• 제목/요약/키워드: Micro cooling

검색결과 289건 처리시간 0.036초

마이크로다공성 발열체 표면에서의 액체분무 냉각성능 특성 (Characteristics on Spray Cooling Performance on the Micro-Porous Coated Surfaces)

  • 김윤호;최치환;이규정
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.304-311
    • /
    • 2006
  • Experiments on evaporative spray cooling on the square plate heaters with plain or micro-porous coated surfaces were performed in this study. Micro-porous coated surfaces were made by using DOM [Diamond particle, Omegabond 101, Methyl-Ethyl-Keton] method. In case of purely air-jet cooling, the micro-porous coating doesn't affect the cooling capacity. In spray cooling three different flow patterns (complete wetting, evaporative wetting, dryout) are observed on both plain and micro-porous coated surfaces. The effects of various operating conditions, such as water flow rate, particle size, and coating thickness were investigated on the micro-porous coated surfaces. It is found that the level of surface wetting is an important factor to determine the performance of spray cooling. It depends on the balance between absorbed liquid amount by capillary force over porosity and the evaporative amount. The micro-porous coated surface has largest cooling capacity, especially in the evaporative wetting zone. It is found that the effects of liquid flow rate and coating thickness are significant in evaporative wetting zone, but are not in complete wetting and dryout zones.

A Review on Cooling Technologies for Micro and Miniature Devices and Systems

  • Yoon, Jae-Sung;Choi, Jong-Won;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권2호
    • /
    • pp.70-77
    • /
    • 2007
  • As electric and mechanical devices have been miniaturized and highly integrated, heat generation per unit volume has been greatly increased. Therefore, effective cooling methods for micro and miniature systems have emerged as critical issues nowadays and a lot of studies have been carried out to find an optimum cooling strategy. This paper reviews recent researches on the cooling technologies which are mainly based on micro-fabrication processes. Design, development, experiments and numerical analysis of various cooling devices are discussed and their characteristics, problems and advantages are compared.

초음파진동을 이용한 미세분무냉각 열전달에 관한 실험적 연구 (The Experimental Study on Mist Cooling Heat Transfer)

  • 김영찬
    • 한국분무공학회지
    • /
    • 제15권4호
    • /
    • pp.202-207
    • /
    • 2010
  • Mist cooling is widely employed as a cooling technique of high temperature surfaces, and it has heat transfer characteristics similar to boiling heat transfer which has the convection, nucleate and film boiling regions. In the present study, mist cooling heat transfer was experimentally investigated for the mist flow impacting on the heated surfaces of mico-fins. The mist flow was generated by supersonic vibration. Experiments were conducted under the test conditions of droplet flow rate, $Q=6.02{\times}10^{-9}{\sim}3.47{\times}10^{-8}\;m^3/s$ and liquid temperature, $T_f=30{\sim}35^{\circ}C$. From the experimental results, it is found that an increase in the droplet flow rate improves mist cooling heat transfer in the both case of smooth surface and surfaces of micro-fins. Micro-fins surfaces enhance the mist cooling heat transfer. Besides, the experimental results show that an increase in the droplet flow rate decrease the heat transfer efficiency of mist cooling.

Temperature analysis of extra vessel electromagnetic pump cooling for a Micro nuclear reactor with an electric power of 20 MW

  • Tae Uk Kang;Hee Reyoung Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.275-282
    • /
    • 2024
  • Lead bismuth eutectic (LBE) is used as coolant for MicroURANUS, a small marine nuclear power plant, and this coolant is transported in the plant by an electromagnetic pump. Given the considerable heat generated by the electromagnetic pump, the cooling of the pump is essential. This study compared air cooling and water-cooling methods and found that the maximum temperatures during air and water cooling were 640 K and 372 K, respectively. These findings were utilized to design an electromagnetic pump with water-cooling. The maximum temperature of the pump was lower than the boiling point of water; thus, the pump did not require a separate pressurization. Consequently, the resistance problem of the coil and the deformation problem of the material caused by generated heat can be solved through water-cooling.

CPU 냉각용 저소음 Micro-Cooling Fan 의 개발 (Development of Micro-Cooling Fans for Cooling of CPU)

  • 김기황;박용민;김진화;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.961-966
    • /
    • 2001
  • Micro fans of randomly swept-blades were designed to provide C.P.U. in a personal computer with effective cooling in a very quiet mode. The proto--type axial micro-fans machined by a laser sintering machine were tested against manufactured products by comparing the performance and overall sound pressure level with spectral measurements in an environment suggested by ASHRAE and ANSI standards. The predicted OSPLs and directivity patterns of fans by iDesignFan software were in good agreements with measured data. The newly introduced fans of randomly swept-blades were proved to provide a very promising mode of low noise at small loading conditions.

  • PDF

Comparison of Unconfined and Confined Micro-scale Impinging Jets

  • Choo, Kyo-Sung;Youn, Young-Jik;Kim, Sung-Jin
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2210-2213
    • /
    • 2008
  • In the present study, effects of degree of confinement on heat transfer characteristics of a micro-scale slot jet impinging on a heated flat plate are experimentally investigated. The effects of Reynolds numbers (Re = $1000{\sim}5000$), lateral distances (x/B = $1{\sim}10$), nozzle-to-plate spacings (Z/B = $1{\sim}20$), and degree of confinement ($B_c$/B = 3, 48) on the Nusselt number are considered. The results show that the effects of the degree of confinement on the cooling performance of the micro-scale impinging slot jet are significant at lower nozzle-to-plate spacings and higher Reynolds numbers. In addition, it is shown that the cooling performance of the micro-scale unconfined slot impinging jet is 200% higher than that of the micro-scale confined slot impinging jet.

