• 제목/요약/키워드: Microfluidic Channel

검색결과 137건 처리시간 0.025초

가변 초점거리 마이크로 유체렌즈 제작 (Fabrication of a Micro fluidic Lens having variable focal length)

  • 이준석;박준근;김규만
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.572-575
    • /
    • 2005
  • A microlens connected to microfluidic channel is fabricated. The microlens is sealed with an elastomeric membrane which deforms by pressure of fluid driven by a syringe pump resulting in the shape change of the microlens. The optical properties of the microlens could be controlled by changing the microlens shape. The microlens system were made of an elastomer, PDMS, using molding from a photoplastic master patterned by UV photolithography. The test results show the optical property of the lens could be made into convex and concave type by applying the fluidic pressure positive and negative.

  • PDF

Neurons-on-a-Chip: In Vitro NeuroTools

  • Hong, Nari;Nam, Yoonkey
    • Molecules and Cells
    • /
    • 제45권2호
    • /
    • pp.76-83
    • /
    • 2022
  • Neurons-on-a-Chip technology has been developed to provide diverse in vitro neuro-tools to study neuritogenesis, synaptogensis, axon guidance, and network dynamics. The two core enabling technologies are soft-lithography and microelectrode array technology. Soft lithography technology made it possible to fabricate microstamps and microfluidic channel devices with a simple replica molding method in a biological laboratory and innovatively reduced the turn-around time from assay design to chip fabrication, facilitating various experimental designs. To control nerve cell behaviors at the single cell level via chemical cues, surface biofunctionalization methods and micropatterning techniques were developed. Microelectrode chip technology, which provides a functional readout by measuring the electrophysiological signals from individual neurons, has become a popular platform to investigate neural information processing in networks. Due to these key advances, it is possible to study the relationship between the network structure and functions, and they have opened a new era of neurobiology and will become standard tools in the near future.

종이기반 미세유체 채널의 설계 및 제작기술 (Design and fabrication of paper microfluidic channel)

  • 이정현;황유선;정효일
    • 감성과학
    • /
    • 제14권4호
    • /
    • pp.525-530
    • /
    • 2011
  • 감성은 외부의 물리/화학적인 자극에 대한 인간 내부의 고차원적인 심리적 체험으로 기쁨, 슬픔, 쾌적, 불쾌 등에 대한 복합적인 감정이라 할 수 있다. 감성연구의 가장 큰 어려움은 측정의 문제이다. 기존 감성측정은 자기보고, 인터뷰, 뇌파 및 자율 신경계 반응, 심장혈관 활동도 등에 국한되어 있다. 최근 나노마이크로 기술의 발달과 함께 미래에는 체액 내 감성 바이오마커를 찾아내고 그것의 유무와 뇌 과학 연구결과와의 상관관계를 규명하고 피 한 방울로 인간의 심리상태를 정확히 파악할 수 있는 초소형 감성진단칩(emotion-on-a-chip)을 개발하게 할 수 있을 것으로 기대된다. 또한 종이를 이용한 종이 미세유체(paper microfluidic) 기술이 발달하고 이를 이용한 질병진단을 할 수 있음이 보고된 바 있다. 종이기반 미세유체채널은 그 제작비용이 저렴하며, 누구나 손쉽게 사용할 수 있어서 미래에 감성진단을 위한 도구로 활용할 수 있다. 본지에서는 아직까지 감성측정분야에 도입되지 않은 종이 미세유체 기술을 소개하고 향후 다양한 감성지표를 측정할 수 있는 아주 간단한 구조의 종이 기반 미세유체 디바이스의 설계 및 제작에 대해 기술한다.

  • PDF

Drop formation of Carbopol dispersions displaying yield stress, shear thinning and elastic properties in a flow-focusing microfluidic channel

