• 제목/요약/키워드: Micro element

검색결과 819건 처리시간 0.028초

다결정 SiC 마이크로 공진기의 제작과 그 특성 (Fabrication and characteristics of polycrystalline SiC micro resonators)

  • 정귀상;이태원
    • 센서학회지
    • /
    • 제17권6호
    • /
    • pp.425-428
    • /
    • 2008
  • This paper describes the resonant characteristics of polycrystalline SiC micro resonators. The $1{\mu}m$ thick polycrystalline 3C-SiC cantilevers with different lengths were fabricated using a surface micromachining technique. Polycrystalline 3C-SiC micro resonators were actuated by piezoelectric element and their fundamental resonance was measured by a laser vibrometer in vacuum at room temperature. For the $100{\sim}40{\mu}m$ long cantilevers, the fundamental frequency appeared at $147.2kHz{\sim}856.3kHz$. The $100{\mu}m$ and $80{\mu}m$ long cantilevers have second mode resonant frequency at 857.5.kHz and 1.14.MHz, respectively. Therefore, polycrystalline 3C-SiC resonators are suitable for RF MEMS devices and bio/chemical sensor applications.

새로운 구조를 갖는 마이크로 PM형 스테핑 모터 개발 (Development of the Micro PM type Stepping Motor with Newly Structure)

  • 류세현;권병일;정인성;성하경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1261-1263
    • /
    • 2005
  • The micro permanent magnet(PM) type stewing motor preferred solution for many small electronics position determination devices since it is small in size. Thus, there are growing demands for PM type stepping motor that greater mechanical output, smaller size. But, the design of the it, having high performance and small size is very difficult because of its complex mechanical structure. This paper deals with a development of the newly structured micro PM type stepping motor with claw-poles. We introduced the small-sized PM type stepping motor that has new structure and analyzed the magnetic characteristic of it versus general type model using 3-D finite element analysis(FEA).

  • PDF

Design of Polycrystalline 3C-SiC Micro Beam Resonators with Corrugation

  • Chung, Gwiy-Sang;Nhan, Nguyen Duong The;Thach, Phan Duy
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권5호
    • /
    • pp.193-197
    • /
    • 2008
  • On the purpose of increasing resonant frequency without sacrificing quality factor as well as much decreasing dimensions, corrugated micro beam resonator based on polycrystalline 3C-SiC films is the applicable solution. In this work, appropriate corrugated structure is suggested to increase resonant frequency of resonators. Micro beam resonators based on 3C-SiC films which have a two-side corrugation along the length of beams were simulated by finite element method and compared to a same-size flat rectangular. With the dimension of 36x12x0.5 ${\mu}m^{3}$, the flat cantilever has resonant frequency of 746 kHz. Meanwhile, with this size but corrugation width of 6 ${\mu}m$ and depth of 0.4 ${\mu}m$, the corrugated cantilever reaches the resonant frequency at 1.252 MHz.

유한요소법을 이용한 레이저 미세 패터닝 공정 해석 (Simulation of Laser Micro Patterning Process Using FEM)

  • 이진호;김병희;이종길
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 금형가공,미세가공,플라스틱가공 공동 심포지엄
    • /
    • pp.54-58
    • /
    • 2005
  • Femtosecond laser is the latest generation pulsed laser delivering shortest pulses. Any solid materials can be machined by it. Femtosecond laser micromachining allows highest precision and minimal heat influence within the workpiece. But due to the complex physical phenomena between the laser beam and the workpiece materials, it is very difficult to determine the optimal process conditions in the femtosecond laser micromachining. In this study, a method to simulate the femtosecond laser micromachining process was proposed. And femtosecond laser micro patterning processes of chromium thin film are simulated by the proposed method using a commercial FE code, LS-Dyna. Simulation results were compared with those of experiments.

  • PDF

지향성 보청기 성능 검사 장치 개발 (Development of Directional Digital Hearing Aid Performance Testing System)

  • 장순석;권유정;이제형
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.469-474
    • /
    • 2005
  • The most recent trend on digital hearing aid is to increase the ratio of signal to noise by directivity or to develop noise reduction algorithm inside DSP IC chip. This paper designed, fabricated and tested a digital hearing aid directivity testing device in which a micro-mouse-1ike the stepping motor with a speaker rotates around an examinant. Both ears of the examinant were fixed with ITE hearing aids in order to response to receiving sound. The experimental results were compared with a boundary element method program for verification. The diameter of the directivity testing device was 2 [m] and the micro-mouse was precisely controlled by PICBASIC micro processor.