  • PDF

모바일 전자장비 냉각용 Micro-CPL내 형상크기변화에 따른 열성능 해석 (Effect of Groove and Channel Size on the Thermal Transport Capacity of Micro-Capillary Pumped Loop for Mobile Electronic Device Cooling System)

  • 김병기;서정세;황건;문석환;배찬효
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.329-334
    • /
    • 2005
  • As more high power wide band gap devices are being utilized. the thermal management issues associated with these devices need to be resolved. High power small devices dissipate excessive heat that must be cooled, but traditional cooling methods are insufficient to provide such a cooling means. This paper will evaluate a micro-capillary pumped loop thermal management system that is incorporated into the shim of the device, taking advantage of phase-change to increase the thermal conductivity of the system. The results of the modeling of the thermal management system will be discussed.

  • PDF

전자제어 장치를 이용한 용광로 냉각관 누수 지동 감지장치 개발에 관한 연구 (A Study on Automatic Sensing Device for Water Leakage of Cooling Pipe at Blast Furnace by Use The Electronic System)

  • 강창수;강기성
    • 전자공학회논문지 IE
    • /
    • 제46권4호
    • /
    • pp.25-30
    • /
    • 2009
  • 용광로는 외피 부분에 내부 내화물의 온도를 낮추기 위하여 냉각수를 공급하는 냉각판 또는 스테이브를 사용하고 있다. 주변 조업 조건의 열악으로 냉각수를 공급하는 배관의 부식으로 냉각수가 내화물에 침투하여 내화물의 수명을 떨어뜨리고, 노황을 악화시키는 원인이 되고 있다. 이에 본 연구는 용광로 냉각설비장치에 이상 현상이 발생하였을 때 위치를 정확히 확인함에 따라 신속하게 누수된 부위를 파악하여 대처할 수 있는 기능을 갖춘 냉각관 누수 자동감지장치를 개발하였다. 주된 연구는 전자제어 장치인 마이크로프로세서를 응용한 전자변 제어장치를 이용하여 냉각설비의 파손으로 발생되는 누수현상으로 인한 고열과 분진 일산화탄소 등의 산출로 작업환경의 재해를 자동방지 하고자 하였으며, 작업환경이 친환경적이며 작업의 가치를 재창출할 수 있는 방법들이 연구되고 있다. 용광로 분위기의 일산화탄소 자동 감지장치와 그에 따른 출력신호를 자동 전송하는 무선중계기 장치를 개발함으로 용광로 냉각설비 장치의 분위기 작업환경을 수동방식에서 무인자동화방식으로 개선하였다.

Fe 오염에 따른 Si내의 deep level거동에 관한 연구 (The Study of Deep Level Behaviors in Si Contaminated by Iron)

  • 문영희;김종오
    • 한국재료학회지
    • /
    • 제9권1호
    • /
    • pp.104-107
    • /
    • 1999
  • Fe 강제오염된 p-Si에서 여러 가지 quenching 조건에 기인한 에너지 준위들을 deep level transient spectroscopy(DLTS)를 이용하여 측정하였으며, 또한 선택 에칭방법/Optical microscope을 이용한 BMD(bulk micro-defeat)측정을 통하여 Fe 침전물 형서에, Fe 확산을 위한 어닐링 후 Cooling 조건이 미치는 영향을 분석하였다. Cooling 조건들이 여러 종류의 hole trap과 bulk micro-defeat(BMD)형성에 영햐을 주는 것으로 나타났으며, normal cooling의 경우 $\textrm{Fe}_{i}$, 또는 Fe-O complex 와 관계있는 $\textrm{T}_{1},\;\textrm{T}_{2},\;\textrm{T}_{3},\;\textrm{T}_{4}$ trap이 나타났으며, Slow Cooling 의 영향으로 인하여 활성화 에너지가 0.4eV에 해당하는 trap들이 관찰되었다. 또한 $\textrm{Fe}^{+}\textrm{}^{-}$ pair(H4: 0.56eV)는 $\textrm{LN}_{2}$ quenching한 경우에서만 나타났다.

  • PDF

강제대류 및 핵비등영역에 있어서 마이크로 휜 형상이 분무냉각 열전달에 미치는 영향 (Effects of Micro-fin Structure on Spray Cooling Heat Transfer in Forced Convection and Nucleate Boiling Region)

  • 김영찬
    • 대한기계학회논문집B
    • /
    • 제34권11호
    • /
    • pp.983-990
    • /
    • 2010
  • 본 연구에서는 냉각면의 표면온도가 비교적 낮은 강제대류 및 핵비등영역에서 다양한 종류의 마이크로 휜이 가공된 냉각면의 분무냉각 열전달에 대해 실험적으로 연구하였다. 실험결과로부터 냉각면 표면에 가공된 마이크로 휜은 분무냉각 열전달을 촉진시키며, 냉각휜의 크기와 종류에 상관없이 분무유량이 증가할수록 분무냉각 열전달도 큰 폭으로 증가하고 있음을 알 수 있었다. 또한 희박한 분무영역에서는 냉각면에 가공된 휜의 크기와 형상이 분무냉각 열전달에 큰 영향을 미치고 있으나, 분무유량이 증가할수록 이러한 경향은 점차 약해져 본 실험에서 가장 높은 분무유량조건에서는 편평한 냉각면을 제외한 모든 냉각면의 열유속이 거의 동일하게 나타나고 있음을 알 수 있었다.