• Title/Summary/Keyword: Monitoring device

Search Result 1,391, Processing Time 0.035 seconds

Partial Discharge Measurement by a Capacitive Voltage Probe in a Gas Insulated Switch (가스절연개폐기에서 용량성 전압프로브를 이용한 부분방전의 측정)

  • Kil, Gyung-Suk;Park, Dae-Won;Choi, Su-Yeon;Kim, Il-Kwon;Park, Chan-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.85-89
    • /
    • 2008
  • An objective of this paper is to develop a partial discharge (PD) measurement device for monitoring gas insulated switches installed in power distribution system. A capacitive voltage probe was studied and designed to detect PD pulse without an electrical connection. The PD measurement device consists of the capacitive voltage probe attached outside of a bushing, a coupling network which attenuates AC voltage by 270 dB, and a low noise amplifier with the gain of 40 dB in ranges of 500 kHz${\sim}$20 MHz. The sensitivity of the prototype device calculated by a calibrator was 1.98 m V /pc. An application experiment was carried out in a 25.8 kV gas insulated switch and the peak pulse of 76.7 pC was detected. From the experimental results, it is expected that the PD measurement device can be applied to online monitoring system of gas insulated switches.

Development of a Debris Flow Sensing Device and Real Time Warning System (토석류 감지장치 개발과 실시간 경보체계 구축 사례)

  • Kim, Kyung-Suk;Jang, Hyun-Ick;Chung, Sung-Yun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.273-280
    • /
    • 2008
  • Debris flow has been considered as one of the major natural hazards and possesses tens to hundreds times higher destructive potential than that of slope failure. In the past 5 years, its occurrence frequency was and is likely to increasing due to the global warming. Although various methods such as basin vegetation or structural dams can be implemented to counter measure the debris flow, these methods are not always the right answer to the problem when magnitude of debris flow is far bigger than could be defended. Land use regulations to avoid the hazard or early debris flow warning system to evacuate the expected inundated area can be more economical and practical actions for those cases. In this study, an early debris flow warning system composed of rainfall measuring device, debris flow sensing device and video camera is introduced. The system is designed to issue the warning when rainfall threshold is exceeded or debris flow is sensed by sensing device. Developed monitoring system can be used to cope promptly with the debris flow risk.

  • PDF

Construction of a Remote Monitoring System in Smart Dust Environment

  • Park, Joonsuu;Park, KeeHyun
    • Journal of Information Processing Systems
    • /
    • v.16 no.3
    • /
    • pp.733-741
    • /
    • 2020
  • A smart dust monitoring system is useful for obtaining information on rough terrain that is difficult for humans to access. One of ways to deploy sensors to gather information in smart dust environment is to use an aircraft in the Amazon rainforest to scatter an enormous amount of small and cheap sensors (or smart dust devices), or to use an unmanned spacecraft to throw the sensors on the moon's surface. However, scattering an enormous amount of smart dust devices creates the difficulty of managing such devices as they can be scattered into inaccessible areas, and also causes problems such as bottlenecks, device failure, and high/low density of devices. Of the various problems that may occur in the smart dust environment, this paper is focused on solving the bottleneck problem. To address this, we propose and construct a three-layered hierarchical smart dust monitoring system that includes relay dust devices (RDDs). An RDD is a smart dust device with relatively higher computing/communicating power than a normal smart dust device. RDDs play a crucial role in reducing traffic load for the system. To validate the proposed system, we use climate data obtained from authorized portals to compare the system with other systems (i.e., non-hierarchical system and simple hierarchical system). Through this comparison, we determined that the transmission processing time is reduced by 49%-50% compared to other systems, and the maximum number of connectable devices can be increased by 16-32 times without compromising the system's operations.

Design of Monitoring System for Integrated Management of On-site Wastewater Treatment Plants and Development of its Operation Program (소규모 현장 오수처리시설의 통합관리를 위한 모니터링 시스템 설계 및 운영 프로그램 개발)

  • Cho, Young-Hyun;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.137-140
    • /
    • 2002
  • The monitoring system for integrated management of on-site wastewater treatment plants(biofilter) was designed and its operation program was developed. In design process, the research on monitoring parameters which will be able to represent condition and operation of the pilot plants was accomplished, and these parameters came to reveal with ORP(Oxidation-Reduction Potential), water level, pump and power on/off. Proposed monitoring system is composed with measurement, control, communication and display device, and PCB(Prototype Circuit Boards) and microcontroller (PIC16F877) technique are applied to its design of control device for performing specific function. also, The operation program of PC setup is developed in order to provide a convenience to the manager.

