• Title/Summary/Keyword: Mode Count

Search Result 100, Processing Time 0.03 seconds

Low-power Frequency Offset Synchronization for IEEE 802.11a Using CORDIC Algorithm (CORDIC을 이용한 IEEE 802.11a용 저전력 주파수 옵셋 동기화기)

  • Jang, Young-Beom;Han, Jae-Woong;Hong, Dae-Ki
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.2
    • /
    • pp.66-72
    • /
    • 2009
  • In this paper, an efficient frequency offset synchronization structure for OFDM(Orthogonal Frequency Division Multiplexing) is proposed. Conventional CORDIC(Coordinate Rotation Digital Computer) algorithm for frequency offset synchronization utilizes two CORDIC hardware i.e., one is vector mode for phase estimation, the other is rotation mode for compensation. But proposed structure utilizes one CORDIC hardware and divider. Through simulation, it is shown that hardware implementation complexity is reduced compared with conventional structures. The Verilog-HDL coding and front-end chip implementation results for the proposed structure show 22.1% gate count reduction comparison with those of the conventional structure.

Design and Implementation of OFDM Frequency Offset Synchronization Block Using CORDIC (CORDIC을 이용한 OFDM 주파수 옵셋 동기부 설계 및 구현)

  • Jang, Young-Beom;Han, Jae-Woong;Hong, Dae-Ki
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.5
    • /
    • pp.118-125
    • /
    • 2008
  • In this paper, an efficient frequency offset synchronization structure for OFDM(Orthogonal Frequency Division Multiplexing) is proposed. Conventional CORDIC(Coordinate Rotation Digital Computer) algorithm for frequency offset synchronization utilizes two CORDIC hardware i.e., one is vector mode for phase estimation, the other is rotation mode for compensation. But proposed structure utilizes one CORDIC hardware and divider. Through simulation, it is shown that hardware implementation complexity is reduced compared with conventional structures. The Verilog-HDL coding and front-end chip implementation results for the proposed structure show 22.1% gate count reduction comparison with those of the conventional structure.

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF

Clinical Usefulness of 99mTc-DMSA Renal SPECT Using High Sensitivity-All Purpose Collimator for Pediatric Patients (고감도 범용성 콜리메이터를 이용한 소아 환자 99mTc-DMSA 신장 SPECT의 유용성)

  • Kim, Jin-Eui;Kim, Jung-Soo;Han, Jae-Bok;Choi, Nam-Gil
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.219-231
    • /
    • 2016
  • $^{99m}Tc$-DMSA planar scan that can analyze the functions of kidney quantitatively provides less information on a lesion than tomography scanning. Therefore, this study applied a high sensitivity all-purpose collimator that is sensitive to photonic signals to $^{99m}Tc$-DMSA and carried out a clinical scan with single photon emission computed tomography (SPECT). And diagnostic accuracy and time requirement of were analyzed to know the clinical usefulness of the applied scanning method. 10 subjects were intravenously injected with radiopharmaceutical product (1.0-1.2 MBq/kg) and scanned by a gamma camera with planar scanner (high resolution (HR)-mode, $256{\times}256$, 50 kcts/view, 4 image) and SPECT (HR / high sensitive (HS)-mode, $128{\times}128$, step and shoot, $180^{\circ}$, variable sec/angle, total 64 frame, OSEM reconstruction), respectively. The collected data was compared with an analysis program. The results showed that HS-mode SPECT detected total counts 1.8-5.6 times more than planar scan. Relative renal function evaluated based on the counts was not significantly different by two scanning methods (p=0.96) and it turned out that test time was shortened by 39% when HS-mode SPECT was used. Therefore, SPECT using HR, HS-mode collimator could analyze renal function more quantitatively than using planar scan and the former could diagnose the location information of a lesion more accurately than the latter as well as shortened test time requirement, which demonstrated the clinical usefulness of $^{99m}Tc$-DMSA renal SPECT using high sensitivity all purpose collimator.

