• Title/Summary/Keyword: Mock-Up Specimen

Search Result 50, Processing Time 0.024 seconds

Research on the Mock-up for CFT Using 100MPa High Strength Concrete and 800MPa High Strength Steel (800MPa 고강도 강재 및 100MPa 초고강도 콘크리트를 활용한 CFT 합성 구조 시스템 개발을 위한 현장 성능평가에 관한 연구)

  • Kim, Woo-Jae;Lee, Youg-Do;Park, Hee-Gon;Lee, Jae-Sam;Jung, Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05b
    • /
    • pp.35-37
    • /
    • 2011
  • This study was a comparison result between the laboratory and mock up test to apply the ultra high strength concrete to CFT(Concrete Filled Tube) structure. The investigated result of tendency and quality similarity of each specimen, was set up a management range according to checking the validity and suitability analysis. Also, It wil be utilized to data as construction guidelines of CFT.

  • PDF

Analysis on Shrinkage Properties of High Performance Concrete According to Mock-Up Test (고성능 콘크리트의 Mock-Up 시험에 의한 수축특성 분석)

  • Koh Kyoung Taek;Jin Hu Lin;Ryu Gum Sung;Hwang Yin Seong;Kim Do Gyum;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.545-548
    • /
    • 2004
  • This paper is to investigate the shrinkage properties of high performance concrete (HPC) with mixture adjustment by using mock-up specimens. HPC with mixture adjustment needed a higher dosage of SP agent due to fluidity reduction and a larger dosage of AE agent due to the reduction of air content. Setting time of HPC with mixture adjustment exhibited earlier than that of control HPC by as much as 6 hours. HPC with mixture adjustment gained more than 70MPa of compressive strength. Autogenous shrinkage of Control HPC was found to be $-340\times40^{-6}$ at 49days when the expansion value by thermal effect was excluded and HPC with mixture adjustment $-175\times10^{-6}$, which was the half of the value of control HPC. Drying shrinkage of center section of HPC with mixture adjustment showed similar tendency with autogenous shrinkage because of no internal moisture movement, while surface section had larger drying shrinkage. The specimen embedded with reinforcing bar had smaller deformation caused by confinement of reinforcing bar.

  • PDF

Analysis of Crack Control Effect of Ultra-low Shrinkage Concrete through Wall Mock-up Test (벽체 실물대부재실험을 통한 초 저수축 콘크리트의 균열제어 효과 분석)

  • Seo, Tae-Seok;Lee, Hyun-Seung;Kim, Kang-Min
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.45-55
    • /
    • 2022
  • Ultra-low shrinkage concrete is very effective for securing the quality and appearance of a concrete structure because it can control the drying shrinkage cracks of the concrete structure to within a certain limit. In this study, with the purpose of commercializing ultra-low shrinkage concrete, the optimal amount of expansive agent and shrinkage reducing agent was determined through a lab test, and a concrete wall mock-up test was conducted to examine the shrinkage properties and crack control effects of ultra-low shrinkage concrete. As a result, it was confirmed that there was little drying shrinkage deformation in the wall specimen, and furthermore that no cracks were generated.

Temperature History of Concrete exposed to Extremely Cold Weather with the Variation of Capacity of Heating Coil (열선 전력 용량에 따른 극한온도 조건에서의 콘크리트 온도이력 특성)

  • Jung, Eun-Bong;Jung, Sang-Hyeon;Ahn, Sang-Ku;Ko, Gyeong-Taek;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.51-53
    • /
    • 2012
  • This paper is to report the results of mock-up test for concrete during severe cold weather. The temperature is fixed at -20℃. The mock-up specimens were fabricated simulating slab, wall and column. Heating coil with different heat capacity with 5 W and 15 W were embedded at slab specimen. Test results revealed that at -20℃, temperature dropped below 0℃ since around 70 hours. It takes 7 days to gain 45°D·D of maturity for avoiding frost damage at early age.

  • PDF

A study of the Method on the Packing ability of Concrete Filled in Steel Tube Structure by High Strength and High Flowable Concrete (고강도 고유동 콘크리트를 이용한 콘크리트충전강관(CFT)구조의 충전성에 관한 공법 연구)

  • Kang, Yong-Hak;Jung, Keun-Ho;Lim, Nam-Ki;Lee, Young-Do;Jung, Jae-Young;Jung, Sang-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.1
    • /
    • pp.163-169
    • /
    • 2002
  • In this study, there are kind of property experiments like fluidity, compressive strength, bleeding measurement, concrete sink for CFT use high fluidity concrete. The property difference between before transmit and after transmit concrete in the mock up test with ready mixed concrete equipment is examined. The variable factors in mock up are diaphragm existence and nonexistence, diaphragm placing hole sizes. To investing the concrete Property under diaphragm, concrete packing ability, hydration heat, core specimen strength tests are performed.

