• Title/Summary/Keyword: Micro-defect

Search Result 220, Processing Time 0.02 seconds

Dentinal defects induced by 6 different endodontic files when used for oval root canals: an in vitro comparative study

  • Pawar, Ajinkya M;Thakur, Bhagyashree;Kfir, Anda;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.31.1-31.9
    • /
    • 2019
  • Objectives: To compare the formation of dentinal defects using stainless-steel hand K-files (HFs), rotary files, reciprocating files, and Self-Adjusting File (SAF), when used for oval root canals. Materials and Methods: One hundred and forty extracted human mandibular premolar with single root and oval canal were selected for this study. Oval canals were confirmed by exposing to mesio-distal and bucco-lingual radiographs. Teeth with open apices or anatomic irregularities were excluded. All selected teeth were de-coronated perpendicular to the long axis of the tooth, leaving roots segments approximately of 16 mm in length. Twenty teeth were left unprepared (control), and the remaining 120 teeth were divided into 6 groups (n = 20) and instrumented using HF (size 40/0.02), Revo-S (RS; size 40/0.06), ProTaper NEXT (PTN; size 40/0.06), WaveOne (WO; size 40/0.09), RECIPROC (RC; size 40/0.06), and the SAF (2 mm). Roots were then sectioned 3, 6, and 9 mm from the apex, and observed under stereomicroscope, for presence of dentinal defects. "No defect" was defined as root dentin that presented with no visible microcracks or fractures. "Defect" was defined by microcracks or fractures in the root dentin. Results: The control, HF, and SAF did not exhibit any dentinal defects. In roots instrumented by RS, PTN, WO, and RC files exhibited microcracks (incomplete or complete) in 40%, 30%, 55%, and 50%, respectively. Conclusions: The motor-driven root canal instrumentation with rotary and reciprocating files may create microcracks in radicular dentine, whereas the stainless-steel hand file instrumentation, and the SAF produce minimal or less cracks.

Photo-crosslinked gelatin methacryloyl hydrogel strengthened with calcium phosphate-based nanoparticles for early healing of rabbit calvarial defects

  • Da-Na Lee;Jin-Young Park;Young-Wook Seo;Xiang Jin;Jongmin Hong;Amitava Bhattacharyya;Insup Noh;Seong-Ho Choi
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.321-335
    • /
    • 2023
  • Purpose: The aim of this study was to investigate the efficacy of photo-crosslinked gelatin methacryloyl (GelMa) hydrogel containing calcium phosphate nanoparticles (CNp) when applying different fabrication methods for bone regeneration. Methods: Four circular defects were created in the calvaria of 10 rabbits. Each defect was randomly allocated to the following study groups: 1) the sham control group, 2) the GelMa group (defect filled with crosslinked GelMa hydrogel), 3) the CNp-GelMa group (GelMa hydrogel crosslinked with nanoparticles), and 4) the CNp+GelMa group (crosslinked GelMa loaded with nanoparticles). At 2, 4, and 8 weeks, samples were harvested, and histological and micro-computed tomography analyses were performed. Results: Histomorphometric analysis showed that the CNp-GelMa and CNp+GelMa groups at 2 weeks had significantly greater total augmented areas than the control group (P<0.05). The greatest new bone area was observed in the CNp-GelMa group, but without statistical significance (P>0.05). Crosslinked GelMa hydrogel with nanoparticles exhibited good biocompatibility with a minimal inflammatory reaction. Conclusions: There was no difference in the efficacy of bone regeneration according to the synthesized method of photo-crosslinked GelMa hydrogel with nanoparticles. However, these materials could remain within a bone defect up to 2 weeks and showed good biocompatibility with little inflammatory response. Further improvement in mechanical properties and resistance to enzymatic degradation would be needed for the clinical application.

