• Title/Summary/Keyword: Module Equipment

Search Result 518, Processing Time 0.028 seconds

A Study of Inspection Module for Verifying Reliability on Railway Vehicle (철도차량 검측모듈의 신뢰성 검증 시험 연구)

  • Na, Kyung-min;Park, Young;Kwon, Sam-young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1155-1161
    • /
    • 2017
  • This study examines environmental performance of the arcing measurement module according to international standards. The module assesses the collected current performance using a computer system. The module is required to assess environmental impact resulting from electromagnetic waves, shock and temperature change during train operation. The test includes testing EMI/EMC, vibration, shock and temperature cycling for interface between trains and the arcing measurement module. The module test items were determined in compliance with the standards suggested by the International Electrotechnical Commission (IEC) and Europaische Norm (EN). This study describes the method of test, test equipment operation and how to choose relevant performance standards. The analysis and test results of environmental performance for the module based on computer system are described in this study.

A Plan for Establishing IOT-based Building Maintenance Platform (S-LCC): Focusing a Concept Model on the Function Configuration and Practical Use of Measurement Data (IOT 기반 건축물 유지관리 플랫폼 구축(S-LCC) 방안 : 기능구성과 계측 데이터 활용을 위한 개념 모델을 중심으로)

  • Park, Tae-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.611-618
    • /
    • 2020
  • The reliability of the results of LCC analysis is determined by accurate analytical procedures and energy data from which the uncertainty is removed. Until now, systems that can automatically measure these energy data and produce databases have not been commercialized. Therefore this paper proposes a concept model of an S-LCC platform that can automatically collect and analyze electric energy consumption data of equipment systems using the IOT, which is the core tool in the Fourth Industrial Revolution and operates the equipment system efficiently using the analyzed results. The proposed concept model was developed by the convergence of existing BLCS and IOT and was comprised of five modules: Facility Control Module, LCC Analysis Module, Energy Consumption Control Module, Efficiency Analysis Module, and Maintenance Standard Reestablishment Module. Using the results of LCC analysis deduced from this system, the deterioration condition of an equipment system can be identified in real-time. The results can be used as the baseline data to re-establish standards for the maintenance factor, replacement frequency, and lifetime of existing equipment, and establish new maintenance standards for new equipment. If the S-LCC platform is established, it would increase the reliability of LCC analysis, reduce the labor force for entering data and improve accuracy, and would also change disregarded data into big data with high potential.

Time Series Analysis of Crystalline Silicon Photovoltaic Module Certification Results (결정질 실리콘 태양광발전모듈 인증 실적의 시계열 분석)

  • Han, Yun-Cheol;Kim, Ik-Pyo;Kang, Kyu-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.3
    • /
    • pp.33-45
    • /
    • 2017
  • Crystalline silicon photovoltaic module certification began in 2007. "Renewable Energy Equipment Certification Scheme" was implemented until July 28, 2015. Then, the scheme was changed to "KS Certification Scheme" since July 29, 2015. A total of 2,331 models have been certified by 2016. The proportion of multi crystalline modules in certified products is higher than that of mono crystalline modules, and Korean modules account for 78% of the total certification modules. Chinese solar cells account for the highest percentage of 40% of the total modules and 62.4% of modules certified in 2016 use Chinese solar cells. With the development of technology, module power is continuously increasing, and efficiency is also rising. The average efficiency of mono crystalline module is 0.74% higher than the average of multi crystalline module. As a result of comparing domestic module with Chinese module, the highest efficiency of mono crystalline module and multi crystalline module and the average efficiency of mono crystalline module are higher than those of Chinese module, but the average efficiency of multi crystalline module is similar to that of Chinese module.

