• Title/Summary/Keyword: Mixing bar

Search Result 111, Processing Time 0.029 seconds

Chloride Ion Diffusion for Ready Mixed Concrete (설계기준 압축강도별 레미콘의 염소이온 확산 특성평가)

  • Park, Dong-Cheon;Kim, Yong-Ro
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.149-150
    • /
    • 2018
  • The RC buildings which are constructed on the seaside are followed by KBC(2016) to achieve the minimization of durability damage. To control the corrosion of the reinforced steel bar by salt attack, W/C should be under 0.4 and specified concrete strength is more than 35MPa in the concrete/building construction standard specification. Ready mixed concretes which have usually include the admixtures in Busan were tested to certify the salt attack durability. In the same specified concrete strength, remarkable salt attack durability was evaluated in comparison to OPC.

  • PDF

SOLUBILITY OF NITROGEN IN CLEAN EIRE EXTINGUISHING AGENTS AT HIGH PRESSURE

  • Kim, Jae-Duck;Lim, Jong-Sung;Lee, Youn-Woo;Lee, Youn-Yong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.534-541
    • /
    • 1997
  • Isothermal solubilities of nitrogen in clean fire extinguishing agents, such as bromotrifluoromethane (Halon-1301), bromochlorodifluoromethane (Halon-121 t), 1,1,1,2,3,3,3- heptafluoropropane (HFC-227ea), and trifluoroiodomethane (FIC-13I1) were measured in a circulation-type equilibrium apparatus. The temperature range was (293.2 to 313.2) K and the pressure range was (30 to 100) bar. The experimental data were well correlated with the Peng- Robinson equation of state using the Wong and Sandier mixing rules, and the relevant parameters are presented.

  • PDF

An Experimental Study on Spalling Reduction Methode of Polymer Modified Cement Mortar Using Fiber Cocktail (섬유혼입 공법을 이용한 폴리머 시멘트 모르타르의 폭렬저감방안에 관한 실험적 연구)

  • Kim, Ji-Hoon;Ryu, Dong-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.96-97
    • /
    • 2020
  • Polymer modified cement mortar (PCM) is commonly used as a repair material. However, in high-temperature environments such as fire, it is more likely to explode than cement mortar. The polymer is thermally decomposed at a high temperature to form a gas, and the gas remaining inside the structure increases the internal pressure to generate a burst. When an spalling occurs, the coating is peeled off and dropped, and high temperature is transmitted to the inside of the structure. In severe cases, even the reinforcing bar is exposed, which can lead to the collapse of the structural member due to severe loss of strength. In this study, in order to reduce spalling of PCM, a fiber mixing method was selected from the refractory method to find an appropriate blending ratio of fibers and polymers.

  • PDF

Effect of Recycled Coarse Aggregate (RCA) Replacement Level on the Bond Behaviour between RCA Concrete and Deformed Rebars (순환 굵은골재의 혼입률에 따른 콘크리트와 이형철근의 부착 거동)

  • Jang, Yong-Heon;Choi, Ki-Sun;You, Young-Chan;Kim, Keung-Hwan;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.123-130
    • /
    • 2010
  • In this study, mixed recycled coarse aggregate (RCA) was produced by mixing RCA from waste concrete in order to evaluate a new method of RCA production. Bond strength between reinforcing bars and RCA concrete was qualitatively evaluated as a part of continuous studies to establish design code of reinforced concrete structural members using recycled aggregate. For practical application, specimens were manufactured with the ready mix RCA concrete. Parameters investigated include: concrete compressive strength (i.e 21, 27 and 40 MPa), replacement levels (i.e 0, 30, 60 and 100%), bar position (i.e vertical and horizontal) and bar location (75 and 225 mm). For the pull-out test, each specimen was in the form of a cube, with each side of 150 mm in length and a deformed bar, 16 mm in diameter, was embedded in the center of each specimen. From the test results, the most of HT type specimen with compressive strength of 21 and 27 MPa showed lower bond strength than the ones provided in CEB-FIP and considered in reinforcement location factor ($\alpha\;=\;1.3$). It was reasoned that bonded area of top bar specimen was reduced at the soffit of reinforcement because of bleed water of fresh concrete. Therefore the reinforcement location factor in current KCI design code should be reviewed and modified.

