• 제목/요약/키워드: Mode Pair

검색결과 171건 처리시간 0.024초

MOSFET 검출기의 방사선 측정 기법 (A Methodology of Radiation Measurement of MOSFET Dosimeter)

  • 노영찬;이상용;강필현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.159-162
    • /
    • 2009
  • The necessity of radiation dosimeter with precise measurement of radiation dose is increased and required in the field of spacecraft, radiotheraphy hospital, atomic plant facility, etc. where radiation exists. Until now, a low power commercial metal-oxide semiconductor(MOS) transistor has been tested as a gamma radiation dosimeter. The measurement error between the actual value and the measurement one can occur since the MOSFET(MOS field-effect transistor) dosimeter, which is now being used, has two gates with same width. The measurement value of dosimeter depends on the variation of threshold voltage, which can be affected by the environment such as temperature. In this paper, a radiation dosimeter having a pair of MOSFET is designed in the same silicon substrate, in which each of the MOSFETs is operable in a bias mode and a test mode. It can measure the radiation dose by the difference between the threshold voltages regardless of the variation of temperature.

  • PDF

AC/DC 계통의 전압안정도 해석 (Voltage Stability Analysis of AC/DC Systems)

  • 남해곤;김용학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.89-91
    • /
    • 1995
  • This paper describes an extension or a pair or multiple load flow solutions and nose curve method developed for voltage stability analysis or AC power systems to AC/DC systems. In this approach the converters are regarded as voltage dependent loads. Assuming that the converters at the unstable (-mode) solution consume the same power equal to the power at the stable (+mode) solution, the unstable solutions or the nose curves arc determined. This method is very efficient since estimating voltage collapse point and voltage stability margin arc determined by a few iterations of multiple load flow solutions. Also the method has the advantages that since the structure or Jacobian matrix is same with that of AC load flow, modal analysis or voltage stability is readily applicable if desired.

  • PDF

LVDS I/O Cells with Rail-to-Rail Input Receiver

  • Lim, Byong-Chan;Lee, Sung-Ryong;Kwon, Oh-Kyong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.567-570
    • /
    • 2002
  • The LVDS (Low Voltage Differential Signaling) I/O cells, fully compatible with ANSI TIA/ EIA-644 LVDS standard, are designed using a 0.35${\mu}m$ standard CMOS technology. With a single 3V supply, the core cells operate at 1.34Gbps and power consumption of the output driver and the input receiver is 10. 5mW and 4.2mW, respectively. In the output driver, we employ the DCMFB (Dynamic Common-Mode FeedBack) circuit which can control the DC offset voltage of differential output signals. The SPICE simulation result of the proposed output driver shows that the variation of the DC offset voltage is 15.6% within a permissible range. In the input receiver, the proposed dual input stage with a positive feedback latch covers rail-to-rail input common-mode range and enables a high-speed, low-power operation. 5-channels of the proposed LVDS I/O pair can handle display data up to 8-bit gray scale and UXGA resolution.

  • PDF

대변위 측정을 위한 다중화된 광섬유 센서 (A multiplexed fiber-optic sensor for measuring large displacement)

  • 유정애;권일범;조재흥;서대철
    • 센서학회지
    • /
    • 제14권3호
    • /
    • pp.169-179
    • /
    • 2005
  • A multiplexed bend loss type single-mode fiber-optic sensor system was prepared to measure the displacement of several cm of the civil engineering structures such as many bridges, tunnels and various buildings. This bend loss type fiber-optic sensor used the signal difference between two reflection signals due to various bend losses generating at a pair of optical connectors by using OTDR (optical time domain reflectometer) for measuring displacements. And the experiments were conducted for showing the measurement feasibility on the range of 10 cm, and the multiplexing experiments were also performed to measure the displacements of 5 measuring positions of an object by setting these 5 fiber-optic sensors on a single mode fiber simultaneously.

3점 압축하중을 받는 원판의 광탄성 해석 (ANALYSIS FOR 3-POINT LOADED DISC BY PHOTOELASTICITY)

  • 함경춘;이하성
    • 한국안전학회지
    • /
    • 제7권1호
    • /
    • pp.5-12
    • /
    • 1992
  • Disc specimen with the center crack and edge crack simulated by two-dimensional static method is used to analyze the stress field around the crack tip in terms of the stress intensity factor, K. A simple and convenient method of testing to realize the mifed mode stress intensity factor of the cracked body is used, The conclusions obtatined in this photoelastlc analysis are as follows ; 1. According to this experiment, cracked disc specimen can be used to demonstrate the mixed mode stress intensity factor analysis by simply changing the crack angle from the loading line. 2. Despite the simplicity and continuous data reading, the photoelastic method shows the slightly lower strain reading comparing to the FEM analysis method. 3. In this photoelastic analysis, $K_{I}$ of center cracked disc specimen under a pair of compressive load shows negative value as the crack angle increases over 30$^{\circ}$.

