• Title/Summary/Keyword: Membrane Stress

Search Result 692, Processing Time 0.028 seconds

Development of Measurement Equipment of Membrane Stress Using White Noise Sound Wave (화이트 노이즈 음파를 이용한 막구조물의 장력 측정장치 개발)

  • Jin, Sang-Wook;Ohmori, Hiroshi;Kim, Jae-Yeol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.2
    • /
    • pp.63-72
    • /
    • 2008
  • One of the most important matters in keeping membrane structures in healthy condition is to maintain the proper tension distribution over the membrane. However, it is not easy to know the real stress level in the membrane quantitatively after completion of the structures. Authors suggested measurement method that can measure membrane stress using sound wave, and have been holding experimental tests of membrane stress measurement that used the sound external excitation with sine wave and white noise. The concept of the method is the fact that measurement of resonance frequency by vibrating membrane having rectangular boundary by audible frequency can measure membrane stress indirectly. In this paper, through the experimental tests it is proved that the equipment can be used for not only the membrane material of type A but also for types B and C. In addition, it is proved that the developed measurement equipment is available to stably measure the membrane stress which exists in the membrane material of the actual membrane structures.

  • PDF

Study on Stress Transition Mechanism and Uniaxial Tensile Characteristics by Tensile Fractured Test of Clamping Part of Membrane Structures (막구조 정착부의 인장파단시험을 통한 신장특성 및 응력전달체계에 관한 연구)

  • Kim, Hee-Kyun;Jeon, Sang-Hyeon;Ha, Chang-Woo;Kim, Jae-Yeol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.20 no.3
    • /
    • pp.91-98
    • /
    • 2020
  • For form stability of membrane structures, membrane material is required to be in tension. Therefore, in planning and maintenance management, the engineer should consider enough about introduction of stress during construction and re-introduction of stress after completion. Clamping part is an important portion with the function for introducing tension into membrane materials, and the function to transmit stress to boundary structures, such as steel frames. Then, the purpose of this research is to clarify stress condition and stress transfer mechanism including clamping part of membrane structures, and to grasp the changing tendency of membrane structures with the passage of time. In this research, following previous one, we perform well-balanced evaluation by conducting tensile fractured tests of clamping part's specimens, and by measuring individually the amount of displacement of not only overall specimen's length but membrane material and clamping part. Thereby, we consider the influence the difference in the hardness of edge rope and the difference in the direction of thread affect modification and fracture load.

Study on stress transition mechanism by tensile and fracture characteristics of membrane material at bolting part in clamping part of membrane Structures (막구조 정착부의 볼트접합부 막재료의 신장 및 파단상태를 통한 응력전달체계에 관한 연구)

  • Kim, Hee-Kyun;Shim, Chun-Bo;Kim, Jae-Yeol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.23 no.4
    • /
    • pp.97-105
    • /
    • 2023
  • The membrane structure should maintain the membrane materials in tension for structural stability guaranty. The anchoring part in the membrane structure is an important part. It has the function to introduce tension into membrane materials and function to transmit stress which membrane materials receives to boundary structure such as steel frames. In this paper, it grasps anchoring system of the anchoring part in the membrane structure concerning the fracturing characteristic condition of membrane structure, and the influence which is caused to yield it designates the stress state when breaking the membrane structure which includes the anchoring part and that stress transition mechanism is elucidated as purpose. This paper follows to previous paper, does 1 axial tensile test concerning the bolting part specimen, grasp of fracturing progress of the bolting part and the edge rope and hardness of the rubber, does the appraisal in addition with the difference of bolt tightening torque. As a result, the influence which the bolt anchoring exerts on the fracturing characteristics of the membrane material in the membrane structure anchoring part is examined.

Effect of compressible membrane's nonlinear stress-strain behavior on spiral case structure

  • Zhang, Qi-Ling;Wu, He-Gao
    • Structural Engineering and Mechanics
    • /
    • v.42 no.1
    • /
    • pp.73-93
    • /
    • 2012
  • With an active structural involvement in spiral case structure (SCS) that is always the design and research focus of hydroelectric power plant (HPP), the compressible membrane sandwiched between steel spiral case and surrounding reinforced concrete was often assumed to be linear elastic material in conventional design analysis of SCS. Unfortunately considerable previous studies have proved that the foam material serving as membrane exhibits essentially nonlinear mechanical behavior. In order to clarify the effect of membrane (foam) material's nonlinear stress-strain behavior on SCS, this work performed a case study on SCS with a compressible membrane using the ABAQUS code after a sound calibration of the employed constitutive model describing foam material. In view of the successful capture of fitted stress-strain curve of test by the FEM program, we recommend an application and dissemination of the simulation technique employed in this work for membrane material description to structural designers of SCS. Even more important, the case study argues that taking into account the nonlinear stress-strain response of membrane material in loading process is definitely essential. However, we hold it unnecessary to consider the membrane material's hysteresis and additionally, employment of nonlinear elastic model for membrane material description is adequate to the structural design of SCS. Understanding and accepting these concepts will help to analyze and predict the structural performance of SCS more accurately in design effort.

