• Title/Summary/Keyword: Mixed Analysis

Search Result 4,787, Processing Time 0.036 seconds

Analysis of mixed convective laminar flow and heat transfer about a sphere (혼합대류에 의한 구 주위의 충류유동 및 열전달 해석)

  • 이준식;김택영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.345-353
    • /
    • 1987
  • An analysis is performed to study flow and heat transfer characteristics of mixed free and forced convection about a sphere. Nonsimilar boundary layer equations which are valid over the entire regime of mixed convection are derived in terms of the mixed convection parameter, Gr/Re$^{2}$, through a dimensional analysis. The transformed conservation equations are solved by a finite difference method for the whole range of mixed convection regime. Numerical results for fluids having the Prandtl number 0.7 and 7 are presented. As the mixed convection parameter increases, the local friction coefficient and local heat transfer coefficient increases as well. For small Prandtl number, the friction coefficient is larger, while for large Prandtl number, the heat transfer coefficient is larger. Natural convection effect on the forced flow is more sensitive for small Prandtl number fluid. Flow separation migrates rearward as an increase in the mixed convection parameter. For small Prandtl number, the buoyancy effect is relatively small so that the flow separation occurs earlier.

A Study of Choice for Analysis Method on Repeated Measures Clinical Data

  • Song, Jung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.45 no.2
    • /
    • pp.60-65
    • /
    • 2013
  • Data from repeated measurements are accomplished through repeatedly processing the same subject under different conditions and different points of view. The power of testing enhances the choice of pertinent analysis methods that agrees with the characteristics of data concerned and the situation involved. Along with the clinical example, this paper compares the analysis of the variance on ex-post tests, gain score analysis, analysis by mixed design and analysis of covariance employable for repeating measure. Comparing the analysis of variance on ex post test, and gain score analysis on correlations, leads to the fact that the latter enhances the power of the test and diminishes the variance of error terms. The concluded probability, identified that the gain score analysis and the mixed design on interaction between "between subjects factor" and "within subjects factor", are identical. The analysis of covariance, demonstrated better power of the test and smaller error terms than the gain score analysis. Research on four analysis method found that the analysis of covariance is the most appropriate in clinical data than two repeated test with high correlation and ex ante affects ex post.

  • PDF

SMOOTHING ANALYSIS IN MULTIGRID METHOD FOR THE LINEAR ELASTICITY FOR MIXED FORMULATION

  • KANG, KAB SEOK
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.5 no.1
    • /
    • pp.11-24
    • /
    • 2001
  • We introduce an assumption about smoothing operator for mixed formulations and show that convergence of Multigrid method for the mixed finite element formulation for the Linear Elasticity. And we show that Richardson and Kaczmarz smoothing satisfy this assumption.

  • PDF

Analysis of structured singular value with mixed sensitivity problem in robust performance (혼합된 감도함수를 이용한 구조적 특이치의 견실성능문제 분석)

  • 방경호;엄태호;박홍배
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.482-485
    • /
    • 1993
  • This paper deals with structured singular value and mixed sensitivity problem for robust performance. We derive the sufficient condition that mixed sensitivity problem satisfies structured singular value in robust performance problem. And we show the bound of perturbation between structured singular value and norm of mixed sensitivity functions.

  • PDF

A Study on the An Acade of Mixed-Use Building - Focused on the A user form of Mixed-Use Building - (주상복합 주거단지의 상가시설 실내계획에 관한 연구 - 주상복합 상가시설의 이용자 패턴을 중심으로 -)

  • Roh, Yeon-Soo;Lee, Hyen-Hee
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.11a
    • /
    • pp.165-169
    • /
    • 2006
  • Here this Study is purposed Importance of an arcade in Mixed - Use Building. Because Mixed - Use Building ha)'e problem In korea. So Solution the Community of Mixed - Use Building a Housing development. An Acade of Mixed-use Building have a good point that is carrier Space. The Process of this Study 1) A study on the Mixed-Use Building Form and a user form in theory. 2) Condolence about Mixed-used Building of three type in kyungki and seoul ( Lotte Castle In Jamsil Seoul, park view In SungNam kyungki, Dong- Yang Paragon in SungNam kyungki) 3) analysis by theory of Mixed-Use Building Form and a user form about Mixed-Use Building 4) As a result of as being Comparison three building develop.

