• Title/Summary/Keyword: Mix proportion method

Search Result 81, Processing Time 0.021 seconds

Optimal Mixture Proportion for High Performance Concrete Incorporating Ground Granulated Blast furnace Slag

  • Choi Jae-Jin;Kim Eun-Kyum;Yoo Jung-Hoon
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.3 s.87
    • /
    • pp.473-480
    • /
    • 2005
  • In this study, a mix design for self compacting concrete was based on Okamura's method and concrete incorporated just a ground granulated blast furnace slag. Replacement ratio of slag is in the range of $20-80\%$ of cement matrix by volume. For the optimal self compactability in mixture incorporating ground granulated blast furnace slag, the paste and mortar tests were first completed. Then the slump flow, elapsed time of 500mm slump flow, V funnel time and filling height by U type box were conducted in concrete. The volume of coarse aggregate in self compacting concrete was in the range of $50-60\%$ to the solid volume percentage of coarse aggregate. Finally, the compressive and splitting tensile strengths were determined in the hardened self compacting concrete incorporating ground granulated blast furnace slag. From the test results, it is desirable for self compacting concrete that the replacement of ground granulated blast furnace slag is in the range of $40-60\%$ of cement matrix by volume and the volume of coarse aggregate to the solid volume percentage of coarse aggregate with a limit of $55\%$.

Correlation between Mix Proportion and Mechanical Characteristics of Steel Fiber Reinforced Concrete (강섬유 보강 콘크리트의 배합비와 역학적 특성 사이의 관계 추정)

  • Choi, Hyun-Ki;Bae, Baek-Il;Koo, Hae-Shik
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.331-341
    • /
    • 2015
  • The main purpose of this study is reducing the cost and effort for characterization of tensile strength of fiber reinforced concrete, in order to use in structural design. For this purpose, in this study, test for fiber reinforced concrete was carried out. Because fiber reinforced concrete is consisted of diverse material, it is hard to define the correlation between mix proportions and strength. Therefore, compressive strength test and tensile strength test were carried out for the range of smaller than 100 MPa of compressive strength and 0.25~1% of steel fiber volume fraction. as a results of test, two types of tensile strength were highly affected by compressive strength of concrete. However, increase rate of tensile strength was decreased with increase of compressive strength. Increase rate of tensile strength was decreased with increase of fiber volume fraction. Database was constructed using previous research data. Because estimation equations for tensile strength of fiber reinforced concrete should be multiple variable function, linear regression is hard to apply. Therefore, in this study, we decided to use the ANN(Artificial Neural Network). ANN was constructed using multiple layer perceptron architecture. Sigmoid function was used as transfer function and back propagation training method was used. As a results of prediction using artificial neural network, predicted values of test data and previous research which was randomly selected were well agreed with each other. And the main effective parameters are water-cement ratio and fiber volume fraction.

Quality Evaluation and Mix Proportion of Antiwashout Underwater Concrete with Mineral Admixture (광물질 혼화재료를 사용한 수중불분리성 콘크리트의 배합 및 품질평가 방안 검토)

  • Park, Yong Kyu;Kim, Hyun Woo;Yoon, Ki Woon
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.679-686
    • /
    • 2014
  • In this research, the mix proportion of the antiwashout underwater concrete with the mineral admixture was evaluated. It can reduce the amount used of the antiwashout admixture (hereinafter referred to as "AWA") and satisfy the properties of concrete. In addition, the review for the difference of the test and practical affairs were conducted. Optimized unit quantity of water of antiwashout underwater concrete and the amount used of AWA was revealed by $190kg/m^3$, 0.9%/W, respectively. In particularly, the mix design is reduced by 5% than the W/B of target strength even though the W and AWA reduced. Therefore, it will have the economical feasibility and qualities including the material separation, resistance characteristic and compressive strength, and etc. The stable value was shown in 1 point of minute passed in the measurement of the turbidity amounts using the turbidimeter after the checker insertion. However, it needs to be reviewed for the interrelationship between turbidity measuring machine and KCI-AD102 standard method. There were no significant differences of compressive strength of specimens in the water depending on the production methods.

Evaluation of the Genetic Toxicity of Cyclopentane and Ammonium Nitrate - In vitro Mammalian Chromosomal Aberration Assay in Chinese Hamster Ovary Cells

  • Kim, Soo-Jin;Rim, Kyung-Taek;Kim, Jong-Kyu;Kim, Hyeon-Yeong;Yang, Jeong-Sun
    • Safety and Health at Work
    • /
    • v.2 no.1
    • /
    • pp.17-25
    • /
    • 2011
  • Objectives: In this study, the in vitro mammalian chromosomal aberration (CA) assay was conducted to gain additional information concerning the hazards associated with the use of cyclopentane and ammonium nitrate. While these two chemicals had already been tested by many methods, they had not been studied in the CA test. Methods: The assay was performed using the ovarian infantile cell (CHO-K1 cell), by the direct method (-S9) and by the metabolic activated method (+S9 mix). Results: Using the direct method, the 7 dosages in a 48 hour treatment group did not show that the frequency of CA is proportion to the dosage addition. The frequency of CA is not proportion to the dosage addition for a 6 hour treatment using the metabolic activated method. Conclusion: From these findings, it was decided that the 2 chemicals do not induce chromosomal aberrations under the tested conditions.