  • PDF

탄성 몰드 변형을 이용한 은 이온 잉크의 원-스텝 나노스케일 패터닝 (One-Step Nanoscale Patterning of Silver Ionic Ink via Elastic Mold Deformation)

  • 오용석
    • 센서학회지
    • /
    • 제32권4호
    • /
    • pp.252-256
    • /
    • 2023
  • A one-step method for nanoscale patterning of silver ionic ink on a substrate is developed using a microscale, elastic mold deformation. This method yields unique micro/nanoscale metallic structures that differ from those produced using the original molds. The linewidth of these metallic structures is significantly reduced (approximately 10 times) through the sidewall deformation of the original mold cavity on a thin liquid film, as verified by finite element analysis. The process facilitates the fabrication of various, isolated and complex micro/nanoscale metallic structures with negligible residual layers at low cost and high throughput. These structures can be utilized for various applications, including optoelectronics, wearable sensors, and metaverse-related devices. Our approach offers a promising tool for manipulation and fabrication of micro/nanoscale structures of various functional materials.

교합하중에 의한 치경부 응력분포의 3차원 유한요소해석 (Stress Distribution of Occlusal Loading Applied on Cervical Region Using 3D Finite Element Analysis)

  • 우성관;김광훈;손권;박정길
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.521-522
    • /
    • 2006
  • Occlusal loading is considered as the main factor of noncarious cervical lesions. The goal of this study is to identify stress distribution using three dimensional finite element analysis, when occlusal loading is applied on the cervical lesion of human tooth. A finite element model was constructed from micro-CT image and three kinds of static force(500 N) were assumed. In all cases stress concentrates on the same area in the cement-enamel junction. This finding is consistent with published experimental results.

  • PDF

열간압연시 미세조직 예측을 위한 유한요소 모델 (A Finite Element Model for Predicting the Microstructural Evolution in Hot Rolling)

  • 조현중;김낙수
    • 한국정밀공학회지
    • /
    • 제14권9호
    • /
    • pp.90-100
    • /
    • 1997
  • A full three-dimensional thermo-coupled rigid-viscoplastic finite element method and the currently developed microstructural evolution system which includes semi-empirical equations suggested by different research groups were used together to form an integrated system of process and micro- structure simulation of hot rolling. The distribution and time histroy of the momechanical variables such as temperature, strain, strain rate, and time during pass and between passes were obtained from the finite element analysis of multipass hot rolling processes. The distribution of metallurgical variables were calculated on the basis of instantaneous thermomechanical data. For the verification of this method the evolution of microstructure in plate rolling and shape rolling was simulated and their results were compared with the data available in the literature. Consequently, this approach makes it possible to describe the realistic evolution of microstructure by avoiding the use of erroneous average value and can be used in CAE of multipass hot rolling.

  • PDF

Multiscale analysis using a coupled discrete/finite element model

  • Rojek, Jerzy;Onate, Eugenio
    • Interaction and multiscale mechanics
    • /
    • 제1권1호
    • /
    • pp.1-31
    • /
    • 2008
  • The present paper presents multiscale modelling via coupling of the discrete and finite element methods. Theoretical formulation of the discrete element method using spherical or cylindrical particles has been briefly reviewed. Basic equations of the finite element method using the explicit time integration have been given. The micr-macro transition for the discrete element method has been discussed. Theoretical formulations for macroscopic stress and strain tensors have been given. Determination of macroscopic constitutive properties using dimensionless micro-macro relationships has been proposed. The formulation of the multiscale DEM/FEM model employing the DEM and FEM in different subdomains of the same body has been presented. The coupling allows the use of partially overlapping DEM and FEM subdomains. The overlap zone in the two coupling algorithms is introduced in order to provide a smooth transition from one discretization method to the other. Coupling between the DEM and FEM subdomains is provided by additional kinematic constraints imposed by means of either the Lagrange multipliers or penalty function method. The coupled DEM/FEM formulation has been implemented in the authors' own numerical program. Good performance of the numerical algorithms has been demonstrated in a number of examples.

지도학습 기반 분할기법을 이용한 단층 촬영된 단방향 복합재료의 유한요소모델 생성 및 검증 (Generation and Validation of Finite Element Models of Computed Tomography for Unidirectional Composites Using Supervised Learning-based Segmentation Techniques)

  • 김대의;진성원;김영배;임재혁;김윤호
    • Composites Research
    • /
    • 제36권6호
    • /
    • pp.395-401
    • /
    • 2023
  • 본 연구에서는 지도학습 기반 분할기법을 이용하여 단층 촬영된 단방향 복합재료의 유한요소모델링을 실시하였다. 우선, 단방향 복합재료의 형상 정보를 얻기 위해 Micro-CT 스캔을 수행하여 단방향 복합재료의 순수 체적(raw volume)을 획득하였고 여기에 몇 개의 단면을 선택하여 재료의 마이크로 구조인 섬유의 형상을 라벨링하였다. 이후 재료의 단면 이미지와 라벨링한 이미지를 각각 입출력으로 U-net 모델을 훈련시켰다. 이를 사용하여 선택되지 않은 단층촬영 이미지를 섬유형상을 구분하는 분할을 수행하였고 이렇게 생성된 3차원 정보를 이용해서 유한요소모델을 생성하였다. 최종적으로 단방향 복합재료 시편과 유한요소모델의 섬유체적비를 비교하여 제안된 방법의 적절성을 확인하였다.