  • PDF

가변구조계에 대한 스윗칭 초평면 설정의 한 방법 (Construction Method of Switching Hyperplane for Variable Structure Systems)

  • 오세준;김상봉;하주식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제14권3호
    • /
    • pp.42-51
    • /
    • 1990
  • A construction method of a switching hyperplane for the Variable Structure Systems, which have robustness for parameter variations and noises in sliding mode is presented. The problem of composing a switching hyperplane is considered as a special case of the pole assignment for a closed-loop system. It is shown that the condition for constructing arbitrarily a switching hyperplane matrix C is equivalent to the controllability of the pair matrix(A, B) for the system, and then an algorithm of obtaining the switching hyperplane is proposed. It is also proved that zeros of the system are invariable in the sliding mode, and the stability for the system dynamic is equivalent to the stability of PA $\textit{ker}$ C. The applicability of the method proposed in the paper is shown by the simulation results for an example system.

  • PDF

Kerr 렌즈 모드록킹된 티타늄 사파이어 레이저에서 10fs 이하 펄스의 발생 (Generation of sub-10-fs Pulses from a kerr-Iens mode-locked Ri:sapphire Iaser)

  • 홍경한;차용호;강영일;남창희
    • 한국광학회지
    • /
    • 제11권1호
    • /
    • pp.43-46
    • /
    • 2000
  • Kerr 렌즈 모드록킹된 티타늄 사파이어 레이저에서 상용화된 광학부품만을 이용하여 9 fs의 펄스를 생성하였다. 공진기 내부와 출령경을 지나면서 발생하는 군속도 분산을 각각 용융 프리즘 쌍을 이용하여 보상하였고, 넓은 스펙트럼을 얻기 위하여 광대역 거울을 사용하였다. 이전에 사용했던 광대역 거울과 반사율을 비교해 봄으로서 10fs 미만의 극초단 펄스를 생성하기 위해서는 180nm 이상의 넓은 반사대역을 갖는 거울을 선택하는 것이 필수적임을 확인하였다.

  • PDF

PCB에서 필드 상쇄 기법을 적용한 Cat. 5E급 모듈라잭 설계에 관한 연구 (A Study on the PCB Design of a CAT.5E Modular Jacks Employing Field Cancellation Techniques)

  • 류대우;이중근
    • 한국전자파학회논문지
    • /
    • 제12권1호
    • /
    • pp.136-142
    • /
    • 2001
  • 본 논문은 필드 상쇄 기술을 사용하여 PCB(printed circuit board) 기판으로 모듈라 잭 내부구조를 설계한 후 측정하여 이론과 실제가 일치함을 보였다. 모듈라 플러그의 경우, Maxwell 3D parameter extractor S/W를 사용하여 M.O.M(method of moment) 방식으로 예상되는 C(capacitance) 값을 추출한 후, 그 값에 맞는 PCB를 설계한 후 , 시뮬레이션하여 최적의 값을 얻었고, 이를 근거로 PCB를 제작하여 네트웍 분석기(network analyzer)로 측정항목들을 측정하였다. 측정 결과와 필드 상쇄 기술을 사용한 시뮬레이션 결과가 잘 일치함을 보였다.

  • PDF

Design and Test Results of 6-kA HTS-Copper Current Leads with HTS Section Operating in the Current-Sharing Mode

  • Lee, Haigun;Kim, Ho-Min;Yukikazu Iwasa;Kim, Keeman;Paul Arakawa;Greg Laughon
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권2호
    • /
    • pp.100-108
    • /
    • 2003
  • This paper presents the design and performance results of a pair of 6-kA high-temperature superconducting (HTS)-copper current leads, in which, over a short length at the warm end (e.g.,77K) of each HTS section, comprised of paralleled Bi-2223/Ag-Au tapes, is operated in the current-sharing mode. Because of their reliance on vapor cooling, the leads are applicable only to liquid helium cooled superconducting magnets such as those used in high-energy Physics accelerators and fusion machines. The experimental measurements have demonstrated that key performance data of the new 6-kA HTS-Copper leads agree reasonably well with those expected from design.

링 구조물의 맥놀이의 선명도와 맥놀이 주기 조절에 관한 연구 (A Study on the Control of the Beat Clarity and the Beat Period in a Ring Structure)

  • 김석현
    • 한국소음진동공학회논문집
    • /
    • 제18권11호
    • /
    • pp.1170-1176
    • /
    • 2008
  • In this study, we propose a new method to control both the beat clarity and beat period in a ring structure. An equivalent ring which satisfies the measured mode condition is determined by using the equivalent ring theory. Theoretical analysis and finite element analysis on the equivalent ring are performed to investigate the effect of the local structural modification on the beat clarity and beat period. Beat clarity and period are improved by attaching asymmetric mass or decreasing local thickness. Through the analysis on the equivalent ring, the proper position and the amount of the local variation are determined to satisfy the required clarity and period condition. All the analysis results are compared and verified by the experiment.