The Study on Evaluation of percentage of water content using electric resistivity and dielectric constant (전기저항 및 유전율을 이용한 모래의 함수율 측정에 관한 연구)

  • 김화중;박정민;김태곤;최신호;이승조
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.118-123
    • /
    • 1995
  • Evaluating the moisture content for sand is useful for quality cotnrol of concrete. If water content of evaluate instantly and apply for mix proportion sand of concrete, in mixing propertion of concrete, it can makes to improve of concrete quality. In this study, the evaluating method for moisture content of sand, using the electric velocity and dielectric constant was proposed as a study of quality control of concrete. The obtained results are summarized as follow. The resistance ratio was decreased as the increase of moisture content The dielectric constant was decreased as the sand of the moisture content increase.

  • PDF

A Study on the Construction Method for the Thermal Crack Control of Underground Box Structure (지하박스구조물 온도균열제어를 위한 시공방안연구)

  • 오병환;유성원;김의성;전세진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.205-210
    • /
    • 1998
  • The strength and dimension of recent constructed subway box structures are increased considerably. These increases are resulting in much initial cracks by hydration heat and thermal stress. According to previous studies, decrease of cement amount by using superplasticizer and L/H value is the best way to eliminate hydration heat and stress. The analyses using finite element model were performed. By the result of analysis, the use of superplasticizer and the decrease of the change of longitudinal placing length are proved to be more effective for elimination thermal cracks. By ACI Code, for longitudinal placing length 25 m, the amount of wall temperature reinforcement is always lack despite of concrete mix proportion. With analytical result and the inducing crack joint, the in-site test were performed and the analytical results proved to be effective. However, the inducing crack joint is not effective if it is a small size.

  • PDF

유동화 공법에 의한 제치장 콘크리트의 현장실험 연구

  • Han, Cheon-Gu;Jeon, Chung-Geun
    • 레미콘
    • /
    • no.7 s.68
    • /
    • pp.9-16
    • /
    • 2001
  • Execution of exposed concrete has some problems such as segregation, surface honey comb and insufficient surface flossing due to unsuitable mix proportion and unfavorable construction in our field. Therefore, in this paper, field application of exposed concrete at training center building of Chongju university in Daecheon are carried out based on the mixing data obtained from laboratory test. Base concrete are made in accordance with mixing data. Segregation reducing type superplasticizer developed are applied in order to flow the vase concrete with out segregation of materials. According to test results, air content shows to be reduced after flowing. Compressive strength of flowing concrete is higher than that of base concrete about 7%. Surface glossing is reducing as the age goes on. It is improved about 10% compared to that of vase concrete.

  • PDF

Development of manufacturing technology of Artificial Reef Mixed with Reclamation Coal Ash (매립석탄회를 활용한 인공어초 제조기술 개발)

  • Han Sang-Mook;Cho Myoung-Suk;Song Young-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.125-128
    • /
    • 2005
  • Coal ash, which is generated as a byproduct at a coal thermal power plant, can be classified into fly ash and bottom ash. Most of fly ash is recycled as an admixture for concrete, while bottom ash is not recycled but dumped into an ash landfill disposal site. So, if a technology for recycling bottom ash efficiently, which is increasingly generated year by year, is not developed, environmental problems will take place as a matter course and further an enormous economical cost will be required for construction of additional ash landfill disposal sites. In this study an optimum mix proportion design and a quality control method for utilizing the reclamation coal ash as an aggregate for secondary concrete products such as an artificial reef was successfully developed.

  • PDF

Development of manufacturing technology of Wave Dissipating Block with industrial byproduct (산업부산물을 활용한 소파블럭 제조기술 개발)

  • Han Sang-Mook;Cho Myoung-Suk;Song Young-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.129-132
    • /
    • 2005
  • Reclamation coal ash, which is generated as a byproduct at a coal thermal power plant is not recycled but dumped into an ash landfill disposal site. Furthermore, various byproducts and wastes have been proposed for use from the point of reduction in the environmental load. Authors have started research to develope manufacturing technology of concrete mixture design method with large amount of land reclamation coal ash. In this study an optimum mix proportion design for utilizing the reclamation coal ash and containing copper slags as an aggregate for secondary concrete products such as a wave dissipating blocks was successfully developed.

  • PDF

A Study on Qualities and Components of Wax Patterns (납형의 성질(性質) 및 성분(成分)에 관(關)한 연구(硏究))

  • Kim, Myeong-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.2 no.1
    • /
    • pp.17-19
    • /
    • 1980
  • This study was aimed at obtaining a desirable wax pattern for inlay. The method used was to analyze, mix, and heat several kinds of waxes, comparing the temperatures of their components. The result was Type C wax. In type C the amount of paraffin was generally contained(60$\sim$70%) was reduced to 45% and there was mixed 10%-15% of carnauba, which was intended for the wax not to soften readily at low temperatures. The type C has some advantages for general use: handy preparation, high safety, and economy. The inlay waxes commonly used contracted if the temperature fell from 38 to 28, but the contraction of type C was observed to be 0.2%$\sim$0.4% in proportion to the 10 fall. This was more characteristic in mixing.

  • PDF