• 제목/요약/키워드: Multi-Resolution Analysis

검색결과 412건 처리시간 0.025초

인간의 청각 메커니즘을 적용한 웨이블렛 분석을 통한 음성 향상에 대한 연구 (A study of speech. enhancement through wavelet analysis using auditory mechanism)

  • 이준석;길세기;홍준표;홍승홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(4)
    • /
    • pp.397-400
    • /
    • 2002
  • This paper has been studied speech enhancement method in noisy environment. By mean of that we prefer human auditory mechanism which is perfect system and applied wavelet transform. Multi-resolution of wavelet transform make possible multiband spectrum analysis like human ears. This method was verified very effective way in noisy speech enhancement.

  • PDF

Synthesize multi-walled carbon nanotubes via catalytic chemical vapour deposition method on Fe-Ni bimetallic catalyst supported on kaolin

  • Aliyu, A;Abdulkareem, AS;Kovo, AS;Abubakre, OK;Tijani, JO;Kariim, I
    • Carbon letters
    • /
    • 제21권
    • /
    • pp.33-50
    • /
    • 2017
  • In this study, Fe-Ni bimetallic catalyst supported on kaolin is prepared by a wet impregnation method. The effects of mass of kaolin support, pre-calcination time, pre-calcination temperature and stirring speed on catalyst yields are examined. Then, the optimal supported Fe-Ni catalyst is utilised to produce multi-walled carbon nanotubes (MWCNTs) using catalytic chemical vapour deposition (CCVD) method. The catalysts and MWCNTs prepared using the optimal conditions are characterized using high resolution transmission electron microscope (HRTEM), high-resolution scanning electron microscope (HRSEM), electron diffraction spectrometer (EDS), selected area electron diffraction (SAED), thermogravimetric analysis (TGA), Brunauer-Emmett-Teller (BET), and X-ray diffraction (XRD). The XRD/EDS patterns of the prepared catalyst confirm the formation of a purely crystalline ternary oxide ($NiFe_2O_4$). The statistical analysis of the variance demonstrates that the combined effects of the reaction temperature and acetylene flow rate predominantly influenced the MWCNT yield. The $N_2$ adsorption (BET) and TGA analyses reveal high surface areas and thermally stable MWCNTs. The HRTEM/HRSEM micrographs confirm the formation of tangled MWCNTs with a particle size of less than 62 nm. The XRD patterns of the MWCNTs reveal the formation of a typical graphitized carbon. This study establishes the production of MWCNTs from a bi-metallic catalyst supported on kaolin.

이동창 방식에 의한 고해상도 위성영상에서의 변화탐지 (The Change Detection from High-resolution Satellite Imagery Using Floating Window Method)

  • 임영재;예철수;김경옥
    • 한국지형공간정보학회:학술대회논문집
    • /
    • 한국지형공간정보학회 2002년도 추계학술대회
    • /
    • pp.117-122
    • /
    • 2002
  • 촬영시기가 다른 두 위성영상을 비교 분석하여 시간에 따른 변화정보를 획득하는 변화탐지 기술은 다양한 분야에 유용하게 활용이 가능한 기술이다. 특히 최근 활용기대가 높아지고 있는 고해상도 위성영상을 활용하는 변화탐지 기술은 환경감시, 재해재난 후 피해상황 분석, 불법건축물 감시, 군사적 목적 등 기존의 중 저 해상도 위성영상으로는 얻을 수 없는 유용한 변화정보의 추출이 가능하다. 하지만, 고해상도 위성영상의 특수성으로 인해 저해상도 위성영상에 적용하였던 화소기반 변화탐지 기법을 그대로 사용 할 수 없으며 인공물이나 지형지물의 지리적, 형태학적 특징을 활용하여 변화요소를 탐지하여야 한다. 본 연구에서는 촬영시기가 다른 두 매의 고해상도 위성영상에 대하여 사용자가 신속하고 손쉽게 변화를 감지해 낼 수 있도록 이동창을 이용한 인터페이스를 구성하고, 영상에 대한 육안분석을 통해 사용자가 건물의 신축 및 철거 등 변화를 발견하여 변화지도를 작성할 수 있는 시스템 개발함으로써 반자동 방식에 의한 고해상도 위성영상의 변화탐지 방법을 제시하였다.

