• Title/Summary/Keyword: Modified XP

Search Result 21, Processing Time 0.029 seconds

The Comparison of Property and Visible Light Activity between Bulk and Surface Doped N-TiO2 Prepared by Sol-gel and N2-plasma Treatment

  • Hu, Shaozheng;Li, Fayun;Fan, Zhiping
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.199-203
    • /
    • 2012
  • A modified sol-gel method and $N_2$-plasma treatment were used to prepare bulk and surface doped N-$TiO_2$, respectively. XRD, TEM, UV-vis spectroscopy, $N_2$ adsorption, Elemental Analyzer, Photoluminescence, and XP spectra were used to characterize the prepared $TiO_2$ samples. The N doping did not change the phase composition and particle sizes of $TiO_2$ samples, but increased the visible light absorption. The photocatalytic activities were tested in the degradation of an aqueous solution of a reactive dyestuff, methylene blue, under visible light. The photocatalytic activity of surface doped N-$TiO_2$ prepared by $N_2$-plasma was much higher than that of bulk doped N-$TiO_2$ prepared by sol-gel method. The possible mechanism for the photocatalysis was proposed.

Surface Composition Change of UV/Ozone Modified Polypropylene (UV/오존에 의해 개질된 폴리프로필렌의 표면 조성 변화)

  • Kim, J.I.;Ryu, S.H.
    • Elastomers and Composites
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2002
  • Polypropylene is oxidized with UV/ozone as a function of UV treatment time and ozone flow rate and its surface characteristics are investigated using contart angle measurements and XPS. The aging behavior of oxidized surface is investigated under air, water and ethylene glycol as the aging media. Adhesion strength is also investigated using a lap shear test. Polar surface energy increases with increasing UV/ozone treatment time as well as ozone flow rate. No polar surface energy change is observed under water aging, while under air aging it decreases significantly within 2-3 days and reaches the close value as that of the untreated PP. Adhesion strength increases with increasing UV/ozone treatment time as well as ozone flow rate.

The Cracking Reaction of Vacuum Gas Oil on Mordenite Modified by HF and Steaming (불화수소산과 스팀처리한 모더나이트상에서 진공가스유의 분해반응)

  • Lee, Kyong-Hwan;Ha, Baik-Hyon
    • Applied Chemistry for Engineering
    • /
    • v.7 no.5
    • /
    • pp.925-937
    • /
    • 1996
  • Three types of mordenites treated by steaming($SM_{6.5}$), HF solution for $SM_{6.5}(FM_a)$ and HF solutlon+steaming for $SM_{6.5}(FM_b)$ were prepared and used as cracking catalysts of vacuum gas oil. These samples were analysed by XRF and XPS for average and surface Si/Al atomic ratio, XRD for unit cell constants, nitrogen adsorption/desorption for porosity, pyridine-IR for acidic properties. In comparison with three type samples, $SM_{6.5}$ had a lot of acid amount and showed micropore volume mostly(>85% to total volume). Dealuminated $FM_a$, compared with $SM_{6.5}$, was decreased a little in acid amount and improved for porosity. Also, $FM_b$ was decreased further in acid amount and developed in mesopore dramatically. The catalytic activity and the yield of gasoline, kerosine+diesel and branched aromatic over the modified mordenites which have developed mesopore were improved. This is due to limited access of diffusion of large molecules within pore of the modified mordenites.

  • PDF

Influence of Ozone Treatment on the Surface Characteristics of Montmorillonite and the Thermal Stability of Montmorillonite/polypropylene Nanocomposites (오존처리가 몬모릴로나이트의 표면특성 및 몬모릴로나이트/폴리프로필렌 나노복합재료의 열안정성에 미치는 영향)

  • Jin Sung-Yeol;Lee Jae-Rock;Park Soo-Jin
    • Composites Research
    • /
    • v.18 no.1
    • /
    • pp.23-29
    • /
    • 2005
  • In this work, the effect of ozone treatment of montmorillonite (MMT) on the surface characteristics of montmorillonite and the thermal stability of MMT/polypropylene (PP) nanocomposites was investigated. The surface properties of MMT were determined by X-ray diffraction (XRD), Fourier transform infrared (FT-IR), and X-ray photoelectron spectroscopy (XPS). Also, the thermal stability of nanocomposites was investigated in thermogravimetric analysis (TGA). As a result, it was found that the silicate interlayers of the organically modified MMT (D-MMT) were increased by about 11${\AA}$, as compared with the MMT. Also, FT-IR showed that a new peaks at $2800\~2900\;cm^{-1}$ appeared due to the $CH_2$ mode in the D-MMT The ozone treatment of the MMT led to an increase of SiO or $SiO_2$ groups on MMT surfaces, resulting in increasing the oxygen-containing functional groups on MMT. The ozonized MMT had higher thermal stability than that of untreated nanocomposites. This was due to the improvement of interfacial bonding strengths, resulting from the acid-base interfacial interactions between PP and MMT.

