Digital moire 형상측정 시스템의 보정에 관한 연구 (A Study on the Calibration of Shape Measurement System Using Digital moire)

  • 김도훈;유원재;박낙규;강영준
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 춘계학술대회 논문집
    • /
    • pp.255-259
    • /
    • 2003
  • Moire topography method isa well-known non-contacting 3-D measurement method as afast non-contact test for three-dimension shape measuring method. Recently, it's important to study the automatic three-dimension measurement by moire topography because it is frequently applied to the reverse engineering , the medical , the entertainment fields. Three-dimension measurement using projection of moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, the classical moire method is computerized-so called digital moire when a virtual grating pattern is projected on a surface, the captured image by the CCD camera has three-dimension information of the objects. The moire image can be obtained through a simple image processing and a reference grating pattern. and it provides similar results without physical grating pattern. digital projection moire topography turn out to be very effective for the three-dimension measurement of objects. Using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the four-three step algorithm method instead of the same step in the phase shifting of different pitch.

  • PDF

위상 이동 그림자 무아레 방법을 이용한 3차원 형상의 측정 (Measurement of three dimensional shapes using phase-shifting shadow moire method)

  • 강영준
    • 한국생산제조학회지
    • /
    • 제6권4호
    • /
    • pp.39-45
    • /
    • 1997
  • Shadow moire topography has been used as a noncontact method for measuring the 3-D shapes of objects. The moire fringes are results from the superposition of a master grating and its shadow projected on the surface of an object. But in case of the classical shadow moire method, in general, the resolution is a few tenths of millimeter. It is difficult to use a phase -shifting method in shadow moire because it is impossible to obtain uniform phase shifts on the whole field. But in this study , We introduce a phase-shifting method to improve the resolution of the classical shadow moire method. This method is based on the fact that if the depth of object is much less than the distance between the observer and the master grating, the phase shifts are almost uniform on the whole field area. Finally, we applied this new phase-shifting method to the measurement of the 3-D shape of a coin.

  • PDF

Digital moire 형상측정 시스템의 보정에 관한 연구 (A Study on the Calibration of Shape Measurement System Using Digital moire)

  • 유원재;김도훈;안재웅;강영준;노형민
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.199-202
    • /
    • 2002
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2$\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the flour-three step algorithm method than the same step in the phase shifting of different pitchs.

  • PDF

Digital Moire를 이용한 임의의 영사면에 대한 투영보정에 관한 연구 (A Study on Projective Calibration for Arbitrary Display Surface using Digital Moire Method.)

  • 유원재;김도훈;강영준;백성훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.292-295
    • /
    • 2003
  • Moire topography method is a well-known non-contacting 3-D measurement method. the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using digital projection moire topography is very attractive because of its high measuring speed and high sensitivity. In this study, digital two-wavelength phase shilling moire is applied to the entertainment fields. recently. as promoting the growth of the VR-Game, display devices which attract public attention such as HMD or Projector are being appeared in order to deliver effectively the absorption sense. this study realized the Auto-calibrating system for arbitrary display surface using digital moire method which satisfied the shape measurement of display surface and the request of FOV(Field of View) output. also when large screen wasn't prepared, this auto-calibrating system was applied to enjoy games or movies at home with a projector and walls

  • PDF

인체형상 측정을 위한 가상격자 영사식 무아레 방법에 관한 연구 (A Study on the Virtual Grating Projection Moire Topography for the Shape Measurement of Human Face)

  • 유원재;최정표;안중근;강영준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.49-52
    • /
    • 2001
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using projection moire topogrphy is very attractive because of it s high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection moire topography tested to measuring object with the $2\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the $2\pi$-ambiguity problem can be effectively overcome so as to treat large step discontinuities in measured objects.

  • PDF

고분해능 원자 현미경 스캐닝 무아레 기법을 이용한 미소 영역의 변형량 측정 (Measurement of Deformations in Micro-Area Using High Resolution AFM Scanning Moiré Technique)

  • 박진형;이순복
    • 대한기계학회논문집A
    • /
    • 제31권6호
    • /
    • pp.659-664
    • /
    • 2007
  • $Moire\'{e}$ interferometry is a useful technique to assess the reliability of electronic package because $Moire\'{e}$ interferometry can measure the whole-field and real-time deformations. The shear strain of a small crack site is important to the reliability assessment of electronic package. The optical limitation of $Moire\'{e}$ interferometry makes ambiguous the shear strain of a small area. An atomic force microscope (AFM) is used to measure the profile of a micro site. High resolution of AFM can apply to the $Moire\'{e}$ technique. AFM $Moire\'{e}$ technique is useful to measure the shear strain of a small area. In this research, the method to accurately measure the deformation of a small area by using AFM $Moire\'{e}$ is proposed. A phase-shifting method is applied to improve the resolution of AFM $Moire\'{e}$.

