Efficient Rolling Shutter Distortion Removal using Hierarchical Block-based Motion Estimation

  • Lee, Donggeun;Choi, Kang-Sun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.4
    • /
    • pp.205-211
    • /
    • 2014
  • This paper reports an efficient algorithm for accurate rolling shutter distortion removal. A hierarchical global motion estimation approach for a group of blocks reduces the level of computation by three orders of magnitude. In addition, the motion of each scanline is determined accurately by averaging two candidates obtained through cubic spline interpolation. The experimental results show that the proposed method produces accurate motion information with significant computation reduction and corrects the rolling shutter distortion effectively.

Motion Field Estimation Using U-disparity Map and Forward-Backward Error Removal in Vehicle Environment (U-시차 지도와 정/역방향 에러 제거를 통한 자동차 환경에서의 모션 필드 예측)

  • Seo, Seungwoo;Lee, Gyucheol;Lee, Sangyong;Yoo, Jisang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.12
    • /
    • pp.2343-2352
    • /
    • 2015
  • In this paper, we propose novel motion field estimation method using U-disparity map and forward-backward error removal in vehicles environment. Generally, in an image obtained from a camera attached in a vehicle, a motion vector occurs according to the movement of the vehicle. but this motion vector is less accurate by effect of surrounding environment. In particular, it is difficult to extract an accurate motion vector because of adjacent pixels which are similar each other on the road surface. Therefore, proposed method removes road surface by using U-disparity map and performs optical flow about remaining portion. forward-backward error removal method is used to improve the accuracy of the motion vector. Finally, we predict motion of the vehicle by applying RANSAC(RANdom SAmple Consensus) from acquired motion vector and then generate motion field. Through experimental results, we show that the proposed algorithm performs better than old schemes.

Effect of posture correction training in dental scaling using rapid upper limb assessment and 3D motion analysis (Rapid upper limb assessment와 3차원 동작 분석을 활용한 치석제거 자세교정 교육의 효과)

  • Yoon, Tae-Lim;Min, Ji-Hyun;Kim, Han-Na
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.3
    • /
    • pp.269-280
    • /
    • 2018
  • Objectives: The purpose of this study was to investigate the change in the posture of dental hygiene students and clinical dental hygienists when implementing dental scaling before and after posture correction training using the rapid upper limb assessment (RULA) method and 3D motion analysis. Methods: Thirty-two healthy volunteers performed dental scaling to remove artificial calculus on dental manikin. The movement and angle of the joints were verified by RULA and 3D motion analysis during the procedure. The subjects were also photographed for 1 minute during the procedure for 10 minutes while the calculus was removed. After the removal of the calculus, the subject and the instructor checked the video together. Posture correction training was conducted by the instructor so that the subject could perform the calculus removal operation in the correct posture. Artificial calculus of the adjacent teeth was then removed for the same period of time, and the change in posture was reviewed. Results: The total score of the posture change using RULA was $5.72{\pm}0.58$ before training and $4.31{\pm}0.10$ after training, showing a significant decrease after training (p<0.001), and upper arm, lower arm, wrist position, neck and waist position showed significant decrease after training. The three-dimensional motion analysis showed significant differences according to the criteria measured at all measurement sites except the left shoulder (p<0.05) Conclusions: It was confirmed through RULA and 3D motion analysis that postural correction training using calculus removal images was effective, and that correct postural education is essential to preventing musculoskeletal diseases caused by removal of calculus.

