• Title/Summary/Keyword: Multi-Channel Detector

Search Result 96, Processing Time 0.024 seconds

Fixed Decision Delay Detector for Intersymbol Interference Channel (심볼간 간섭 채널을 위한 고정 지연 신호 검출기)

  • Taehyun, Jeon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.9
    • /
    • pp.39-45
    • /
    • 2004
  • A design method is proposed for the sequence detection with fixed decision delay with less hardware complexity using the concept of the Voronoi diagram and its dual, the Delaunay tessellation. This detector design is based on the Fixed Delay Tree Search (FDTS) detection. The FDTS is a computationally efficient sequence detection algerian and has been shown to achieve near-optimal performance in the severe Intersymbol Interference (ISI) channels when combined with decision feedback equalization and the appropriate channel coding. In this approach, utilizing the information contained in the Voronoi diagram or equivalently the Delaunay tessellation, the relative location of the detector input sequence in the multi-dimensional Euclidean space is found without any computational redundancy, which leads to a reduced complexity implementation of the detector.

Study for Multi Channel Radiation Detector Using of Microfilm and Carbon Electrode (탄소막 마이크로필름을 이용한 다채널 전리함 개발에 관한 연구)

  • Shin Kyo Chul;Yun Hyong Geun;Jeong Dong Hyeok;Oh Yong Kee;Kim Jhin Kee;Kim Ki Hwan;Kim Jeung Kee
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.111-115
    • /
    • 2005
  • We have designed the multi channel detector for the quality assurance of clinical photon beams. The detector was composed of solid phantom inserted by six plane-parallel ionization chambers at different depth. The chamber as a mini plane parallel chamber was made of carbon coated microfilms. In this study the electrical characteristics of the six chambers in the solid phantom were evaluated using 6 MV photon beam. The leakage currents were less than 0.5 pA, reproducibility was less than 0.5$\%$, linearity was less than 0.5$\%$, and dose rate effect was less than 0.7$\%$. In addition the effect of dose variation from other chambers was estimated to maximum 0.8$\%$ approximately. The developed detector can be used for quality determination in output dosimetry or measurement of percentage depth dose approximately for clinical photon beam.

  • PDF

Multi-Task FaceBoxes: A Lightweight Face Detector Based on Channel Attention and Context Information

  • Qi, Shuaihui;Yang, Jungang;Song, Xiaofeng;Jiang, Chen
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.10
    • /
    • pp.4080-4097
    • /
    • 2020
  • In recent years, convolutional neural network (CNN) has become the primary method for face detection. But its shortcomings are obvious, such as expensive calculation, heavy model, etc. This makes CNN difficult to use on the mobile devices which have limited computing and storage capabilities. Therefore, the design of lightweight CNN for face detection is becoming more and more important with the popularity of smartphones and mobile Internet. Based on the CPU real-time face detector FaceBoxes, we propose a multi-task lightweight face detector, which has low computing cost and higher detection precision. First, to improve the detection capability, the squeeze and excitation modules are used to extract attention between channels. Then, the textual and semantic information are extracted by shallow networks and deep networks respectively to get rich features. Finally, the landmark detection module is used to improve the detection performance for small faces and provide landmark data for face alignment. Experiments on AFW, FDDB, PASCAL, and WIDER FACE datasets show that our algorithm has achieved significant improvement in the mean average precision. Especially, on the WIDER FACE hard validation set, our algorithm outperforms the mean average precision of FaceBoxes by 7.2%. For VGA-resolution images, the running speed of our algorithm can reach 23FPS on a CPU device.

Design of a Symbol Timing Recovery of QAM Using the Interpolation in AWGN channel (AWGN 채널에서 보간기를 이용한 QAM 방식에 대한 심볼동기회로 설계)

  • 박범대;오동진;김철성
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.77-80
    • /
    • 1999
  • This paper deals with a design of a symbol timing recovery circuit of QAM using the interpolation in AWGN channel. To reduce timing jitter and the amount of processing data, we employ MGA (Modified Gardner Algorithm) as a symbol timing error detector which is called NDA(Nondecision Directed Algorithm). We show the characteristics (S-curve and the variance) of timing error detector with the roll-off factor of a shaping filter, which are compared with GA. Also, we compare the BER curve of interpolation method with that of ideal case. The performance of the STR is shown to be close to that of ideal case. This result shows that this method can be useful to implement symbol timing recovery circuit for multi-level modulation.

