• Title/Summary/Keyword: Mode-5

Search Result 6,119, Processing Time 0.03 seconds

Mixed Mode Interlaminar Fracture Behaviors of Carbon Fabric/Epoxy Composites (탄소섬유직물/에폭시 복합재의 혼합모우드 층간파괴 거동)

  • Yoon, Sung-Ho;Heo, Kwang-Soo;Oh, Jin-Oh
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.1
    • /
    • pp.58-65
    • /
    • 2007
  • Mixed mode interlaminar fracture behaviors of carbon fabric/epoxy composites were investigated through MMF (Mixed Mode Flexural) test by varying mixed mode ratio ranging from 20% to 90%. Mixed mode interlaminar fracture criteria based on NL point and 5% offset point were also suggested in order to predict mixed mode interlaminar fracture behaviors. Fracture surfaces and crack propagating behaviors were examined through a travelling scope and a scanning electron microscope. According to the results, mixed mode interlaminar fracture behaviors can be predicted by mixed mode interlaminar fracture criterion with m=1.5 and n=0.5 on the basis of NL point or mixed mode interlaminar fracture criterion with m=2 and n=3 on the basis of 5% offset point. Fracture surfaces and crack propagating behaviors are sensitive to mixed mode ratios. MMF test can be successfully applicable in evaluating mixed mode interlaminar fracture toughness of carbon fabric/epoxy composites.

A High-Efficiency, Robust Temperature/voltage Variation, Triple-mode DC-DC Converter (고효율, Temperature/voltage 변화에 둔감한 Triple-mode CMOS DC-DC Converter)

  • Lim, Ji-Hoon;Ha, Jong-Chan;Kim, Sang-Kook;Wee, Jae-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.6
    • /
    • pp.1-9
    • /
    • 2008
  • This paper suggests the triple-mode CMOS DC-DC converter that has temperature/voltage variation compensation techniques. The proposed triple-mode CMOS DC-DC converter is used to generate constant or variable voltages of 0.6-2.2V within battery source range of 3.3-5.5V. Also, it supports triple modes, which include Pulse Width Modulator (PWM) mode, Pulse Frequency Modulator (PFM) mode and Low Drop-Out (LDO) mode. Moreover, it uses 1MHz low-power CMOS ring oscillator that will compensate malfunction of chip in temperature/voltage variation condition. The proposed triple-mode CMOS DC-DC converter, which generates output voltages of 0.6-2.2V with an input voltage sources of 3.3-5.5V, exhibits the maximum output ripple voltage of below 10mV at PWM mode, 15mV at PFM mode and 4mV at LDO mode. And the proposed converter has maximum efficiency of 93% at PWM mode. Even at $-25{\sim}80^{\circ}C$ temperature variations, it has kept the output voltage level within 0.8% at PWM/PFM/LDO modes. For the verification of proposed triple-mode CMOS DC-DC converter, the simulations are carried out with $0.35{\mu}m$ CMOS technology and chip test is carried out.

2-state 5-pole bandpass filter consisted of dual and tripe-mode cavity resonator (이중 및 삼중모드 공동 공진기로 구성된 2단 5-Pole 대역통과 필터)

  • 김상철;홍의석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.6
    • /
    • pp.1251-1258
    • /
    • 1997
  • Generally, it is very important to study selective coupling between cavities of the filter structure using multimode cavity resonator. In this paper, we have manufactured 5-pole bandpass filter(BPF) using dual and triple-mode cavity resonator. To do so, we have derived the formulas for coupling coefficient about coupling between TE-modes from TM/TE-mode's tangential and lognitudinal field intensities each other. To implement the Chebyshev response, the intercabity slot combining dual-mode and triple-mode is designed to couple one H-field of TE-mode parallel to slot plate. In this paper, specially it is derived the formulas for T $E_{11p}$-mode from TE-modes, and determined after obtaining location and size of intercabity slot from the equation. In this ppaer, based on this result, we designed and implmented teh bandpass filter operated at the center frequency of 14.5GHz with a Chebyshev response. For the manufactured cavity filter, dual-mode and triple-mode cavity are resonted by two orthogonal T $E_{113}$-modes, and by two orthogonal T $E_{113}$-modes and one T $M_{012}$-mode, respecitively. The 2-stage 5-pole BPF proposed in this paper has the insertion loss of -2.32dB, the reflection loss of -15dB in the passband, and the out-or-rejection of -67dB.

