• Title/Summary/Keyword: Microchannel Flow

Search Result 227, Processing Time 0.03 seconds

Pressure Correction Method and Slip Boundary Conditions for Microflows (미소유동 해석을 위한 압력수정기법 및 미끄럼 경계조건)

  • Choi, Hyung-Il;Maeng, Joo-Sung;Lee, Do-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.430-435
    • /
    • 2001
  • This paper introduces a pressure correction method for microflow computation. Conventional CFD methods with no slip boundary condition fail to predict the rarefaction effect of the wall when simulating gas microflows in the slip-flow regime. Pressure correction method with an appropriate slip boundary condition is an efficient tool in analyzing microscale flows. The present unstructured SIMPLE algorithm adopts both the classical Maxwell boundary condition and Langmuir boundary condition proposed by Myong. The simulation results of microchannel flows show that the proposed method has an effective predictive capability for microscale flows.

  • PDF

Characteristics of Particle Laden Flows in Circular Microchannels (원형 마이크로채널 내의 입자가 부유된 유동의 특성)

  • Kim Y.W.;Jin S.W.;Yoo J.Y.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.85-88
    • /
    • 2005
  • Experimental study has been conducted to evaluate characteristics of particle laden flows at the ratio of channel diameter to particle diameter (B = 14.9, 21.6 and 55). Particle velocities and radial concentrations are obtained using a microscope Nd:YAG laser and cooled CCD camera. Results show that there are relative velocities between the fluid and the particles at B = 14.9. It is also observed that the particles are accumulated at r=$0.5\∼0.82R$, with R being tile tube radius, and particle migration occurs at small Reynolds number, by comparing with the results obtained in macro scale. This gives optimal factors for designing microfluidic channels for cell or Particle separation, particle focusing, and so on.

  • PDF

Dielectric Interaction of Particle in Electrophoresis (전기 영동에서의 입자간의 전기력에 의한 상호 작용)

  • Lee, Ho-Rim;Kang, Kwan-Hyoung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.171-174
    • /
    • 2006
  • When two particles close to each other are in electrophoretic motion, each particle is under the influence of the non-uniform electric field generated by the other particle. Two particles may attract or repel each other due to the dielectric force depending on their positions in the non-uniform electric field. It is shown analytically that two adjusting rigid particles can form an aggregate due to the dielectric interaction. To verify the validity of the theoretical prediction, an experiment is carried out by using a microchannel. In the experiment, AC electric field is used to eliminate cumbersome electroosmotic flow. The experimental result shows that the particles form a chain-like structure, which is typically observed in electro-rheological fluid, due to the dielectric interaction.

  • PDF

Numerical Investigation of the Stability of Flows induced by a Surface Acoustic Wave along a Slab

  • Chu W. Kwang-Hua
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.77-79
    • /
    • 2003
  • The stability of flows induced by a surface acoustic wave (SAW) propagating along the deformable walls in a confined parallel-plane microchannel or slab in the laminar flow regime is investigated. The governing equation which was derived by considering the nonlinear coupling between the deformable or waving interface and viscous fluids is linearized and then the problem is solved by a verified code based on the spectral method together with the associated interface and boundary conditions. The value of the critical Reynolds number was found to be near 1439 which is much smaller than the rigid-wall case: 5772 for conventional pressure-driven flows.

  • PDF

Fabrication of Nickel Nano and Microstructures by Redeposition Phenomena in Ion Etching Process (이온식각공정의 재증착 현상을 이용한 니켈 마이크로 나노 구조물 제작)

  • Jung, Phill-Gu;Hwang, Sung-Jin;Lee, Sang-Min;Ko, Jong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.1 s.256
    • /
    • pp.50-54
    • /
    • 2007
  • Nickel nano and microstructures are fabricated with simple process. The fabrication process consists of nickel deposition, lithography, nickel ion etching and plasma ashing. Well-aligned nickel nanowalls and nickel self-encapsulated microchannels were fabricated. We found that the ion etching condition as a key fabrication process of nickel nanowalls and self-encapsulated microchannels, i.e., 40 sccm Ar flow, 550 W RF power, 15 mTorr working pressure, and $20^{\circ}C$ water cooled platen without using He backside cooling unit and with using it, respectively. We present the experimental results and discuss the formational conditions and the effect of nickel redeposition on the fabrication of nickel nano and microstructures.