  • PDF

Effect of Mixing Time of Pre-Mixed Cement and Post-Mixed Cement on the Strength Development of the Concrete (프리믹스 및 포스트믹스 시멘트를 혼입시간이 콘크리트의 압축강도에 미치는 영향)

  • Baek, Sung-Jin;Lee, Hyeok;Han, Jun-Hui;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.137-138
    • /
    • 2023
  • This study proposed the optimal mixing time for pre-mixed cement and post mixed cement using the statistical analysis method of box plots. Pre-mixed cement can prevent material seegregation, strength loss, and quality variation if mixed for at least 60 seconds, and the data median is shown to be within the box range. Post-mixed cement should be mixed for at least 180 seconds to prevent material segregation, strength loss, and quality variation, and compressive strength tends to increase with longer vibrating times. Therefore, it is suggested that using pre-mixed cement can shorten the vibrating time and increase the productivity of the concrete.

  • PDF

Free vibration analysis of Reissner plates by mixed finite element

  • Eratli, Nihal;Akoz, A. Yalcin
    • Structural Engineering and Mechanics
    • /
    • v.13 no.3
    • /
    • pp.277-298
    • /
    • 2002
  • In this study, free vibration analysis of Reissner plates on Pasternak foundation is carried out by mixed finite element method based on the G$\hat{a}$teaux differential. New boundary conditions are established for plates on Pasternak foundation. This method is developed and applied to numerous problems by Ak$\ddot{o}$z and his co-workers. In dynamic analysis, the problem reduces to the solution of a standard eigenvalue problem and the mixed element is based upon a consistent mass matrix formulation. The element has four nodes and bending and torsional moments, transverse shear forces, rotations and displacements are the basic unknowns. The element performance is assessed by comparison with numerical examples known from literature. Validity limits of Kirchhoff plate theory is tested by dynamic analysis. Shear locking effects are tested as far as $h/2a=10^{-6}$ and it is observed that REC32 is free from shear locking.

Nonlinear Behaviors of Mixed Structure Considering Advanced Connection Types (개선된 접합부 방식을 갖는 혼합구조의 비선형 거동)

  • Huh, Taik-Nyung;Yun, Ik-Jung;Kim, Mun-Kyum;Cho, Sung-Yong;Shim, Byul
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.677-682
    • /
    • 2007
  • Nonlinear analysis of mixed structures is carried out by utilizing contact elements of a general finite element analysis computer program(ABAQUS). The present analysis focuses on the enhancing behaviors of mixed structure's connection type. Main 2 issues are related with discontinuity which reduce the stiffness of structure and proposing enhanced connection type. To validate the present study approaching 2 way, analytic one and experimental test.

  • PDF

Analysis of biomarkers with tunable infrared gas sensors (가변 파장형 적외선 가스 센서에 의한 생체표지자 분석)

  • Yi, Seung Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.314-319
    • /
    • 2021
  • In this study, biomarkers were analyzed and segmented using tunable infrared gas sensors after performing the principal component analysis. The free spectral range of the device under test (DUT) was around 30 nm and DUT-5580 yielded the highest output voltage property among the others. The biomarkers (isoprophyl alcohol, ethanol, methanol, and acetone solutions) were sequentially mixed with deionized water and their mists were carried into the gas chamber using high-purity nitrogen gas. A total of 17 different mixed gases were tested with three tunable infrared gas sensors, namely DUT-3144, DUT-5580, and DUT-8010. DUT-8010 resolved the infrared absorption spectra of whole mixed gases. Based on the principal component analysis with each DUT and their combinations, each mixed gas and the trends in increasing gas concentration could be well analyzed when the contributions of the eigenvalues of the first and second were higher than 70% and 10%, respectively, and their sum was greater than 90%.

A Study on the Application building Scope for the Mixed-Use Districts (복합용도지역의 건축물 규모의 운용방안에 관한 연구)

  • Lee, Won-Geun;Kim, Young-Chan
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.10 no.1
    • /
    • pp.65-74
    • /
    • 2010
  • This study has been given careful consideration to an induction of the mixed-use districts for the efficiency of Land Use, the rational plot planning and the mixture/complex among the functions in order to complement the zoning plan with the primary purpose to purify the usage of landscape. Furthermore, it is aimed to indicate the implementations through the medium of the in-depth analysis about the cardinal factors such as the standards on the regional location, building size and building uses in the case of designating the Mixed-use districts.Abstract This study has been examined by the aspect of scope for securing the adequacy of Site Division Restriction, Floor Area Ratio, Building Coverage Ratio and Outdoor Area Ratio in the "Mixed-Use Districts" and especially, by the medium of the in-depth analysis about the actual condition of building and outdoor space scales. It has been deduced the scale standards by using the simulation and correlation analysis among the factors of those buildings and outdoor spaces. Moreover, it has been applied the analysis method of using the building scale, especially, the latter has analyzed the total 1,656 different types classified by 3 patterns of Plottage and Building Coverage Ratio, 9 patterns of the factor change on Outdoor Area Ratio and 8 different patterns of road width.