Power qualify monitoring system is devoted to more concern than before, because the innovation of industrial technology needs more accurate instruments and more advanced power quality. This paper was studied on using data of the protective relay by Power Quality Monitor. This paper was proposed the wave storage condition and monitoring clauses of the protective relay as a power quality monitoring device. The protective relay will have problem to save data for PQM analysis because the protective relay memory is limited. Therefore this paper was proposed new a data compression of data got from the protective relay. This method is wave compression comparison algorithm using the DFT. The compression rate is higher than any other established method. This method can be real time storage. This algorithm is verified using the comparison among other compression rate and proved by Real Time Digital Simulator (RTDS).
Keywords
Power Quality; Data Compression; Protect Device;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 IEEE Standards Coordinating Committee, 'IEEE std 519-1992', IEEE Standards Board, April 1993
2 IEEE Standards Coordinating Committee, 'IEEE std 1159-1995', IEEE Standards Board, Nov 1995
3 황병준, 'PQM(Power Quality Monitoring) 시스템 運營技術의 適用', 전기학회월간지, 51권 8호, 26-32, 2002   과학기술학회마을
4 David G Hart, 'Tapping Protective Relays for Power Quality Information', IEEE Computer Applications in Power, Volume: 13 Issue: 1, 45 -49, Jan. 2000   DOI   ScienceOn
5 T.B.Littler,Dr.D.J.Morrow, 'Wavelets for the analysis and compression of power system disturbances', IEEE Transactions on Power Delivery, Vol. 14, No. 2, April 1999   DOI   ScienceOn
6 P.K.Dash, B.K.Panigrahi,D.K.Sahoo. G.Panda, 'Power Quality disturbance data compression, detection, and classification using integrated splin wavelet and S-transform', IEEE Transactions on Power Delivery, Vol. 18, No. 2, April 2003   DOI   ScienceOn
7 Shyh- Jier Huang, Ming-Jong Jou, 'Application of arithmetic coding for electric power disturbance data compression with wavelet packet enhancement', IEEE Transactions on Power Systems, 2004   DOI   ScienceOn
8 이은웅, '첨단 기술에 앞서야만 하는 전력품질', 전기학회월간지, 51권 10호 37-43, 2002   과학기술학회마을
9 압축기법연구 http://user.chollian.net/-iissi/목차.htm
10 배영준, 임성일, 최인선 '보호계전기를 이용한 전기품질감시 기법 연구', 2002년도 대한전기학회 전력기술부문회 추계학술대회논문집
11 임상호, 서영호, 김동욱 'DWT 기반의 영상 압축기 구현을 위한 데이터 형식', 2002년도 통신 및 신호처리소사이어티 추계학술발표논문집