Surface Analysis of Modified Polymer Samples by X-Ray Photoelectron Spectroscopy and Rutherford Backscattering Spectroscopy (X-선 광전자 분광법 및 라더포드 후방산란법에 의한 개질된 고분자 시료의 표면분석)

  • Park, Sung-Woo;Kim, Dong-Hwan;Kim, Young-Man;Park, Byung-Sun;Han, Wan-Soo;Suh, Bae-Suk
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.301-313
    • /
    • 1994
  • X-Ray Photoelectron Spectroscopy(XPS) and Rutherford Backscattering Spectroscopy(RBS) are used for the analysis of additives, examination of chemical structure and determination of identity with qualitative and quantitative analysis of surface elements, binding energy level and depth profiling in the surface. We analyzed surface of polyethylene, acrylonitrile butadien rubber, polypropylene, glass, fiber and paper treated with $XeF_2$ or C-F plasma by XPS and RBS. It was found that fluoro element was penetrated to sample surface and the distribution of surface elements are different than untreated samples.

  • PDF

Hermetic Characteristics of Negative PR (Negative PR의 기밀 특성)

  • Choi, Eui-Jung;Sun, Yong-Bin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.2 s.15
    • /
    • pp.33-36
    • /
    • 2006
  • Many issues arose to use the Pb-free solder as adhesive materials in MEMS ICs and packaging. Then this study for easy and simple sealing method using adhesive materials was carried out to maintain hermetic characteristic in MEMS Package. In this study, Hermetic characteristic using negative PR (XP SU-8 3050 NO-2) as adhesive at the interface of Si test coupon/glass substrate and Si test coupon/LTCC substrate was examined. For experiment, the dispenser pressure was 4 MPa and the $200\;{\mu}m{\Phi}$ syringe nozzle was used. 3.0 mm/sec as speed of dispensing and 0.13 mm as the gap between Si test coupon and nozzle was selected to machine condition. 1 min at $65^{\circ}C$ and 15 min at $95^{\circ}C$ as Soft bake, $200\;mj/cm^2$ expose in 365 nm wavelength as UV expose, 1 min at $65^{\circ}C$ and 6 min at $95^{\circ}C$ as Post expose bake, 60 min at $150^{\circ}C$ as hard bake were selected to activation condition of negative PR. Hermetic sealing was achieved at the Si test coupon/ glass substrate and Si test coupon/LTCC substrate. The leak rate of Si test coupon/glass substrate was $5.9{\times}10^{-8}mbar-l/sec$, and there was no effect by adhesive method. The leak rate of Si test coupon/LTCC substrate was $4.9{\times}10^{-8}mbar-l/sec$, and there was no effect by dispensing cycle. Better leak rate value could be achieved to use modified substrate which prevent PR flow, to increase UV expose energy and to use system that controls gap automatically with vision.

  • PDF

Three-dimensional Kinematic Analysis of the Yurchenko Layout with 360-degree Twist in Female Vaults: Deterministic Model and Judges' Scores

  • Park, Cheol-Hee;Kim, Young-Kwan
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.1
    • /
    • pp.9-18
    • /
    • 2017
  • Objective: The purpose of this study was to identify kinematic variables that govern successful performance and judges' scores and to establish correlative relationships among those of Yurchenko layout with a full twist in female vaults. Method: Four video cameras with sampling rate of 60 Hz collected 32 motion data of Yurchenko vaults from twenty-two female participants (age: $18.6{\pm}3.6years$, height: $153.0{\pm}6.5cm$, mass: $44.7{\pm}7.3kg$) during national competition. Posting processing and calculations of kinematic variables were performed in Kwon 3D XP and $Matlab^{(R)}$ programs. Correlation and regression analyses were applied to find the relationships between the obtained scores and kinematic variables. Deterministic model (Hay & Reid, 1988) was used to investigate the strength of correlative relationships among kinematic variables. Results: The obtained scores from the judges' decision were mainly affected by post-flight peak height, horse contact time, knee angle at landing, and horse takeoff angle. Strong blocking during horse contact was required to get successful performance and obtain high scores. Modified deterministic model showed that round-off entrance and takeoff angles and resultant velocity of the center of mass (CM) during the roundoff phase were the starting variables affecting performance in the following kinematics. Knee angle at landing, a highly influential variable on the obtained point, was only determined by judges' decision without significant correlative relationship with previous kinematic variables. Conclusion: The obtained scores highly depended on kinematic variables of post-flight and horse contact phases that were affected by those from the previous phases including round-off postures and resultant velocity of the body center of mass.

