at Gwangju, Korea ($35.10^{\circ}N$, $126.53^{\circ}E$). The aerosol depolarization ratios calculated from lidar data were used to identify the Asian dust layer. The optical properties of Asian dust layer were different according to its vertical distribution. In order to investigate the difference between the optical properties of each individual dust layers, the transport pathway and the transport altitude of Asian dust were analyzed by Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) model. We consider that the variation of optical properties were influenced not only their transport pathway but also their transport height when it passed over anthropogenic pollution source regions in China. The lower particle depolarization ratio values of $0.12{\pm}0.01$, higher lidar ratio of $67{\pm}9sr$ and $68{\pm}9sr$ at 355 nm and 532 nm, respectively, and higher ${\AA}ngstr\ddot{o}m$ exponent of $1.05{\pm}0.57$ which are considered as the optical properties of pollution were found. In contrast with this, the higher particle depolarization ratio values of $0.21{\pm}0.09$, lower lidar ratio of $48{\pm}5sr$ and $46{\pm}4sr$ at 355 nm and 532 nm, respectively, and lower ${\AA}ngstr\ddot{o}m$ exponent of $0.57{\pm}0.24$ which are considered as the optical properties of dust were found. We found that the degree of mixing of anthropogenic pollutant aerosols in mixed Asian dust govern the variation of optical properties of Asian dust and it depends on their altitude when it passed over the polluted regions over China.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

The Analysis of Spectral characteristics of Water Quality Factors Uisng Airborne MSS Data (Airborne MSS 자료를 이용한 수질인자의 분광특성 분석)

  • Dong-Ho Jang;Gi-Ho Jo;Kwang-Hoon Chi
    • Korean Journal of Remote Sensing
    • /
    • v.14 no.3
    • /
    • pp.296-306
    • /
    • 1998
  • Airborne MSS data is regarded as a potentially effective data source for the measurement of water quality and for the environmental change of water bodies. In this study, we measured the radiance reflectance by using multi-spectral image of low resolution camera(LRC) which will be reached in the multi-purpose satellite(KOMPSAT) to use the data in analyzing water pollution. We also investigated the possibility of extraction of water quality factors in water bodies by using high resolution remote sensing data such as Airborne MSS. Especially, we tried to extract environmental factors related with eutrophication such as chlorophyll-a, suspended sediments and turbidity, and also tried to develop the process technique and the radiance feature of reflectance related with eutrophication. Although it was difficult to explicitly correlate Airborne MSS data with water quality factors due to the insufficient number of ground truth data. The results were summarized as follows: First, the spectrum of sun's rays which reaches the surface of the earth was consistent with visible bands of 0.4${\mu}{\textrm}{m}$~0.7${\mu}{\textrm}{m}$ and about 50% of total quantity of radiation could be found. The spectrum was reached highest at around 0.5${\mu}{\textrm}{m}$ of green spectral band in visible bands. Second, as a result of the radiance reflectance Chlorophyll-a represented high mainly around 0.52${\mu}{\textrm}{m}$ of green spectral band, and suspended sediments and turbidity represented high at 0.8${\mu}{\textrm}{m}$ and at 0.57${\mu}{\textrm}{m}$, respectively. Finally, as a result of the water quality analysis by using Airborne MSS, Chlorophyll-a could have a distribution image after carrying out ratio of B3 and B5 to B7. Band 7 was useful for making the distribution image of suspended sediments. When we carried out PCA, suspended sediments and turbidity had distributions at PC 1 and PC 4 which are similar to the ground data. Above results can be changed according to the change of season and time. Therefore, in order to analyze the environmental factors of water quality by using LRC data more exactly, we need to investigate the ground data and the radiance feature of reflectance of water bodies constantly. For further studies, we will constantly analyze the radiance feature of the surface of water in wafter bodies by measuring the on-the-spot radiance reflectance and using low resolution satellite image(SeaWiFS). We will also gather the data of water quality analysis in water bodies and analyze the pattern of water pollution.

Effects of streambed geomorphology on nitrous oxide flux are influenced by carbon availability (하상 미지형에 따른 N2O 발생량 변화 효과에 대한 탄소 가용성의 영향)

  • Ko, Jongmin;Kim, Youngsun;Ji, Un;Kang, Hojeong
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.11
    • /
    • pp.917-929
    • /
    • 2019
  • Denitrification in streams is of great importance because it is essential for amelioration of water quality and accurate estimation of $N_2O$ budgets. Denitrification is a major biological source or sink of $N_2O$, an important greenhouse gas, which is a multi-step respiratory process that converts nitrate ($NO_3{^-}$) to gaseous forms of nitrogen ($N_2$ or $N_2O$). In aquatic ecosystems, the complex interactions of water flooding condition, substrate supply, hydrodynamic and biogeochemical properties modulate the extent of multi-step reactions required for $N_2O$ flux. Although water flow in streambed and residence time affect reaction output, effects of a complex interaction of hydrodynamic, geomorphology and biogeochemical controls on the magnitude of denitrification in streams are still illusive. In this work, we built a two-dimensional water flow channel and measured $N_2O$ flux from channel sediment with different bed geomorphology by using static closed chambers. Two independent experiments were conducted with identical flume and geomorphology but sediment with differences in dissolved organic carbon (DOC). The experiment flume was a circulation channel through which the effluent flows back, and the size of it was $37m{\times}1.2m{\times}1m$. Five days before the experiment began, urea fertilizer (46% N) was added to sediment with the rate of $0.5kg\;N/m^2$. A sand dune (1 m length and 0.15 m height) was made at the middle of channel to simulate variations in microtopography. In high- DOC experiment, $N_2O$ flux increases in the direction of flow, while the highest flux ($14.6{\pm}8.40{\mu}g\;N_2O-N/m^2\;hr$) was measured in the slope on the back side of the sand dune. followed by decreases afterward. In contrast, low DOC sediment did not show the geomorphological variations. We found that even though topographic variation influenced $N_2O$ flux and chemical properties, this effect is highly constrained by carbon availability.