칼라 역 해프토닝에서 해프톤 패턴 간섭 분석에 의한 모아레 영역의 적응적 평활화 방법 (An Adaptive Smoothing for Moire Region using Analysis of Halftone Patterns Interference in Color Inverse Halftoning)

  • 한영미;김종민;김민환
    • 한국멀티미디어학회논문지
    • /
    • 제5권3호
    • /
    • pp.263-271
    • /
    • 2002
  • 본 논문에서는 해프톤 패턴 간섭 분석을 통해 모아레 패턴을 효과적으로 제거할 수 있는 새로운 모아레 영역 평활화 방법을 제시한다. 제안한 방법에서는 픽셀의 화소값을 이용하여 모아레 패턴의 세기를 결정하고 그 세기에 따라 평활화 정도를 적응적으로 조정해 주기 때문에, 모아레 패턴을 효과적으로 제거하면서 경계나 텍스쳐 같은 의미 있는 고주파 성분도 효과적으로 보존할 수 있다. 또한 기존의 블록기반 퓨리에 변환 방법과 달리, 미리 만들어진 테이블을 참조하는 과정만으로 모아레 패턴의 세기를 결정하기 때문에 연산 시간측면에서도 효율적이다. 제안한 방법은 칼라 인쇄물을 다루는 다양한 멀티미디어 분야에서 유용하게 활용될 수 있다.

  • PDF

근골격계 질환에 대한 경근무늬측정검사(모아레)의 한의약적 임상응용 고찰 (A Study on the Korean medicine Clinical Use of Moire topography in musculoskeletal diseases)

  • 류홍선;송애진;정명수
    • 대한예방한의학회지
    • /
    • 제20권1호
    • /
    • pp.75-87
    • /
    • 2016
  • Objectives : This study aims to classify and analyze literature related to moire topography, as a diagnostic device of Korean medicine, discuss research trends and major results, and demonstrate the value of moire topography. Methods : To investigate moire topography research trends, Korean keywords that signify 'moire' were searched in a Korean journal search engine. Initially, 2,988 papers were found in the research, and, after classifying them and removing those that are duplicate in other databases, only 37 papers were applicable for the literature review in this study. To analyze research trends, the 37 papers were analyzed based on the publication year, research field, journal, and research type, and, clinical articles were classified based on the diagnosis purpose, subject characteristics, diagnosis method, test method, and test result, for analysis. Results : Moire topography research in South Korea was first conducted in 1995 and most active in 2003, mostly in the field of Korean medicine. In the journal analysis, The Journal of Korea CHUNA Manual Medicine for Spine & Nerves published the highest number of papers, most of which were clinical articles and the rest were literature review. And, in the analysis of clinical papers, based on the diagnosis purpose, muscle somatotype measurement was most common, followed by diagnosis of scoliosis. In terms of subjects, most studies focused on elementary, middle, and high school students, and, in terms of the diagnosis method, other tests were used in most studies. The analysis of moire topography methods showed that most studies measured the shoulder, back, and hip, and the most common measurement method in the studies measured the difference in contour lines on the left and right by designating a central line of the body. In terms of the result, most moire topography brought about significant diagnosis results, and many studies demonstrated its use for musculoskeletal diseases in particular. Conclusions : Moire topography is believed to be highly significant for diagnosis and treatment of musculoskeletal diseases and further research will be needed to support it.

위상이동 그림자 무아레법을 이용한 3차원 물체의 형상측정 (Measurement of three dimensional object shape by means of the phase-shifting shadow moire)

  • 유원재;노경완;강영준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.96-100
    • /
    • 1997
  • The shadow moire is one of the optical techniques which is able to give contour lines of an object with respect to a master grating plane. The moire patterns are issued from the superposition of a master grating and its shadow projected on the surface of an object. In case of the classical shadow moire method, the sensitivity was a few tenths millimeters. generally, it is difficult to use a phase shift method in shadow moire because it is impossible to obtain uniform phase shifts on the whole field. But in this study we use the fact that if the depth of object is much less than the distance between the observer and the master grating, and the object is displaced perpendicularly to the grating plane, phase shifts are almost uniform. Finally we obtained a better resolution by using a phase shift procedure and applied the phase shifting shadow moire to three dimensional shape measurement.

  • PDF

인체흉상 합성을 위한 3차원 형상 측정에 관한 연구 (A study on 3-D shape measurement for the composition of human bust)

  • 안중근;강영준;최정표;유원재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.220-223
    • /
    • 1997
  • Moire topography method is a well-known non-contacting 3-D measuement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using projection moire topography is very attractive because of it's high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection moire topography tested to measuring object with the 2x-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the 2x-ambiguity problem can be effectively overcome so as to treat large step discontinuities in measured objects.

  • PDF