  • PDF

Multiscale Implicit Functions for Unified Data Representation

  • Yun, Seong-Min;Park, Sang-Hun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제5권12호
    • /
    • pp.2374-2391
    • /
    • 2011
  • A variety of reconstruction methods has been developed to convert a set of scattered points generated from real models into explicit forms, such as polygonal meshes, parametric or implicit surfaces. In this paper, we present a method to construct multi-scale implicit surfaces from scattered points using multiscale kernels based on kernel and multi-resolution analysis theories. Our approach differs from other methods in that multi-scale reconstruction can be done without additional manipulation on input data, calculated functions support level of detail representation, and it can be naturally expanded for n-dimensional data. The method also works well with point-sets that are noisy or not uniformly distributed. We show features and performances of the proposed method via experimental results for various data sets.

CTF/DYN3D multi-scale coupled simulation of a rod ejection transient on the NURESIM platform

  • Perin, Yann;Velkov, Kiril
    • Nuclear Engineering and Technology
    • /
    • 제49권6호
    • /
    • pp.1339-1345
    • /
    • 2017
  • In the framework of the EU funded project NURESAFE, the subchannel code CTF and the neutronics code DYN3D were integrated and coupled on the NURESIM platform. The developments achieved during this 3-year project include assembly-level and pin-by-pin multiphysics thermal hydraulics/neutron kinetics coupling. In order to test this coupling, a PWR rod ejection transient was simulated on a MOX/UOX minicore. The transient is simulated using two different models of the minicore. In the first simulation, both codes model the core with an assembly-wise resolution. In the second simulation, a pin-by-pin fuel-centered model is used in CTF for the central assembly, and a pin power reconstruction method is applied in DYN3D. The analysis shows the influence of the different models on global parameters, such as the power and the average fuel temperature, but also on local parameters such as the maximum fuel temperature.

A Study on an Automatic Multi-Focus System for Cell Observation

  • Park, Jaeyoung;Lee, Sangjoon
    • Journal of Information Processing Systems
    • /
    • 제15권1호
    • /
    • pp.47-54
    • /
    • 2019
  • This study is concerned with the mechanism and structure of an optical microscope and an automatic multi-focus algorithm for automatically selecting sharp images from multiple foci of a cell. To obtain precise cell images quickly, a z-axis actuator with a resolution of $0.1{\mu}m$ was designed to control an optical microscope Moreover, a lighting control system was constructed to select the color and brightness of light that best suit the object being viewed. Cell images are captured by the instrument and the sharpness of each image is determined using Gaussian and Laplacian filters. Next, cubic spline interpolation and peak detection algorithms are applied to automatically find the most vivid points among multiple images of a single object. A cancer cell imaging experiment using propidium iodide staining confirmed that a sharp multipoint image can be obtained using this microscope. The proposed system is expected to save time and effort required to extract suitable cell images and increase the convenience of cell analysis.

Transient full core analysis of PWR with multi-scale and multi-physics approach

  • Jae Ryong Lee;Han Young Yoon;Ju Yeop Park
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.980-992
    • /
    • 2024
  • Steam line break accident (SLB) in the nuclear reactor is one of the representative Non-LOCA accidents in which thermal-hydraulics and neutron kinetics are strongly coupled each other. Thus, the multi-scale and multi-physics approach is applied in this study in order to examine a realistic safety margin. An entire reactor coolant system is modelled by system scale node, whereas sub-channel scale resolution is applied for the region of interest such as the reactor core. Fuel performance code is extended to consider full core pin-wise fuel behaviour. The MARU platform is developed for easy integration of the codes to be coupled. An initial stage of the steam line break accident is simulated on the MARU platform. As cold coolant is injected from the cold leg into the reactor pressure vessel, the power increases due to the moderator feedback. Three-dimensional coolant and fuel behaviour are qualitatively visualized for easy comprehension. Moreover, quantitative investigation is added by focusing on the enhancement of safety margin by means of comparing the minimum departure from nucleate boiling ratio (MDNBR). Three factors contributing to the increase of the MDNBR are proposed: Various geometric parameters, realistic power distribution by neutron kinetics code, Radial coolant mixing including sub-channel physics model.

