• 제목/요약/키워드: Microtensile test

검색결과 70건 처리시간 0.02초

Microtensile bond strength and micromorphologic analysis of surface-treated resin nanoceramics

  • Park, Joon-Ho;Choi, Yu-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.275-284
    • /
    • 2016
  • PURPOSE. The aim of this study was to evaluate the influence of different surface treatment methods on the microtensile bond strength of resin cement to resin nanoceramic (RNC). MATERIALS AND METHODS. RNC onlays (Lava Ultimate) (n=30) were treated using air abrasion with and without a universal adhesive, or HF etching followed by a universal adhesive with and without a silane coupling agent, or tribological silica coating with and without a universal adhesive, and divided into 6 groups. Onlays were luted with resin cement to dentin surfaces. A microtensile bond strength test was performed and evaluated by one-way ANOVA and Tukey HSD test (${\alpha}$=.05). A nanoscratch test, field emission scanning electron microscopy, and energy dispersive X-ray spectroscopy were used for micromorphologic analysis (${\alpha}$=.05). The roughness and elemental proportion were evaluated by Kruskal-Wallis test and Mann-Whitney U test. RESULTS. Tribological silica coating showed the highest roughness, followed by air abrasion and HF etching. After HF etching, the RNC surface presented a decrease in oxygen, silicon, and zirconium ratio with increasing carbon ratio. Air abrasion with universal adhesive showed the highest bond strength followed by tribological silica coating with universal adhesive. HF etching with universal adhesive showed the lowest bond strength. CONCLUSION. An improved understanding of the effect of surface treatment of RNC could enhance the durability of resin bonding when used for indirect restorations. When using RNC for restoration, effective and systemic surface roughening methods and an appropriate adhesive are required.

수리된 복합 레진 수복물의 파괴 거동에 관한 연구 (The study of fractural behavior of repaired composite)

  • 박상순;남욱;엄아향;김덕수;최기운;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제35권6호
    • /
    • pp.461-472
    • /
    • 2010
  • 연구목적: 본 연구는 미세인장결합강도와 파괴인성을 통해 복합 레진 수복물의 수리 시기와 표면 처리 방법에 따른 파괴 거동을 알아보고자 시행되었다. 연구 재료 및 방법: Short rod 시편과 composite resin specimen block을 준비하여 표면 처리 방법에 따라 none-treated, sand blasting, bur roughening 군으로 나누고 이를 다시 즉시군과 2주 지연군으로 나누어 수리했다. 결과: 미세인장결합강도와 파괴인성을 측정한 결과, 두 실험 모두에서 즉시군이 지연군보다 높은 값을 보였다. 기계적 표면 처리군이 none-treated군보다 높은 값을 보였고, sand blasting과 bur roughening 사이에 유의한 차이는 없었다. 파괴인성과 미세인장결합강도는 상관 관계가 없었다. FE-SEM을 보아 수복물의 탈락은 균열 전도와 관계가 있는 것으로 보인다. 결론: 수리된 복합 레진의 파괴 거동 평가에는 파괴인성 실험이 적합하다.

상아질-복합레진 접착계면의 파괴거동에 대한 연구 (A STUDY ON FRACTURAL BEHAVIOR OF DENTIN-RESIN INTERFACE)

