• Title/Summary/Keyword: Module degree

Search Result 235, Processing Time 0.027 seconds

Evaluation of Module Degree Considering Assembly and Disassembly (조립과 분리를 고려한 제품의 모듈정도 평가)

  • Mok, Hak-Soo;Yang, Tae-Il;Hwang, Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.8
    • /
    • pp.140-150
    • /
    • 2000
  • In this paper module of a product is determined by the characteristics of a product itself and process. To analyze the characteristics of the product information on subassemblies and parts can be obtained by analyzing the existing product. Based on the analysis of characteristics of product structure and function determination rules of a module degree could be proposed for assembly and disassembly process and product structure and function. By applying these rules of a module, module of a product is classified into full half and non-module depending on the module degree of a product. As a result of module degree analysis simpler assembly process and reduced structural interference can be realized. For the product function simpler updated and multi function can be also achieved.

  • PDF

Analysis of a Parallel 3 Degree-of-Freedom Spherical Module and its Implementation as a Force Reflecting Manual Controller (병렬형 3자유도 구형 모듈의 해석과 힘반영 원격조종기로의 구현)

  • 김희국;이병주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2501-2513
    • /
    • 1994
  • In this paper, a compact, light-weight, universal, spherical 3-degree-of-freedom, parallel-structured manual controller with high reflecting-force capability is implemented. First, the position analysis, kinematic modeling and analysis, force reflecting transformation, and applied force control schemes for a parallel structured 3 degree-of-freedom spherical system have been described. Then, a brief description of the system integration, its actual implementation hardware, and its preliminary analysis results are presented. The implemented parallel 3 degree-of-freedom spherical module is equipped with high gear-ratio reducers, and the friction due to the reducers is minimized by employing a force control algorithm, which results in a "power steering" effect for enhanced smoothness and transparency (for compactness and reduced weight).d weight).

Analysis of the Salt Separation and Concentration Using Counter-current Reverse Osmosis Spiral Wound Module (향류식 역삼투 나권형 모듈을 이용한 염분리농축 특성 해석)

  • 조한욱;민병렬;최광호
    • Membrane Journal
    • /
    • v.4 no.3
    • /
    • pp.142-151
    • /
    • 1994
  • Counter-current type reverse osmosis spiral wound module was manufactured for the separation and concentration of salf solution. The ratio of permeate volumetric flow rate vs. brine volumetric flow rate was effective parameter between rejection and degree of cocentration. The reflection coefficient was correspondent to the relation between rejection and degree of cocentration by Spiegler-Kedem model. Counter-current reverse osmosis process had more osmotic pressure drop effect and more degree of concentration than general reverse osmosis process. As a result of computer calculation, the extension of module length than module diameter was more effective for the increase of degree of concentration.

  • PDF

Analysis of Parallel Mechanisms with Forward Position Closed-Form Solution with Application to Hybrid Manipulator (정위치 해석해를 가지는 병렬 메카니즘에 관한 분석과 혼합구조 매니퓰레이터로의 활용)

  • 김희국;이병주
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.3
    • /
    • pp.324-337
    • /
    • 1999
  • In this work, a new 3-PSP type spatial 3-degree-of-freedom parallel mechanism is proposed. And a 6 DOF hybrid manipulator which consists of a 3-PPR type planar 3 DOF parallel mechanism and a new 3-PSP type spatial 3-degree-of-freedom parallel mechanism is proposed. Both 3 DOF mechanism modules have closed-form forward position solutions and particularly, 3-PSP spatial module has unique forward position solution. Firstly, the closed-form position analysis and first-order kinematic analysis for the proposed 3-PSP type module are carried out, and the first-order kinematic characteristics are examined via maximum singular value and the isotropic index of the mechanism. It is shown through these analyses that the mechanism has excellent isotrpic property throughout the workspace. Secondly, position and kinematic analysis of the 3-PPR planar module are briefly described. Thirdly, the forward position analysis for the 3-PPR 3-PSP type 6 degree-of-freedom hybrid mechanism consisting of a 3-PPR planar module and a 3-PSP spatial module is performed along with the analysis of the workspace size and first-order kinematic characteristics. The kinematic characteristics of the proposed hybrid manipulator are compared to those of geometrically similar Stewart manipulator.

  • PDF

Generation characteristics of transparent BIPV module according to temperature change (건물일체형 투명 모듈의 온도 변화에 따른 발전 특성)

  • Park, Kyung-Eun;Kang, Gi-Hwan;Kim, Hyun-Il;Yu, Gwon-Jong;Jang, Dae-Ho;Lee, Moon-Hee;Kim, Jun-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.210-211
    • /
    • 2007
  • Amid booming PV(photovoltaic) industry, BIPV(Building Integrated PV) is one of the best fascinating PV application technologies. To apply PV in building, variable factors should be reflected such as installation position, shading, temperature effect and so on. Especially a temperature should be considered, for it affects both electrical efficiency of PV module and heating and cooling load in building. Transparent PV modules were designed as finished material for spandrels are presented in this paper. The temperature variation of the modules with and without air gap and insulation were compared and analyzed. The results showed that the module with air gap and insulation has a much larger temperature variation than another transparent module. The temperature of the module reached by 55degree C under vertical irradiance of lower 500$W/m^2$. And the temperature difference between these modules was about 15degree C. To analyze the output performance of module according to temperature variation, separate module was manufactured and measured by sun-simulator. The results showed that 1 degree temperature rise reduced about 0.45% of output power.