Improvement of Fouling Resistance with Reverse Osmosis Membrane Using Multi-layer Silane-Epoxy Surface Modification (실란-에폭시 다층 표면개질을 통한 역삼투막의 내오염성 향상)

  • Kwon, Sei;Lee, Yong Taek
    • Membrane Journal
    • /
    • v.25 no.4
    • /
    • pp.332-342
    • /
    • 2015
  • In this study, to solve the major problem of reverse osmosis (RO) membrane, surface of reverse osmosis membrane was modified by silane-epoxy multi layer. Octyltrimethoxysilane (OcTES) was polymerized to membrane surface via cross-linking by Sol-gel method. n = 8 alkylgroup of OcTES formed the branch structure by self assembly. And for improve fouling resistance of RO membrane, Ether group of ethylene glycol diglycidyl ether (EGDE) was given to improve hydrophilicity of RO membrane surface by ring-opening. To analyze structure of RO membrane surface with FE-TEM and AFM. Membrane surface of the ridge and valley structure and the bridge structure was confirmed due to the multi-layer surface modification of OcTES and EGDE. And through the increase of the roughness, the branch structure was formed well on membrane surface. Through the XPS analysis was identified chemical structure of membrane surface. And confirmed that the hydrophilic surface modification is given to the surface of the film through a Contact angle analysis. In optimization of EGDE surface modification condition, was suitable 0.5 wt% EGDE concentraion and $70^{\circ}C$ ring-opening temperature. In result of fouling resistance test and MFI is SUL-H10, $PA-OcTES_{1.0}$, $PA-OcTES_{1.0}-EGDE_{0.5}$ 68.7, 60.4, 5.4 ($10E-8hr/mL^2$), multi-layer surface modified membrane improved fouling resistance.

CD34 Monoclonal Antibody-Immobilization on Polyurethane Surface by Poly(PEGA-co-BMA) Coating (PEGA/BMA 공중합체의 코팅을 통해 CD34 단일클론항체가 고정화된 폴리우레탄 표면)

  • Joung, Yoon-Ki;Hwang, In-Kyu;Park, Ki-Dong
    • Polymer(Korea)
    • /
    • v.33 no.6
    • /
    • pp.602-607
    • /
    • 2009
  • A polyurethane (PU) surface enabling in vivo endothelialization via endothelial progenitor cell (EPC) capture was prepared for cardiovascular applications. To introduce CD34 monoclonal antibody (mAb) inducing EPC adhesion onto a surface, poly (poly (ethylene glycol) acrylate-co-butyl methacrylate) and poly (PEGA-co-BMA) were synthesized and then coated on a surface of PU, followed by immobilizing CD34 mAb. $^1H$-NMR analysis demonstrated that poly(PEGA-co-BMA) copolymers with a desired composition were synthesized. Poly(PEGA-co-BMA)-coated PU was much more effective for the immobilization of CD34 mAb, comparing with PEG-grafted PU prepared in our previous study, as demonstrated by that surface density and activity of CD34 mAb increased over 32 times. Physico-chemical properties of modified PU surfaces were characterized by X-ray photoelectron spectroscopy (XPS), water contact angle, and atomic force microscopy (AFM). The results demonstrated that the poly(PEGA-co-BMA) coating was effective for CD34 mAb immobilization and feasible for applying to cardiovascular biomaterials.

KrF 엑시머 레이저를 이용한 웨이퍼 스텝퍼의 제작 및 성능분석

  • 이종현;최부연;김도훈;장원익;이용일;이진효
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.15-21
    • /
    • 1993
  • This paper describes the design and development of a KrF excimer laser stepper and discusses the detailed system parameters and characterization data obtained from the performance test. We have developed a deep UV step-and-repeat system, operating at 248 nm, by retrofitting a commercial modules such as KrF excimer laser, precision wafer stage and fused silica illumination and 5X projection optics of numerical aperture 0.42. What we have developed, to the basic structure, are wafer alignment optics, reticle alignment system, autofocusing/leveling mechanisms and environment chamber. Finally, all these subsystem were integrated under the control of microprocessor-based controllers and computer. The wafer alignment system comprises the OFF-AXIS and the TTL alignment. The OFF-AXIS alignment system was realized with two kinds of optics. One is the magnification system with the image processing technique and the other is He-Ne laser diffraction type system using the alignment grating on the wafer. 'The TTL alignment system employs a dual beam inteferometric method, which takes advantages of higher diffraction efficiency compared with other TTL type alignment systems. As the results, alignment accuracy for OFF-AXIS and TTL alignment system were obtained within 0.1 $\mu\textrm{m}$/ 3 $\sigma$ for the various substrate on the wafers. The wafer focusing and leveling system is modified version of the conventional systems using position sensitive detectors (PSD). This type of detection method showed focusing and leveling accuracies of about $\pm$ 0.1 $\mu\textrm{m}$ and $\pm$ 0.5 arcsec, respectively. From the CD measurement, we obtained 0.4 $\mu\textrm{m}$ resolution features over the full field with routine use, and 0.3 $\mu\textrm{m}$ resolution was attainable under more strict conditions.

  • PDF