A Study on the Micro-defects Characteristics and Latch-up Immune Structure by RTA in 1MeV P Ion Implantation (1MeV 인 이온 주입시 RTA에 의한 미세결함 특성과 latch-up 면역에 관한 구조 연구)

  • Roh, Byeong-Gyu;Yoon, Seok-Beom
    • Journal of IKEEE
    • /
    • v.2 no.1 s.2
    • /
    • pp.101-107
    • /
    • 1998
  • This paper is studied micro-defect characteristics by phosphorus 1MeV ion implantation and Rs, SRP, SIMS, XTEM for the RTA process was measured and simulated. As the dose is higher, the Rs is lower. When the dose are $1{\times}10^{13}/cm^2,\;5{\times}10^{13}/cm^2,\;1{\times}10^{14}/cm^2$, the Rp are $1.15{\mu}m,\;1.15{\mu},\;1.10{\mu}m$ respectively. As the RTA time is longer, the maximum concentration position is deeper from the surface and the concentration is lower. Before the RTA was done, we didn't observe any defect. But after the RTA process was done, we could observe the RTA process changed the micro-defects into the secondary defects. The simulation using the buried layer and connecting layer structure was performed. As results, the connecting layer had more effect than the buried layer to latch-up immune. Trigger current was more $0.6mA/{\mu}m$ and trigger voltage was 6V at dose $1{\times}10^{14}/cm^2$ and the energy 500KeV of connecting layer Lower connecting layer dose, latch-up immune characteristics was better.

  • PDF

Thermal Compression of Copper-to-Copper Direct Bonding by Copper films Electrodeposited at Low Temperature and High Current Density (저온 및 고전류밀도 조건에서 전기도금된 구리 박막 간의 열-압착 직접 접합)

  • Lee, Chae-Rin;Lee, Jin-Hyeon;Park, Gi-Mun;Yu, Bong-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.102-102
    • /
    • 2018
  • Electronic industry had required the finer size and the higher performance of the device. Therefore, 3-D die stacking technology such as TSV (through silicon via) and micro-bump had been used. Moreover, by the development of the 3-D die stacking technology, 3-D structure such as chip to chip (c2c) and chip to wafer (c2w) had become practicable. These technologies led to the appearance of HBM (high bandwidth memory). HBM was type of the memory, which is composed of several stacked layers of the memory chips. Each memory chips were connected by TSV and micro-bump. Thus, HBM had lower RC delay and higher performance of data processing than the conventional memory. Moreover, due to the development of the IT industry such as, AI (artificial intelligence), IOT (internet of things), and VR (virtual reality), the lower pitch size and the higher density were required to micro-electronics. Particularly, to obtain the fine pitch, some of the method such as copper pillar, nickel diffusion barrier, and tin-silver or tin-silver-copper based bump had been utillized. TCB (thermal compression bonding) and reflow process (thermal aging) were conventional method to bond between tin-silver or tin-silver-copper caps in the temperature range of 200 to 300 degrees. However, because of tin overflow which caused by higher operating temperature than melting point of Tin ($232^{\circ}C$), there would be the danger of bump bridge failure in fine-pitch bonding. Furthermore, regulating the phase of IMC (intermetallic compound) which was located between nickel diffusion barrier and bump, had a lot of problems. For example, an excess of kirkendall void which provides site of brittle fracture occurs at IMC layer after reflow process. The essential solution to reduce the difficulty of bump bonding process is copper to copper direct bonding below $300^{\circ}C$. In this study, in order to improve the problem of bump bonding process, copper to copper direct bonding was performed below $300^{\circ}C$. The driving force of bonding was the self-annealing properties of electrodeposited Cu with high defect density. The self-annealing property originated in high defect density and non-equilibrium grain boundaries at the triple junction. The electrodeposited Cu at high current density and low bath temperature was fabricated by electroplating on copper deposited silicon wafer. The copper-copper bonding experiments was conducted using thermal pressing machine. The condition of investigation such as thermal parameter and pressure parameter were varied to acquire proper bonded specimens. The bonded interface was characterized by SEM (scanning electron microscope) and OM (optical microscope). The density of grain boundary and defects were examined by TEM (transmission electron microscopy).

