• Title/Summary/Keyword: Minimum radiation dose

Search Result 181, Processing Time 0.025 seconds

Influence of Statistical Compilation of Meteorological Data on Short-Term Atmospheric Dispersion Factors in a Hypothetical Accidental Release of Nuclear Power Plants (기상자료의 통계처리방법이 원자력발전소의 가상 사고시 단기 대기확산인자에 미치는 영향)

  • Hwang, Won-Tae;Kim, Eun-Han;Jeong, Hae-Sun;Jeong, Hyo-Joon;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.3
    • /
    • pp.116-122
    • /
    • 2012
  • A short-term atmospheric dispersion factor (${\chi}/Q$) is an essential element for radiological dose assessment following a hypothetical accidental releases of light-water nuclear power plants. The U. S. NRC developed PAVAN program to comply with the U. S. NRC's Regulatory Guide 1.145. Meteorological data is an essential element for atmospheric dispersion, and PAVAN uses a joint frequency distribution data, which represents the occurrence probability of wind speed and wind direction for atmospheric stability. Using the meteorological data measured at Kori and Wolsung sites for the last 5 years (from 2006 to 2010), a variety of joint frequency distribution data were prepared to evaluate ${\chi}/Q$ values with different wind speed classifications (U. S. NRC's recommendation and even distribution of occurrence probability) and periods of meteorological data to be analyzed (1 year, 2 year, 3 year, 4 year, 5 year). As a result, it was found that the influence of the wind speed classification on ${\chi}/Q$ values is little, while the influence of the periods of meteorological data to be analyzed is relatively significant, representing more than 1.5 times in the ratio of maximum to minimum values.

Analysis of the cause by Pre Exposure Tube Voltage and Actual Exposure Tube Voltage deviation in Mammography Examination (유방 촬영검사에서 사전조사 관전압과 실제조사 관전압 편차에 따른 원인 분석)

  • Cho, Ji-Hwan;Lee, Hyo-Yeong;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.2
    • /
    • pp.79-85
    • /
    • 2017
  • The purpose of this study is to investigate the cause analysis according to the difference between the pre exposure tube voltage and actual exposure tube voltage in mammography in connection with breast pressure thickness, breast size and body mass index and to find the improvement. The study tracked 377 women age 40 and older among the mammography examiners conducted by the National Health Insurance Corporation. It was analyzed that breast pressure thickness, breast size and body mass index according to the difference between the pre exposure tube voltage and actual exposure tube voltage among the parameters of dose report been sent to the picture archiving communication system with reference to the image with cranio-caudal projection in mammography. As are result, it shows that the thicker the breast thickness, smaller the breast size and lower body mass index, the higher the difference of tube voltage. In conclusion, the minimum tube voltage of mammography machine should be reset in order to set the tube voltage according to breast pressure thickness and breast size that are suitable for our country in mammography, in addition, it was considered that radiologist should make an effort to reduce radiation exposure and make a good quality image with reducing the difference of mammography condition by making a correct exposure condition in case of examining the patients with thin breast pressure and small breast size.

THE CHANGE OF SALIVARY FLOW RATE, AND CONCENTRATION OF TOTAL PROTEIN AND IGA AFTER RADIATION THERAPY OF ORAL CANCER (구강암 환자에서 방사선 조사에 따른 타액량, 총 단백 및 IgA 농도의 변화)

  • Lee, Jong-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.3
    • /
    • pp.249-256
    • /
    • 1999
  • This study was performed to investigate the changes in flow and composition of saliva in oral cancer patients after radiation therapy. Stimulated whole saliva was collected from 7 patients who were scheduled for over 6,000cGy irradiation (180 - 225cGy fraction $Co^{60}$ therapy, 5 times a week). The flow rate of saliva, and concentration of total protein and IgA were measured before irradiation and 1, 2, 3, 4, 5 days and 1, 2, 3, 4, 6 weeks and 3, 6, 12 months after. The followings are results we obtained: 1. The salivary flow rate before irradiation was $0.8671{\pm}0.4057ml/min$. Significant decrease started 3 days after irradiation and reached a minimum at 4 weeks ($0.2621{\pm}0.2858ml/min$). Afterwards, flow rate started to increase and was on the way to recover at 1 year. 2. The concentration of total protein and IgA before irradiation were $137.2000{\pm}16.9912mg%$ and $3.4200{\pm}1.4114mg%$, respectively. After irradiation, these figures increased significantly and reached a maximum of $366.4000{\pm}174.0583mg%$ and $43.4800{\pm}29.1207mg/ml$, respectively at 6 weeks. Recovery towards normal values started following the end of irradiation and figures at 12 months had lowered to $165.400{\pm}21.1495mg%$ and $4.6200{\pm}2.1580mg/ml$ each. 3. The ratio of IgA to the amount of total protein was 2.5% before irradiation. This began to increase from 1 week following irradiation as the total dose of radiation received was increased (11.9% at 6 weeks). After 1 year from the start of radiation therapy, the ratio was reduced to such level that was before irradiation.

