• Title/Summary/Keyword: Metal-Ion

Search Result 2,181, Processing Time 0.03 seconds

Adsorption and Separation of U (VI), Co (II), and Dy (III) Metal Ions on Crown Synthetic Resin

  • Kim, Joon-Tae
    • Journal of Integrative Natural Science
    • /
    • v.10 no.1
    • /
    • pp.43-50
    • /
    • 2017
  • Synthetic resins were combined 1-aza-12-crown-4 macrocyclic ligand with styrene divinylbenzene copolymer having 1%, 2%, 8%, and 16% crosslink by a substitution reaction. These synthetic resins were confirmed by chlorine content, elementary analysis, SEM, surface area, and IR-spectrum. As the results of the effects of pH, crosslink of synthetic resin, and dielectric constant of a solvent on metal ion adsorption for resin adsorbent, the metal ions showed high adsorption at pH 3 or over. Adsorption selectivity for the resin in ethanol solvent was the order of uranium ($UO_2{^{2+}}$) > cobalt ($Co^{2+}$) > dysprosium ($Dy^{3+}$) ion, adsorbability of the metal ion was the crosslink in order of 1%, 2%, 8%, and 16% and it was increased with the lower dielectric constant. In addition, theses metal ions could be separated in the column with 1% crosslink resin by using nitric acid (pH 2.0) as an eluent.

Study of the Influence of Heavy Metal Ions(Cu, Cr, Pb, Zn) on Biochemical Oxygen Demand (BOD 測定에 影響을 미치는 重金屬이온에 關한 연구)

  • Choi, Taek-Pyul;Yun, O-Sub
    • Journal of Environmental Health Sciences
    • /
    • v.9 no.2
    • /
    • pp.75-81
    • /
    • 1983
  • The Biochemical Oxygen Demand(BOD) indicates that microbes are proliferating or that oxygen is being spent by breathing action when examining water under the same aerobic condition. In this research of the mesurement of BOD are the poisonous elements of heavy metal ions such as Cu-ion, Cr-ion, Pb-ion and Zn-ion. They exert an unfavorable influence in the analysis of BOD and research was performed to provide certain data of minimum negative influence by the poisonous matters. The results of the research confirm that heavy metal ion(Cu, Cr, Pb, Zn) do direct an influence upon the normal growth of aerobic microbes in actual tests of chemical analysis of portable water or sewage. The most critical concentration for a negative effect on lowering oxygen quantity and disturbing the aerobic mocrobes normal growth was found to be 0.01 mg/l. Therefore, test results are not valid if the heavy metal concentration is to or greater than 0.0mg/l, To improve comprehension through out the research the author uses the following abbreviations: 1. The Cu-ion is to be excluded before experimental analysis if it is over 0.01mg/l inorder to obtain a real value for the BOD. 2. The Cr-ion is to be excluded before experimental analysis if it is over 0.01mg/l in order to obtain a real value for the BOD. 3. The Pb-ion is to be excluded before experimental analysis if it is over 0.01mg/l in order to obtain a real value for the BOD. 4. The Zn-ion is to be excluded before experimental analysis if it is over 0.01mg/l in order to obtain a real value for the BOD.

  • PDF

Metal Ion Catalysis in Nucleophilic Substitution Reaction of 4-Nitrophenyl Picolinate with Alkali Metal Ethoxides in Anhydrous Ethanol

  • Hong, Yeon-Ju;Kim, Song-I;Um, Ik-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.9
    • /
    • pp.2483-2487
    • /
    • 2010
  • Pseudo-first-order rate constants ($k_{obsd}$) were measured spectrophotometrically for nucleophilic substitution reactions of 4-nitrophenyl picolinate (6) with alkali metal ethoxides (EtOM, $M^+\;=\;K^+$, $Na^+$ and $Li^+$) in anhydrous ethanol at $25.0{\pm}0.1^{\circ}C$. The plot of $k_{obsd}$ vs. [EtOM] exhibits upward curvature regardless of the nature of $M^+$ ions. However, the plot for the reaction of 6 with EtOK is linear with significantly decreased $k_{obsd}$ values when 18-crown-6-ether (18C6, a complexing agent for $K^+$ ion) is added in the reaction medium. Dissection of $k_{obsd}$ into $k_{EtO^-}$ and $k_{EtOM}$ (i.e., the second-order rate constant for the reaction with dissociated $EtO^-$ and ion-paired EtOM, respectively) has revealed that ion-paired EtOM is 3~17 times more reactive than dissociated $EtO^-$. The reaction has been proposed to proceed through a 5-membered cyclic transition state, in which $M^+$ ion increases the electrophilicity of the reaction site. Interestingly, $Na^+$ ion exhibits the largest catalytic effect. The presence of a nitrogen atom in the pyridine moiety of 6 has been suggested to be responsible for the high $Na^+$ ion selectivity.