Development of the Interface Module for an Effective Application of a Digital Mockup

  • Song, Tai-Gil;Kim, Sung-Hyun;Lim, Gwang-Mook;Yoon, Ji-Sup;Lee, Sang-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2407-2409
    • /
    • 2005
  • As the cumulative amount of spent fuel increases, the reliable and effective management of the spent fuel has become a world-wide mission. For this mission, KAERI is developing the Advanced Spent Fuel Conditioning Process (ACP) as a pre-disposal treatment process for spent fuel. Conventional approach to the development of the process and the remote operation technology is to fabricate the process equipment on the same scale as the real environment and demonstrate the remote handling operation using simulated fuel called a mock-up test. But this mock-up test is expensive and time consuming, since the design may need to be modified and the equipment fabricated again to account for the problems found during a testing. To deal with this problem, we developed a digital mockup for the ACP. Also, for an effective utilization of the digital mockup, we developed user interface modules such as the data acquisition and display module and the external input device interface module. The result of this implementation shows that a continuous motion of the manipulator using the external device interface can be represented easily and the information display screens responded well to the simulation situation.

  • PDF

A Development on Universal RF based Module for Wireless Network (계측 시스템의 무선통신을 위한 RF모듈 개발)

  • Park, Suk-Hyun;Shim, Woo-Hyuk;Seo, Young-Jo;Kim, Beung-Jin;Jeon, Hee-Jong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3064-3066
    • /
    • 1999
  • The existing equipment with wire communication can expect the stability of data transmission. However, according to increasing a number of DTE (Data Terminal Equipment), wiring work becomes a heavy burden. Restriction to application about portable DTE and the lack of flexibility are another drawback of wire communication. This paper presents the design and implementation of a RF (Radio Frequency) based wireless communication system. The RF based module is designed to the multi communication between DTEs. The RF based module consists of RF circuit and microprocessor. The main properties of RF circuit are maximum 5Kbps transmission rate, maximum 90m transmission distance and 433MHz frequency band. The microprocessor rearrange the data into AHDLC(Advanced High level Data Link Control) format and then instructs RF circuits to transmit/receive the data. The RF module have a wide application field such as fire/security alarm, remote control/measurement etc..

  • PDF

KS Standard for Logistics Facilities and Equipments (물류시설 및 기기의 KS 표준규격)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2007.04a
    • /
    • pp.449-456
    • /
    • 2007
  • This paper presents system of physical distribution module, and classification of logistics equipments. This study also introduces equipment standards of logistics facilities, and environmental rules for distribution center. Moreover, this paper shows safety standard and marking for logistics equipments and tools.

  • PDF

Throughput Analysis of the Twin Chamber Platform Equipment according to the Load-lock Configuration (쌍 체임버 기반 장비의 로드락 구성에 따른 생산성 분석)

  • Hong, Joo-Pyo;Lee, Ki-Seok
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.2
    • /
    • pp.39-43
    • /
    • 2008
  • Productivity is one of the performance indices of the semiconductor equipment in manufacturing viewpoint. Among many ways tried and adopted for improvement of the productivity of the FAB equipment, variation of equipment configuration was considered and its effect on the throughput was analyzed. Parallel machine cycle charts that were generated based on the equipment log were used in the analysis. Efficiency of the equipment due to change of the structure and the probability of the usage in the manufacturing process were examined. The results showed that the modification of the control algorithm in the equipment and the redistribution of the process time for each process and transfer module along to the change in the structure enhance the throughput of the equipment.

  • PDF

A study on the improvement of antenna switching module structure of ground based ES equipment (지상용 ES장비의 안테나전환기 구조 개선에 관한 연구)

  • Kim, Seung-Woo;Lee, Kang-Ho;Chin, Hui-cheol;Choi, Jae-In
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.151-159
    • /
    • 2017
  • The aspect of modern warfare is gradually changing to a network of warfare, and its central information electronic warfare is evolving every day. Recently, domestic equipment of electronic warfare, which have succeeded in domestic localization, are strongly influenced by the nature of the environment. Therefore, the structural reliability of the antenna switching module that connects the mast and antenna of the ES equipment is the most important. This study proposed a structure that has an improved structure of antenna switching module by currently analyzing the structure of the antenna switching module and the environmental influence. By modifying the structure of the antenna switching module welding method and part of the reinforcement block, the structure was improved and the validity of the improved antenna switching module was simulated using a load test. The simulation showed that the safety factors of antenna switching module welding point and reinforced block part was enhanced 5.3 and 1.5 times compared to the existing values. These values were verified by load (181kg) test results, which was each 3.7Mpa and 64.4Mpa. The load test results were similar to the simulation results and load supporting capacity of the proposed antenna switching module was enhanced.