• Title/Summary/Keyword: Mock-up

Search Result 803, Processing Time 0.04 seconds

Mock-up Model of the Environment Assessment Study on Red-clay and Cement (Mock-up모델을 이용한 황토 및 시멘트의 환경요소 평가 연구)

  • Choi, Yool;Song, Hyeun-Guen
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study is to measure the environmental effects of different alternative building materials. The following building materials were tested: clay bricks, cement wall, and red-clay plaster. Four mock-up models were constructed using clay bricks, cement wall, red-clay plaster and the last model as the control model. The effects of the above four building materials on temperature, humidity, the emissions of formaldehyde, and V.O.C were measured. This experiment was conducted during September. The conclusions are as follows. Clay bricks were able to control temperature, humidity and filter formaldehyde by itself. The environment within the cement wall was not affected by the humidity changes outside. Red-clay plaster walls had little impact on the environment because it is very thin.!

Execution of High Fluidity Concrete by Flowing Method (유동화 공법을 적용하여 제조한 고유동 콘크리트의 시공)

  • 한민철;손성운;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.28-33
    • /
    • 2001
  • This paper presents the results of mock up test on the manufacturing of high fluidity concrete by applying flowing methods with segregation reducing type superplasticizer(SRS). Three kinds of mock up structure are made such as. conventional concrete(A), high fluidity concrete(B) and high fluidity concrete incorporating 20% of fly ash(C). Physical and mechanical properties, temperature history of structure and nondestructive test are performed. Segregation reducing type superplasticizer is put into base concrete at field, and base concrete is also flowed at field. C mock up structure which requires 0.85% of SRS to flow base concrete shows most desirable performance at fresh state. The highest rising temperature shows the lowest at C structure among the tested structures. Strength variations before and after flowing also show the lowest values at C structures.

  • PDF

A Study on the Comparison of the Illuminance Values from Lighting Simulation and Mock-up Experiment for Suitable Application of Lighting Simulation (조명시뮬레이션의 적절한 사용을 위한 Mock-up 실험 측정값과 주광 시뮬레이션 결과값 비교에 관한 연구)

  • Lim, Ji-Sun;Jun, Byung-Kuk;Kim, Yu-Sin;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.17-20
    • /
    • 2009
  • Available daylight in inside offers comfortable view environment, and psychological and physical advantages to people in a room. Architecture design has need of daylight prediction for reflection efficiently daylight. But it is difficult to predict the illuminance values in daylight system. Using various lighting simulation software is easy and simple, but we can find different results under the same conditions. This study compares with illuminance values from simulation (Lightscape 3.2, RELUX 2007, RADIANCE 3.9) and Mock-up experiment with the same space and parameter of daylight (location of space and window, date, time and sky condition).

  • PDF

An Experimental Study on Insulation and Preventing Condensation Performance of Ventilated Curtain Wall (Mock-up 실험을 통한 통기성 커튼월의 단열 및 결로방지 성능평가)

  • Lee, Mi-Jin;Lee, Sun-Woo;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1081-1086
    • /
    • 2006
  • Curtainwall systems has been applied to buildings widely for constructability. However, as cutainwall system include many building materials, they become to damaged vapor barrier and incur condensation. Natural ventilation of an air cavity in a curtainwall is expected to be an prevention of condensation in inner wall and reduce cooling energy in summer. The objective of this experimental study is to evaluating the insulation and condensation Performance of ventilated curtainwall with ventilated cavity depth and ratio of opening area.

  • PDF

Mock-up Test of Setting Estimation System For AI-based Concrete Finishing Automation System (AI 기반 콘크리트 마감 자동화 시스템용 응결추정계의 Mock-up Test)

  • Han, Soo-Hwan;Lim, Gun-Su;Han, Jun-Hui;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.129-130
    • /
    • 2022
  • This study is conducted to identify improvements in the setting time estimation system through the Mock-up test of the finishing automation system and the setting estimation system. As a result of the study, it is necessary to adjust the spring strength of the setting time estimator and the diameter and length of the estimation needle so that the value of the hardness can be measured from 15HD to around 40HD.

  • PDF

Comparative Analysis on the Mock-ups' Configuration and Monitoring Protocol System of Advanced Daylighting Systems for Daylighting Experiment - Focused on IEA SHC Task21- (첨단채광시스템 실험용 Mock-Up 모형의 형상 및 모니터링 프로토콜 시스템에 관한 비교분석 - IEA SHC Task21을 중심으로-)

  • Jeong, In-Young;Choi, Sang-Hyun;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.4 no.1
    • /
    • pp.11-20
    • /
    • 2004
  • Innovative daylighting systems in buildings in various climatic zones around the world have been developed under the IEA SHC Task21. The performance assessment were obtained by monitoring the most systems using full-scale test model rooms or actual buildings under real sky conditions. This study aims to analyze the configuration and monitoring system of the nine Mock-up models of the IEA SHC Task21 comparatively. For the purpose, the geometry of the test rooms (length, width, height, window area, glazed area and occupied), reflectance of walls, floor and ceiling, transmittance of glazing (transmittance for hemispherical irradiation, normal irradiation and U-value) were compared. And equipment for measurement (manufacturer, range, calibration, maximum calibration error, cosine response error, fatigue error), and data acquisition system (manufacturer, type, number of differential analogue input channels, A/D converter resolution in bits, data acquisition software) were also analyzed comparatively. Some findings of these experimental methodology of standard monitoring have been proven to be a valuable one for future assessment of advanced daylighting systems in our country.