  • PDF

A Study of Thermal and Chemical Quenching of Premixed Flame by Flame-Surface Interaction (화염-표면 상호작용에 의한 예혼합 화염의 열소염 및 화학소염에 관한 연구)

  • Kim, Kyu-Tae;Lee, Dae-Hoon;Kwon, Se-Jin
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.2
    • /
    • pp.1-8
    • /
    • 2005
  • Incomplete combustion due to quenching in a narrow confinement has been a major problem for realization of a reliable micro combustion device. In most micro combustors, effects of flows are absent in the quenching because the flow is laminar and no severe stretch is present. In such circumstance, quenching is caused either by heat loss or by removal of active radicals to the wall surface of the confinement. An experimental investigation was carried out to investigate the relative significance of these two causes of quenching of a premixed flame. A premixed jet burner with a rectangular cross section at the exit was built. At the burner exit, the flame stands between two walls with adjustable distance. The gap between the two walls at which quenching occurs was measured at different wall surface conditions. The results were analyzed to estimate the relative significance of heat loss to the wall and the removal of radicals at the surface. The measurements indicated that the quenching distance was independent of the wall surface characteristics such as oxygen vacancy, grain boundary, or impurities at low temperature. At high temperature, however, the surface characteristics strongly affect the quenching distance, implying that radical removal at the wall plays a significant role in the quenching process.

  • PDF

Development of intelligent agent system for automated ship CAE modelling by non-deterministic optimized methods (비 결정론적 최적화 기법을 이용한 선박의 CAE 모델링 자동화를 위한 지능형 에이전트 시스템의 개발)

  • Bae, Dong-Myung;Kim, Hag-Soo;Shin, Chang-Hyuk;Wang, Qing
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.44 no.1
    • /
    • pp.57-67
    • /
    • 2008
  • Recently, Korean shipbuilding industry is keeping up the position of world wide No. 1 in world shipbuilding market share. It is caused by endless efforts to develope new technologies and methods and fast development of IT technologies in Korea, to raise up its productivities and efficiency in shipbuilding industry with many kinds of optimizing methods including genetic algorithm or artificial life algorithm... etc. In this paper, we have suggested the artificial life algorithm with relay search micro genetic algorithm. and we have improved a defect of simple genetic algorithm for its slow convergence speed and added a variety of solution candidates with applying relay search simple genetic algorithm. Finally, we have developed intelligent agent system for ship CAE modeling. We have tried to offer some conveniences a ship engineer for repeated ship CAE modeling by changing ship design repeatedly and to increase its accuracy of a ship model with it.

Defect Inspection of Phase Shift Photo-Mask with Digital Hologram Microscope (디지털 홀로그램 현미경을 이용한 위상차 포토마스크 결함 측정)

  • Cho, Hyung-Jun;Lim, Jin-Woong;Kim, Doo-Cheol;Yu, Young-Hun;Shin, Sang-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.303-308
    • /
    • 2007
  • We report here on the application of a digital holographic microscope as a metrology tool for the inspection and the micro-topography reconstruction of different micro-structures of phase shift photo-mask (PSM). The lithography by phase shift photo-mask uses the interference and the pattern of the PSM is not imaged by general optical microscope. The technique allows us to obtain digitally a high-fidelity surface topography description of the phase shift photo-mask with only one hologram image acquisition, allowing us to have relatively simple and compact set-ups able to give quantitative information of PSM.