  • Hong, Joung-Sook;Cooper-White, Justin
    • Korea-Australia Rheology Journal
    • /
    • 제21권4호
    • /
    • pp.269-280
    • /
    • 2009
  • The drop formation dynamics of a shear thinning, elastic, yield stress ($\tau_o$) fluid (Carbopol 980 (poly(acrylic acid)) dispersions) in silicone oil has been investigated in a flow-focusing microfluidic channel. The rheological character of each solution investigated varied from Netwonian-like through to highly non-Newtonian and was varied by changing the degree of neutralization along the poly (acrylic acid) backbone. We have observed that the drop size of these non-Newtonian fluids (regardless of the degree of neutralisation) showed bimodal behaviour. At first we observed increases in drop size with increasing viscosity ratio (viscosity ratio=viscosity of dispersed phase (DP)/viscosity of continuous phase (CP)) at low flowrates of the continuous phases, and thereafter, decreasing drop sizes as the flow rate of the CP increases past a critical value. Only at the onset of pinching and during the high extensional deformation during pinch-off of a drop are any differences in the non-Newtonian characteristics of these fluids, that is extents of shear thinning, elasticity and yield stress ($\tau_o$), apparent. Changes in these break-off dynamics resulted in the observed differences in the number and size distribution of secondary drops during pinch-off for both fluid classes, Newtonian-like and non-Newtonian fluids. In the case of the Newtonian-like drops, a secondary drop was generated by the onset of necking and breakup at both ends of the filament, akin to end-pinching behavior. This pinch-off behavior was observed to be unaffected by changes in viscosity ratio, over the range explored. Meanwhile, in the case of the non-Newtonian solutions, discrete differences in behaviour were observed, believed to be attributable to each of the non-Newtonian properties of shear thinning, elasticity and yield stress. The presence of a yield stress ($\tau_o$), when coupled with slow flow rates or low viscosities of the CP, reduced the drop size compared to the Newtonian-like Carbopol dispersions of much lower viscosity. The presence of shear thinning resulted in a rapid necking event post onset, a decrease in primary droplet size and, in some cases, an increase in the rate of drop production. The presence of elasticity during the extensional flow imposed by the necking event allowed for the extended maintenance of the filament, as observed previously for dilute solutions of linear polymers during drop break-up.

스마트폰 기반 형광 smartscope의 입자계수 및 회전하는 나선형 채널의 입자정렬 성능 평가 (Evaluation of Particle Counting by Smartphone-based Fluorescence Smartscope and Particle Positioning in Spinning Helical Channel)

  • 박은정;김수빈;조명옥;김경훈;모히우띤;김선욱;이정훈;김중경
    • 한국산업정보학회논문지
    • /
    • 제20권3호
    • /
    • pp.19-28
    • /
    • 2015
  • 스마트폰의 영상정보처리에 기반한 현장 진단기기 개발을 목표로 입자계수용 형광 smartscope와 DC 모터로 제어되는 입자정렬 시스템을 제작하였다. 크기가 작고 저렴한 비용으로 비전문가도 쉽게 다룰 수 있는 smartscope는 LED, 볼렌즈, 형광필터가 설치된 어댑터가 스마트폰 카메라 앞에 장착되어 전용 애플리케이션으로 형광입자와 형광염색된 백혈구를 계수할 수 있었다. 모터는 안드로이드 스마트폰의 블루투스 무선통신 기능을 통해 제어되었다. 나선형 미세유동채널이 축을 중심으로 회전하는 동안 백혈구와 크기가 유사한 입자가 정렬되는 현상을 관찰하였다. 모터로 회전 방향과 속도가 조절되는 입자 정렬 시스템은 많은 시간이 소요되는 수작업을 최소화하고 시료 전처리 과정을 자동화할 수 있으므로, smartscope와 통합될 경우 스마트폰을 이용한 현장진단기기에 활용될 수 있을 것이다.

미세유체소자 내부에서의 Droplet 형성에 대한 Micro-PIV 측정 (Micro-PIV Measurement on the droplet formation in a microfluidic channel)

  • 윤상열;고춘식;김재민;김경천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1534-1539
    • /
    • 2004
  • This experiment has been carried out to measure the process of droplet formation between water phase fluid(PVA 3%) and organic phase fluid(oil) and vector fields measured by a Dynamic Micro-PIV method in the inside of a droplet while generated. Droplet length controlled by changing flow rate conditions in microchannel. Water-in-oil(W/O) droplets successfully generated at a Y junction and cross microchannel. But oil-in-water(O/W) droplets could not be formed at a Y junction microchannel. That is, PVA 3% flow could not be detached from the PDMS surface and ran parallel with oil flow. When PVA 3% flow rate was constant, droplet length and time period decreased as oil flow rate increased, but droplet frequency increased. When PVA 3% and oil flow rate ratio was constant, droplet length and time period decreased as flow rate increased, but droplet frequency increased. All that case, Standard deviation of droplet formation have less than 5% at averaged droplet length and regular-sized droplets were reproducibly formed.