A Study on Watertightness Improvement of Hybrid Method Using Polyvinyl Acetate(PVAc) (폴리비닐아세테이트(PVAc)를 이용한 복합공법의 수밀성능 향상에 관한 연구)

  • Ryou, Jae Suk;Song, Il Hyun;Lee, Yong Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.4
    • /
    • pp.18-24
    • /
    • 2012
  • In this study, hybrid method using polyvinyl acetate (PVAc) which has a strong adhesion and flexibility in which acrylic copolymer chemical-reaction reacts with cement, and is eco-friendly, is to improve the watertightness. The hybrid method is applied applied primarily waterproof stuff comprising silicate system and secondary mortar mixed with PVAc on the concrete surface. And then, in order to evaluate the performance, the properties of bond strength and amount of water absorption were measured. Based on the above experiments, mock-up specimens for field application were fabricated, and then the properties were evaluated as laboratory experiments. As the results, specimens cast from hybrid method using PVAc showed the best results on watertightness and bond strength. And also, with respect to experiment of mock-up specimens, the properties were in agreement with laboratory results. Especially, it could know that PVAc has strengthening effect from the results of the compressive strength. Due to outstanding results of carbonation depth and resistance to chloride ion penetration, it may be applied in weak areas such as underground and marine structures.

The Evaluation of Tube to Tubesheet Joint Part on Nuclear S/G (원자력 증기발생기 튜브/튜브시트 확관방법별 특성평가)

  • 심상한;배강국;김인수
    • Proceedings of the KWS Conference
    • /
    • 1996.05a
    • /
    • pp.34-37
    • /
    • 1996
  • The expanding method of tube to tubesheet joint part on neclear steam generators are classified into three classes of roller expanding, explosive expanding and hydraulic expanding. After the expanded Mock-Up specimen are made by the three expanding method. The general properties, microstructure/microvickers hardness, pull-out strength, hydraulic leak pressure, of tube to tubesheet joint part were inspected. and We evaluated the operation efficiency of expansion, reproduction of expanded joint about three expanding method. Through the overall evaluation of tube to tubesheet joint part, The hydraukic expanding and explosive expanding could be certificated more useful expanding method.

  • PDF

An Experimental Study on the Effect of the Early Age Curing Condition on Mass Concrete (초기재령하의 양생조건이 매스콘크리트 온도관리에 미치는 영향 연구)

  • Kim, Kwang-Don;Kim, Chun-Ho;Lee, Choong-Yong;Hwang, Min-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.685-688
    • /
    • 2006
  • As the concrete structure being large-sized and/or high-strengthened, the control of the hydration and curing temperature is made much account. This study, analysing the concrete temperature history from cylindric specimen and mock-up structures, investigates the effect of the early age curing condition and the optimum method of curing temperature control on mass concrete.

  • PDF

The Field Applicability of Road Pavement Layer with Grid Typed Reinforcement and Dispersive Fiber (그리드형 보강재와 분산성 섬유를 활용한 도로 포장층의 현장 적용 특성)

  • Park, Ju-Won;Kim, Hun-Kyum;Kim, Sung-Bo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.3
    • /
    • pp.53-59
    • /
    • 2018
  • This study analyzed the field applicability through the combination of environment-friendly grid-typed reinforcements and pre-mixed fiber with filler. The film of the grid-typed reinforcement is made by recycled PE resin. And, Ascon fiber is obtained the dispersion by pre-mixing of filler. To be able to recognize in advance the various circumstances that could arise in the construction of the road pavement layer, we conducted a basic field application test of the (Mock Up) pavement layer. As a result, it was found that the pavement with environment-friendly grid-typed reinforcement and dispersive fiber construction had improved strength, stress, and rutting resistance. It is consistent with the strength and stress results of the actual test of the mock up specimen. It is expected to perform an effective role in the safety as well as the use of environment-friendly fibers in actual construction.

Mock-up Test for Development of High Quality Concrete Using Crushed Sand in Construction Field (부순모래를 사용한 콘크리트의 고품질화 기술개발을 위한 현장 Mock-up 실험)

  • Yoo Seung-Yeup;Kim Ki-Hoon;Sohn Yu-Shin;Lee Seung-Hoon;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.17-20
    • /
    • 2005
  • This study investigates mock-up test of the concrete containing crushed sands with improved quality and following could be draws as conclusions. The slump satisfies the target value. The air content reaches the goal, however, it decreases by the occurrence of loss with elagse of age. In normal strength region, the setting time of CS24 member is shorter than that of SS24 member. In high strength region, the setting time of SS50 member is make only slower than that of CS5O because of the use of retarding AE agent. The compressive strength of the concrete using crushed sands is little higher than the concrete using washed sea sands, and the compressive strength of core sample increases at lower part. Drying shrinkage of the concrete using crushed sands is larger than that using washed sea sands. At water caring condition, both the concrete using crushed sands and using washed sands expand at first, exhibit to be swelled and with elagse of age, they remain relatirely constant. Also, the drying shrinkage occurred greatly when the width and thickness of a member are small because it is easy to evaporate the inner part vapor in the small width and thickness of a member. there can be little different according to the location of a contact gauge, however it is similar to the change of specimen's length change. The concrete using crushed sands, of which grading, grain shape and fine particle is improved, are comparable to the quality of the concrete using washed sea sand.

  • PDF