  • PDF

The Result of Radiotherapy in Esophageal Carcinoma (식도암의 방사선치료 성적)

  • Gil Hack Joon;Kay Chul Seung;Jang Jee Young;Yoon Sei Chul;Shinn Kyung Sub;Bahk Yong Whee
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.193-204
    • /
    • 1992
  • During the period between March 1983 and December 1990, 74 patients with esophageal carcinoma (EG) were treated with radiation therapy (RT) at the Department of Therapeutic Radiology, Kangnam St. Mary's Hospital, Catholic University Medical College. Of these, 6 patients were lost to follow-up, and 13 patients were interrupted. So the remaining 55 patients were analyzed, retrospectively. 32 patients were irradiated with curative aim, 12 patients with palliative intent, 10 patients postoperatively, and 1 patient pre- and post-operatively. Among these 55 patients, 28 patients were treated with chemoradiation modality, and 27 patients with RT alone. All patients were followed for a minimum of 20 months or until death. Of 32 patients irradiated by curative aim, 22 patients (69%) showed partial remission (PR), 6 patients (19%) complete remission (CR). Overall mean survival and two-year survival rate were 15.6 months and 22%. With respect to sex, age, pathologic differentiation, tumor location, tumor size, stage, RT aim, RT response, RT dose, use of chemotherapy and functional categories (FC) of dysphagia at initiation of RT and at finishing RT: Tumor size, stage, RT response had great influences on prognosis and FC at finishing RT had a slight influence on prognosis. Especially, the mean survival and 2-year survival rate in patients with postoperative RT were 24.7 months and 63%, which could be compared with 29.1 months and 43% in radically treated patients with CR. And the mean survival duration and 2-year survival rate in patients irradiated with doses more than 60 Gy were 22.4 months and 29%, and 50~60 Gy were 12.2 months and 12%, respectively. However, no significant difference was shown statistically. Among 12 patients treated with palliative intent, 9 patients (75%) had good improvement in dysphagia and the mean duration of palliative response was 10.6 months.

  • PDF

Adjuvant Radiotherapy Following Radical Hysterectomy and Bilateral Pelvic Lymph Node Dissection for the Uterine Cervical Cancer : Prognostic Factors and Failure Patterns (근칙적 절제술과 술후 방사선치료를 시행한 자궁경부암 환자의 치료성적, 예루인자와 실패양상)

  • Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.357-367
    • /
    • 1997
  • Purpose : To identify variable prognostic factors and analyse failure patterns in the uterine cervix cancer after radical operation and adjuvant radio-therapy, a retrospective analysis was undertaken. Materals and Methods : I analysed one hundred and twenty four patients with uterine cervix cancer, FIGO stage IB, IIA and IIB, treated with radical hysterectomy and pelvic lymph node dissection followed by adjuvant radio-therapy between May 1985 and May 1994. Minimum follow up period was 24 months. All of them were treated with full dose external radiotherapy with linear accelerator and/or high dese rate intracavitary radiation. Results : Overall 5 year survival rate and relapse free survival rate were $75.4\%,\;73.5\%$, respectively. Significant prognostic factors by relapse free survival were wall involvement thickness, lymph node location and number, parametrium involvement, tumor size, stage, uterine body involvement, vaginal resection margin involvement. By multivariate analysis, lymph node matastasis. tumor size and vaginal resection margin involvement were significant prognostic factos. Treatment related failure were 33 cases. Locoregional failure were more likely in the stage IIB, lymph node positive or vaginal resection margin positive patients whereas distant failures were relatively more frequent in stage IB, IIA and lymph node, vaginal resection negative patients. In stage IIB, 5 year relapse free survival rate was only $56\%$ and nine of twenty two patients recurred. Conculsion : Postoperative radiotherapy results are good for patients with relatively low risk factor. But the results are poor for patients with multiple, high risk factors or stage IIB. To control recurrence for patients with high risk factors, postoperative adjuvant radiotherapy is not sufficient treatment method. To raise control rate adding other methods such as radiosensitizing agent or chemotherapy is necessary and prospectively randomized study is needed for evaluation of postoperative radiotherapy efficacy and /or other methods. And it is reasonable to treat primary radical radiotherapy for patients with stage IIB cervical cancer instead of radical operation and adjuvant radiotherapy and/or chemotherapy regimen.