  • 류길주;최기운;박상진;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제32권3호
    • /
    • pp.208-221
    • /
    • 2007
  • 파괴 인성 실험은 상아질-복합레진 계면의 파절 저항성을 평가할 수 있는 임상적으로 신뢰 할 만한 방법이다. 본 연구의 목적은 상아질-레진 계면의 파괴인성과 미세인장결합강도를 측정하여 이 두 실험방법이 상아질-레진 결합을 평가하는 데 가지는 유용성을 비교, 평가하는 것이다 파괴 인성 측정에는 short-rod 시편 형태를 이용하였다. 각 시편에서는 소의 하악절치에서 절단한 치아 절편을 포함시켜 결합면을 얻었다. 미세인장 결합강도 또한 소의 하악절치 순면을 연마하여 상아질을 노출시킨 후 상아질 접착제를 도포하고 레진 블록을 축조하여 측정하였다. 각 시편들은 $37^{\circ}C$ 증류수에 24시간 보관한 후 각 실험방법에 맞게 인장력을 가하여 측정치를 구하였다. 통계분석은 95% 신뢰수준의 ANOVA와 Tukey's test를 이용하였으며, 두 실험방법의 상관관계를 보기 위해 Pearson's 상관계수를 계산하였다. 전자현미경 검사를 통해 미세구조 또한 관찰하여 다음과 같은 결론을 얻었다. 1. 파괴인성은 SE군이 가장 높은 값을 나타냈으며, Adper Single Bond 2 (SB), OptiBond Solo (OB) ONE-STEP PLUS (OS), ScotchBond Multi-purpose (SM)군 순으로 나타났고, Clearfil SE Bond (SE)군은 다른 실험군에 비해 유의하게 높은 값을 나타내었으나 (p <0.05), 다른 실험군 사이에는 유의차가 없었다 (p > 0.05). 2. 미세인장결합강도는 SE군이 가장 높은 값을 나타냈으며, SB, OB, SM, 그리고 OS 순으로 나타났다. SB, OB, SM, SE군 사이에는 통계학적인 유의차가 없었으나 (p > 0.05), OS군의 미세인장결합강도는 다른 4개의 실험군에 비해 낮은 값을 나타내었다 (p < 0.05). 3. FE-SEM관찰에서 피막도가 두껍게 나타난 SM군, SE군과 피막도가 얇은 OS군, OB군, SB군 간에 파괴양상이 다르게 나타났다 즉 전자는 접착층 내 파괴가 일어난 반면, 후자는 resin tag나 레진 침투층 내에서 파절되는 양상을 나타내었다. 4. 파괴 인성과 미세인장결합강도 사이에는 통계학적으로 유의 한 상관 관계가 없었다 ($r^2=0.223$, t=0.927). 이와 같은 결과를 토대로, 상아질 접착제의 임상적 효율성을 평가하고자 할 때는 결합강도 뿐만 아니라. 파괴인성도 함께 고려하여 임상적용의 예견성을 높여야 한다고 결론내릴 수 있다.

상아질의 봉쇄 시기와 표면처리 방법이 미세인장 결합강도에 미치는 영향 (Influence of air abrasion and different dentin sealing techniques on microtensile bond strength to dentin)

  • 강동호;한종현;박정원;김선재
    • 대한치과보철학회지
    • /
    • 제48권1호
    • /
    • pp.8-15
    • /
    • 2010
  • 연구 목적: 본 연구에서는 자가부식 접착제를 이용한 즉시 상아질 봉쇄 (immediate dentin sealing; IDS)와 지연 상아질 봉쇄 (delayed dentin sealing; DDS)에서 상아질 접착제의 결합강도를 비교하고 즉시 상아질 봉쇄에서 접착제 표면의 오염물을 제거하기 위해 사용되는 air abrasion이 상아질에 대한 미세 인장 결합강도에 어떠한 영향을 주는지에 대해 평가하였다. 연구 재료 및 방법: 1개월 이내에 발거된 사람의 건전한 대구치 30개를 6개의 군으로 분리하였고 상아질 접착제로는 자가부식 접착제 Clearfil SE bond (Kuraray, Okayama, Japan)를 사용하였다. 군분류는 치관부를 삭제하여 상아질을 노출시킨 후 즉시 접착제를 도포하고 복합레진 Filtek Z250 (3M ESPE, St Paul, MN, USA)을 충전한 군을 대조군 (Control), 노출된 상아질에 즉시 상아질 접착제를 도포하고 2주 후 재차 접착제를 도포해 복합레진과 같이 광중합하는 즉시 상아질 봉쇄군 (IDS), 상아질 노출 후 상아질 접착을 즉시 시행하지 않고 2주 후 상아질 접착과 복합레진의 충전을 시행하는 지연 상아질 봉쇄군 (DDS)으로 분류하였다. 그후Control군에 air abrasion을 시행한 군을 C-A, IDS군에 air abrasion을 시행한 군을 IDS-A군, DDS군에 air abrasion을 시행한 군을DDS-A군으로 세분화하였다. Control군과 C-A을 제외한 모든 군은 2주간 Fermit을 이용한 임시수복기간을 두었으며 대조군과 실험군 모두 미세인장 결합강도 실험 전 24시간동안 증류수에 보관 후 미세인장 결합강도를 측정하였다. 측정된 미세인장 결합강도는 one-way ANOVA를 이용하여 비교 분석하였으며 유의차가 있는 경우 Scheffe test를 이용한 사후검증을 시행하였다. 결과: 1. 자가부식 상아질 접착제인 Clearfil SE bond를 치아 삭제 직후 상아질 접착을 시행하고 2주간 임시수복 기간을 거친 후 접착제를 재도포하고 복합레진을 수복한 군과 치아삭제 후 2주간의 임시수복기간을 거친 후 상아질 접착을 시행하고 복합레진을 수복한 군 사이에 상아질-레진 간 미세인장 결합강도는 유의한 차이가 없었다 (P>.05). 2. 자가부식 상아질 접착제인 Clearfil SE bond를 상아질 접착 시행 전 $50{\mu}m$ 크기의 aluminum oxide particle로 air abrasion 처리하는 것은 상아질-레진 간 미세인장 결합강도에 유의한 영향을 주지 않았다 (P>.05).