MRPID 제어기의 튜닝 방법연구 (A Study on the MRPID parameter tuning method)

  • 류현준
    • 전자공학회논문지SC
    • /
    • 제44권6호
    • /
    • pp.21-28
    • /
    • 2007
  • Mutiresolution proportional-integral-derivative(MRPID) 제어기는 웨이브렛 기반의 다해상도 응답을 이용해서 에러 신호에 포함되어 있는 잡음과 외란을 제거하는 필터 역할을 해준다. 다해상도 응답의 특징상 샘플링 주파수가 높을 경우 상대적으로 고주파성분이 남아있음으로 인해 응답속도가 떨어지는 대신에 오버슈트가 제거되고, 낮을 경우 신호 성분이 제거되므로 인해 응답속도가 향상되지만 오버슈트가 증가 되는 결과를 보였다. 본 논문에서는 proportional-integral-derivative(PID) 제어기와 MRPID 제어기의 응답을 이용한 샘플링 주파수를 설정하는 기법과, MRPID 제어기의 특성을 고려한 파라미터 설정기법을 제안한다. 모의실험을 통해서 제안된 기법의 타당성을 검증하였다.

웨이블릿 기반의 고속 움직임 예측 기법 (A wavelet-based fast motion estimation)

  • 배진우;선동우;유지상
    • 방송공학회논문지
    • /
    • 제8권3호
    • /
    • pp.297-305
    • /
    • 2003
  • 본 논문에서는 저비트율 부호화에 적합한 웨이블릿 기반의 고속 움직임 예측 기법을 제안한다. 제안한 논문에서는 웨이블릿 계수의 차이를 기반으로 한 중요 블록(significant block : SB) 정보를 사용하여 움직임이 존재하는 블록에 대해 선택적으로 움직임 예측함으로써 움직임 벡터의 수가 증가하는 MRME(multiresolution motion estimation)의 단점을 보완할 수 있었다. 또한 웨이블릿 변환의 특성 중 하나인 해상도 분할 특성을 이용하여 quarter-band까지 움직임을 예측하게 되고, 이에 대한 보간작업으로 영상을 재구성한다. 선택적 움직임 추정과 움직임 보상된 quarter-band의 보간작업을 통해 고주파 부대역에서 존재할 수 있는 예측 오차를 줄일 수 있었으며, 동시에 계산량도 감소시킬 수 있었다. 제안된 기법은 기존의 기법과 비교하여 약 70% 이상의 계산량을 감소시킬 수 있었으며, 영상의 화질 면에서도 0.1 ∼ 1.2dB 정도 향상되어 거의 대등한 PSNR을 유지하는 것을 모의 실험을 통하여 확인하였다.

Optical Design of the DOTIFS Spectrograph

  • 정하은
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.100.2-100.2
    • /
    • 2014
  • The DOTIFS is a new multi-object Integral Field Spectrograph (IFS) planned to be designed and built by the Inter-University Center for Astronomy and Astrophysics, Pune, India, (IUCAA) for cassegrain side port of the 3.6m Devasthal Optical Telescope (DOT) being constructed by the Aryabhatta Research Institute of Observational Sciences, Nainital. (ARIES) It is a multi-integral field unit (IFU) spectrograph which has 370-740nm wavelength coverage with spectral resolution R~1200-2400. Sixteen IFUs with microlens arrays and fibers can be deployed on 8 arcmin field. Each IFU has $8.7^{{\prime}{\prime}}{\times}7.4^{{\prime}{\prime}}$ field of view with 144 spaxel elements. 2304 fibers coming from IFUs are dispersed by eight identical spectrographs with all refractive and all spherical optics. In this work, we show optical design of the DOTIFS spectrograph. Expected performance and result of tolerance and thermal analysis are also shown. The optics is comprised of f=520mm collimator, broadband filter, dispersion element and f=195mm camera. Pupil size is determined as 130mm from spectral resolution and budget requirements. To maintain good transmission down to 370nm, calcium fluoride elements and high transmission optical glasses have been used. Volume Phase Holographic grating is selected as a dispersion element to maximize the grating efficiency and to minimize the size of the optics. Detailed optics design report had been documented. The design was finalized through optical design review and now ready for order optics.

  • PDF