  • PDF

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

Comparison of Lung Ventilation Scan Using Technegas and $^{99m}Tc-DTPA$ Aerosol (Technegas 환기스캔과 $^{99m}Tc-DTPA$ Aerosol 스캔의 비교)

  • Choi, Yoon-Ho;Kim, Sang-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Keun-Youl;Koh, Chang-Soon;Koong, Sung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.2
    • /
    • pp.237-243
    • /
    • 1990
  • Pulmonary embolism demands rapid and accurate diagnosis. And ventilation imaging has greatly improved the diagnostic accuracy of pulmonary embolism in addition to perfusion imaging. Agents currently used include xenon-133, krypton-81m and technetium-99m radioaerosols. However radioactive gases are compromised by availability and cost for krypton-81m, radiation dose, gamma energy and non?physiologic behaviour for xenon-133. Radioaerosols of technetium-99m componds are rapidly cleared from the lung after inhalation, and their relative low effeciency (specific radioactivity) and wide distribution of particle sizes make them also suboptimum. A new ventilation agent, Technegas is a suspension of structured graphite ellipsoids with diameter below 20nm, labelled with $^{99m}Tc$ in a carrier gas of Argon. This report describes the authors' clinical experience with Technegas. This is the first reported clinical study of this agent in Korea. A comparison of Technegas and $^{99m}Tc-DTPA$ aerosol was performed in 12 patients with various pulmonary diseases such as COPD, pulmonary tuberculosis and pleural effusion. All patients were studied with $^{99m}Tc-DTPA$ aerosol inhalation and Technegas ventilation. In both studies image quality was assessed (1) semiquantitatively by scoring bronchial and gastric activity, (2) subjectively by direct visual comparison of peripheral lung images and (3) quantitatively by computing the peripheral penetration index(PI) for each lungs. The bronchial activites were seen in 7 out of 12 cases with $^{99m}Tc-DTPA$ aerosol and in 5/12 with Technegas. The gastric activities were seen in 5/12 and 1/12 cases respectively. The average values of PI were 61.26% with $^{99m}Tc-DTPA$ aerosol and 69.20% with Technegas (p>0.05). Using $^{99m}Tc-DTPA$ aerosol, COPD patients showed deposition in the central airways with poor visualization of the peripheral areas of the lungs. In Technegas studies these phenomena were less prominent, and the examination is well tolerated by pateients and requires only a minimum of patient cooperation. With superiority of easy availability and handling, better physical characteristics and favorable Image quality, Technegas is a Promising agent for lung ventilation scanning.

  • PDF

Antioxidant, Antimicrobial and Cytoprotective Effects of the Extract and Its Fraction Obtained from Rhizomes of Belamcanda chinensis (L.) DC (범부채 뿌리 추출물 및 분획물의 항산화, 항균 및 세포 보호 효과)

  • Song, Ba Reum;Lee, Sang Lae;Lee, Yun Ju;Shin, Hyuk Soo;Park, Soo Nam
    • Applied Chemistry for Engineering
    • /
    • v.29 no.6
    • /
    • pp.772-781
    • /
    • 2018
  • In this study, we investigated antioxidant, antimicrobial and cytoprotective effects of 50% ethanol extract and ethyl acetate fraction from rhizomes of Belamcanda chinensis (L.) DC. 1,1-Diphenyl-2-picrylhydrazyl (DPPH) free radical scavenging activities ($FSC_{50}$) of the 50% ethanol extract and ethyl acetate fraction were 621.5 and $253.0{\mu}g/mL$, respectively. Total antioxidant capacities ($OSC_{50}$) of the extract and fraction were 13.6 and $3.0{\mu}g/mL$, respectively. Minimum inhibitory concentrations (MIC) of the ethyl acetate fraction for Staphylococcus aureus and Candida albicans were 156, $1,250{\mu}g/mL$, respectively, indicating similar or higher levels of those of using methyl paraben. Cytoprotective effects of the 50% ethanol extract against $^1O_2$-induced cellular damage (${\tau}_{50}$) showed in a dose dependent manner at 4 to $64{\mu}g/mL$. ${\tau}_{50}$ of the 50% ethanol extract, ethyl acetate fraction and (+)-${\alpha}$-tocopherol at $16{\mu}g/mL$ were 36.4, 45.0 and 45.8 min respectively, and the ethyl acetate fraction showed cytoprotective effects similar to (+)-${\alpha}$-tocopherol. In ultraviolet B radiation-induced HaCaT cell damage, the ethyl acetate fraction decreased intracellular reactive oxygen species (ROS) up to 45.9% at $8{\mu}g/mL$. Also in $H_2O_2$-induced HaCaT cell damage, the ethyl acetate fraction significantly increased the cell viability at $0.5{\sim}8.0{\mu}g/mL$. As a result of chemical analyses of the ethyl acetate fraction, the presence of flavonoids and polyphenol such as irisflorentin, irigenin, tectorigenin, resveratrol, iridin and tectoridin were identified. In conclusion, the extract/fraction from rhizomes of B. chinensis can be applied as a natural antioxidant and antimicrobial material to cosmetics.