Motion Field Estimation Using U-Disparity Map in Vehicle Environment

  • Seo, Seung-Woo;Lee, Gyu-Cheol;Yoo, Ji-Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.428-435
    • /
    • 2017
  • In this paper, we propose a novel motion field estimation algorithm for which a U-disparity map and forward-and-backward error removal are applied in a vehicular environment. Generally, a motion exists in an image obtained by a camera attached to a vehicle by vehicle movement; however, the obtained motion vector is inaccurate because of the surrounding environmental factors such as the illumination changes and vehicles shaking. It is, therefore, difficult to extract an accurate motion vector, especially on the road surface, due to the similarity of the adjacent-pixel values; therefore, the proposed algorithm first removes the road surface region in the obtained image by using a U-disparity map, and uses then the optical flow that represents the motion vector of the object in the remaining part of the image. The algorithm also uses a forward-backward error-removal technique to improve the motion-vector accuracy and a vehicle's movement is predicted through the application of the RANSAC (RANdom SAmple Consensus) to the previously obtained motion vectors, resulting in the generation of a motion field. Through experiment results, we show that the performance of the proposed algorithm is superior to that of an existing algorithm.

Continuous Half Passive Motion under Distracted External Fixation for the Treatment of Distal Tibial Pilon Fractures (신연 외고정 및 지속적 반수동 운동을 이용한 경골 원위부 필론 골절의 치료)

  • Bae, Su-Young;Chung, Hyung-Jin;Shin, Yong-Woon;Park, Jae-Gu
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.2
    • /
    • pp.146-150
    • /
    • 2010
  • Purpose: Pilon fracture has several serious complications such as joint stiffness, arthrosis and delayed angular deformity. We report short-term results of new treatment modality using distracted dynamic external fixators and early controlled ankle motion. Materials and Methods: Eight cases of severe pilon fractures for which we tried small plate fixation and additional distracted dynamic external fixators from July 2007 to June 2009 were included. Half passive continuous ankle joint motion was allowed under free hinged ring fixators after the operation. The external fixators were removed after two or three months from the surgery. We investigated joint space by radiograph, joint pain, range of motion, patient's satisfaction of treatment protocol. Results: Joints were distracted when external fixators were applied and mean 28% of space loss developed after removal of external fixators. In most of cases, satisfactory alignments were maintained. Regarding range of joint motion, mean dorsiflexion angle was 15 degrees and mean plantarflexion angle was 32 degree in the condition of wearing external fixators. There was mean 8% reduction of range of motion but no further progression of ankle stiffness after removal of external fixators. Dorsiflexion was not improved after that, but plantarflexion angle was improved 10% even after removal of external fixators. Patients were generally in compliance with the treatment protocols with high level of satisfaction. Conclusion: We got good results with distracted dynamic external fixators and early continuous half-passive joint motion for pilon fractures in terms of joint pain and range of motion. Therefore we suggest this new protocol as an alternative modality for severe pilon fractures.

Implant Removal after Percutaneous Short Segment Fixation for Thoracolumbar Burst Fracture : Does It Preserve Motion?

  • Kim, Hyeun Sung;Kim, Seok Won;Ju, Chang Il;Wang, Hui Sun;Lee, Sung Myung;Kim, Dong Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.2
    • /
    • pp.73-77
    • /
    • 2014
  • Objective : The purpose of this study was to evaluate the efficacy of implant removal of percutaneous short segment fixation after vertebral fracture consolidation in terms of motion preservation. Methods : Between May 2007 and January 2011, 44 patients underwent percutaneous short segment screw fixation due to a thoracolumbar burst fracture. Sixteen of these patients, who underwent implant removal 12 months after screw fixation, were enrolled in this study. Motor power was intact in all patients, despite significant vertebral height loss and canal compromise. The patients were divided into two groups by degree of osteoporosis : Group A (n=8), the non-osteoporotic group, and Group B (n=8), the osteoporotic group. Imaging and clinical findings including vertebral height loss, kyphotic angle, range of motion (ROM), and complications were analyzed. Results : Significant pain relief was achieved in both groups at final follow-up versus preoperative values. In terms of vertebral height loss, both groups showed significant improvement at 12 months after screw fixation and restored vertebral height was maintained to final follow-up in spite of some correction loss. ROM (measured using Cobb's method) in flexion and extension in Group A was $10.5^{\circ}$ ($19.5/9.0^{\circ}$) at last follow-up, and in Group B was $10.2^{\circ}$ ($18.8/8.6^{\circ}$) at last follow-up. Both groups showed marked improvement in ROM as compared with the screw fixation state, which was considered motionless. Conclusion : Removal of percutaneous implants after vertebral fracture consolidation can be an effective treatment to preserve motion regardless of osteoporosis for thoracolumbar burst fractures.