Abatement of Metal Ion Contents from Cotton Linter for the Manufacture of Regenerated Cellulose (방직용 재생섬유 제조를 위한 면 린터의 금속이온 함량 저감에 관한 연구)

  • Park, Hee Jeong;Son, Ha Neul;Choi, Jin Sung;Seo, Yung Bum
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.45 no.6
    • /
    • pp.17-23
    • /
    • 2013
  • The reduction of metal ion from the cotton linter for the preparation of NMMO (N-methylmorpholine N-oxide)-based dissolving pulp was investigated. The NMMO-based dissolving pulp was usually used for the manufacture of high quality fabrics, and need to have high alpha cellulose content and high brightness. NMMO, which is environmentally friendly, and reusable after recovering process, is very sensitive to the metal ions such as Cu, Fe, Mg, and Cr. Electron beam, sulfuric acid, acetic acid, and ozone treatment before bleaching were used and the concentration changes of the metal ions were compared to that of EDTA, a chelating agent. It was found that both acid treatments (sulfuric and acetic acid) were very effective and comparable to EDTA treatment at the same dosage in metal ion reduction, but electron beam and ozone treatment were not. The sulfuric acid treatment turned out to be effective in metal ion reduction, and most inexpensive.

Photoluminescent Graphene Oxide Microarray for Multiplex Heavy Metal Ion Analysis

  • Liu, Fei;Ha, Hyun Dong;Han, Dong Ju;Park, Min Su;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.281.2-281.2
    • /
    • 2013
  • Since heavy metal ions included in water or food resources have critical effects on human health, highly sensitive, rapid and selective analysis for heavy metal detection has been extensively explored by means of electrochemical, optical and colorimetric methods. For example, quantum dots (QDs), such as semiconductor QDs, have received enormous attention due to extraordinary optical properties including high fluorescence intensity and its narrow emission peaks, and have been utilized for heavy metal ion detection. However, the semiconductor QDs have a drawback of serious toxicity derived from cadmium, lead and other lethal elements, thereby limiting its application in the environmental screening system. On the other hand, Graphene oxide (GO) has proven its superlative properties of biocompatibility, unique photoluminescence (PL), good quenching efficiency and facile surface modification. Recently, the size of GO was controlled to a few nanometers, enhancing its optical properties to be applied for biological or chemical sensors. Interestingly, the presence of various oxygenous functional groups of GO contributes to opening the band gap of graphene, resulting in a unique PL emission pattern, and the control of the sp2 domain in the sp3 matrix of GO can tune the PL intensity as well as the PL emission wavelength. Herein, we reported a photoluminescent GO array on which heavy metal ion-specific DNA aptamers were immobilized, and sensitive and multiplex heavy metal ion detection was performed utilizing fluorescence resonance energy transfer (FRET) between the photoluminescent monolayered GO and the captured metal ion.

  • PDF

Technologies for Next-Generation Metal-Ion Batteries Based on Aqueous Electrolytes (수계전해질기반 차세대 금속이온전지 기술)

  • D.O. Shin;J. Choi;S.H. Kang;Y.S. Park;Y.-G. Lee
    • Electronics and Telecommunications Trends
    • /
    • v.39 no.1
    • /
    • pp.83-94
    • /
    • 2024
  • There have been continuous requirements for developing more reliable energy storage systems that could address unsolved problems in conventional lithium-ion batteries (LIBs) and thus be a proper option for large-scale applications like energy storage system (ESS). As a promising solution, aqueous metal-ion batteries (AMIBs) where water is used as a primary electrolyte solvent, have been emerging owing to excellent safety, cost-effectiveness, and eco-friendly feature. Particularly, AMIBs adopting mutivalence metal ions (Ca2+, Mg2+, Zn2+, and Al3+) as mobile charge carriers has been paid much attention because of their abundance on globe and high volumetric capacity. In this research trend review, one of the most popular AMIBs, zinc-ion batteries (ZIBs), will be discussed. Since it is well-known that ZIBs suffer from various (electro) chemical/physical side reactions, we introduce the challenges and recent advances in the study of ZIBs mainly focusing on widening the electrochemical window of aqueous electrolytes as well as improving electrochemical properties of cathode, and anode materials.