  • PDF

Power Quality Monitoring Algorithm Using the Protective Relay (보호계전기를 이용한 전기 품질 감시 기법 연구)

  • Choi In. S.;Lee Kang. S.;Choi Myeon. S.;Lim Seong. I.;Lee Seung. J.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.11
    • /
    • pp.581-588
    • /
    • 2004
  • Power qualify monitoring system is devoted to more concern than before, because the innovation of industrial technology needs more accurate instruments and more advanced power quality. This paper was studied on using data of the protective relay by Power Quality Monitor. This paper was proposed the wave storage condition and monitoring clauses of the protective relay as a power quality monitoring device. The protective relay will have problem to save data for PQM analysis because the protective relay memory is limited. Therefore this paper was proposed new a data compression of data got from the protective relay. This method is wave compression comparison algorithm using the DFT. The compression rate is higher than any other established method. This method can be real time storage. This algorithm is verified using the comparison among other compression rate and proved by Real Time Digital Simulator (RTDS).

A Study on the Remote Operation and the Monitoring systems for Automatic Polishing Robot (자동 연마로봇의 원격 조작 및 모니터링 시스템 개발에 관한 연구)

  • 김병수;고석조;이민철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.122-122
    • /
    • 2000
  • Polishing work of a free-curved surface die demands simple and repetitive operations but requires a considerable amount of time for high precision. In out previous study, to reduce the polishing time and solve the problem of the shortage of skilled workers, the automatic polishing system was developed. However, in the polishing process of die, workers have to stay still in factory to monitor the polishing process for a long time in the poor environment. Therefore, this study proposes the remote operation and monitoring system of the automatic polishing robot. The developing system offer worker monitoring functions and teleoperating functions, as following: system state check, manual manipulation mode, automatic mode, manual teaching mode, automatic teaching mode, simulation by virtual manufacturing device. And automatic teaching system is developed to easily obtain a teaching data.

  • PDF

Real-time High Resolution PM Monitoring in Seoul (서울지역 미세먼지의 실시간 고해상도 모니터링 방안)

  • Kang, Doo Soo;Bong, Choon Keun;Kim, Dae Seong
    • Particle and aerosol research
    • /
    • v.15 no.2
    • /
    • pp.67-78
    • /
    • 2019
  • Since existing measurement sites are required to construct a high-cost PM measuring device and a measuring site of a large area, there is a limit to the construction of a high-resolution measurement network. Therefore, it is necessary to develop a low-cost, high-performance PM measuring device (as an alternative technology) that can increase the resolution of PM measurement, and it is necessary to establish a base to provide real-time PM information for whole people. Therefore, in this study, the alternative technique (light scattering method) for achieving the above object was examined, performance evaluation was carried out, and it was verified that the light scattering method was usable. Various PM measurement results were compared and analyzed to find PM monitoring points and resolutions we would like to propose.

Simulation Model Construction for Real-Time Monitoring of Traffic Signal Controller (교통신호제어기 실시간 감시를 위한 시뮬레이션 모델 구축)

  • Kim, Eun-Young;Chang, Dae-Soon;Jang, Jung-Sun;Park, Sang-Cheol
    • Journal of the Korean Institute of Plant Engineering
    • /
    • v.23 no.4
    • /
    • pp.21-27
    • /
    • 2018
  • This paper proposed the real-time monitoring methodology of a traffic signal controller. The proposed methodology is based on the simulation technology, and it is necessary to construct a simulation model imitating the behavior of a traffic signal controller. By executing the simulation model, we can obtain the 'nominal system trajectory' of the traffic signal controller. On the other hand, an IoT(Internet of Things)-based monitoring device is implemented in a traffic signal controller. Through the monitoring device, it is possible to obtain the 'actual system trajectory'. By comparing the nominal system trajectory and the actual system trajectory, we can estimate the degree of deterioration of a traffic signal controller.

Diagnosis and monitoring of inkjet operating conditions (잉크젯 작동 상태 진단 및 모니터링)

  • Kwon, Kye-Si;Kim, Byung-Hun;Kim, Sang-Il;Shin, Seung-Joo;Kim, Seong-Jin
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.455-460
    • /
    • 2007
  • A self-sensing circuit for piezo inkjet has been designed in order to monitor the operating condition during printing. In order to verify the circuit, both ink droplet images from strobe LED and vibration signals from the laser vibrometer were measured and compared with self-sensing signal. Experimental results show that self-sensing signal was effective in detecting the pressure wave change due to the bubble trapped in inkjet printhead.

  • PDF

Deterioration Monitoring Device by Unbalance Current Measurement of Rotating Machines (불평형전류 측정에 의한 회전기 열화감시장치)

  • Park, Chan-Yong;Park, Dae-Won;Rhyu, Keel-Soo;Kil, Gyung-Suk;Lee, Kang-Won
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2035-2039
    • /
    • 2008
  • This paper described an on-line condition monitoring device for rotating machines by measurement of unbalance current due to insulation deterioration. The device consists of a zero-phase current transformer (ZCT), a low-noise amplifying circuit, and a microprocessor unit. The prototype device measures current of $500\;{\mu}A\;{\sim}\;30\;mA$ in frequency ranges from 10 Hz to 3 kHz. An application experiment was carried out on 3-phase induction motors and we could measure current changes caused by a short-circuited turn.

  • PDF