Generation of Janus particles smaller than 10-${\mu}$m in diameter (직경 10-${\mu}$m 이하의 야누스 입자 생성)

  • Ahn, Sang-Hoon;Yoo, Jung-Yul
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.679-682
    • /
    • 2008
  • The particle which has two different characteristics on both sides is called Janus particle which is emerging as a key material in microscale transport systems. For example, if one hemisphere has polarity and the other does not, then nonpolar sides would attract each other so that a complex cluster is formed. Thus, this fascinating material can be used as an element of twisting ball panel display, complex micro-scale clusters, drug delivery unit, and active detecting beads. The keywords in developing Janus particle are size and uniformity. Former researches solved uniformity but downsizing still remains a problem. There are three methods to generate small size particles in microchannels: co-flowing, cross-flowing, and elongational flows. In this research, we generate Janus particles smaller than 10-${\mu}$m in diameter using elongational flow in microchannels. And we use UV initiator with Hydrogen UV source to solidify micro size particles. One hemisphere of the particle is coated with rhodamin for visualization.

  • PDF

Fabrication of channel-integrated optoelectrofluidic device using stamp-to-stick bonding and microtransfer methods (Stamp-to-Stick Bonding 및 Microtransfer Molding 방법을 이용한 미세유체 채널이 집적된 광전기유체소자의 제작)

  • Hwang, Hyun-Goo;Lee, Do-Hyun;Park, Je-Kyun
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.154-159
    • /
    • 2009
  • This paper describes two methods - stamp-to-stick bonding and microtransfer molding - to integrate microfluidic channel into an optoelectrofluidic device for in-channel microparticle manipulation. We have demonstrated the optoelectronic microparticle manipulation in the channel-integrated optoelectrofluidic device using a liquid crystal display. As injecting a liquid sample containing $15{\mu}m$-diameter polystyrene particles into the fabricated channel, trapping and transport of individual microparticles have been successfully demonstrated. This channel-integrated optoelectrofluidic device may be useful for several in-channel applications based on the optoelectrofluidics such as optoelectronic flow control, droplet-based protein assay and bead-based immunoassay.

Improvement of Mixing Efficiency of Multilamination Micro Mixer Including Recirculation Zone (재순환 공간 추가에 의한 다적층 마이크로 혼합기의 효율 향상)

  • Lee Jong-Kwang;Kim Yong-Dae;Kwon Se-Jin
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.539-540
    • /
    • 2006
  • It is so difficult to small amounts of two or more fluid species into single in microchannel because flows are usually laminar. In this regard multilamination micro mixer including recirculation zone is presented. Alternating feed micro channels make multilamination and converging-diverging channels form recirculation zone. Multilamination with geometric focusing decreases diffusion path ana recirculation zones make vortex. In this paper flow patterns and mixing properties of multilamination micro mixer including recirculation zone were investigated by Computational Fluid Dynamics (CFD). The CFD results provided qualitative information on mixing.

  • PDF

Fabrication of Microcapsules Encapsulating Fluorescent Nanoparticles and Visualization of Their Inclusion (형광 나노입자를 수용하는 마이크로캡슐의 제작 및 수용 가시화)

  • Kim, Eun-Young;Kim, Hyoung-Hoon;Go, Jeung-Sang
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.2
    • /
    • pp.16-20
    • /
    • 2011
  • This paper presents a fabrication method of microcapsules encapsulating fluorescent nanoparticles sensitive to an organic liquid, which is potentially applicable to the encapsulation of protein, cell and drug. It uses the supra-molecular self-assembly of a block copolymer at the interface of the stable and controllable droplets of water suspended with fluorescent nanoparticles and the polymer solved organic. The size and uniformity of the microcapsules were examined for the various polymer concentrations by using SEM image analysis. The maximum standard deviation of the produced microcapsules of less than 3.5% was obtained from the microcapsules produced from the same conditions. The inclusion of fluorescent nanoparticles was visualized in the fluorescence microscope and by using TEM image. It is shown that this fabrication method can provide the uniform size microcapsules with a higher inclusion.

Evaluation of Electrokinetic Flow Mobility Using Isotacho-Electrophoresis Techniques

  • An, J.H.;Joo, Y.H.;Lee, C.Y.;Lee, Y.J.;Park, C.W.
    • Journal of Magnetics
    • /
    • v.16 no.4
    • /
    • pp.444-448
    • /
    • 2011
  • In the present study, we separated the marker particles from the suspending particle mixture solution using isotacho-electrophoresis technique, a novel quantitative ionic particle separation method, in the microchannel. A multiple stacking zone of the suspending particle was visualized with variations in electric field strength, pH value and concentration of the ionic solution. In particular, the electrophoretic mobility of ionic particle (fluorescein) was estimated based on the electrophoretic velocity value measured by the particle image velocimetry. As a result, isotacho-electrophoresis zones were clearly visualized as going downstream in the electric field. The particle migration velocity increased proportional to the applied voltage increase; it was also affected by the pH value variations in the ionic solution.