  • PDF

A Study on Constructing Highly Adder/multiplier Systems over Galois Felds

  • Park, Chun-Myoung
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.318-321
    • /
    • 2000
  • This paper propose the method of constructing the highly efficiency adder and multiplier systems over finite fie2, degree of uk terms, therefore we decrease k into m-1 degree using irreducible primitive polynomial. We propose two method of control signal generation for perform above decrease process. One method is the combinational logic expression and the other method is universal signal generation. The proposed method of constructing the highly adder/multiplier systems is as following. First of all, we obtain algorithms for addition and multiplication arithmetic operation based on the mathematical properties over finite fields, next we construct basic cell of A-cell and M-cell using T-gate and modP cyclic gate. Finally we construct adder module and multiplier module over finite fields after synthesize ${\alpha}$$\^$k/ generation module and control signal CSt generation module with A-cell and M-cell. Then, we propose the future research and prospects.

  • PDF

An Arithmetic System over Finite Fields

  • Park, Chun-Myoung
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.4
    • /
    • pp.435-440
    • /
    • 2011
  • This paper propose the method of constructing the highly efficiency adder and multiplier systems over finite fields. The addition arithmetic operation over finite field is simple comparatively because that addition arithmetic operation is analyzed by each digit modP summation independently. But in case of multiplication arithmetic operation, we generate maximum k=2m-2 degree of ${\alpha}^k$ terms, therefore we decrease k into m-1 degree using irreducible primitive polynomial. We propose two method of control signal generation for the purpose of performing above decrease process. One method is the combinational logic expression and the other method is universal signal generation. The proposed method of constructing the highly adder/multiplier systems is as following. First of all, we obtain algorithms for addition and multiplication arithmetic operation based on the mathematical properties over finite fields, next we construct basic cell of A-cell and M-cell using T-gate and modP cyclic gate. Finally we construct adder module and multiplier module over finite fields after synthesizing ${\alpha}^k$ generation module and control signal CSt generation module with A-cell and M-cell. Next, we constructing the arithmetic operation unit over finite fields. Then, we propose the future research and prospects.

Kinematic Analysis of Fault-Tolerant 3 Degree-of-Feedom Spherical Modules (고장에 강인한 구형 3자유도 모듈에 관한 기구학적 해석)

  • 이병주;김희국
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.2846-2859
    • /
    • 1994
  • This work deals with kinematic analysis of fault-tolerant 3 degree-of-freedom spherical modules which have force redundancies in its parallel structure. The performance of a redundantly actuated four-legged module with no actuator failure, a single actuator failure, partial and half failure of dual actuator are compared to that of a three-legged module, in terms of maximum force transmission ratio, isotropic characteristics, and fault-tolerant capability. Additionally, a system with an excess number of small floating actuators is considered, and the contribution of these small actuators to the force transmission and fault-tolerant capability is evaluated. This study illustrates that the redundant actuation mode allows significant saving of input actuation effort, and also delivers a fault tolerance.

4 degrees of freedom control for attractive levitation module (자기부상 모듈의 4자유도 제어)

  • Kim, Kook-Hun;Kim, Choon-Kyung;Cho, Chang-Hee;Kim, Jong-Hoon;Park, Min-Kook
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.271-273
    • /
    • 1993
  • One maglev vehicle is composed of 6 or 8 modules. Each module is composed of 4 staggered magnets attached to an aluminum bogie. In the view point of levitation control except propulsion-by LIM. 5 is the maximum degree of freedom to be controlled. But rolling control of the vhhicle depends on the bogie structure. We describe just anti-roll type bogie structure and 4 degree of freedom control is sufficient for levitation quality improvement. Multivariable pole-placement concept is used for controller design. Control experiment is performed on a specially designed test module as well as actual bogie system.

  • PDF

A study on the performance of various BIPV modules applied in a real building demonstration (BIPV시스템의 건물적용 실증에 대한 구성요소별 발전성능 분석)

  • Lee, Sang-Moon;Huh, Jung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.2
    • /
    • pp.53-63
    • /
    • 2016
  • Building Integrated Photovoltaic (BIPV) is one of the best ways to generate electric power using the solar energy, which is clean and inexhaustible energy resources. The most of BIPV modules have the form of GtoG (Glass to Glass) photovoltaic in building applications. Degradation leading to failure in photovoltaic modules is very important factor in BIPV modules. This paper analyzed the performance of various BIPV modules through outdoor exposure tests. Performance of three BIPV modules(c-Si type, a-Si type and DSSC type) with three installation angles influenced by sun light, outdoor temperature, and wind velocity was monitored and analyzed. As a result, c-Si type BIPV module outperforms other BIPV modules(a-Si type). In terms of power efficiency of the module, the installed angle of $45^{\circ}$ is better than others(90 degree, 0 degree). In addition, more realistic data of various BIPV system performance could be available through the field test and integrated building test. In this study, relationship of the BIPV system is identified module's installation angle, power generation, architectural performance, etc.