Hardware Implementation of HEVC CABAC Binarizer

  • Pham, Duyen Hai;Moon, Jeonhak;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.18 no.3
    • /
    • pp.356-361
    • /
    • 2014
  • This paper proposes hardware architecture of HEVC (high efficiency video coding) CABAC (context-based adaptive binary arithmetic coding) binarizer. The proposed binarizer was designed and implemented as an independent module that can be integrated into HEVC CABAC encoder. It generates each bin string of each syntax element in a single cycle. It consists of controller module, TU (truncated unary binarization) module, TR (truncated Rice binarization) module, FL (fixed length binarization) module, EGK (k-th order exp-Golomb coding) module, CALR (coeff_abs_level_remaining) module, QP Delta (cu_qp_delta_abs) module, Intra Pred (intra_chroma_pred_mode) module, Inter Pred (inter_pred_idc) module, and Part Mode (part_mode) module. The proposed binarizer was designed in Verilog HDL, and it was implemented in 45 nm technology. Its operating speed, gate count, and power consumption are 200 MHz, 1,678 gates, and 50 uW, respectively.

Evaluation of Physical Characteristics of Discovery ST scanner Using NEMA NU2-2001 Standard (NEMA NU2-2001을 이용한 PET-CT 스캐너의 물리적 특성평가)

  • Lee, Byeong-Il
    • Journal of Integrative Natural Science
    • /
    • v.1 no.2
    • /
    • pp.79-83
    • /
    • 2008
  • As a new standard for performance measurement, NEMA NU2-2001 was presented recently. In this study, I investigated the spatial resolution, sensitivity, scatter fraction, and noise equivalent count ratio (NECR) in order to know the information of physical characteristics and system performance of GE discovery ST using this new standard. Bismuth germinate crystals ($6{\times}6$ array, $6.3mm{\times}6.3mm{\times}30mm$) were used in discovery ST (energy window:375-650 keV, coincidence window:11.7 nsec). To measure the sensitivity, five aluminum sleeves (Data Spectrum Corp., Chapel Hill, NC., USA, thickness:1.25 mm)-NEMA sensitivity phantom- filled with F-18 solution were used. Successive measurements in 2D and 3D acquisition mode were made with a line source at the center of transaxial field of view and 10 cm off from the center until the count was over 500,000. Spatial resolution was estimated using a point source (F-18, 0.1 mCi) at different locations in the FOV. Scatter fraction and NECR was tested using a NEMA scatter phantom. Dynamic data were acquired for 7 half-lives using F-18 solution. And true to background ratio was averaged at last three frames when the random rate was as small as ignorable for the calculation of scatter fraction. We anticipate this overall evaluated results could be used for the quality assurance and optimized image acquisition for clinical research.

  • PDF

Effect of Oriental Postpartum Management on the Hematology and Blood Chemistry in Puerperium Maternity (한방산후조리가 산욕기 산모의 혈액 및 생화학검사에 미치는 영향)

  • 최신웅;김정연
    • The Journal of Korean Medicine
    • /
    • v.22 no.4
    • /
    • pp.121-130
    • /
    • 2001
  • Objectives : As participation of women in public affairs increases, they are more concerned about postpartum management. However, objectivity of its effect tends to be insufficient. This study was done to investigate the clinical applications of postpartum management in Oriental Medicine. Subjects and methods : This clinical study was done on 74 patients who were treated by postpartum management in the Oriental Medical Hospital of Woosuk University from November 1999 to August 2000. We analyzed the changes of hematology and blood chemistry. Then, we examined the differences between two groups : one group had undergone vaginal duct delivery and the other cesarean section in mode of delivery. Results : I) The ratio of vaginal duct delivery to cesarean section was 39:35. Two major age groups were 25-29 and 30-34, respectively 43% and 35%. 2) According to the hematology, hemoglobin, hematocrit, REC and platelet count significantly increased, while WBC and ESR level significantly decreased. 3) To the hematology by mode of delivery, WBC level decreased in both groups. WBC level of the vaginal duct delivery group was significantly lower than that of cesarean section. RBC level increased in both groups, the cesarean section group were statistically significant. Hemoglobin, hematocrit and platelet count increased but they were not significant in either group. 4) To the blood chemistry, Triglyceride (TG), protein, albumin and sodium levels were significantly increased but cholesterol, ALT, BUN, creatinine, potassium and chloride levels were not statistically significant. 5) According to the blood chemistry by mode of delivery, TG level of the vaginal duct delivery group was significantly reduced but the others were not significant. Conclusious : The effective results were shown that postpartum management by Oriental Medicine assisted postpartum health care as well as postpartum anemia.