Porcelain Laminate Veneer Restoration (Porcelain laminate veneer의 수복)

  • Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.191-200
    • /
    • 2012
  • The patients' demand for treatment of unesthetic anterior teeth is steadily growing. Accordingly, several treatment options such as porcelain laminate veneers(PLV) have been proposed to restore the esthetic appearance of the dentition. Porcelain laminate veneers are considered minimally invasive, but they also require removal of sound enamel. One critical step in the porcelain laminate veneer technique is the achievement of sufficient ceramic thickness, and several different strategies for tooth preparation can be found in the literature. This clinical report describes a step-by-step protocols for preparation of these restorations used with the silicone index from diagnostic wax-up and the acrylic resin mock-up. Conservative use of porcelain laminate veneers provided satisfactory esthetic outcomes and preserved sound tooth structure.

Esthetic improvement in patient with deep bite using porcelain laminate veneers and a full veneer crown (과개교합 환자에서 도재 라미네이트 비니어와 전부도재관을 이용한 심미수복 증례)

  • Yoon, Jong-Sang;Shin, Soo-Yeon;Lee, Jonghyuk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.192-198
    • /
    • 2014
  • This case is a porcelain laminate veneer (PLV) and all-ceramic crown treatment case on a female patient in her thirties who visited for esthetic improvement. The patient's chief complaint was protrusive and uneven anterior teeth, and she wanted minimum tooth reduction. The patient was in skeletal class II deep bite. Considering this, check bite method was used for mounting on articulator during diagnostic wax-up. Tooth reduction was done using mock-up base on diagnostic wax-up, and the amount of deletion was checked by index. For the accordance of shade, PLVs were restored in prior to all ceramic crown. After using all-ceramic crown, satisfactory esthetic improvement was obtained.

Autogenous Shrinkage Mock-up Test of High Performance Concrete by Emulsified Refined Cooking Oil (유화처리 정제식용유를 사용한 고성능 콘크리트의 자기수축 Mock-up 실험)

  • Jo, Man-Ki;Han, Cheon-Goo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.3
    • /
    • pp.307-315
    • /
    • 2016
  • The aim of this research is analyzing the fundamental properties and autogenous shrinkage reducing performance of 70 and 100MPa grade high performance concrete including emusified refined cooking oil(ERCO) under the mock-up conditions. As a results of experiment, the mixture contained 0.5% of ERCO showed slightly decreased slump flow while the slump was increased and segregation resistance performance was improved as 2.5 of EIS. For air content, all mixtures satisfied target air content with increased unit weight and delayed setting time with ERCO addition. In the case of compressive strength, when ERCO was added 0.5%, the result of approximately 5 to 10% of increased compressive strength was observed. For the autogenous shrinkage, ERCO contributed on 20-30% of shrinkage reducing performance comparing to Plain mixture without ERCO. It is considered that capillary pore filling action of soap particles occurred by the reaction of ERCO in cement paste between fatty aicd and calcium hydroxide contributed the shrinkage reducing performance. Based on these mock-up test results, application of the high performance concrete mixture with ERCO on CFT actual structure was decided.

Effect of Replacement of 5~13mm Recycled Coarse Aggregates on Field Applicability of the Concrete through Mock-up Test (목업 시험을 통한 5~13mm 순환 굵은골재 치환 사용이 콘크리트의 현장적용성에 미치는 영향 고찰)

  • Han, Min-Cheol;Song, Young-Woo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.1
    • /
    • pp.59-67
    • /
    • 2017
  • The objective of this paper is to investigate experimentally the effect of replacement of recycled coarse aggregates with 5~13mm in size on a field applicability of concretes through Mock-up test. Seven different mock-up specimens were prepared with the size of $1200{\times}800{\times}800mm$ simulating column and wall. For the concrete mixtures, 24MPa, 27MPa and 40MPa of nominal strength were adopted with 30% and 70%(only for 24MPa) of 5~13mm recycled coarse aggregate (RCA) replacement and without 5~13mm RCA(Plain). For test items, slump, slump flow, compressive strength with different curing conditions, core drilling, rebound numbers and drying shrinkage were measured. Test results indicated that 30% of 5~13 mm RCA replacement resulted in increase in slump, slump flow and resistance against segregation, while air contents decreased compared to those of plain mixture. Compressive strength of concrete with 30% of 5~13mm RCA was shown to be higher than that of plain mixture due to optimum packing effect associated with presence of well graded aggregates. Rebound number of the mock-up specimen with 30% of 5~13mm RCA had lower fluctuation according to hitting location than that of plain mock-up specimen. It is believed from the results of the study that replacement of 30% of 5~13mm RCA brings desirable improvement in various aspect of concrete performance due to associated dense packing effect.