Effect of dentin pretreatment and curing mode on the microtensile bond strength of self-adhesive resin cements

  • Youm, Seung-Hyun;Jung, Kyoung-Hwa;Son, Sung-Ae;Kwon, Yong-Hoon;Park, Jeong-Kil
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.317-322
    • /
    • 2015
  • PURPOSE. The aim was to evaluate the effect of curing mode and different dentin surface pretreatment on microtensile bond strength (${\mu}TBS$) of self-adhesive resin cements. MATERIALS AND METHODS. Thirty-six extracted human permanent molars were sectioned horizontally exposing flat dentin surface. The teeth were divided into 12 groups (3 teeth/group) according to the dentin surface pretreatment methods (control, 18% EDTA, 10% Polyacrylic acid) and curing mode (self-curing vs. light-curing) of cement. After pretreatment, composite resin blocks were cemented with the following: (a) G-CEM LinkAce; (b) RelyX U200, followed by either self-curing or light-curing. After storage, the teeth were sectioned and ${\mu}TBS$ test was performed using a microtensile testing machine. The data was statistically analyzed using one-way ANOVA, Student T-test and Scheffe's post-hoc test at P<.05 level. RESULTS. For G-CEM LinkAce cement groups, polyacrylic acid pretreatment showed the highest ${\mu}TBS$ in the self-cured group. In the light-cured group, no significant improvements were observed according to the dentin surface pretreatment. There were no significant differences between curing modes. Both dentin surface pretreatment methods helped to increase the ${\mu}TBS$ of RelyX U200 resin cement significantly and degree of pretreatment effect was similar. No significant differences were found regarding curing modes except control groups. In the comparisons of two self-adhesive resin cements, all groups within the same pretreatment and curing mode were significantly different excluding self-cured control groups. CONCLUSION. Selecting RelyX U200 used in this study and application of dentin surface pretreatment with EDTA and polyacrylic acid might be recommended to enhance the bond strength of cement to dentin.

복합레진의 지연충전이 미세인장 결합강도에 미치는 영향 (THE EFFECT OF DELAYED COMPOSITE RESIN FILLING ON MICROTENSILE BOND STRENGTH)

  • 박현식;조영곤;박병철;김종욱;최희영;김종진;진철희;유상훈;기영재
    • Restorative Dentistry and Endodontics
    • /
    • 제29권3호
    • /
    • pp.233-238
    • /
    • 2004
  • The purpose of this study was to evaluate the effect of immediate or delayed composite resin filling on dentinal microtensile bond strength (${\mu}TBS$) after applied the adhesive. The coronal dentin of human third molars was exposed. Single-Bond or One-Step was applied on the dentin surfaces. and composite resin were constructed immediately (group 1) or 5min., 10min., 15min., 20min. and 30min. (groups 2-6) after an adhesive was applied. The specimens were sectioned and made bar-shaped. Each surface area of them was about $1\textrm{mm}^2$. The ${\mu}TBS$ test was performed by EZ test. The results were analysed by One-way ANOVA and Tukey's test at 95% significance level. The results suggested that the ${\mu}TBS$ of Single-Bond to dentin was decreased when the composite resin was constructed 20min. and 30min. after Single-Bond was applied. But the ${\mu}TBS$ of One-Step was not affected by delayed composite resin filling.