  • PDF

A Level Dependent Source Concoction Multilevel Inverter Topology with a Reduced Number of Power Switches

  • Edwin Jose, S.;Titus, S.
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1316-1323
    • /
    • 2016
  • Multilevel inverters (MLIs) have been preferred over conventional two-level inverters due to their inherent properties such as reduced harmonic distortion, lower electromagnetic interference, minimal common mode voltage, ability to synthesize medium/high voltage from low voltage sources, etc. On the other hand, they suffer from an increased number of switching devices, complex gate pulse generation, etc. This paper develops an ingenious symmetrical MLI topology, which consumes lesser component count. The proposed level dependent sources concoction multilevel inverter (LDSCMLI) is basically a multilevel dc link MLI (MLDCMLI), which first synthesizes a stepped dc link voltage using a sources concoction module and then realizes the ac waveform through a conventional H-bridge. Seven level and eleven level versions of the proposed topology are simulated in MATLAB r2010b and prototypes are constructed to validate the performance. The proposed topology requires lesser components compared to recent component reduced MLI topologies and the classical topologies. In addition, it requires fewer carrier signals and gate driver circuits.

3-Dimensional LADAR Optical Detector Development in Geiger Mode Operation (Geiger Mode로 동작하는 3차원 LADAR 광수신기 개발)

  • Choi, Soon-Gyu;Shin, Jung-Hwan;Kang, Sang-Gu;Hong, Jung-Ho;Kwon, Yong-Joon;Kang, Eung-Cheol;Lee, Chang-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.4
    • /
    • pp.176-183
    • /
    • 2013
  • In this paper, we report the design, fabrication and characterization of the 3-Dimensional optical receiver for a Laser Detection And Ranging (LADAR) system. The optical receiver is composed of three parts; $16{\pm}16$ Geiger Mode InGaAs Avalanche Photodiode (APD) array device operated at 1560 nm wavelength, Read Out Integrated Circuit (ROIC) measuring the Time-Of-Flight (TOF) of the return signal reflected from target objects, a package and cooler maintaining the proper operational condition of the detector and control electronics. We can confirm that the LADAR system can detect the signal from a target up to 1.2 km away, and it showed low Dark Count Rate (DCR) of less than 140 kHz, and higher than 28%-Photon Detection Efficiency (PDE). This is considered to be the best performance of the $16{\pm}16$ FPA APD optical receiver for a LADAR system.

Easily Adaptable On-Chip Debug Architecture for Multicore Processors

  • Xu, Jing-Zhe;Park, Hyeongbae;Jung, Seungpyo;Park, Ju Sung
    • ETRI Journal
    • /
    • v.35 no.2
    • /
    • pp.301-310
    • /
    • 2013
  • Nowadays, the multicore processor is watched with interest by people all over the world. As the design technology of system on chip has developed, observing and controlling the processor core's internal state has not been easy. Therefore, multicore processor debugging is very difficult and time-consuming. Thus, we need a reliable and efficient debugger to find the bugs. In this paper, we propose an on-chip debug architecture for multicore processors that is easily adaptable and flexible. It is based on the JTAG standard and supports monitoring mode debugging, which is different from run-stop mode debugging. Compared with the debug architecture that supports the run-stop mode debugging, the proposed architecture is easily applied to a debugger and has the advantage of having a desirable gate count and execution cycle. To verify the on-chip debug architecture, it is applied to the debugger of the prototype multicore processor and is tested by interconnecting it with a software debugger based on GDB and configured for the target processor.