A Study on the PCB Design of a CAT.5E Modular Jacks Employing Field Cancellation Techniques

PCB에서 필드 상쇄 기법을 적용한 Cat. 5E급 모듈라잭 설계에 관한 연구

  • 류대우 (한양대학교 전자통신공학과) ;
  • 이중근 (한양대학교 전자통신공학과)
  • Published : 2001.01.01

Abstract

In this paper, a method of canceling and suppressing differential mode crosstalk noise signals caused by non-uniform coupling between two transmission lines in UTP (unshielded twisted pair) modular jacks is discussed. Differential mode crosstalk noise signals in balanced transmission lines with UTP modular jacks were suppressed, by applying field cancellation techniques to this modular jack. To verify an effectiveness of the field cancellation techniques, 8 pin modular jacks were made, and the NEXT (Near End Crosstalk) losses were measured to prove its applicability by the network analyzer(HP8720C) at 100 Mb/s.

본 논문은 필드 상쇄 기술을 사용하여 PCB(printed circuit board) 기판으로 모듈라 잭 내부구조를 설계한 후 측정하여 이론과 실제가 일치함을 보였다. 모듈라 플러그의 경우, Maxwell 3D parameter extractor S/W를 사용하여 M.O.M(method of moment) 방식으로 예상되는 C(capacitance) 값을 추출한 후, 그 값에 맞는 PCB를 설계한 후 , 시뮬레이션하여 최적의 값을 얻었고, 이를 근거로 PCB를 제작하여 네트웍 분석기(network analyzer)로 측정항목들을 측정하였다. 측정 결과와 필드 상쇄 기술을 사용한 시뮬레이션 결과가 잘 일치함을 보였다.

Keywords

References

  1. Bell System. Tech. Journal v.52 Crosstalk in Uniformly Coupled Lossy Transmission Lines J. C. Issacs;N. A. Strakhov
  2. IEEE Trans. Electromag. Compat. v.EMC-18 Computation of the transmission line inductance and capacitance matrices from the generalized capacitance matrix Clayton R. Paul;Arthur E. Feather
  3. SP-4195-B(to be published as ANSI/TIA/EIA-568-A-5), Additional Transmission Performance Specifications for 4-pair 100Ω Category 5E Cabling Copper Cabling Systems Subcommittee
  4. SP-4195-B(to be published as ANSI/TIA/EIA-568-A-5), Additional Transmission Performance Specifications for 4-pair 100Ω, Enhanced Category 5 Cabling UTP System Task Group
  5. 한국전자파학회논문집 v.10 no.1 Crosstalk를 방지한 100 MHz 고속 데이터 전송 Modular Jack의 설계 및 제작에 관한 연구 이중근;안현수
  6. 2000년도 춘계 마이크로파 및 전파학술대회 논문집 v.23 no.1 필드 상쇄 기법에 의한 Cat. 5E급 모듈라잭 설계에 관한 연구 이중근;류대우
  7. Asia-Pacific Conference on Environmental Electromagnetics CEEM' 2000 A study on a reduced crosstalk for the design of 'cat. 6' high speed data transmission modular jack Joong-Geun Rhee
  8. International Conference on Computational Electromagnetics and Its Applications '99 A study on a reduced crosstalk for the design on 'enhanced cat. 5' high speed data transmission modular jack Joong-Geun Rhee
  9. Workshop on Electromagnetics and Microwave Advances Crosstalk reduction techniques in high-speed data transmission for enhanced cat. 5 modular jack Joong-Geun Rhee
  10. 전파기술 세미나 차세대 초고속 LAN용 modular jack(cat. 6) 개발 이중근
  11. Electromagnetic Compatibility Jasper Goedbloed
  12. Electromagnetic Compatibility Principles and Application David A. Weston
  13. Commercial Building Telecommunications Cabling Standard, TIA/EIA Standard, ANSI/TIA/EIA-568-A-1995 TIA/EIA
  14. Information Technology-Generic Cabling for Customer Premises International Standard ISO/IEC 11801
  15. EMC and the Printed Circuit Board MARK I. MONTROSE
  16. 인쇄기판회로 패턴을 이용한 인핸스드 카테고리 5급 모듈라 잭 이중근;류대우
  17. 인쇄기판회로 패턴을 이용한 인핸스드 카테고리 5급 모듈라 잭 이중근;류대우