Development of Nurserγ Soil for Rice Seedling (Phyllite를 이용한 수도용(水稻用) 육묘(育苗) 상토개발(床土開發))

  • Park, Young-Hee;Chang, Ki-Woon;Hong, Jei-Gu
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.10 no.2
    • /
    • pp.71-81
    • /
    • 2002
  • The study was carried out to develop nursery soil for rice seedling of phyllite. First of all, physico-chemical properties of used phyllite in the study through the analysis for agricultural utilization evaluation are as following. Bulk density(BD) of phyllite was $1.31g/cm^3$ each other and porosity had 65% of entire pore size. Also, the water holding capacity(WHC) was 43% at 1/3bar pressure, which phyllite has high WHC. According to, the results the experiments for nursery soil were conducted by mixing the materials such as phyllite, zeolite and hill soil. The mixing ratios were 30, 50, and 70% for zeolite and hill soil into phyllite. These mixed materials were packed in a box by adding 0, 1 and 2g of N-fertilizer. At seedling test, there were increases in the growth of shoot and root of rice for phyllite to zeolite and phyllite to hill soil, respectively. On the other hand, the length of leaf increased with increasing application rate of phyllite, while length and a number of root increased with increasing application rate of hill soil. The growth in the plots of phyllite to zeolite and phyllite to hill soil was better than in control plot. Finally, phyllite plot had efficient results when it compared with others and the study used with phyllite will have to more research and effort for agricultural useful material.

  • PDF

Development of Spherical Granule of Fermented Red Ginseng Extracts (발효홍삼농축액 구형과립 제조 기술 개발)

  • Shin, Myung-Gon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.7
    • /
    • pp.1064-1071
    • /
    • 2015
  • Viscous fermented red ginseng extracts were dried and coated using a fluidized bed coater to increase convenience and consumer acceptance. The methods for making spherical granules of fermented red ginseng extracts with increasing convenience were established by using indigestible dextrin. Spherical granules of fermented red ginseng extracts with increasing convenience were made by mixing indigestible dextrin at 40% (40% IDD), 50% (50% IDD), and 60% (60% IDD) versus the soluble solid content of fermented red ginseng extracts. Spherical granules of fermented red ginseng extracts showed less angle of repose than powder of fermented red ginseng extracts. This means that spherical granules of fermented red ginseng extracts had good fluency with increased convenience. The more indigestible dextrin showed higher yields. Although 50% IDD showed less yield than 60% IDD, 50% IDD was the best mixing ratio for making spherical granules of fermented red ginseng extracts, as fermented red ginseng extracts is known as a healthy food. The optimized operation conditions of the fluidized bed coater for making 50% IDD were feeding rate 0.54 mL/min, atomization air pressure 2.15 bar, and product temperature $83.03^{\circ}C$.

Discussion on the Current Mortar-bar Method (ASTM 0227-90) by Experimental Study (실험적 연구에 의한 현행 모르타르봉 시험법(ASTM C227-90)의 검토)