  • PDF

Mark XIIA(Mode 5) IFF System Integration and Certification Test for Surface to Air Missile System (유도무기체계 모드 5 피아식별 체계통합 및 인증시험)

  • Kim, Woo-Hyun;Jung, Se-Young;Lee, Yun-Soo;Chang, Se-Myong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.160-168
    • /
    • 2022
  • The new IFF mode, Mode-5 replacing Mode-4, has already been established by the US DoD for its allies and NATO forces. A IFF retrofit program for replacing the Mark XII Mode-4 with Mark XIIA Mode-5 is in progress in order to overcome the security limitations of the former in R.O.K. IFF certification test for the new mode, Mode-5, has been performed on medium range surface to air missile platform of the Korean armed forces for the first time in R.O.K and this is regarded as a monumental event in Korean defense industry. The present paper is a discussion on the procedures applied to the IFF system retrofit and integration, lessons learned from AIMS test with the US AIMS PO as observer. The minimum modification from the existing Mark XII Mode-4 to Mark XIIA Mode-5 and evolutional adaption from previous design including interoperability are required for the system retrofit. Letter of Certification was received from the US AIMS PO after the tests. The authors propose that the lessons learned and know-how acquired during the tests are managed by the R.O.K Government as the standard structure of a database. It is expected that the use of the database will reduce the developmental difficulties and risk, also increase efficiency in future developments and other projects.

A Effect of Photo Dynamic Therapy for LAZER Wave Mode (방사모드에 따른 레이저 치료 효과)

  • Choi, Deog Su;Lim, Hyun Soo;Lee, Byung Koo;Kenar, Necla
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.4
    • /
    • pp.134-139
    • /
    • 2016
  • US Food and Drug Administration (FDA) approved as a innovative cure for cancer, 1996. The effect is death of cancer cells through necrosis, apoptosis. Mainly the Continuous Wave mode (CW) use for PDT Laser. It sting, the question including itch, and etc. Reportedly, the increase of temperature with the perforated edema, ulcer, necrosis. The Thermal relaxation time and Oxygen recovery time is necessary. To give a normal oxygen recovery time of the cell, used Pulse mode. Progress, it was Burst Pulse mode when easing the thermal wake, the simplicity was secured, the PDT effect is good. Excepted in control group CW, Pulse, Burst pulse mode were incubated with various concentrations of 5-aminolevulinic acid hydrochloride (ALA-5). The tumor size reduction CW mode (44%), Pulse mode (48%), Burst pulse mode (53%) at 4 week after PDT with 0.3, 0.3, 0.3 mg/ml of ALA-5. After 4 hours, investigation of 100, 100, $100J/cm^2$ laser irradiation. The pulse mode was superior in expirimental data analysis. And it was the Burst pulse mode edge head of a family effect.

The Scanning Electron Microscopic study on the effect during subgingival calculus removal using Nd:YAG laser (치은연하치석제거술시 Nd : YAG 레이저를 이용한 효과에 관한 주사전자현미경적 연구)

  • Jeon, Yong-Seon;Choi, Byung-Son;Lee, Seok-Cho;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.2
    • /
    • pp.411-424
    • /
    • 1997
  • The purpose of this study was to evaluate in vitro the effects during subgingival calculus removal using Nd:YAG laser. The study group was consisted of 30 teeth with advanced periodontal disease extracted before the start of periodontal therapy. The specimens were divided into 8 different groups : 1) untreated control 2) scaling and root planing only 3) laser treated using 150mJ/pulse, 1sec, 5sec, contact mode 4) laser treated using 200mJ/pulse, 5sec, contact mode 5) laser treated using 150mJ/pulse, 1sec, non-contact mode 6) laser treated using 200mJ/pulse, 5sec, non-contact mode 7) laser treated using l5OmJ/pulse, 1sec, contact mode with water irrigation 8) laser treated using 200mJ/pulse, 5sec, contact mode with water irrigation. All specimens were prepared for evaluation by scanning electron microscopy(SEM). Specimens from Group 2 exhibited a smear layer of scale like texture with parallel instrument tracks resulting from curet use. Specimens treated by contact mode, Group 3 and 4 featured surface changes not observed· in controls such as charring, randomly distributed pitting and crater formation, and melting down of the tooth material and calculus. Specimens treated by noncontact mode, Group 5 and 6 featured similar surface changes observed in contact mode. However, the differences between contact and non-contact groups not significant. Specimens treated by contact mode with water irrigation, Group 7 and 8 featured slight surface change compared to other groups. The results suggested that Nd: YAG laser did not completely remove the subgingival calculus but was possible the application as adjunctive method.

