투시 검사 시 장비에 따른 환자와 시술자의 입사표면선량 연구 (Fluoroscopic the equipment study in accordance with the entrance surface dose study of patients and practitioners)

  • 양해두;홍선숙;성민숙;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제15권2호
    • /
    • pp.13-18
    • /
    • 2013
  • Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom ($25cm{\times}25cm$) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.

  • PDF

결합 의료기기 관리제도의 규제관련 법률에 관한 연구 (A Study on Regulatory Law for Management System of Combined Medical Device)

  • 최용전;최미림;이정찬;정용규
    • 서비스연구
    • /
    • 제4권2호
    • /
    • pp.1-10
    • /
    • 2014
  • 최근 우리나라 기술발전과 글로벌화 경향에 맞추어, 의료기기산업도 국제적인 의료기기관리제도에 적합하도록 체질을 개선해 가고 있으며, 국제적인 규제수준에 도달할 수 있도록 완화의 가닥을 잡고 있다. 또한 최근의 입법 경향을 보면 의료기기 산업의 각종 규제는 최소한의 범위에 머물고 새로운 기술의 결합 내지 융합에 개방적인 자세를 취하고 있다. 결합 의료기기에 활용된 의료기술은 대부분이 인체나 환경에 위해성이 없는 의료기술일 가능성이 크므로, 이렇게 위해성이 제로에 가까운 의료기기를 1등급으로 분류하여 위해성이 거의 없는 의료기기와 같이 취급함으로써 발생하는 불필요한 행정력과 시간의 낭비를 최소화할 수 있다. 이를 통하여 의료기기 취급자 특히 판매업자에 포함되는 사업자의 영역이 넓혀지므로, 사업자들의 사업의지를 고양할 수 있으며, 국민의 의료기기에 대한 선택권과 접근권이 제고될 수 있다. 본 논문에서는 결합 의료기기의 중고 수리 및 유통질서를 확립하고 공정한 거래를 촉진하기 위한 제반의 법률을 조사하고 규제를 개선하는 방향을 제시한다.

  • PDF

이차자료원을 활용한 의원 의료서비스 수입 및 비용 산출 (The Income and Cost Estimate for the Medical Clinic Services Based on Available Secondary Data)

  • 김선제;임민경
    • 한국병원경영학회지
    • /
    • 제26권1호
    • /
    • pp.71-82
    • /
    • 2021
  • Purpose: The purpose of this study is to estimate incomes and costs of the medical clinics by using secondary data. Methodology: The medical incomes and costs were estimated from 405 clinics operated by sole practitioner providing out-patient services among all clinics subject to the Medical Cost Survey on National Health Insurance Patients in 2017, excluding dental clinics and oriental medical clinics. The incomes and costs of the medical clinics were reflected with incomes and costs of health insurance benefits and were calculated by types of medical services (i.e., basic care, surgery, general treatment, functional test, specimen test and imaging test). The costs were classified as follows: labor costs, equipment costs, material costs and overhead costs. Secondary data was used to estimate the incomes and costs of the medical clinics. For allocation bases for costs for each type of the medical service, the ratio of revenue from health insurance benefits by types of medical services was applied. However, labor costs were calculated with the activity ratio by types of medical services and occupations, using clinical expert panel data. Finding: The percentage of health insurance income for all medical income was 73.1%. The health insurance cost per clinic was 401,864 thousand won. Labor cost accounted for the largest portion of the health insurance income was 191,229 thousand won (47.6%), followed by management cost was 170,018 thousand won (42.3%), materials cost was 35,434 thousand won (8.8%), and equipment costs was 5,183 thousand won (1.3%). Practical Implications: This study suggests a method of estimating incomes and costs of medical clinic services by using secondary data. It could efficiently provide incomes and costs to assess an appropriate level of the health insurance fee to the clinics.