  • 정지곤;이동영;유신애;황형중
    • The Journal of Engineering Geology
    • /
    • v.6 no.3
    • /
    • pp.155-163
    • /
    • 1996
  • The current ASTM C227-90 is a prescription on the mortar-bar method. This recornrnends that mortar-bars should be made using a mixing ratio by weight of 675 grams aggregate to 300 grams cement, and their initial lengths should be measured in $24{\pm}2$ hours. This method emphasizes that the prepare sample mortar-bars and calculate expansion rates of them. This method requires constant G values (effective gauge lengths) of denominator in the calculation formula, which are fixed either at 10 inches or 250mm. This study, based on experimental approaches, reexamines the suggestions made by those two prescriptions above and important results are summarized in the following. 1. Not only alkali-aggregate reaction but also interaction of interstitial and gel water are responsible for expansion of mortar-bars. This requires partial modification of the current ASTM C227-90. 2. A mixing ratio by volume rather than by weight of aggregate to cement is recommendable for measuring the amount of expansion resulting from alkali-aggregate reaction and from interstitial water. 3. The method of when to measure initial lengths and how to calculate expansion rate suggested by ASThI C227-90 and Cl90-93a should partly be modified for more accurate results.

  • PDF

Fabrication and Stability of V/YSZ Cermet Membrane for Hydrogen Separation (수소 분리를 위한 V/YSZ cermet 분리막의 제조 및 안정성)

  • Jeon, Sung-Il;Park, Jung-Hoon;Lee, Sang-Jin;Choi, Soo-Hyun
    • Membrane Journal
    • /
    • v.20 no.1
    • /
    • pp.62-68
    • /
    • 2010
  • The powder mixture for fabricating the cermet membranes was prepared by mechanically mixing 60 vol.% vanadium with $Y_2O_3$-stabilized $ZrO_2$ (YSZ). The powder mixture was pressed into disks, which were then sintered in vacuum at $1600^{\circ}C$ for 2 h. As-sintered membrane was dense and mounted to a stainless steel ring with brazing filler. Hydrogen fluxes of V/YSZ membrane have been measured in the range of $200{\sim}350^{\circ}C$ with 100% $H_2$. The crack was formed in the both sides of membrane at $350^{\circ}C$ and pressure of 0.5 bar. During permeation experiment, vanadium of V/YSZ membrane reacted with hydrogen to form $V_2H$ which was the origin of crack formation.

Effect of Combustion Instability on Heat Transfer in a Subscale Thrust Chamber (연소불안정에 따른 축소형 연소기에서의 열전달 영향)

  • Ahn, Kyubok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3403-3409
    • /
    • 2014
  • Hot-firing tests were carried out using a mixing head with 19 swirl coaxial injectors and a combustion chamber with internal cooling channels. The propellants of liquid oxygen and kerosene(Jet A-1) were burned in a range of chamber pressures (59~82 bar) and mixture ratios (2.0~3.0). The temperature of water used as the cooling fluid was measured at the inlet and outlet of the cooling channels, and the heat flux was calculated. The aim of this study was to examine the effect of combustion instability on heat transfer in a subscale thrust chamber, and detect the temperature variation of cooling water. During several hot-firing tests, combustion instability was encountered which caused a 5~20% increase in heat flux. The peak heat flux took place in the initial stages of combustion instability.

Combustion Test Results of Regenerative Cooling Combustor for 30 tonf-class Liquid Rocket Engine (30톤급 액체로켓엔진 연소기 재생냉각 연소시험 결과)

  • Han, Yeoung-Min;Kim, Jong-Gyu;Lee, Kwang-Jin;Lim, Byoung-Jik;Ahn, Kyu-Bok;Kim, Mun-Ki;Seo, Seong-Hyeon;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.133-137
    • /
    • 2008
  • Results of combustion tests performed for a regenerative cooling combustor of a 30 tonf-class liquid rocket engine were described. The combustion chamber has chamber pressure of 60 bar, propellant mass flow rate of 89 kg/s, and nozzle expansion of 12. The combustion chamber is composed of mixing head, baffle injector, and regenerative cooling chamber. The hot firing tests were performed at design and off-design points. The test results show that the combustion characteristic velocity is in the range of 1738${\sim}$1751 m/sec and the specific impulse of the combustion chamber is in the range of 253${\sim}$270 sec. The peak of combustion characteristic velocity and specific impulse for this combustor is shown at mixture ratio of 2.35 and 2.5, respectively.

  • PDF