  • PDF

A Design of Wide Input Range Multi-mode Rectifier for Wireless Power Transfer System (넓은 입력 범위를 갖는 무선 전력 전송용 다중 모드 정류기 설계)

  • Choi, Young-Su;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.4
    • /
    • pp.34-42
    • /
    • 2012
  • In this paper, a wide-input range CMOS multi-mode rectifier for wireless power transfer system is presented. The output voltage of multi-mode rectifier is sensed by comparator and switches are controlled based on it. The mode of multi-mode rectifier is automatically selected by the switches among full-wave rectifier, 1-stage voltage multiplier and 2-stage voltage multiplier. In full-wave rectifier mode, the rectified output DC voltage ranges from 9 V to 19 V for a input AC voltage from 10 V to 20 V. However, the input-range of the multi-mode rectifier is more improved than that of the conventional full-wave rectifier by 5V, so the rectified output DC voltage ranges from 7.5 V to 19 V for a input AC voltage from 5 V to 20 V. The power conversion efficiency of the multi-mode rectifier is 94 % in full-wave rectifier mode. The proposed multi-mode rectifier is fabricated in a $0.35{\mu}m$ CMOS process with an active area of $2500{\mu}m{\times}1750{\mu}m$.

A Design of IFF Mode 5 Interworking Gateway Prototype (IFF Mode 5 연동 게이트웨이 프로토타입 설계)

  • Nam, Sung-woo;Kim, Jun-young;Oh, Sun-taek
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.05a
    • /
    • pp.208-211
    • /
    • 2018
  • 현재 해군에서는 기존 전투함에서 사용 중인 IFF Mode 4 를 대체하여 IFF Mode 5 를 도입할 계획을 갖고 있다. IFF Mode 5 기능을 사용하기 위해서는 IFFMode 5 설치뿐만 아니라 IFFMode 5 와 연동을 수행하는 기존 전투함의 전투체계 변경도 필요하다. 하지만 기존 전투함의 전투체계를 변경할 경우 개발 비용과 개발 기간이 크게 증가하게 된다. 본 논문에서는 이를 완화시키기 위한 방안에 대해서 프로토타입을 통해 검증했던 프로젝트를 소개하고, 기존의 전투체계를 변경하지 않는 방식으로 IFFMode 5 와 연동을 수행할 수 있는 게이트웨이 설계 방안을 제시한다.

The Vibration Characteristic Analysis by Mode Variation of Ring Type Ultrasonic Motor (링형 초음파모터의 모드선정에 따른 진동특성 해석)

  • 윤신용;백수현;김현일
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.5
    • /
    • pp.309-317
    • /
    • 2004
  • This paper suggested the vibration characteristic improvement by variation mode of ring type ultrasonic motor. Design for the piezoelectric ceramic and elastic body of stator were calculated by the finite element method(FEM) that consider the resonance frequency, vibration mode and coupling efficiency etc. Through the result of vibration analysis from 6 order mode to 8 mode, the 7 order mode was gained very an excellent results that it was the coupling efficient, minimum power loss and bending vibration value. Here over 7 order mode, this paper was acquired that an output current for input voltage was very a large increased results. The result of vibration calculation, from thickness 0.5[mm] to 2[mm], knew the fact that the vibration displacement at 0.5[mm] is an high value too. From such result, this paper was manufactured the ultrasonic motor of outer diameter 5O[mm] , inter 22[mm] having the about 43.86[KHz] resonance frequency. We have gated that a simulation result is 42.2[KHz] and an experiment result is 43.86[KHzl The propriety of this paper was established though comparison. investigation of simulation and experiment result.

The Study of Effectiveness of Volume Mode in Pediatric CT (소아 전산화단층촬영에서 Volume Mode의 유용성 연구)

  • Park, Yun;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.425-431
    • /
    • 2014
  • The purpose of this study is to analyze dose comparison and image quality evaluation according to Volume and Helical mode using ATOM Phantom. It is to actively use the Volume mode in pediatric CT examinations. There was no significant difference with Helical and Volume in the value of Noise, HU, SNR(p>0.05). All dose values was no statistical difference(p>0.05). In the value of DLP and effective dose by part, Volume mode was measured lower than Helical mode. For qualitative analysis, by scan parameter helical mode showed respectively 2.6, 3.3, 4.36 and Volume mode indicated 2.8, 3.64, 4.44 point. Image evaluation for the follow-up, Helical mode and Volume mode were respectively 3.8 and 3.83. In fact, There was no significant difference. In CT scans in children under 5 years, because 640-MDCT Volume scan dose compared with Helical mode is lower and there is no significant difference with two modes in the image quality, 640-MDCT Volume scan is thought to be useful for pediatric CT scans.