  • PDF

Adaptive Multi-Rate(AMR) Speech Coding Algorithm (Adaptive Multi-Rate(AMR) 음성부호화 알고리즘)

  • 서정욱;배건성
    • Proceedings of the IEEK Conference
    • /
    • 2000.06d
    • /
    • pp.92-97
    • /
    • 2000
  • An AMR(Adaptive Multi-Rate) speech coding algorithm has been adopted as a standard speech codec for IMT-2000. It is based on the algebraic CELP, and consists of eight speech coding modes having the bit rate from 4.75 kbit/s to 12.2 kbit/s. It also contains the VAD(Voice Activity Detector), SCR (Source Controlled Rate) operation, and error concealment scheme for robustness in a radio channel. The bit rate of AMR is changed on a frame basis depending on the channel condition. In this paper, we introduced AMR speech coding algorithm and performed the real-time implementation using TMS320C6201, i.e., a Texas Instrument's fixed-point DSP. With the ANSI C source code released from ETSI and 3GPP, we convert and optimize the program to make it run in real time using the C compiler and assembly language. It is verified that the decoded result of the implemented speech codec on the DSP is identical with the PC simulation result using ANSI C code for test sequences. Also, actual sound input/output test using microphone and speaker demonstrates its proper real-time operation without distortions or delays.

  • PDF

Channel Estimation Schemes of W-CDMA TDD Mode Employing Multi-User Detector (다중사용자 수신기법을 적용한 W-CDMA TDD 모드의 채널 추정 기법)

  • 고균병;조영보;권동승;정인철;강창언;홍대식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.3B
    • /
    • pp.237-243
    • /
    • 2002
  • This paper studies the channel estimation schemes of Time Division Duplex (TDD) Code Division Multiple Access (CDMA) system with a parallel interference canceller (PIC) in multi-path fading channels. furthermore, the effective interpolation method which maintains the flexibility of UTRA TDD mode is proposed. By Monte Carlo simulations, it is verified that the proposed interpolation method can be used in order to obtain the proper performance of a multi-stage PIC and in order to reduce the required Eb/No for a given bit error rate (BER).

Development of Measurement System for Industrial Transportable Gamma Ray CT (이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

Fuzzy-ARTMAP based Multi-User Detection

  • Lee, Jung-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.3A
    • /
    • pp.172-178
    • /
    • 2012
  • This paper studies the application of a fuzzy-ARTMAP (FAM) neural network to multi-user detector (MUD) for direct sequence (DS)-code division multiple access (CDMA) system. This method shows new solution for solving the problems, such as complexity and long training, which is found when implementing the previously developed neural-basis MUDs. The proposed FAM based MUD is fast and easy to train and includes capabilities not found in other neural network approaches; a small number of parameters, no requirements for the choice of initial weights, automatic increase of hidden units, no risk of getting trapped in local minima, and the capabilities of adding new data without retraining previously trained data. In simulation studies, binary signals were generated at random in a linear channel with Gaussian noise. The performance of FAM based MUD is compared with other neural net based MUDs in terms of the bit error rate.

Design of Photo-Detector for Particle Sizer Using Laser Diffraction (레이저 회절성에 의한 입자 크기의 계측을 위한 센서 설계)

  • Nam, Boo-Hee;Kang, Sung-Gui;Yu, Tae-U;Bang, Byeong-Ryeol;Jee, Gyu-ln
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.437-440
    • /
    • 1992
  • We design a multi-element photo-detector to measure the size of particles using the diffracted light energy distribution. The light energy that is scattered by particles in the collimated laser beam is collected by the Fourier transform lens and directed to the multi-semicircular concentric annular detecters. The scattered profile measured by the photodetector is sampled by a 32 channel analog-to-digital converter. A nonnegative least squares analysis translates the light energy distribution into the corresponding unique particle size distribution.

  • PDF

Characteristics of dose distribution for virtual wedge (가변형 쐐기필터의 선량분포에 관한 특성)

  • 김부길;김진기
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.125-131
    • /
    • 2001
  • We was investigate the dosimetric characteristics of the virtual wedge and it compared to the conventional fixed wedge. Also we was evaluate the quality factor of the experimental multi-channel dosimetry system for virtual wedge. Recently virtual wedge technique and wedge fraction methods are available through the computer controlled asymmetric collimator or the independent jaw in medical linear accelerator for radiation therapy. The dosimetric characteristics are interpreted by radiation field analyzer RFA-7 system and PTW-UNIDOS system. Experimental multi-channel dosimetry system for virtual wedge was consists of the electrometer, the solid detector and array phantom. The solid detectors were constructed using commercially diodes for the assessment of quality assurance in radiotherapy. And it was used for the point dose measuring and field size scanning. The semiconductor detector and ion chamber were positioned at a dmax, 5 cm, 10 cm, 20 cm depth and its specific ratio was determined using a scanning data. Wedge angles in fixed and virtual type are compared with measurements in water phantom and it is shown that the wedge angle 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$were agree within 1$^{\circ}$ degree in 6, 10 MV photon beams. In PDD and beam flatness, experimental multi-channel disimetry system was capable of reproduceing the measured values usually to within $\pm$2.1% the statistical uncertainties of the data. It was used to describe dosimetric characteristics of virtual wedge in clinical photon beams. Also we was evaluate optimal use of the virtual wedge and improve the quality factor of the experimental multi-channel dosimetry system for virtual wedge.

  • PDF