Radurization Effect of Korean Mackerel (한국산 고등어의 방사선 조사효과)

  • CHO S. J.;CHOE Y. K.;LEE S. Y.;BYUN S. M.;CHUNG J. R.
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.3
    • /
    • pp.219-226
    • /
    • 1985
  • To investigate potential application of radurization technique as an effective tool for controlling histamine accumulation, histamine contents were determined in fresh Korean mackerel meat samples irradiated at six dose levels of gamma radiation up to 1 Mrad during 35 day-storage at $0^{\circ},\;5^{\circ}\;and\;10^{\circ}C$. Total bacterial counts, total volatile bases and trimethylamine contents were also estimated. The minimum and maximum doses for Korean mackerel were determined to be 0.2 and 0.5 Mrad, respectively. Irradiation induced redening of fish muscle tissue and redening appeared to be dose dependent. At low doses, this redening contributed positively to the overall sensory qualities. At 0.5 and 1.0 Mrad, on the other hand, meat samples were excessively redened to the extent that red and white muscle layers were not readily distinguishable. No appreciable histamine accumulation occured during entire 35 day-storage in fresh mackerel meats, whether irradiated or not, when they were kept at ice temperature. At $5^{\circ}C$, histamine started to accumulate slightly during late storage in the samples irradiated at low doses. Even in the unirradiated samples, the histamine accumulation did not exceed the level of 10.0 mg per 100g meat until the 28th day at $5^{\circ}C$. At $10^{\circ}C$, however, histamine accumulation in the unirradiated was phenomenal from very early storage and the values reached 827.5 mg per 100g meat by the 35th day, while histamine accumulation in the irradiated was severely suppressed. Irradiation invariably brought about a significant reduction of initial microflora, disrupting normal spoilage pattern. This was reflected in the suppression of not only histamine but also total volatile bases and trimethylamine accumulation during post-irradiation storage at refrigerated temperatures.

  • PDF

Report on the External Audits Conducted by Korean Society of Medical Physics (한국의학물리학회 선형가속기 외부 품질관리 실시 현황보고)

  • Huh, Hyun Do;Cho, Kwang Hwan;Cho, Sam Ju;Choi, Sang Hyoun;Kim, Dong Wook;Hwang, Ui-Jung;Kim, Ki Hwan;Min, Chul Kee;Choi, Tae Jin;Oh, Young Kee;Lee, Seoung Jun;Park, Dahl;Park, Sung-Kwang;Ji, Young Hoon
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.315-322
    • /
    • 2013
  • The aim of this work is to verify the self-quality assurances in medical institutions in Korea through the external audits by the group of experts and have a mutual discussion of the systematic problems. In order to validate the external audits 30 of 80 medical institutions across the nation were picked out considering the regional distribution and the final 25 institutions applied voluntarily to take part in this work. The basic rules were setup that any information of the participants be kept secrete and the measurements be performed with the dosimetry system already verified through intercomparision. The outputs for 2 or more photon beams, the accuracy of gantry rotation and collimator rotation and the poistional accuracy of MLC movement were measured. The findings for the output measurement showed the differences of -0.8%~4.5%, -0.79%~3.01%, and -0.7%~0.07% with respect to that of the verified dosimetry system for the 6MV, 10MV, and 15MV, respectively. For the reference absorbed dose 8 (16%) of 50 photon beams in 25 medical institutions differed 2.0% or greater from the reference value. The coincidences of Field size with x-ray beam and radiation isocenters of Gantry roration and collimator rotation gave the results of within ${\pm}2$ mm for every institute except 2 institutions. The positional accuracy of MLC movement agreed to within ${\pm}1$ mm for every institute. For the beam qualities of 6 MV photon beams kQ values showed the distribution within 0.4% between maximum and minimum. For the protocols 21 institutions (84%) used absorbed dose to water based protocol while 4 insitutions (16%) used air kerma based one. 22 institutions employed the SSD technique while 3 institutions did the SAD one. External audit plays an important role in discovering the systematic problems of self-performing Quality Assurances and having in depth discussion for mutual complementation. Training experts of international level as well as national support system are required so that both the group of experts of medical physicists and government laboratory could perform together periodical and constant external audits.