의학용 초음파검사기에 의한 MoSi2의 미소결함 탐상 (A Study on Detection of Small Defects for MoSi2 by Medical Ultrasonic Testing)

  • 남궁재관;김유철
    • 한국안전학회지
    • /
    • 제10권4호
    • /
    • pp.9-12
    • /
    • 1995
  • Detection of small defects by medical ultrasonic testing when the thermal sprayed coating by $MoSi_2$ on the metal is done. The defects may occur at the bonded surface. So, the detecting method of the defects by non-destructive in spection is desired. Here, in order to examine the possibility of the detection of the small defects by the ultrasonic. The electronic scanning ultrasonic equipment using an array probe developed as the medical ultrasonic diagnostic equipment is applied for the detection of the metal material defects. It's validity is investigated.

  • PDF

유한요소법을 이용한 와전류 영향 전달함수의 계산 (Calculation of the Eddy Current Effect Transfer Function Using the Finite Element Method)

  • 이수열;강현수;이정한;문치웅;이강석;조민형
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.92-93
    • /
    • 1998
  • In this study, we have established the technique to estimate the gradient waveforms distorted by the eddy current in MRI. After obtaining the eddy current effect transfer function using the finite element method, we have used the transfer function to estimate the output gradient waveforms at any points inside the imaging region. We also present experimental results to be compared with estimated ones.

  • PDF

사이클로트론 구성부품별 고장통계분석 (Analysis on Failure Statistics of Cyclotron Component)

  • 조준호;정재은;정홍문;원도연
    • 대한디지털의료영상학회논문지
    • /
    • 제16권1호
    • /
    • pp.61-67
    • /
    • 2014
  • The demand of cyclotron for PET (positron emission tomography) has rapidly grown as the more use of PET or PET-CT equipment requires the increased amount of radioactive isotopes for clinical positron emission. While research on failure statistics of medical equipment used in medical centers has continued to be done, the analysis and study on failure statistics of cyclotron have rarely been conducted. However, the growing demand shows the urgency of systematical management guideline and countermeasures for device failure to minimize any supply delay of radiopharmaceuticals occurred by such failure and complains from waiting patients for PET-CT diagnosis. Therefore, this study aims to analyze the failure report from Minitrace equipped in cyclotron which is owned by the department of nuclear medicine at Yeungnam University Medical Center and draws on the data to build effective management system for cyclotron.

  • PDF

개방형 자기공명영상시스템을 위한 평면형 경사자계코일 (Planar Gradient Coils for an Open MRI System)

  • 이수열;박부식;이정한;이완
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.165-168
    • /
    • 1996
  • Though the planar gradient coils, designed by the magnetic energy minimization procedure, have smaller inductance than conventional gradient coils, the planar gradient oils often suffer from their poor magnetic field linearity. Scaling the spatial frequencies of the current density function designed by the magnetic energy minimization procedure, magnetic field linearity of the planar gradient coils can be featly improved with small sacrifice of gradient coil inductance.

  • PDF

치과의료기관 의료장비 표면 및 치과위생사 손의 Staphylococcus epidermidis 오염도 조사 (Survey of Staphylococcus epidermidis Contamination on the Hands of Dental Hygienists and Equipment Surface of Dental Clinics)