All-in-one adhesive의 다층적용이 미세인장결합강도에 미치는 영향 (THE EFFECT OF MULTIPLE APPLICATION ON MICROTENSILE BOND STRENGTH OF ALL-IN-ONE DENTIN ADHESIVE SYSTEMS)

  • 손성애;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제29권5호
    • /
    • pp.423-429
    • /
    • 2004
  • The purpose of this study was to evaluate the effect of multiple application of all-in-one dentin adhesive system on microtensile bond strength using confocal laser scanning microscope and microtensile bond strength test. Flat occlusal dentin surfaces were prepared using low-speed diamond saw. In group I, Scotchbond Multipurpose (SM) was applied by manufacturer's recommendation. In group II, after Adper Prompt L-Pop was applied for 15s and light cured for 10s. the second coat was re-applied and light-cured. In group III, after light-curing the second layer. the third coat was re-applied and light-cured. Specimens bonded with a resin-composite were sectioned into resin-dentin stick for measuring the adhesive layer thickness by confocal laser scanning microscope and evaluating micro-tensile bond strength. The adhesive layers of three-step dentin adhesive system. 3 coats of Adper Prompt L-Pop had significantly thicker than SM. 2 coats of Adper Prompt L-Pop (p < 0.05). However. there was no significant differences in bond strengths between SM and 3 coats of Adper Prompt L-Pop (p > 0.05). And SM. 3 coats of Adper Prompt L-Pop had significantly higher than 2 coats of Adper Prompt L-Pop in bond strengths (p < 0.05).

도말층 존재 유무에 따른 One-step 접착 시스템의 미세인장결합강도 (MICROTENSILE BONDING OF ONE-STEP ADHESIVES TO SHEARED AND NON-SHEARED DENTIN)

  • 송용범;진정희;이세준;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.299-309
    • /
    • 2002
  • The purposes of this study were to evaluate the microtensile bond strength of one-step adhesives accord ing to various dentin surface treatments and to observe the interface between resin(Z-100$^{TM}$) and dentin under SEM. In this study forty-five non-caries extracted human molars and three adhesive systems were used ; AlI-Bond 2(AB), One-Up Bond F(OU), AQ-Bond(AQ). ; In Group 1, 2, 3, AB was used and tooth surfaces were treated by smearing(S), ultrasonic cleansing(US), etching(E) respectively. In Group 4. 5, 6, One-Up Bond F was used and tooth surfaces were also treated as the same way above. In Groups 7, 8, 9, AQ Bond was used and tooth surfaces wet$.$e treated as the same way. Each specimen was prepared for microtensile bond testing, and were stored for 24hrs in 37$^{\circ}C$ distilled water. After that, microtensile bond strength for each specimen was measured. Specimens were fabricated to examine the failure patterns of interface between resin and dentin and observed under the SEM. The results were as follows ; 1. The results(mean$\pm$SD) of microtensile test were group 1, 25.69$\pm$4.31MPa; group 2, 40.93$\pm$10.94MPa; group 3, 47.65$\pm$8.85MPa; group 4, 35.98$\pm$9.14MPa; group 5, 39.66$\pm$8.45MPa; group 6, 43.26$\pm$13.01MPa; group 7, 25.07$\pm$4.2MPa;group 8, 30.4$\pm$4.74MPa;group 9, 33.61$\pm$7.88MPa. 2. One-Up Bond F was showed the highest value of 36.98$\pm$9.14MPa in dentin surface treatment with smearing, and there were significant differences to the other groups (p<0.05). 3. All-Bond 2 was showed the highest value of 40.93$\pm$10.94MPa in dentin surface treatment with ultra-sonic cleansing, but was no significant difference to One-Up Bond F(p>0.05) 4. All-Bond 2 was showed the highest value of 47.65$\pm$8.85MPa in dentin surface treatment with etch ing(10%phosphoric acid), and there were significant differences to the other groups(p<0.05). 5. All-Bond 2 was showed the highest value of 47.65$\pm$8.85MPa in dentin surface treatment according to manufacture's directions. but was no significant difference to One-Up Bond F(p>0.05). 6. AQ Bond was skewed the lowest microtensile bond strength with various dentin surface treatment, and the were significant differences to the other groups(p<0.05).