Nucleation, Growth and Properties of $sp^3$ Carbon Films Prepared by Direct $C^-$ Ion Beam Deposition

  • Kim, Seong I.
    • The Korean Journal of Ceramics
    • /
    • v.3 no.3
    • /
    • pp.173-176
    • /
    • 1997
  • Direct metal ion beam deposition is considered to be a whole new thin film deposition technique. Unlike other conventional thin film deposition processes, the individual deposition particles carry its own ion beam energies which are directly coupled for the formation of this films. Due to the nature of ion beams, the energies can be controlled precisely and eventually can be tuned for optimizing the process. SKION's negative C- ion beam source is used to investigate the initial nucleation mechanism and growth. Strong C- ion beam energy dependence has been observed. Complete phase control of sp3 and sp3, control of the C/SiC/Si interface layer, control of crystalline and amorphous mode growth, and optimization of the physical properties for corresponding applications can be achieved.

  • PDF

Development of Inductively Coupled Plasma Gas Ion Source for Focused Ion Beam (유도결합형 플라즈마 소스를 이용한 집속 이온빔용 가스 이온원 개발)

  • Lee, Seung-Hun;Kim, Do-Geun;Kang, Jae-Wook;Kim, Tae-Gon;Min, Byung-Kwon;Kim, Jong-Kuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.1
    • /
    • pp.19-23
    • /
    • 2011
  • Recently, focused ion beam (FIB) applications have been investigated for the modification of VLSI circuit, the MEMS processing, and the localized ion doping, A multi aperture FIB system has been introduced as the demands of FIB applications for high speed and large area processing increase. A liquid metal ion source has problems, a large angular divergence and a metal contamination into a substrate. In this study, a gas ion source was introduced to replace a liquid metal ion source. The gas ion source generated inductively coupled plasma (ICP) in a quartz tube (diameter: 45 mm). Ar gas fed into the quartz was ionized by a 2 turned radio frequency antenna. The Ar ions were extracted by 2 extraction grids. The maximum extraction voltage was 10 kV. A numerical simulation was used to optimize the design of extraction grids and to predict an ion trajectory. As a result, the maximum ion current density was 38 $mA/cm^2$ and the spread of ion energy was 1.6 % for the extraction voltage.

Removal of Alkali Metal Ion and Chlorine Ion Using the Ion Exchange Resin (이온교환수지를 이용한 알칼리 금속 이온 및 염소 이온의 제거)

  • Lee, Kyung-Han;Kil, Bo-Min;Ryu, Cheol-Hwi;Hwang, Gab-Jin
    • Membrane Journal
    • /
    • v.30 no.4
    • /
    • pp.276-281
    • /
    • 2020
  • A research was conducted on the removal of ion from the solution involving the alkali metal ion and chlorine ion using ion exchange resin. The cation exchange resin and anion exchange resin was used for the remove of metal ion (Na+ and K+) and chlorine ion (Cl-), respectively. In the case of solution A (involving 36,633 ppm of Na+ and 57,921 ppm of Cl-), the Na+ ion and Cl- ion were removed over 99% within 20 min. In the case of solution B (involving 1,638 ppm of K+), the K+ ion was removed over 99% within 3 min.

Capacity of Oil Cake Ion Exchanger (깻묵 이온교환체의 이온교환능)

  • Dong Won Kim;Hae Young Song;Hwang, Myeong Cheon;Hae Il Ryu
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.300-305
    • /
    • 1981
  • The soy bean oil cakes and perillar oil cakes are phosphorylated and sulfonated to be used as ion exchangers. There 40-60mesh cations exchanges have bean tested on the capacity of ion exchange, the adsorption and distribution coefficients of several metal ions in various concentrations of binary solution mixture, hydrochloric acid and alcohol. From there experiments, the following results are concluded. The ion exchange capacity of ion exchangers are higher than 4 meq/g. The adsorption of metal ions on ion exchangers are increased generally as pH is increased, especially Co(II) on sulfonated soy bean oil cake. The distribution coefficients of various metal ions are decreased as the number of branches of carbon and hydroxyl groups are increased. There show that the stereo-isomerism of alkyl group or attraction of ligand have influenced upon various metal ions. Consequently it is deduced that there ion exchanges from soy bean oil cake and perillar oil cake resemble in properties to current ion exchangers.

  • PDF