Comparative study of new bone formation capability of zirconia bone graft material in rabbit calvarial

  • Kim, Ik-Jung;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.167-176
    • /
    • 2018
  • PURPOSE. The purpose of this study was to compare the new bone formation capability of zirconia with those of other synthetic bone grafts. MATERIALS AND METHODS. Twelve rabbits were used and four 6-mm diameter transcortical defects were formed on each calvaria. Each defect was filled with Osteon II (Os), Tigran PTG (Ti), and zirconia (Zi) bone grafts. For the control group, the defects were left unfilled. The rabbits were sacrificed at 2, 4, and 8 weeks. Specimens were analyzed through micro computed tomography (CT) and histomorphometric analysis. RESULTS. The Ti and Zi groups showed significant differences in the amount of newly formed bone between 2 and 4 weeks and between 2 and 8 weeks (P<.05). The measurements of total bone using micro CT showed significant differences between the Os and Ti groups and between the Os and Zi groups at 2 and 8 weeks (P<.05). Comparing by week in each group, the Ti group showed a significant difference between 4 and 8 weeks. Histomorphometric analysis also showed significant differences in new bone formation between the control group and the experimental groups at 2, 4, and 8 weeks (P<.05). In the comparison of newly formed bone, significant differences were observed between 2 and 4 weeks and between 2 and 8 weeks (P<.05) in all groups. CONCLUSION. Zirconia bone graft material showed satisfactory results in new bone formation and zirconia could be used as a new synthetic bone graft material.

Effects of poly (ethylene glycol-propylene glycol) copolymer on hemostasis and osteogenesis in a rat calvarial defect model

  • Kim, Ha-Eun;Yoon, Hun-Young;Kim, Eun-Jin;Kim, Sun-Jong
    • Korean Journal of Veterinary Research
    • /
    • v.60 no.3
    • /
    • pp.145-153
    • /
    • 2020
  • This study aimed to evaluate the effects of a bioabsorbable bone hemostatic agent comprising poly (ethylene glycol-propylene glycol) copolymers (PEG-PPG) on hemostasis and osteogenesis. Bilateral 3 mm diameter calvarial defects were created in 99 male Sprague-Dawley rats. The defects were filled with PEG-PPG or bone wax. The defects of control group were left unfilled. Virtual autopsy was performed to evaluate bioabsorption. The calvaria were subjected to x-ray microtomography (microCT) and histological examination. Bone volume fraction (BV/TV) and bone mineral density (BMD) were measured using microCT; furthermore, white blood cell count and histological examination were performed. After application of PEG-PPG and bone wax, immediate hemostasis was achieved. Autopsy revealed that PEG-PPG disappeared within 48 h at the application site; in contrast, bone wax remained until 12 weeks. The PEG-PPG and control groups showed significantly more osteogenesis than the bone wax group with respect to BV/TV and BMD at 3, 6, and 12 weeks (p < 0.05). Histology revealed that the bone wax group exhibited little bone formation with inflammation. In contrast, PEG-PPG and control groups showed significantly more qualitative osteogenesis than the bone wax group (p < 0.01). In conclusion, PEG-PPG showed immediate hemostasis and was absorbed to allow progressive osteogenesis.

Micro-Chemical Structure of Polyaniline Synthesized by Self-Stabilized Dispersion Polymerization

  • NamGoong, Hyun;Woo, Dong-Jin;Lee, Suck-Hyun
    • Macromolecular Research
    • /
    • v.15 no.7
    • /
    • pp.633-639
    • /
    • 2007
  • A variety of NMR techniques were applied to the micro-chemical structural characterization of polyanilines prepared via an efficient synthetic method in a self-stabilized dispersion medium in which the polymerization was conducted in a heterogeneous organic/aqueous biphasic system without any stabilizers. Here, the monomer and growing polymer chain were shown to function simultaneously as a stabilizer, imparting compatibility for the dispersion of the organic phase, and as a form of flexible template in an aqueous reaction medium. Polymerizations predicated on this concept generated polyanilines with a low defect content: solution state $^{13}C-NMR$ and solid $^{13}CDD/CP/MAS$ spectroscopy indicated that the synthesized HCPANi and its soluble derivative, HCPANi-t-BOC, evidenced distinctly different NMR spectra with fewer side peaks, as compared to conventionally prepared PANis, and the complete structural assignments of the observed NMR peaks could be determined via the combination of both 1D and 2D techniques. Ortho-linked defects in HCPANi were estimated to be as low as 7%, as shown by a comparison of the integration of the carbonyl carbon resonance peaks.