  • 김설희
    • 치위생과학회지
    • /
    • 제17권6호
    • /
    • pp.472-480
    • /
    • 2017
  • 치과의료기관 의료장비 표면 및 치과위생사 손의 S. epidermidis 오염도 조사를 위해 2017년 7월부터 8월까지 일부지역 20개 치과의원에서 치과위생사 20인의 손 오염, 치과별 7부위 표면 140부위의 S. epidermidis 오염도를 조사하였다. S. epidermidis 오염도는 핸드플레이트와 로닥플레이트를 사용하였으며, $35^{\circ}C$ 24시간 배양하였다. 손 오염도는 핸드플레이트 기준에 근거하여 저, 중, 고 그룹으로 분류한 후 그룹별 손 부위별 오염도를 ANOVA 분석하였다. 의료장비 표면 오염수준은 집락을 계수하여 기술통계 하였다. 치과위생사 55%는 중등도 이상의 손 오염이 있었고, 부위별로는 손바닥이 29.45 CFU로 가장 높게 나타났으며, 그 다음으로는 중지 7.8 CFU, 약지 6.4 CFU, 엄지 6 CFU 순서였다. 의료장비 표면 오염도 조사결과 3-way 손잡이 4.45 CFU, 컴퓨터 마우스 3.37 CFU, 거울 손잡이 1.60 CFU로 다른 영역보다 높게 조사되었다. 손 오염도가 높은 집단일수록 손의 S. epidermidis 오염도가 높은 양적 상관관계를 나타내었다. S. epidermidis 오염도는 의료장비 표면 오염보다 손에서 높게 나타났다. 그러므로 의료진들은 손 위생의 중요성을 인식하고 WHO에서 제시한 방법으로 손 위생을 실천하는 것이 요구되었다. 의료진들이 감염관리 업무수행에 책임감을 갖고 안전한 의료 환경을 조성할 수 있도록 감염관리 지침과 체계적인 감염관리 업무 수행에 관한 교육이 요구되었다.

병원 진단검사의학부의 공간구조와 설비기준에 대한 조사 - 미국, 영국, 독일을 중심으로 - (A Study on the Space Organization and Facility Equipment of Medical Laboratory - focusing on the USA, UK and Germany -)

  • 김영애
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제22권3호
    • /
    • pp.7-15
    • /
    • 2016
  • Purpose: As medicare services have gotten spreaded, clinical laboratory has been dominant position. So, it has been acted for quality control and clinical pathology accreditation. But there has been quite deficient information to evaluate working space and technical standards of medical laboratory for accreditation. This study goals to figure out accreditation standard and design guideline for clinical laboratory, and to give safe and efficient design information. Methods: This study has been searched by literature for accreditation standards and design guidelines of clinical pathology in USA, UK, and Germany. Results: Three countries have accredited based on working lab space, staff space, storage space, patient space and health and safety equipment. Design guidelines of three countries commonly have focused on worktable layout, worktable distance and module, and specific laboratory biosafety level. And USA guidelines stress on the architectural design such as design process and passage distance for escape, UK stress on the efficiency as functional work flow and construction cost, lastly Germany design guidelines stress on the operator's safety distance and workstation. Three countries have not only accreditation standards but also design guidelines for more specific quality management, separating from accrediting institute. Implications: In korea, it has been needed to make clinical laboratory design guideline for the safe and efficient environment and reliable and competitive medical service.

구급대원용 개인보호복 개발을 위한 기초연구 (Fundamental research for the development of personal protective equipment for emergency medical technicians)

  • 노유민;남윤자;이혜린;김태한;김주현;신상도
    • 한국응급구조학회지
    • /
    • 제22권1호
    • /
    • pp.83-97
    • /
    • 2018
  • Purpose: The purpose of this study was to provide basic data for the development of personal protective equipment (PPE) for emergency medical technicians (EMTs) during chemical, biological, radiological, nuclear, and explosive situations. Methods: Body measurements were obtained for adults aged from 20 to 59 years from the data in the 6 th Size Korea national sizing survey. These data were compared to the sizes of protective clothing currently available in the market. In-depth interviews with active paramedics with experiences of wearing PPE were conducted. Results: Most of the imported protective clothing turned out to be unfit for Korean adults. This showed the urgent need for developing appropriately sized protective clothing for Korean emergency technicians. In total, 55.0% of the respondents indicated that the current protective clothing is unsafe, and 71.0% requested the clothing to have level C protective performance. Regarding the design, many people wanted hooded all-in-one type of clothing. Conclusion: Considering these requirements, most of the wearers wanted their protective clothing to be fundamentally protective of their body, be available in various sizes with adjustable parts, and easy to wear and take off. They also wanted the clothing to be secure in clear sight, while not revealing any parts of their body and not interfringe with their ability to communicate with others.