A Study on the Stress Concentration at Crack of Membrane Structures (막구조물의 파손단면에서의 응력집중 현상에 관한 연구)

  • Jeon, Jin-Hyung;Jeong, Eul-Seok;Kim, Seung-Deog
    • Proceeding of KASS Symposium
    • /
    • 2005.05a
    • /
    • pp.89-98
    • /
    • 2005
  • Membrane structures, a kind of lightweight soft structural system, are used for spatial structures. The material property of the membrane has strong axial stiffness, but little bending stiffness. Therefore membrane structures arc unstable structures initially. These soft structures need to be introduced initial stresses first because of its initial unstable state, and it happens large deformation phenomenon. To find the structural shape after large deformation caused by initial stiffness introduced, we need the shape analysis considering geometric nonlinearity in structural design procedure. In this study, we investigate into the stress concentration at crack of membrane structures. Therefore, using the nonlinear analysis program that NASS (Nonlinear Analysis for Spatial Structures) perform nonlinear analysis, and stress distribution for creak length investigate for using linear elastic fracture mechanics.

  • PDF

Finite Element Analysis of Membrane for LNG Storage Tank (액화천연가스 저장탱크용 멤브레인의 유한요소해석)

  • 김영규;윤인수;홍성호;전인기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2797-2804
    • /
    • 1994
  • This paper analyzes the behaviors of corrugated membrane under the cryogenic liquid pressure and thermal loading using the FEM analysis program MARC. The FEM calculations were carried out on the basis of measured data of Technigaz membrane. It is very important to know the concentration levels and distributions of stress in the corrugated membrane. A quarter of the membrane sheet in place of the whole membrane was simulated because of its geometric symmetricity. The calculated results of the concentrated stress showed that the maximum stress occurs at the knot parts and at the root corner radius of the corrugations. The FEM calculated results indicated that the ring knot membrane which was developed in this study showed uniformly distributed stress and the lowest stress levels in the cross knot area in comparison with other two membranes. These results are very important to optimize the shape and improve the safety of membrane structure.

Verification for Reduction of Membrane Stress Measurement Equipment Size Using White Noise Sound Wave (화이트노이즈를 이용한 막장력 측정장치의 소형·경량화 검증)

  • Jin, Sang-Wook
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.3
    • /
    • pp.67-74
    • /
    • 2014
  • The author has proposed and verified the accuracy through experiments on a method of measurement through the use of sound waves that not only can quantitatively measure each of the dual directions of the fiber axis with high accuracy of membrane tension created on the surface of the membrane structure, but also can be easily operated in the field of construction. This paper reports the solution for problems of variables caused in the process of downsizing of the measurement equipment in order for practical use, and verifies the correspondence possibility of various stress ratios.

A Study on Uniaxial Tensile Stress of Tensioned Membrane (인장막구조물의 단축인장응력에 관한 연구)

  • Kang, Joo-Won;Kim, Jae-Yeol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.3
    • /
    • pp.85-93
    • /
    • 2011
  • Membrane materials are very flexible, thus wrinkling, uniaxial state, can be occurred. The wrinkling are due to lots of various factors as eccentric force, construction errors, and fabrication errors. These wrinkled membrane elements are in status of uniaxial stress. In the paper, a method which be able to check the wrinkling is proposed. The stress-deformation analysis of membrane structures for given external load will be carried out, and here the membrane elements are regarded as wrinkled state if the principal stress 2 is smaller than 0. With proposed method, two existed construction examples, Suwon auditorium and Okinawa 75 Expo, are analyzed.

The Influences of Residual Stress on the Frequency of Ultrasonic Transducers with Composite Membrane Structure

  • Lee Seungmock;Kim Jong-Min;Shin Young-Eui
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.76-84
    • /
    • 2006
  • Arrayed ultrasonic sensors based on the piezoelectric thin film (lead-zirconate-titanate: Pb($Zr_{0.52}Ti_{0.48})O_{3}$) having composite membrane structure are fabricated. Different thermal and elastic characteristics of each layer generate the residual stress during the high temperature deposition processes, accomplished diaphragm is consequently bowing. We present the membrane deflection effects originated from the residual stress on the resonant frequencies of the sensor chips. The resonant frequencies ($f_r$) measured of each sensor structures are located in the range of $87.6{\sim}111\;kHz$, these are larger $30{\sim}40\;kHz$ than the resultant frequencies of FEM. The primary factors of $f_r$ deviations from the ideal FEM results are the membrane deflections, and the influence of stiffness variations are not so large on that. Membrane deflections have the effect of total thickness increase which sensitively change the $f_r$ to the positive direction. Stress generations of the membrane are also numerically predicted for considering the effect of stiffness variations on the $f_r$.

DEVEOPMENT OF MEASURING SYSTEM OF MEMBRANE STRESS FOR MEMBRANE STRUCTURE (막구조물의 막장력 측정장치 개발에 관한 연구)

  • Jung, Hwan-Mok;Woo, Jae-Won;Cho, Byung-Wook;Lee, Seong-Yeun
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.171-178
    • /
    • 2008
  • This paper is concerned with the development of a measurement system using field measuring device which will give the membrane stress of the membrane structures. Up to this point, several techniques on measurement of membrane stresses has been proposed and some have been used in the fields, but accuracy of the measured stresses to be far from reliable one. Such situation has not been changed until recent days, we do not have the measurement device on which we can depend. On top of that, due to the different properties in cross directions for material of the membrane, the stress in the warp direction is different from that in the fill one. A new method is proposed to measured membrane stresses in two different direction separately, where instead of membrane stresses directly, an external force perpendicular to the membrane to be applied. A portable device can measure the applied force and the displacement. A special testing bed to be fabricated to accommodate $50cm{\times}50$ manbrane specimen which can apply 5 ton load in two orthogonal direction. A special device using push-pull gage was developed. To measure the membrane stresses in warp and fill direction separately, a different length of the tips are used. The measuring device which can called tension meter, can be calibrated on the testing bed, and optimized the length and shape of tip.

  • PDF