Microtensile bond strength of resin cement primer containing nanoparticles of silver (NAg) and amorphous calcium phosphate (NACP) to human dentin

  • Arjmand, Nushin;Boruziniat, Alireza;Zakeri, Majid;Mohammadipour, Hamideh Sadat
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.177-183
    • /
    • 2018
  • PURPOSE. The purpose of the current study was to evaluate the effect of incorporating nanoparticles of silver (NAg) and amorphous calcium phosphate (NACP) into a self-etching primer of a resin cement on the microtensile bond strength of dentin, regarding the proven antibacterial feature of NAg and remineralizing effect of NACP. MATERIALS AND METHODS. Flat, mid-coronal dentin from 20 intact extracted human third molars were prepared for cementation using Panavia F2.0 cement. The teeth were randomly divided into the four test groups (n=5) according to the experimental cement primer composition: cement primer without change (control group), primer with 1% (wt) of NACP, primer with 1% (wt) of physical mixture of NACP+Nag, and primer with 1% (wt) of chemical mixture of NACP+Nag. The resin cement was used according to the manufacturer's instructions. After storage in distilled water at $37^{\circ}C$ for 24 h, the bonded samples were sectioned longitudinally to produce $1.0{\times}1.0mm$ beams for micro-tensile bond strength testing in a universal testing machine. Failure modes at the dentin-resin interface were observed using a stereomicroscope. The data were analyzed by one-way ANOVA and Tukey's post-hoc tests and the level of significance was set at 0.05. RESULTS. The lowest mean microtensile bond strength was obtained for the NACP group. Tukey's test showed that the bond strength of the control group was significantly higher than those of the other experimental groups, except for group 4 (chemical mixture of NACP and NAg; P=.67). CONCLUSION. Novel chemical incorporation of NAg-NACP into the self-etching primer of resin cement does not compromise the dentin bond strength.

혼성층의 두께가 three-step과 self-etching 상아질 접착제의 미세인장결합강도에 미치는 효과 (THE EFFECT OF HYBRID LAYER THICKNESS ON MICROTENSILE BOND STRENGTH OF THREE-STEP AND SELF-ETCHING DENTIN ADHESIVE SYSTEMS)

  • 이혜정;박정길;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제28권6호
    • /
    • pp.491-497
    • /
    • 2003
  • The purpose of this study was to evaluate the correlation between hybrid layer thickness and bond strength using confocal laser scanning microscope and microtensile bond strength test of two adhesive systems. The dentin surface of human molars. sectioned to remove the enamel from the occlusal surface. Either Scotchbond Multi-Purpose(3M Dental Product, St. Paul, MN, U.S.A) or Clearfil SE Bond (Kuraray, Osaka, Japan) was bonded to the surface. and covered with resin-composite. The resin-bonded teeth were serially sliced perpendicular to the adhesive interface to measure the hybrid layer thickness by confocal laser scanning microscope. The specimen were trimmed to give a bonded cross-sectional surface area of $1\textrm{mm}^2$, then the micro-tensile bone test was performed at a cross head speed of 1.0 mm/min. All fractured surfaces were also observed by stereomicroscope. There was no significant differences in bond strengths the materials(p>0.05). However. the hybrid layers of three-step dentin adhesive system, SM, had significantly thicker than self-etching adhesive system. CS(p<0.05). Pearson's correlation coefficient showed no correlation between hybrid layer thickness and bond strengths(p>0.05). Bond strengths of dentin adhesive systems were not dependent on the thickness of hybrid layer.