The Change of Biomechanical Milieu after Removal of mstnnnentation in lrunbar Arthrodesis Stiffness of fusion Mass: Finite Element Analysis (척추 유합술 후, 인접 분절의 스트레스에 대한 척추경 나사못에 대한 영향)

  • Kang, Kyoung-Tak;Chun, Heoung-Jae;Son, Ju-Hyun;Kim, Ho-Joong
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.664-667
    • /
    • 2008
  • Since the advent of pedicle screw fixation system, posterior spinal fusion has markedly increased This intemal fixation system has been reported to enhance the fusion rates, thereby becoming very popular procedure in posterior spinal arthrodesis. Although some previous studies have shown the complications of spinal instruments removal, i.e. loss of correction and spinal collapse in scoliosis or long spine fusion patients, there has been no study describing the benefit or complications in lumbar spinal fusion surgery of one or two level. In order to clarify the effect of removal of instruments on mechanical motion profile, we simulated a finite element model of instrumented posterolateral fused lumbar spine model, and investigated the change of mechanical motion profiles after the removal of instrumentation.

  • PDF

Blotch Detection and Removal in Old Film Sequences

  • Takahiro-Saito;Takashi-Komatsu;Toru-Iwama;Tomobisa-Hoshi
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1998.06b
    • /
    • pp.16.2-21
    • /
    • 1998
  • Old movies are often corrupted by randomly located blotches and scratches. In this paper were present an efficient method for detection and removal of these distortions. The presented method is composed of two separate steps: the detection process and the restoration process. In the detection process, blotch locations are detected through global motion segmentation, the sequential approach to motion segmentation, a robust model-fit criterion and so on, we form the algorithm for the algorithm for the global motion segmentation tuned to the blotch detection problem. In the restoration process, the missing data of the detected blotch areas are temporally extrapolated from the corresponding image areas at the preceding or the succeeding image frame with considering the global motion segmentation results. We apply the presented method to moving image sequences distorted by artificial blotches. The method works very well and provides a subjective improvement of picture quality.

Numerical Study on Polishing Behavior during Oxide CMP (Oxide CMP 과정에 대한 수치 유동 해석)

  • Kwon, Dal-Jung;Lee, Do-Hyung;Hong, Yi-Koan;Park, Jin-Goo
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.922-927
    • /
    • 2003
  • In this paper, slurry fluid motion, abrasive particle motion, and roles of groove patterns on the pads are numerically investigated in the 2D and 3D geometries. The simulation results are analyzed in terms of experimental removal rate and WIWNU (within wafer non-uniformity) for ILD (inter level dielectric) CMP process. Numerical investigations reveal that the grooves in the pad behave as uniform distributor of abrasive particles and enhance the removal rate by increasing shear stress. Higher removal rate and desirable uniformity are numerically and experimentally observed at the pad with grooves. Numerical analysis is very well matched with experimental results and helpful for understanding polishing mechanism and local physics.

  • PDF

Numerical Study on Polishing Behavior During Oxide CMP (Oxide CMP과정에 대한 수치 운동 해석)

  • Kwon Daljung;Kim Inhwan;Lee Dohyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.4 s.235
    • /
    • pp.435-440
    • /
    • 2005
  • In this paper, slurry fluid motion, abrasive particle motion, and roles of groove patterns on the pads are numerically investigated in the 2D and 3D geometries. The simulation results are analyzed in terms of experimental removal rate and WIWNU (Within Wafer Non-Uniformity) for ILD (Inter Level Dielectric) CMP process. Numerical investigations reveal that the grooves in the pad behave as uniform distributor of abrasive particles and enhance the removal rate by increasing shear stress. Higher removal rate and desirable uniformity are numerically and experimentally observed at the pad with grooves. Numerical analysis is very well matched with experimental results and helpful fur understanding polishing mechanism and local physics.