  • PDF

Nanotechnology in Biodevices

  • Choi, Jeong-Woo;Oh, Byung-Keun;Kim, Young-Kee;Min, Jun-Hong
    • Journal of Microbiology and Biotechnology
    • /
    • 제17권1호
    • /
    • pp.5-14
    • /
    • 2007
  • Nanotechnology is the creation and utilization of materials, devices, and systems through the control of matter on the nanometer. The technology has been applied to biodevices such as bioelectronics and biochips to improve their performances. Nanoparticles, such as gold (Au) nanoparticles, are the most widely used of the various other nanotechnologies for manipulation at the nanoscale as well as nanobiosensors. The immobilization of biomolecules is playing an increasingly important role in the development of biodevices with high performance. Nanopatteming technology, which is able to increase the density of chip arrays, offers several advantages, including cost lowering, simultaneous multicomponent detection, and the efficiency increase of biochemical reactions. A microftuidic system incorporated with control of nanoliter of fluids is also one of the main applications of nanotechnologies. This can be widely utilized in the various fields because it can reduce detection time due to tiny amounts of fluids, increase signal-to-noise ratio by nanoparticles in channel, and detect multi-targets simultaneously in one chamber. This article reviews nanotechnologies such as the application of nanoparticles for the detection of biomolecules, the immobilization of biomolecules at nanoscale, nanopatterning technologies, and the microfluidic system for molecular diagnosis.

눈물의 생체 분자 추출을 위한 미세유관이 탑재된 유연한 콘택트 렌즈 (Micro-channel Embedded Soft Contact Lens for Tear Biomolecule Sampling)

  • 김옥철;박형달;송용원;김진석
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권5호
    • /
    • pp.178-185
    • /
    • 2016
  • Tear is a promising biological fluid for non-invasive health monitoring. It has been studied in the past to be a possible candidate for the diagnosis of certain systemic diseases, such as breast cancer, multiple sclerosis, prostate cancer, and diabetes. However, currently existing methods for collecting and extracting tear from the human eye causes inconsistencies in the biomolecule concentrations of the tear sample due to the irritating nature of the process. In response, we designed and fabricated a microfluidic system embedded soft contact-lens for the purpose of tear sampling. The lens was then tested with artificial tear for its tear sampling capability, and found to be able to find concentration equilibrium within 50 minutes. Additionally, simulation was carried out to further optimize the design so that tear sampling rate matched the natural tear turn-over rate of 1 microliter per minute.

공압식 미세밸브를 이용한 다중유체 배열장치 개발 (Development of Multi Sample Array System Based on Pneumatic Valve)

  • 김철민;박서정;김규만
    • 한국정밀공학회지
    • /
    • 제34권1호
    • /
    • pp.59-63
    • /
    • 2017
  • We present a multi-sample array device based on a pneumatic system. Solenoid valves were used to control a micro valve in a pneumatic system. The use of a compressor together with a vacuum pump ensured that one outlet could supply both compression and vacuum pressure. The multi-sample array device was fabricated using conventional photolithography and PDMS casting. The device was composed of a multiplexer, sample array, and rinsing. The multiplexer could control four sample solutions injecting into the sample array chamber. Sample solution not arrayed was removed by DI-water from the rinsing inlet. To prevent trapping of microbubbles in the channel during injection of sample solution into the device, surfactant was added in PDMS solution to serve as a hydrophilic surface treatment. As a result, the device could be used as a sample array for 64 cases, using four samples and three columns of three chambers.

시료주입시 기포발생이 억제된 반응조 형태의 중합효소연쇄반응용 PDMS/유리 바이오칩 (PDMS/Glass Serpentine Microchannel Chip for PCR with Bubble Suppression in Sample Injection)

  • 조철호;조웅;황승용;안유민
    • 대한기계학회논문집A
    • /
    • 제30권10호
    • /
    • pp.1261-1268
    • /
    • 2006
  • This paper reports low-cost microreactor $(10{\mu}{\ell})$ biochip for the DNA PCR (polymerase chain reaction). The microbiochip $(20mm{\times}28mm)$ is a hybrid type which is composed of PDMS (polydimethylsiloxane) layer with serpentine micochannel $(360{\mu}m{\times}100{\mu}m)$ chamber and glass substrate integrated with microheater and thermal microsensor. Undesirable bubble is usually created during sample loading to PMDS-based microchip because of hydrophobic chip surface. Created bubbles interrupt stable biochemical reaction. We designed improved microreactor chamber using microfluidic simulation. The designed reactor has a coner-rounded serpentine channel architecture, which enables stable injection into hydrophobic surface using micropipette only. Reactor temperature needed to PCR reaction is controlled within ${\pm}0.5^{\circ}C$ by PID controller of LabVIEW software. It is experimentally confirmed that SRY gene PCR by the fabricated microreactor chip is performed for less than 54 min.